Realigning and Unwarping MfD - 2009 Idalmis Santiesteban Karen Hodgson.

30
Realigning and Unwarping MfD - 2009 Idalmis Santiesteban Karen Hodgson

Transcript of Realigning and Unwarping MfD - 2009 Idalmis Santiesteban Karen Hodgson.

Realigning and Unwarping MfD - 2009

Idalmis Santiesteban Karen Hodgson

SpatialNormalisation

fMRI time-series

Smoothing

Anatomical Reference

Statistical Parametric Map

Parameter Estimates

General Linear Model

Design matrix

Overview of SPM Analysis

MotionCorrection

Overview

• Motion in fMRI− Motion Prevention− Motion Correction

• Realignment – Two Steps− Registration− Transformation

• Realignment in SPM

• Unwarping

Motion in fMRI

➠ Minimising movements is one of the most important factors for ensuring good data quality

• We want to compare the same part of the brain across time

• Subjects move in the scanner

• Even small head movements can be a major problem:− Movement artefacts add up to the residual variance and reduce

sensitivity– Data may be lost if sudden movements occur during a single

volume– Movements may be correlated with the task performed

Motion Prevention in fMRI

1. Constrain the volunteer’s head

2. Give explicit instructions to remain as calm as possible, not to talk between sessions, and swallow as little as possible

3. Do not scan for too long – everyone will move after while!

Realignment - Two Steps

Realignment (of same-modality images from same subject) involves two stages:

1.Registration− Estimate the 6 parameters that describe the rigid body

transformation between each image and a reference image

2. Transformation− Re-sample each image according to the determined

transformation parameters

1. Registration

• Each transform can be applied in 3 dimensions

• Therefore, if we correct for both rotation and translation, we will compute 6 parameters

YawRoll

Translation Rotation

X

Y Z

Pitch

1. Registration

• Operations can be represented as affine transformation matrices:

x1 = m1,1x0 + m1,2y0 + m1,3z0 + m1,4

y1 = m2,1x0 + m2,2y0 + m2,3z0 + m2,4

z1 = m3,1x0 + m3,2y0 + m3,3z0 + m3,4

1 0 0 Xtrans

0 1 0 Ytrans

0 0 1 Ztrans

0 0 0 1

1 0 0 0

0 cos() sin() 0

0 sin() cos() 0

0 0 0 1

cos() 0 sin() 0

0 1 0 0

sin() 0 cos() 0

0 0 0 1

cos() sin() 0 0

sin() cos() 0 0

0 0 1 0

0 0 0 1

Translations

Pitchabout X axis

Rollabout Y axis

Yaw about Z axis

Rigid body transformations parameterised by:

Realignment (of same-modality images from same subject) involves two stages:

1.Registration− Estimate the 6 parameters that describe the rigid body

transformation between each image and a reference image

2. Transformation− Re-sample each image according to the determined

transformation parameters

2. Transformation

• Reslice a series of registered images such that they match the first image selected onto the same grid of voxels

• Various methods of transformation / interpolation:− Nearest neighbour− Linear interpolation− B-Spline

• Nearest neighbour−Takes the value of the

closest voxel

• Tri-linear−Weighted average of the

neighbouring voxels* f5 = f1 x2 + f2 x1

* f6 = f3 x2 + f4 x1

* f7 = f5 y2 + f6 y1

Simple Interpolation

B-spline Interpolation

B-splines are piecewise polynomials

A continuous function is represented by a linear combination of basis functions

2D B-spline basis functions of degrees 0, 1, 2 and 3

B-spline interpolation with degrees 0 and 1 is the same as nearest neighbour and bilinear/trilinear interpolation.

Realignment in SPM - Options

Residual Errors in Realigned fMRI

Even after realignment a considerable amount of the variance can be accounted for by effects of movement

This can be caused by e.g.:

1. Movement between and within slice acquisition

2. Interpolation artefacts due to resampling

3. Non-linear distortions and drop-out due to inhomogeneity of the magnetic field

➠ Incorporate movement parameters as confounds in the statistical model

Unwarping

Non-linear distortions due to inhomogeneities in the magnetic

field

Why we need unwarp...

• Realignment deals with any linear shifts• But after realignment there are still significant

levels of variance resulting from subject movement within the scanner.

• These will reduce the sensitivity to detect “true” activations especially if movements correlate with the task (e.g. speech etc)

Image distortions• The image that you acquire is a distorted image of the

object in the scanner.• This is because the magnetic field is affected by

differences in tissue composition across the brain• The image is particularly distorted at air-tissue

interfaces (so orbitofrontal cortex and the regions of the temporal lobe).

• The level of distortion can be increased with higher readout times (e.g. in higher resolution sequences) and higher field strengths .

• This is important as severe distortions can lead to signal loss.

Deformation fields

• To model the distortions in a single image, you can use a deformation field.

For an undistorted image....

• In SPM you can use the FieldMap toolbox to model this deformation field.

Raw EPI Undistorted EPI

However the distortions vary with movement

• The image we obtain is a distorted image• There will be movements within the scanner.• The movements interact with the distortions.• Therefore changes in the image as a result of

head movements do not really follow the rigid body assumption: the brain may not alter as it moves, but the images do.

To demonstrate...• Distortions vary with the object position• Original vs rotated deformation vectors vary• Linear translation of rotated onto original: non-rigid

body.

So given that distortions vary as the subject moves, how can we correct

for motion artefacts?

Unwarp can estimate changes in distortion from movement

• Using:– distortions in a reference image (FieldMap)– subject motion parameters (that we obtain in realignment)– change in deformation field with subject movement

(estimated via iteration)• To give an estimate of the distortion at each time point.

Resulting field map at each time point

Measured field map

Estimated change in field wrt change in

pitch (x-axis)

Estimated change in field wrt change

in roll (y-axis)

= + +00

Estimate movement parameters

Estimate new distortion fields for each image:

estimate rate of change of the distortion field with respect to the movement parameters.

Measure deformation field (FieldMap).

Unwarp time series

0B 0B

+

So hopefully you understand that...

• Tissue differences in the brain distort the signal, giving distorted images

• As the subject moves, the distortions vary• Therefore images do not follow the rigid-body

assumption.• Unwarp estimates how these distortions

change as the subject moves

Practicalities• Unwarp is of use when variance due to

movement is large. • Particularly useful when the movements are task

related as can remove unwanted variance without removing “true” activations.

• Can dramatically reduce variance in areas susceptible to greatest distortion (e.g. orbitofrontal cortex and regions of the temporal lobe).

• Useful when high field strength or long readout time increases amount of distortion in images.

Many thanks to Chloe Hutton for her invaluable help