Recommended Field End Make-Up Torque - Metal …€¦ · GEOCONN A METAL ONE CONNECTION 757 N....

2
GEOCONN A METAL ONE CONNECTION 757 N. Eldridge Parkway, Suite #650 Houston, Texas 77079 www.mtlo.co.jp/us/ Torque Table for Selected Sizes * Recommended Field End Make-Up Torque *Other sizes available upon request. Visit http://www.mtlo.co.jp/mo-con/index.html for more information. Designation Pipe body Unit: Ft-Lbs Size OD (inch) Nom. Weight (lbs/ft) Wall Thickness (inch) L/N80 P110 Min Opt Max Yield Min Opt Max Yield 4 1/2 13.5 0.290 6,700 7,450 8,200 9,000 8,100 9,000 9,900 12,100 15.1 0.337 7,200 8,000 8,800 10,400 9,000 10,000 11,000 15,300 5 1/2 17.0 0.304 9,000 10,000 11,000 12,500 10,800 12,000 13,200 18,400 20.0 0.361 12,500 13,850 15,200 15,600 14,600 16,200 17,800 23,000 23.0 0.415 15,300 17,000 18,700 19,100 18,350 20,400 22,450 28,000 7 23.0 0.317 12,500 13,850 15,200 20,900 15,100 16,800 18,500 30,700 26.0 0.362 16,500 18,300 20,100 25,000 20,000 22,200 24,400 36,800 29.0 0.408 18,000 20,000 22,000 29,200 22,700 25,200 27,700 42,900 32.0 0.453 20,250 22,500 24,750 33,100 24,300 27,000 29,700 48,700 GEOCONN Applications Geothermal Wells: Prevention of turbulence flow SAGD: Liner for SAGD Wells Drilling with Casing: For high torque resistance Shale Plays: Full string for shale or tight plays API BTC Problem 1. The gap at the center of the coupling can cause turbulence flow. 2. Possible scale buildup at center gap or J area. 3. The Buttress threads have poor leak resistance against gas/steam. GEOCONN Solution 1. GEOCONN prevents turbulence flow. 2. The abutment works as a metal seal during production at a high temperature. API Buttress GEOCONN API Buttress vs. GEOCONN Coupling center has gap Pin abutment Without limiting and in addition to other disclaimers contained in the site, while every effort has been made to ensure the accuracy of the information, Metal One Corporation and its parents, subsidiaries or affiliates, including but not limited to MC Tubular Products. Inc, (herein collectively referred to as “Metal One”) does not assume any responsibility or liability for any loss, damage or injury resulting from the use of information and data provided herein. It is the responsibility of the customer to make all engineering and safety-related determinations for their own account. Customers should therefore undertake all necessary investigations when developing the technical solution and safety factors for the specific installation and operating conditions for the products. Metal One’s products are not recommended for use in deep water offshore applications. For more information, please contact your Metal One sales representative or refer to http://www.mtlo.co.jp/mo-con/_images/top/WebsiteTerms_Active_20333287_1.pdf, the contents of which will apply to any purchases of these products.

Transcript of Recommended Field End Make-Up Torque - Metal …€¦ · GEOCONN A METAL ONE CONNECTION 757 N....

Page 1: Recommended Field End Make-Up Torque - Metal …€¦ · GEOCONN A METAL ONE CONNECTION 757 N. Eldridge Parkway, Suite #650 Houston, Texas 77079 Torque Table for Selected Sizes* Recommended

GEOCONNA METAL ONE CONNECTION

757 N. Eldridge Parkway, Suite #650

Houston, Texas 77079

www.mtlo.co.jp/us/

Torque Table for Selected Sizes* Recommended Field End Make-Up Torque

*Other sizes available upon request. Visit http://www.mtlo.co.jp/mo-con/index.html for more information.

