Reference - Intel...Reference 16 Software • BIOS, Drivers, and Operating System Installation A....

1
Reference 16 Software • BIOS, Drivers, and Operating System Installation A. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS Setup Utility to determine the installed BIOS version. Compare this to the versions at: http://support.intel.com/support/motherboards/server/s5500bc If new versions are available, update the BIOS on your server. See the User Guide on the Intel ® Server Deployment Toolkit CD for update instructions. B. Configure your RAID Controller: Use the instructions provided with the RAID controller. C. Install your Operating System: Use the instructions provided with the RAID controller and with the operating system. D. Install Operating System Drivers: With the operating system running, insert the Intel ® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel ® Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files. 14 Install Add-in Cards See the documentation that came with your server chassis for add-in card installation. For the Intel ® Server Chassis SC5650, see the Quick Start User's Guide accompanying the chassis. Side 2 IMPORTANT NOTE: Return to your Intel ® Server Chassis Quick Start User's Guide, or your non-Intel chassis documentation to finish installation and configuration of your Intel ® Server Board S5500BC and Intel ® Server Boards S5500BCR. Return to this document to finish up, including software, BIOS, drivers and operating system installation. 7 Install DIMM Memory Modules To Install DIMMs: Memory Configurations and Population Order: This server board supports up to 8 DDR3-800/1066/1333 ECC RDIMM and ECC UDIMM. DDR3 DIMM Memory Identification: DIMM notch and socket bump must align as shown. Open both DIMM socket levers. Push down firmly on the DIMM until it snaps into place and both levers close. Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot. C A D IMPORTANT! Visually check that each latch is fully closed and correctly engaged with each DIMM edge slot. E Note location of alignment notch. B CAUTION: Avoid touching contacts when handling or installing DIMMs. E DDR3 A C D B Memory Type: Minimum of one 1 GB, DDR3 800/1066/1333 MHz compliant 240-pin DIMM. Memory sizing and configuration is supported only for qualified DIMMs approved by Intel ® . For a list of supported memory, see the tested memory list at http://support.intel.com/support/motherboards/server/s5500bc/compat.htm Note: For additional memory configurations, see the User Guide on the Intel ® Server Deployment Toolkit CD that accompanied your Intel ® Server Board S5500BC, or go to: http://support.intel.com/support/motherboards/server/s5500bc DIMM_E1 DIMM_E2 DIMM_D1 DIMM_D2 DIMM_B1 DIMM_B2 DIMM_A1 DIMM_A2 8 Make Server Board Power Connections CAUTION: Note the location of the latch on each power cable connector and align it with the matching tab on each server board socket. A Attach the CPU power connector. B C Attach the main power connector. Attach the AUX power connector if you are using the Intel ® Server Chassis SC5650. IMPORTANT NOTE: If you are using a non-Intel server chassis with an ATX power supply, see the documentation that came with your chassis for installation information. Server Board Main Power Connector Detail Latch Tab CPU Power Connector Detail A B P14 Auxiliary Signal Power Detail C 10 Connect Hard Drives/Optical Drive to Server Board Connect SATA Data Cables to server board here. Begin cable connections at the SATA 0 location. 5 4 3 2 1 0 SATA Data Cable Connector Server Board 11 Attach Intrusion Switch Cable Note: For a non-Intel chassis, see your chassis documentation for intrusion switch requirements. Intrusion Switch Connector Server Board 1 2 Attach Front Panel, Serial, and USB Connections Serial B Front Panel USB 0-1 USB 2-3 Note: For a non-Intel chassis, see your chassis documentation for front panel features and server board connection requirements. 