ReaMetrix Product Catalog 2010
Transcript of ReaMetrix Product Catalog 2010
-
8/14/2019 ReaMetrix Product Catalog 2010
1/10
1585 Industrial RoadSan Carlos, CA 94070USAPhone : +1 650 620 9253
Fax : +1 650 620 0093
50-B, II PhasePeenya Industrial AreaPeenya, Bangalore 560058, IndiaPh: +91-80-28378693/5Fax: +91-80-41172451
E-mail: [email protected]: www.reametrix.com
ReaMetrix help us in keeping our commitmentin oering tests at aordable costs especially HIV.We have so far conducted hundreds of tests andhave obtained accurate and reproducible results.The availability of these reagents at this very af-
fordable price point has allowed us to signicantlyreduce the cost of these tests to the patient.
Dr. Sujay Prasad, Director, Anand Diagnostics
With the new concept of dried reagents a samplecan be added to the reagent tube where the sampleis collected. The sample integrity is maintainedupto a week at temperatures upto 40C. This givesus tremendous exibility in the way samples canbe handled.
Dr.Anjali Kale, Head Reference Laboratory,Dr Lal Pathlabs
ISO 9001:2008certifed company
www.reametrix.com
ReaMetrixAccelerating Innovation
-
8/14/2019 ReaMetrix Product Catalog 2010
2/10
Company
ReaMetrix, Inc. is a nextgeneration biotechnologycompany that was founded withthe unique business model ofusing the labor cost arbitragethrough India to create signi-cant and sustainable
value arbitrage. As with theearly Silicon Valley entrepre-neurs, we are working to build acompany culture that providestalented Indian scientists withan environment where they havefreedom to exercise their train-ing, skills and imagination whilebuilding corporate value. Ouregalitarian approach allows us toencourage and reward initiativethroughout our organization.Our people are the key to oursuccess.
The challenge of technological inno-vation is to create solutions that arelocally aordable and sustainable inthe long run within the local macro-economic constraints. The solutions
should permit generation of localeconomic activity that will reinforcelong-term economic sustainability.
Bala S. Manian, CEO ReaMetrixInc..Aordable DiagnosticsChang -ing the Paradigm in India. Cytometry
Part B (Clinical Cytometry) 74B(Suppl. 1):S117S122 (2008)
Process is our Product
At ReaMetrix, we have built aworld-class research and devel-opment facility in Bangalore,India with a primary focus ofapplying Six Sigma product de-velopment strategies to diagnos-tic and life science products. We
believe that process control is acritical component of generatinghigh quality data and products.Our corporate infrastructureis process-centric, and we liveby our philosophy on a dailybasis. Rigorous documentation,full audit trails, and a dedicatedquality group result in high qual-ity products, and reproducible,trustworthy data. At ReaMetrix,Process is our Product.
ReaMetrix is committed tobecoming the leading provider ofhigh quality research and diag-nostic assay solutions resultingin a transformation of the costopportunities available in Indiainto value for both the biotech-
nology and global health sectors.
-
8/14/2019 ReaMetrix Product Catalog 2010
3/10
HIV Immunophenotyping
Reagents forDiagnostic Use
CatalogNumber
Product/Reagent
IntendedUse
Format Storage KitSizes
25118-00 Dry Tri T-STAT
CD3/CD4/CD8 Reagent *
Dry Room
Temperature
50For determining absolute counts of human
total T, helper/inducer & suppressor/cytotoxicT lymphocytes in erythrocyte-lysedwhole blood
25197-00 Dry Tri T-STATCD3/CD4/CD45 Reagent
Dry RoomTemperature
50For determining absolute lymphocyte count(ALC), percentages & absolute counts of hu-man total T and helper/inducer T lymphocytesin erythrocyte-lysed whole blood
25239-00 ReaPan 34845Reagent
Dry RoomTemperature
50For determining ALC, percentages and absolutecounts of human total T, helper/inducer &
Suppressor/cytotoxic T lymphocytes in eryth-rocyte-lysed whole blood
25244-00 ReaPan 3 4 GReagent
Dry RoomTemperature
50Reagent For determining absolute counts ofhuman total T, helper/inducer T lymphocyteson Guava Platform
25332-00 ReaPan 3 8 GReagent
Dry RoomTemperature
50For determining absolute counts of humantotal T, suppressor/cytotoxic T lymphocyteson Guava Platform
25124-00 Rea T-Count CD4/CD3 & CD8/CD3(Dual tube) Reagent
Dry RoomTemperature
50For determining absolute counts of human to-tal T, helper/inducer & suppressor/cytotoxic Tlymphocytes in erythrocyte-xed whole bloodon BD FACSCount platform
25242-00 Rea T Count CD4/CD3 (Single Tube)Reagent
Dry RoomTemperature
50For determining absolute counts of humantotal T, helper/inducer T lymphocytes inerythrocyte-xed whole blood onBD FACSCount platform
Decentralized Staining Concept
Blood samples from collectioncentres that operate in resourcepoor settings, age by the time asthey are shipped to c entralizedtesting facilities. CD receptors areknown to undergo a process calledcapping (internalization of
receptors), with sample ageing.
