419 Characteristics: Plate heat exchanger made of aluminium panels with an efficiency of between 52%-55%. Possibility of configuration with different nozzle positions. Built-in filters, classes G4, F6 and F6+F8. Other combinations available on request. Box made of galvanised steel with built-in acoustic insulation. Construction: Galvanised sheet steel structure. Entry and exit nozzles with water-tight gaskets. • Interchangeable nozzles. Access door for ease of maintenance and cleaning. Versions: Horizontal (H) or vertical (V). Environmental: Air renewal without heat supply (S). On request: Electric: Heat supplied by electric coils (EB). Water coil: Heat supplied by water coils (WB). Adiabatic module. Configurable heat recovery units with cross-flow panels, for horizontal (H) or vertical (V) installation RECUP F6 F8 F6 Order code RECUP 20 H C F6 H: Horizontal configuration V: Vertical configuration Size Model A-F: Nozzle position (Standard C or B based on model) F6 filter F6+F8 filter G4 filter Technical characteristics Voltage (V) Current (A) Motor power (W) Maximum flow rate F6(m 3 /h) Speed (r/min) Thermal efficiency (%) Irradiated SPL dB(A) Filter EN 779 Weight (kg) Model RECUP-12-H 1710 1x220 2x2.00 2x450 1300 52 53 G4, F6, F6+F8 67 RECUP-20-H 1620 1x220 2x2.00 2x450 2050 52 48 G4, F6, F6+F8 86 RECUP-20-V 1620 1x220 2x2.00 2x450 2050 52 48 G4, F6, F6+F8 86 RECUP-30-H 1500 1x220 2x5.40 2x600 3150 54 52 G4, F6, F6+F8 112 RECUP-30-V 1500 1x220 2x5.40 2x600 3150 54 52 G4, F6, F6+F8 112 RECUP-40-H 1080 3x380 2x3.60 2x1100 4250 55 46 G4, F6, F6+F8 167 RECUP-40-V 1080 3x380 2x3.60 2x1100 4250 55 46 G4, F6, F6+F8 167 RECUP-50-H 1536 3x380 2x3.50 2x1500 5350 53 54 G4, F6, F6+F8 182 RECUP-50-V 1536 3x380 2x3.50 2x1500 5350 53 54 G4, F6, F6+F8 182 RECUP-60-H 1740 3x380 2x4.83 2x2200 6150 50 56 G4, F6, F6+F8 205 RECUP-60-V 1740 3x380 2x4.83 2x2200 6150 50 56 G4, F6, F6+F8 205 RECUP-H RECUP-V 60Hz RECUP

Transcript of RECUP F8 - SODECA, S.L.U.

Page 1: RECUP F8 - SODECA, S.L.U.

419

Characteristics:• Plate heat exchanger made of aluminium

panels with an efficiency of between 52%-55%.

• Possibility of configuration with different nozzle positions.

• Built-in filters, classes G4, F6 and F6+F8. Other combinations available on request.

• Box made of galvanised steel with built-in acoustic insulation.

Construction:• Galvanised sheet steel structure.• Entry and exit nozzles with water-tight

gaskets.• Interchangeable nozzles.

• Access door for ease of maintenance and cleaning.

Versions:• Horizontal (H) or vertical (V).• Environmental: Air renewal

without heat supply (S).

On request: • Electric: Heat supplied by

electric coils (EB). • Water coil: Heat supplied

by water coils (WB). • Adiabatic module.

Configurable heat recovery units with cross-flow panels, for horizontal (H) or vertical (V) installation

RECUP F6 F8F6

Order code

RECUP 20 H C F6

H: Horizontal configurationV: Vertical configuration

SizeModel A-F: Nozzle position(Standard C or B based on model)

F6 filterF6+F8 filterG4 filter

Technical characteristics

Voltage (V)

Current(A)

Motor power(W)

Maximum flow rateF6(m3/h)

Speed(r/min)

Thermal efficiency

(%)

Irradiated SPL

dB(A)

FilterEN 779

Weight (kg)

Model

RECUP-12-H 1710 1x220 2x2.00 2x450 1300 52 53 G4, F6, F6+F8 67RECUP-20-H 1620 1x220 2x2.00 2x450 2050 52 48 G4, F6, F6+F8 86RECUP-20-V 1620 1x220 2x2.00 2x450 2050 52 48 G4, F6, F6+F8 86RECUP-30-H 1500 1x220 2x5.40 2x600 3150 54 52 G4, F6, F6+F8 112RECUP-30-V 1500 1x220 2x5.40 2x600 3150 54 52 G4, F6, F6+F8 112RECUP-40-H 1080 3x380 2x3.60 2x1100 4250 55 46 G4, F6, F6+F8 167RECUP-40-V 1080 3x380 2x3.60 2x1100 4250 55 46 G4, F6, F6+F8 167RECUP-50-H 1536 3x380 2x3.50 2x1500 5350 53 54 G4, F6, F6+F8 182RECUP-50-V 1536 3x380 2x3.50 2x1500 5350 53 54 G4, F6, F6+F8 182RECUP-60-H 1740 3x380 2x4.83 2x2200 6150 50 56 G4, F6, F6+F8 205RECUP-60-V 1740 3x380 2x4.83 2x2200 6150 50 56 G4, F6, F6+F8 205