Designation Pipe body Unit: Ft-Lbs

Size OD(inch)

Nom. Weight(lbs/ft)

Wall Thickness(inch)

L/N80 P110

Min Opt Max Yield Min Opt Max Yield

4 1/213.5 0.290 6,700 7,450 8,200 9,000 8,100 9,000 9,900 12,100

15.1 0.337 7,200 8,000 8,800 10,400 9,000 10,000 11,000 15,300

5 1/2

17.0 0.304 9,000 10,000 11,000 12,500 10,800 12,000 13,200 18,400

20.0 0.361 12,500 13,850 15,200 15,600 14,600 16,200 17,800 23,000

23.0 0.415 15,300 17,000 18,700 19,100 18,350 20,400 22,450 28,000

7

23.0 0.317 12,500 13,850 15,200 20,900 15,100 16,800 18,500 30,700

26.0 0.362 16,500 18,300 20,100 25,000 20,000 22,200 24,400 36,800

29.0 0.408 18,000 20,000 22,000 29,200 22,700 25,200 27,700 42,900

32.0 0.453 20,250 22,500 24,750 33,100 24,300 27,000 29,700 48,700

GEOCONN ApplicationsGeothermal Wells: Prevention of turbulence flow SAGD: Liner for SAGD Wells

Drilling with Casing: For high torque resistance Shale Plays: Full string for shale or tight plays

API BTC

Problem

1. The gap at the center of the coupling can cause turbulence flow.

2. Possible scale buildup at center gap or J area.

3. The Buttress threads have poor leak resistance against gas/steam.

GEOCONN

Solution

1. GEOCONN prevents turbulence flow.

2. The abutment works as a metal seal during production at a high temperature.

API Buttress GEOCONN

API Buttress vs. GEOCONN

Coupling center has gap Pin abutment

Without limiting and in addition to other disclaimers contained in the site, while every effort

has been made to ensure the accuracy of the information, Metal One Corporation and its

parents, subsidiaries or affiliates, including but not limited to MC Tubular Products. Inc, (herein

collectively referred to as “Metal One”) does not assume any responsibility or liability for any

loss, damage or injury resulting from the use of information and data provided herein. It is the

responsibility of the customer to make all engineering and safety-related determinations for

their own account. Customers should therefore undertake all necessary investigations when

developing the technical solution and safety factors for the specific installation and operating

conditions for the products. Metal One’s products are not recommended for use in deep water

offshore applications. For more information, please contact your Metal One sales representative

or refer to http://www.mtlo.co.jp/mo-con/_images/top/WebsiteTerms_Active_20333287_1.pdf,

the contents of which will apply to any purchases of these products.

Page 2: Recommended Field End Make-Up Torque - Metal …€¦ · GEOCONN A METAL ONE CONNECTION 757 N. Eldridge Parkway, Suite #650 Houston, Texas 77079 Torque Table for Selected Sizes* Recommended

HIGH TORQUEThe GEOCONN connection features a high over-torque resistance and a high fatigue resistance. Additionally, the connection offers prevention of turbulence flow as the abutment works as a metal seal under medium tension loads.

BUTTRESS COMPATIBLEGEOCONN is completely interchangeable with API Buttress. All accessories with API Buttress threads can be used in conjunction with GEOCONN.

COMPETITIVE PRICINGThe shorter coupling length of GEOCONN means less material per coupling which equals a lower price per connection.

GEOCONN is compatible with API Buttress accessories, reducing the need to purchase any additional accessories. The same threading tools used for API Buttress are used to manufacture GEOCONN.

Manufacturing of GEOCONNThe manufacturing of GEOCONN is very similar to Buttress with one of the main differences being the shorter coupling length.

GEOCONN Mill Make-up Position The mill end is made up slightly deeper than the center of the coupling to prevent mill end rotation during field make-up. The make-up distances were chosen to provide good leak resistance and prevent any increases in hoop stress.

GEOCONN 4 1/2" – 20"

Mill tight end Field tight end

GEOCONN Technical DataTest Results of Over-Torque to Yielding

0.0000 0.5500 1.1000 1.6500 2.2000 2.7500 3.3000 3.8500 4.4000 4.9500 5.5000000100

027500

030000

032500

0.5000

0

3575

7150

10725

14300

17875

21450

25025

28600

32175

35750

Turns

Torq

ue (f

t/lb

s)