Dry reagents enable staining tobe done in collection centres thattypically have no electricity torun refrigeration units. Stainedsamples can then be transportedwithout the need for cold chain.
The decentralized approach tosample processing mitigates therisk associated with variation incell counts. Studies on samplesstained and xed using dry re-
agents have shown that there is nodrop in staining intensity or cellcount upto 8 days when stored atroom temperature.
Regulatory Status
ReaMetrix Reagents conform tohighest international standardsof quality. Most of the diagnosticreagents are CE marked and/orFDA cleared. For details, please
contact us.
* For In Vitro Diagnostic Usein the United States
-
8/14/2019 ReaMetrix Product Catalog 2010
4/10
Reagents forDiagnostic Use
25238-00 ReaPan
B27
Dry RoomTemperature
25For detection of HLA-B27 antigen expressionin erythrocyte-lysed whole blood (LWB) using
ow cytometry
25323-00 ReaPanS34
Dry RoomTemperature
25For enumeration of Hematopoietic stem cellsCD34+ in human peripheral or mobilized bloodsamples, umbilical cord blood samples, bonemarrow samples and leukapheresis samples byow cytometry
25329-00 ReaPan
Micro
Dry Room
Temperature
50For screening of Urine samples for presence/
absence of bacteria by ow cytometry
25108-00 ReaCountTubes
Dry RoomTemperature
50Absolute Counting Fluorescent Beads-Providesabsolute counts for immunophenotyping
CatalogNumber
Product/Reagent
IntendedUse
Format Storage KitSizes
Hematopoietic CD34+ Stem Cell Enumeration
Presence/Absence test for Bacteria in Urine
ReaCount Tubes
HLA B-27 Typing
ReaPan S34: Ease in Workfow
ReaMetrix Stem cell enumera-tion reagents are provided in oneready-to-use reagent dried tube.The assay just needs additionof sample, simplifying samplepreparation. Incubation time is 30minutes, speeding time to results;
a boon to diagnostic labs thatprocess multiple samples simulta-neously. Predispensed uorescencereference beads included in thereagent tube, ensure accurateenumeration of CD34+ cellsinterest. The result: more ecientworkow and greater condencein results.
ReaMetrix HLA B27 reagent:Enabling Reduced HLA-B7 CrossReactivity
The only existing owcytometry based reagent featuringtwo antibodies against the HLA-B27 antigen. The result: increasedSensitivity. The reagent use anti-B7antibody against HLA-B7 antigen,which ensures minimal cross reac-tivity thus reducing the number offalse positives. The result: higherSpecicity. The reagent usesbuilt-in intensity controls in each
test making the assay highly ro-
bust and independent of externalstandards.
Regulatory Status
ReaMetrix Reagents conform tohighest international standardsof quality. Most of the diagnosticreagents are CE marked and/orFDA cleared. For details, pleasecontact us.
-
8/14/2019 ReaMetrix Product Catalog 2010
5/10
Reagents forResearch Use
25347-00 Anti CD3-Atto488/CD4-
PE-DyLight 594/CD8-PE/CD45-PerCP Reagent
Dry RoomTemperature
50For determining ALC, percentages and absolutecounts of human total T, helper/inducer
& Suppressor/cytotoxic T lymphocytes inerythrocyte-lysed whole blood on BeckmanCoulter 4 colour EPICS-XL Instrument
25384-00 Anti CD45-Atto 488/ CD4-PE reagent
Dry RoomTemperature
50For determining ALC, percentages and absolutecounts of human helper/inducer T lympho-cytes in erythrocyte-lysed whole blood