1 3 Chassis Fan Connections For a non-Intel server chassis, see the "Making Connections ... Quick Reference" section below, and the documentation accompanying your chassis for specific chassis fan connection requirements. Attach fans with 4-pin connectors here. Server Board 15 Finishing Up Before installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power. See your chassis documentation for AC power and grounding requirements. CAUTION: See your chassis documentation for AC power and grounding requirements. Network USB 6-7 USB 8-9 NIC1 10/100/ 1000 Mb NIC2 10/100/ 1000 Mb Video Serial A Intel ® Server Board S5500BC Component Layout See your Intel ® Server Board S5500BC User's Guide for expanded component and connection information. ICH10 Note: Refer to the Technical Product Specification for Diagnostic LED decoder list. Diagnostic LEDs DIMM_A2 DIMM_A1 DIMM_B2 DIMM_B1 DIMM_E1 DIMM_E2 DIMM_D1 DIMM_D2 CPU 1 Socket CPU 2 Socket Slot 7 (PCI Express* x8) Slot 6 (PCI Express* x8, Riser Card) Slot 5 (PCI Express* x8) Slot 4 (PCI 32/33) RMM3 Slot 3 (PCI Express* x4) MGMT NIC 2 USB 9 USB 8 NIC 1 USB 7 USB 6 VGA Serial A SYS FAN 3 SYS FAN 2 SATA 4 USB 2-3 USB 0-1 SATA 5 Serial B HSBP_A Main Power CPU Power BIT1 LSB DIMM Fault LEDs Front Panel Header CPU 1 FAN SYS FAN 1 CPU 2 FAN DIMM Fault LEDs IOH P/S AUX SATA RAID Key Status LED ID LED BIT3 BIT2 BIT6 MSB BIT4 BIT5 BMC SATA 0 SATA 1 SATA 3 SATA 2 Battery IPMB SATA SGPIO Making Connections to the Server Board ... Quick Reference Notes: Not all optional connections are shown in this diagram. Refer to the Reference section of this Quick Start User's Guide, your Intel ® Server Board S5500BC and Intel ® Server Boards S5500BCR User's Guide, and your server chassis documentation for additional connection information. IMPORTANT Note: Cables should be tied for better airflow. Use cable-ties as necessary. Serial ATA F SATA SGPIO E Front USB G HSBP_A L Intrusion J IPMB K SATA RAID Key I Front USB H Aux. Power O A 12V CPU Power Main Power Serial B M Front Panel P CPU 2 Socket CPU 1 Socket CPU Fan Q R System Fan B C D 2-3 0-1 N A complete list of accessories and spares can be found at: http://support.intel.com/support/motherboards/server/s5500bc (search for the document titled “Spares and Configuration Guide”.) 9 Install Optical Drive and Hard Drive(s) See the documentation that came with your server chassis for drive installation. Note: For a non-Intel Chassis, see your chassis documentation for server board connection information. B. System Fan 1 Header C. System Fan 2 Header D. System Fan 3 Header Q. CPU1 Fan Header R. CPU2 Fan Header Intel ® Server Chassis SC5650 CPU/System Fan Connections A. +12V CPU Power Connector N. Main Power Connector O. Auxiliary Power Connector P. Front Panel Header Required Connections Intel ® Server Chassis SC5650 Optional Connections L. HSBP_A I. SATA RAID Key G. USB 0-1 H. USB 2-3 F. SATA connectors M. Serial B J. Chassis Intrusion Header K. IPMB E. SATA SGPIO Intel ® Server Chassis SC5650 Document Type Available Documents Technical Product Specification Spares and Configuration Guide Tested Hardware and Operating System List Tested Memory List Tested Processor List Software and Drivers Content In-depth technical information Supported accessories and spares list Tested peripherals and operating systems list Tested memory list Supported processors list Up-to-date firmware, driver and utility information Additional Reference documents available at: http://support.intel.com/support/motherboards/ server/s5500bc/ Accessories and Order Codes Intel ® Remote Management Module 3 SATA Slim-Line DVD AXXRMM3 AXXRAKSW5 AXXLCPPED AXXSATADVD Additional Reference documents available at: http://support.intel.com/support/motherboards/server/s5500bc/ ATX I/O Shield AXXTIO Intel ® RAID Activation Key Intel ® Local Control Panel (LCD) Common Problems and Solutions For a list of hardware components that have been tested with this system, see: http://support.intel.com/support/motherboards/server/s5500bc/ The system does not boot or show video at power-on. Check that the +12V CPU power connector is plugged in. Without this cable, the processors will not have any power. Only Intel Xeon processors 5500 series and 5600 series with 95 W and less Thermal Design Power (TDP) are supported on this server board. Previous generation Intel Xeon processors are not supported. Beep code 1-5-2-1 in a system means you do not have Intel Xeon processors 5500 series and 5600 series installed or first processor socket is empty. The system generates the memory error beep code and POST diagnostic LED message {0XE0~0XEF} that means some memory errors in early POST . Remember, all DIMMs must be: DDR3 800/1066/1333 MT/s ECC Registered DIMM and ECC unbuffered DIMM. From the same manufacturer. Installed beginning with DIMM A1. The system sometimes works, but is exhibiting erratic behavior. ® ® ® ® ® ®