Yield Torque Failure Torque

2.510125015.87

Size GradeGECONN

Yield TorqueAPI BTC

Max. Torque

5 1/2" x 20#L80 15,600 3,400

P110 23,000 4,700

7" x 26#L80 25,000 6,300

P110 36,800 8,500

9 5/8'' x 47#L80 63,100 14,400

P110 89,000 17,600

13 3/8'' x 72#L80 128,800 18,900

P110 183,600 26,000

Connection P

erformance P

roperties

Pipe B

odyP

inC

ouplingC

ollapseInternal Y

ield Pressure

Minim

um Y

ield Load

Outside

Diam

eter(inch)

Nom

inal W

eight(lbs/ft)

Wall

Thickness(inch)

Inside D

iameter

(inch)

Drift

Diam

eter(inch)

Makeup Loss(inch)

Standard C

oupling O

D(inch)

Special C

learance O

D(inch)

Length(inch)

J55 K55(psi)

L80 N

80(psi)

P110(psi)

J55 K55(psi)

L80 N

80(psi)

P110(psi)

J55(kips)

K55(kips)

N80

(kips)L80(kips)

P110(kips)

4 1/2

10.50.224

4.0523.927

3.9845.000

4.8758.068

4,0104,930

5,5504,790

6,9709,580

166241

331

11.60.250

4.0003.875

4,9606,360

7,5805,350

7,78010,690

184267

367

13.50.290

3.9203.795

6,4208,540

10,6906,200

9,02012,410

211307

422

15.10.337

3.8263.701

7,62011,080

14,3407,210

10,48014,420

242353

485

5 1/2

15.50.275

4.9504.825

4.1256.050

5.8758.350

4,0404,990

5,6304,810

7,0009,630

248361

496

17.00.304

4.8924.767

4,9106,290

7,4805,320

7,74010,640

273397

546

20.00.361

4.7784.653

6,6208,830

11,1106,320

9,19012,640

320466

641

23.00.415

4.6704.545

7,67011,160

14,5407,260

10,56014,530

364530

729

7

23.00.317

6.3666.241

4.5007.875

7.3759.100

3,2703,830

4,4404,360

6,3408,720

366532

732

26.00.362

6.2766.151

4,3305,410

6,2304,980

7,2409,960

415604

830

29.00.408

6.1846.059

5,4107,030

8,5305,610

8,16011,220

464676

929

32.00.453

6.0945.969

6,4608,610

10,7806,230

9,06012,460

512745

1,025

9 5/8

36.00.352

8.9218.765

4.81310.625

10.1259.826

2,0202,370

2,4703,520

5,1207,040

564820

1,127

40.00.395

8.8358.679

2,5703,090

3,4703,950

5,7507,900

630916

1,259

43.50.435

8.7558.599

3,2503,810

4,4204,350

6,3308,700

6901,005

1,381

47.00.472

8.6818.525

3,8904,760

5,3004,720

6,8709,440

7461,086

1,493

53.50.545

8.5358.500

5,1306,620

7,9505,450

7,93010,900

8551,244

1,710

13 3/8

54.50.380

12.61512.459

4.81314.375

—9.826

1,1301,140

1,1402,730

3,9805,470

8531,240

1,706

61.00.430

12.51512.359

1,5401,670

1,6703,090

4,5006,190

9611,398

1,923

68.00.480

12.41512.259

1,9502,260

2,3303,450

5,0206,910

1,0691,556*

1,545*2,138

72.00.514

12.34712.191

2,2202,670

2,8803,700

5,3807,400

1,1421,661*

1,650*2,283

*Joint strength, not yield load.

Finite Element Analysis DataShoulder-type seals work as well as metal-to-metal seals as long as the shoulder is closed. Note that high tension could open the gap on the shoulder-type seal.

-120

-100

-80

-60

-40

-20

0

20

Con

tact

Pre

ssur

e (k

si)

OD Shoulder Face ID

T60 T80

T70

T50

MU

Additional sizes available.

Tension to Failure After 100% Compression

Test Results

Actual Failure Load 1,451 kips

Pipe Body Yield Load 1,086 kips

Joint Strength 1,122 kips

9 5/8" X 40# L80 GEOCONN

Connection D

ata (Im

perial Unit)

This figure implies that even T80 (80% pipe body yield tension) does not open the shoulder.

4 1/2" x 13.5# L80 GEOCONN