25348-00Anti CD41-Atto488 &CD61-Atto488 reagentwith AbsoluteCounting Beads
DryRoom
Temperature50For determining absolute counts of human
platelets in stained-xed whole blood
25387-00 7-Amino-actinomycin D( 7-AAD) nucleic acid dyeready-to-use solutionwith Absolute CountingBeads
Liquid 2-8 C 25For enumeration of residual leucocytes inLeuco reduced blood products
25381-00 Anti CD235ab-Dy649/Thiazole Orange re-agent with AbsoluteCounting Beads
Dry RoomTemperature
50For determining percentages and absolutecounts of human reticulocytes and absolutecount of erythrocytes using Flow Cytometry
CatalogNumber
Product/Reagent
TypicalUsage
Format Storage KitSizes
Human Platelets Enumeration
Residual Leucocytes Enumeration
Human Reticulocyte Enumeration
HIV Immunophenotyping
-
8/14/2019 ReaMetrix Product Catalog 2010
6/10
-
8/14/2019 ReaMetrix Product Catalog 2010
7/10
Reagents for Research Use
ReaMetrix Multicolor Immunophenotyping Reagents(Leukemia-Lymphoma Panel)
ExcitationLaser (nm)
EmissionMaximum (nm)
488 488 , 532 488 , 532 488 , 532 488 595, 633,635, 647
595, 633,635, 647
488, 532, 561
523 578 618 676 678660 660
785
AntibodiesAtto-488(FITC Equivalent)
Phycoerythrin(PE)
PE-DyLight 594(PE-Texas Redequivalent)
PE-Dyomics 649(PE-Cy5 equivalent)
PerCP APCPE-HiLyte 750(PE-Cy7 equivalent)
APC-HiLyte 750(APC-Cy7 equivalent)
CD2
CD3
CD4CD5
CD7
CD8
CD10
CD11b
CD13
CD14
CD15
CD16
CD19
CD20
CD22
CD23
CD25
CD33
CD34
CD36
CD38
CD41
CD45
25802-01
25803-01
25804-0125805-01
25807-01
25808-01
25810-01
25811-01
25813-01
25814-01
25815-01
25816-01
25819-01
25820-01
25822-01
25823-01
25825-01
25833-01
25834-01
25835-01
25838-01
25841-01
25845-01
25802-02
25803-02
25804-0225805-02
25807-02
25808-02
25810-02
25811-02
25813-02
25814-02
25815-02
25816-02
25819-02
25820-02
25822-02
25823-02
25825-02
25833-02
25834-02
25835-02
25838-02
25841-02
25845-02
25802-08
25803-08
25804-0825805-08
25807-08
25808-08
25810-08
25811-08
25813-08
25814-08
25815-08
25816-08
25819-08
25820-08
25822-08
25823-08
25825-08
25833-08
25834-08
25835-08
25838-08
25841-08
25845-08
25802-03
25803-03
25804-0325805-03
25807-03
25808-03
25810-03
25811-03
25813-03
25814-03
25815-03
25816-03
25819-03
25820-03
25822-03
25823-03
25825-03
25833-03
25834-03
25835-03
25838-03
25841-03
25845-03
25802-04
25803-04
25804-0425805-04
25807-04
25808-04
25810-04
25811-04
25813-04
25814-04
25815-04
25816-04
25819-04
25820-04
25822-04
25823-04
25825-04
25833-04
25834-04
25835-04
25838-04
25841-04
25845-04
25802-05
25803-05
25804-0525805-05
25807-05
25808-05
25810-05
25811-05
25813-05
25814-05
25815-05
25816-05
25819-05
25820-05
25822-05
25823-05
25825-05
25833-05
25834-05
25835-05
25838-05
25841-05
25845-05
25802-06
25803-06
25804-0625805-06
25807-06
25808-06
25810-06
25811-06
25813-06
25814-06
25815-06
25816-06
25819-06
25820-06
25822-06
25823-06
25825-06
25833-06
25834-06
25835-06
25838-06
25841-06
25845-06
25802-07
25803-07
25804-0725805-07
25807-07
25808-07
25810-07
25811-07
25813-07
25814-07
25815-07
25816-07
25819-07
25820-07
25822-07
25823-07
25825-07
25833-07
25834-07
25835-07
25838-07
25841-07
25845-07
PackSizes
25 Tests100 Tests
Using its own unique dr ied down reagent technology, ReaMetrix canmix and match a ntibodies and uorophores to create specic multicol-or dried down L-L panels of reagents as per customers requirements.