Transcript of Reference - Intel...Reference 16 Software • BIOS, Drivers, and Operating System Installation A....

  • Reference

    16 Software • BIOS, Drivers, and Operating System InstallationA. Confirm BIOS Version: Look on the Server/System Management screen in the BIOS SetupUtility to determine the installed BIOS version. Compare this to the versions at:http://support.intel.com/support/motherboards/server/s5500bcIf new versions are available, update the BIOS on your server. See the User Guide on the Intel® ServerDeployment Toolkit CD for update instructions.

    B. Configure your RAID Controller: Use the instructions provided with the RAID controller.

    C. Install your Operating System: Use the instructions provided with the RAID controllerand with the operating system.

    D. Install Operating System Drivers: With the operating system running, insert theIntel® Server Deployment Toolkit CD. If using a Microsoft Windows* operating system, the Intel®Deployment Assistant will autorun and allow you to select the appropriate drivers to install. On other operating systems, browse the CD folders to locate and install the driver files.

    14 Install Add-inCards

    See the documentation that came with your server chassis for add-in card installation.

    For the Intel® Server Chassis SC5650, see the Quick Start User's Guide accompanying the chassis.

    Side

    2

    IMPORTANT NOTE: Return to your Intel® ServerChassis Quick Start User's Guide, or your non-Intelchassis documentation to finish installation andconfiguration of your Intel® Server Board S5500BC andIntel® Server Boards S5500BCR.

    Return to this document to finish up, including software,BIOS, drivers and operating system installation.

    7 Install DIMM Memory Modules To Install DIMMs:Memory Configurations and Population Order:This server board supports up to 8 DDR3-800/1066/1333ECC RDIMM and ECC UDIMM.

    DDR3 DIMM Memory Identification:

    DIMM notch andsocket bump mustalign as shown.

    Open both DIMM socket levers.

    Push down firmly on the DIMM until itsnaps into place and both levers close.

    Insert DIMM making sure the connector edge of the DIMM aligns correctly with the slot.

    C

    A

    D

    IMPORTANT! Visually check that eachlatch is fully closed and correctlyengaged with each DIMM edge slot.

    E

    Note location of alignment notch.B

    CAUTION: Avoid touching contacts when handling or installing DIMMs.

    E

    DDR3 A

    C

    D B

    Memory Type: Minimum of one 1 GB, DDR3 800/1066/1333 MHz compliant 240-pin DIMM.