RECUP-H

RECUP-V

60Hz

RECUP

Page 2: RECUP F8 - SODECA, S.L.U.

420

Configurations (horizontal version)Standard supply C configuration. Except model 12, B configuration.Configuration A

FilterFilter

IL

SV

AF

EL

FilterFilter IL

SVAF

EL

FilterFilter

IL

SVAF

EL

FilterFilter

SV

ILEL

AFFilter

Filter

SV

IL

AF

EL

FilterFilter

SV

EL

AF

IL

B configuration C configuration D configuration E configuration F configuration

AF: External fresh air / IL: Impulsion of air to premises / SV: Exit of stale air / EL: Air extraction from premises

RECUP

Dimensions mm

RECUP-12-H 415 1000 1000 315 260.4 479.2 260.4 207.5 207.5RECUP-20-H 490 1050 1050 315 251 548 251 280 280RECUP-30-H 590 1100 1200 315 266 668 266 350 350RECUP-40-H 670 1500 1500 450 350 800 350 368 368RECUP-50/60-H 850 1500 1700 450 351.5 997 351.5 424.5 424.5

Model A B L øD H1 H2 H3 W W1

RECUP-12-H 415 1000 1525 1000 315 260.4 479.2 260.4 207.5 207.5 207.5 207.5RECUP-20-H 490 1050 1575 1050 315 251 548 251 250 280 280 280RECUP-30-H 590 1100 1625 1200 315 266 668 266 320 350 350 350RECUP-40-H 670 1500 2025 1500 450 350 800 350 368 368 368 368RECUP-50/60-H 849 1500 2025 1700 450 351.5 997 351.5 424.5 424.5 424.5 424.5

Model A B B1 L øD H1 H2 H3 W W1 W2 W3

RECUP H F6

RECUP H F6+F8

Page 3: RECUP F8 - SODECA, S.L.U.

421

Dimensions mm

RECUPRECUP

RECUP-20-V 500 620 1050 30 1050 315 298 501 251 250 250RECUP-30-V 600 720 1202 30 1102 315 384 548 270 300 300RECUP-40-V 670 790 1500 30 1500 450 391.5 739 369.5 334 335RECUP-50-V 805 925 1700 30 1500 450 441 912 347 402.5 402.5RECUP-60-V 805 925 1700 30 1500 450 441 912 347 402.5 402.5

Model A A1 B B1 L øD H1 H2 H3 W W1

RECUP-20-V 500 620 1050 30 1050 1487 315 252 501 251 298 250 250RECUP-30-V 600 720 1202 30 1102 1540 315 335 548 270 384 300 300RECUP-40-V 670 790 1500 30 1500 1933 450 369.5 739 369.5 391.5 334 335RECUP-50-V 805 925 1700 30 1500 1933 450 403.5 912 347 441 402.5 402.5RECUP-60-V 805 925 1700 30 1500 1933 450 403.5 912 347 441 402.5 402.5

Model A A1 B B1 L L1 øD H1 H2 H3 H4 W W1

RECUP V F6

RECUP V F6+F8

Page 4: RECUP F8 - SODECA, S.L.U.

422

Characteristic curves

The indicated values are determined by measuring the sound power level in dB(A) obtained in a free field at a distance of no less than 1.5 m from the equipment.

Acoustic characteristics

Sound power spectrum Lw(A) in dB(A) per Hz frequency band

Model 63 125 250 500 1000 2000 4000 8000RECUP-12 54 56 49 52 54 50 45 38RECUP-20 49 51 44 47 49 45 40 33RECUP-30 54 56 50 51 48 43 35 31

RECUP-40 49 51 43 37 36 30 29 15RECUP-50 57 59 50 44 42 36 37 22RECUP-60 59 61 52 46 44 38 39 24

Model 63 125 250 500 1000 2000 4000 8000

RECUP

Accessories

CJFILTER SI-PRESIÓN INT TEJPRESSURE SWITCH

GENERAL BENCH

SILENT-BLOCKS

FILTERS ADIABATIC BOX WATER COILFOR RECOV

ELECTRIC COILFOR RECOV