-
8/14/2019 ReaMetrix Product Catalog 2010
8/10
ExcitationLaser (nm)
EmissionMaximum (nm)
488 488 , 532 488 , 532 488 , 532
523 578 618 676
AntibodiesAtto-488(FITC Equivalent)
Phycoerythrin(PE)
PE-DyLight 594(PE-Texas Redequivalent)
PE-Dyomics 649(PE-Cy5 equivalent)
CD55
CD56
CD59CD61
CD64
CD73
CD79a
CD90
CD103
CD105
CD117
HLA-DR
Kappa
Lambda
IgM
TCR
TCR
MPO
FMC7
Mouse IgG1,
Mouse IgG2a,
Mouse IgG2b,
Mouse IgG3
25855-01
25856-01
25859-01
25861-01
25864-01
25873-01
25879-01
25890-01
25903-01
25905-01
25917-01
25750-01
25751-01
25752-01
25753-01
25754-01
25755-01
25756-01
25757-01
25758-01
25759-01
25760-01
25761-01
25855-02
25856-02
25859-02
25861-02
25864-02
25873-02
25879-02
25890-02
25903-02
25905-02
25917-02
25750-02
25751-02
25752-02
25753-02
25754-02
25755-02
25756-02
25757-02
25758-02
25759-02
25760-02
25761-02
25855-08
25856-08
25859-08
25861-08
25864-08
25873-08
25879-08
25890-08
25903-08
25905-08
25917-08
25750-08
25751-08
25752-08
25753-08
25754-08
25755-08
25756-08
25757-08
25758-08
25759-08
25760-08
25761-08
25855-03
25856-03
25859-0325861-03
25864-03
25873-03
25879-03
25890-03
25903-03
25905-03
25917-03
25750-03
25751-03
25752-03
25753-03
25754-03
25755-03
25756-03
25757-03
25758-03
25759-03
25760-03
25761-03
488 595, 633,635, 647
595, 633,635, 647
488, 532, 561
678660 660
785
PerCP APCPE-HiLyte 750(PE-Cy7 equivalent)
APC-HiLyte 750(APC-Cy7 equivalent)
25855-04
25856-04
25859-0425861-04
25864-04
25873-04
25879-04
25890-04
25903-04
25905-04
25917-04
25750-04
25751-04
25752-04
25753-04
25754-04
25755-04
25756-04
25757-04
25758-04
25759-04
25760-04
25761-04
25855-05
25856-05
25859-05
25861-05
25864-05
25873-05
25879-05
25890-05
25903-05
25905-05
25917-05
25750-05
25751-05
25752-05
25753-05
25754-05
25755-05
25756-05
25757-05
25758-05
25759-05
25760-05
25761-05
25855-06
25856-06
25859-0625861-06
25864-06
25873-06
25879-06
25890-06
25903-06
25905-06
25917-06
25750-06
25751-06
25752-06
25753-06
25754-06
25755-06
25756-06
25757-06
25758-06
25759-06
25760-06
25761-06
25855-07
25856-07
25859-07
25861-07
25864-07
25873-07
25879-07
25890-07
25903-07
25905-07
25917-07
25750-07
25751-07
25752-07
25753-07
25754-07
25755-07
25756-07
25757-07
25758-07
25759-07
25760-07
25761-07
PackSizes
25 Tests100 Tests
This concept is suited to diagnostic labs that process multiple samplessimultaneously. This approach can be used to standardize panels (anti-bodies and uorophores) across various laboratories so that there canbe an unbiased discussion of the results of immunophenotyping.
Reagents for Research Use
ReaMetrix Multicolor Immunophenotyping Reagents(Leukemia-Lymphoma Panel)
-
8/14/2019 ReaMetrix Product Catalog 2010
9/10
ReagentAccessories
CatalogNumber
Product/Reagent
TypicalUsage
Format Storage KitSizes
Accessories for Diagnostic Use
25237-00 ReaLyse lysing Solution
(10X Concentrate)
Liquid RoomTemperature
50
ml
Erythrolytic reagent intended for lysing redblood cells to enable a lyse-no wash protocol
25326-00 ReaFix
Diluent Solution)Liquid Room
Temperature
Diluent solution used for dilution of Lysingsolution & Fixative solution
25325-00 ReaFix Fixative Solution(5% Formaldehyde)
Liquid RoomTemperature
50
ml
Fixative solution intended for the xation ofcell preparations
25108-00 ReaFlow Liquid RoomTemperature
4 cans(each 5 l)
Buered sheath uid meant for use on mostow cytometer systems.
25108-00 ReaQuant Dry RoomTemperature
25
Tests
Assay control reagent kit that includes Low,Medium, and High control beads (and ifneeded Zero control bead tube) for use insetting up the BD FACSCount instrument andchecking linearity.
50
ml
-
8/14/2019 ReaMetrix Product Catalog 2010
10/10
OtherServices
Design of Research Reagents
Custom Conjugation Services
Custom Cell Line Development Services
Bead Based FLISA Assay
Bead Based FLISA for Quantita-tive Estimation of Antigen Con-centrations by Flow Cytometrytechnique
ReaMetrix oers customconjugation services inAntibody, proteins,Chemokines, micro andnanosphere conjugations with
uorophores andQuantum dots
ReaMetrix oers development
of stable cell lines expressingprotein of interest at high,homogenous levels
Detection of PCR Products onFlow Cytometry AssayQualitative Detection of PCRProducts on Flow Cytometry
ReaMetrix can customize Antibody-Dye combinations to meet yourrequirements
We provide a completedevelopment solution from, thecloning of novel genes into suitableexpression vectors, transfectionoptimization, stable clone isolation