    Memory sizing and configuration is supported only for qualified DIMMs approved byIntel®. For a list of supported memory, see the tested memory list athttp://support.intel.com/support/motherboards/server/s5500bc/compat.htm

    Note: For additional memory configurations, see the User Guide on the Intel® ServerDeployment Toolkit CD that accompanied your Intel® Server Board S5500BC, or go to:http://support.intel.com/support/motherboards/server/s5500bc

    DIMM_E1DIMM_E2DIMM_D1DIMM_D2

    DIMM_B1DIMM_B2DIMM_A1DIMM_A2

    8 Make ServerBoard PowerConnections

    CAUTION:Note the location of the latch on each powercable connector and align it with thematching tab on each server board socket.

    A Attach the CPU power connector.

    B

    C

    Attach the main power connector.

    Attach the AUX power connectorif you are using the Intel® Server Chassis SC5650.

    IMPORTANT NOTE: If you are using a non-Intel server chassis with an ATX power supply, see the documentation that came with your chassis for installation information.

    Server Board

    Main PowerConnector Detail

    Latch

    TabCPU Power

    Connector Detail

    A

    B

    P14

    Auxiliary SignalPower Detail

    C

    10 Connect Hard Drives/OpticalDrive to Server Board

    Connect SATA Data Cablesto server board here.Begin cable connectionsat the SATA 0 location.

    543

    2 1 0

    SATA DataCable Connector

    ServerBoard

    11 Attach Intrusion Switch Cable

    Note: For a non-Intel chassis, see your chassis documentation for intrusion switch requirements.

    IntrusionSwitch

    Connector

    Server Board

    12 Attach Front Panel, Serial, and USB Connections

    Serial B

    FrontPanel

    USB 0-1 USB 2-3

    Note: For a non-Intel chassis, see your chassis documentation forfront panel features and server board connection requirements.

    13 Chassis Fan Connections

    For a non-Intel server chassis, see the "Making Connections ... Quick Reference"section below, and the documentation accompanying your chassis for specificchassis fan connection requirements.

    Attach fans with 4-pin connectorshere.

    Server Board

    15 Finishing UpBefore installing your operating system, you must finish your chassis installation, make I/O connections and plug in AC power.

    See your chassisdocumentation for ACpower and groundingrequirements.

    CAUTION: See your chassisdocumentation for AC power and grounding requirements.

    Network

    USB6-7

    USB8-9

    NIC110/100/

    1000 Mb

    NIC210/100/

    1000 Mb

    VideoSerial A

    Intel® Server Board S5500BCComponent Layout

    See your Intel® ServerBoard S5500BC User's Guide for expanded component and connection information.

    ICH10

    Note: Refer to theTechnical ProductSpecification forDiagnostic LED

    decoder list.

    Diagnostic LEDs

    DIM

    M_A

    2

    DIM

    M_A

    1

    DIM

    M_B

    2

    DIM

    M_B

    1

    DIM

    M_E

    1

    DIM

    M_E

    2

    DIM

    M_D

    1

    DIM

    M_D

    2 CPU 1 Socket

    CPU 2 Socket

    Slot

    7 (P

    CI E

    xpre

    ss* x

    8)

    Slot

    6 (P

    CI E

    xpre

    ss* x

    8, R

    iser

    Car

    d)

    Slot

    5 (P

    CI E

    xpre

    ss* x

    8)

    Slot

    4 (P

    CI 3

    2/33

    ) RM

    M3

    Slot

    3 (P

    CI E

    xpre

    ss* x

    4)

    MGMTNIC 2USB 9USB 8

    NIC 1USB 7USB 6

    VGA

    Serial A

    SYS FAN 3

    SYS FAN 2

    SATA 4

    USB 2-3

    USB 0-1

    SATA 5

    Serial B

    HSBP_A

    Main Power

    CPU Power

    BIT1LSB

    DIMM FaultLEDs

    Fron

    t Pan

    el H

    eade

    r

    CPU 1 FAN

    SYS FAN 1 CPU 2 FAN

    DIMM Fault LEDs

    IOH

    P/S AUX

    SATA RAIDKey

    Status LEDID LED

    BIT3BIT2

    BIT6MSB

    BIT4BIT5

    BMC

    SATA 0

    SATA 1

    SATA 3

    SATA 2 Battery IPMB

    SATA SGPIO

    Making Connections to the Server Board ... Quick Reference

    Notes: Not all optional connections are shown in this diagram. Refer to the Reference section of this Quick Start User's Guide, your Intel® Server Board S5500BC and Intel® Server BoardsS5500BCR User's Guide, and your serverchassis documentation for additional connection information.

    IMPORTANT Note:Cables should be tiedfor better airflow.Use cable-ties as necessary.

    Serial ATA

    F

    SATA SGPIO

    E

    Front USBG

    HSBP_AL

    IntrusionJ

    IPMBK

    SATA RAID KeyI

    Front USBH

    Aux. Power

    O

    A12V CPU Power

    Main Power

    Serial BM

    Front Panel

    P

    CPU 2 Socket

    CPU 1 Socket

    CPU FanQ R

    System Fan

    B CD

    2-30-1

    N

    A complete list of accessories and spares can be found at:http://support.intel.com/support/motherboards/server/s5500bc(search for the document titled “Spares and Configuration Guide”.)

    9 Install Optical Drive and Hard Drive(s)

    See the documentation that came with your server chassis for drive installation.

    Note: For a non-Intel Chassis, see your chassis documentation for server board connection information.

    B. System Fan 1 HeaderC. System Fan 2 HeaderD. System Fan 3 HeaderQ. CPU1 Fan HeaderR. CPU2 Fan Header

    Intel® Server Chassis SC5650CPU/System Fan Connections

    A. +12V CPU Power ConnectorN. Main Power ConnectorO. Auxiliary Power ConnectorP. Front Panel Header

    Required Connections Intel® Server Chassis SC5650

    Optional ConnectionsL. HSBP_AI. SATA RAID KeyG. USB 0-1H. USB 2-3F. SATA connectorsM. Serial BJ. Chassis Intrusion HeaderK. IPMBE. SATA SGPIO

    Intel® Server Chassis SC5650

    Document TypeAvailable Documents

    Technical Product SpecificationSpares and Configuration GuideTested Hardware and Operating System ListTested Memory ListTested Processor ListSoftware and Drivers

    ContentIn-depth technical informationSupported accessories and spares listTested peripherals and operating systems listTested memory listSupported processors listUp-to-date firmware, driver and utility information

    Additional Reference documents available at: http://support.intel.com/support/motherboards/server/s5500bc/

    Accessories and Order Codes

    Intel® Remote Management Module 3

    SATA Slim-Line DVD

    AXXRMM3AXXRAKSW5AXXLCPPEDAXXSATADVD

    Additional Reference documents available at: http://support.intel.com/support/motherboards/server/s5500bc/

    ATX I/O Shield AXXTIO

    Intel® RAID Activation KeyIntel® Local Control Panel (LCD)

    Common Problems and SolutionsFor a list of hardware components that have been tested with this system,see: http://support.intel.com/support/motherboards/server/s5500bc/

    The system does not boot or show video at power-on.

    • Check that the +12V CPU power connector is plugged in. Without this cable, the processors will not have any power.

    • Only Intel Xeon processors 5500 series and 5600 series with 95 W and less Thermal Design Power (TDP) are supported on this server board. Previous generation Intel Xeon processors are not supported. Beep code 1-5-2-1 in a system means you do not have Intel Xeon processors 5500 series and 5600 series installed or first processor socket is empty.

    • The system generates the memory error beep code and POST diagnostic LED message {0XE0~0XEF} that means some memory errors in early POST .

    • Remember, all DIMMs must be: • DDR3 800/1066/1333 MT/s ECC Registered DIMM and ECC unbuffered DIMM. • From the same manufacturer. • Installed beginning with DIMM A1.

    The system sometimes works, but is exhibiting erratic behavior.

    ® ®

    ® ®

    ® ®