RCX Reciprocating Compressor Analyzer · RCX-Reciprocating Compressor Analyzer 85 -264 Vac @ 47 -63...

4
SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com Multi-channel system for reciprocating compressors diagnostics in Hazardous Area (ATEX Approved) RCX- Reciprocating Compressor Analyzer Portable Multichannel (up to 16 chs) Hazardous Area approved (Ex nA e i IIC T3) Stand-alone recording Wireless connection to PC On-machine collecting data The RCX System Ex ia sensors Up to 12 Dynamic pressure probes IEPE Accelerometers Velocimeters Tacho probe (i.e. optical, magnetic and inductive probe) Reciprocating compressors are often some of the most critical systems at a production facility. Due to many factors, adequacy of maintenance practices and operational factors, industrial fa- cilities can expect widely varying lifecycle costs and reliability from their own installations. With RCX the diagnostic will be easy !

Transcript of RCX Reciprocating Compressor Analyzer · RCX-Reciprocating Compressor Analyzer 85 -264 Vac @ 47 -63...

Page 1: RCX Reciprocating Compressor Analyzer · RCX-Reciprocating Compressor Analyzer 85 -264 Vac @ 47 -63 Hz Ex -i sensors No Ex -i Sensors Zone 0 Zone 1 Zone 2 Wireless access point Power

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Multi-channel system for reciprocating compressors diagnostics in

Hazardous Area (ATEX Approved)

RCX- Reciprocating Compressor Analyzer

• Portable

• Multichannel (up to 16 chs)

• Hazardous Area approved (Ex nA e i IIC T3)

• Stand-alone recording

• Wireless connection to PC

• On-machine collecting data

The RCX System

• Ex ia sensors

• Up to 12 Dynamic pressure probes

• IEPE Accelerometers

• Velocimeters

• Tacho probe (i.e. optical, magnetic

and inductive probe)

Reciprocating compressors are often some of the most critical systems at a production facility.

Due to many factors, adequacy of maintenance practices and operational factors, industrial fa-

cilities can expect widely varying lifecycle costs and reliability from their own installations.

With RCX the diagnostic will be easy !

Page 2: RCX Reciprocating Compressor Analyzer · RCX-Reciprocating Compressor Analyzer 85 -264 Vac @ 47 -63 Hz Ex -i sensors No Ex -i Sensors Zone 0 Zone 1 Zone 2 Wireless access point Power

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Hardware and Software features

Smart setup

• Dedicated user interface

• Sensors database manager

• Multi-measurement sets managment

• Automatic dead center detection

Real time analysis

• Angle, stroke and volume domain vi-sualization for cylinder pressure

• Time and frequency domain visualiza-tion for vibration and pressure

• Valve cover temperature collection

• Valve cover vibration analysis

• Performance paramaters calculation

• Overlay of theoretical cycle

Recorded data

• Cylinder pressure (indicated cycle)

• Suction and discharge pressure

• High Freqeuncy Vibration

• Rod-drop and run-out

RCX- Reciprocating Compressor Analyzer

85-264 Vac @ 47-63 Hz

Ex-i sensors

No Ex-i Sensors

Zone 0

Zone 1

Zone 2

Wireless access point

Power supplies(to 24Vdc and to 12 Vdc)

RS232 from datalogger

Data Acquisition system

Ex-i sensors

TBSafety

barriers

Page 3: RCX Reciprocating Compressor Analyzer · RCX-Reciprocating Compressor Analyzer 85 -264 Vac @ 47 -63 Hz Ex -i sensors No Ex -i Sensors Zone 0 Zone 1 Zone 2 Wireless access point Power

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

Software features

DIAGNOSTIC PERFORMANCE

• Cylinder and Piping Pulsations

• Mechanical Looseness

• Leaking Valves and Rings

• Excessive Valve Losses and Deficien-

cies

• Passage Flow Restrictions

• Defective Unloaders

• Clearance Discrepancies

• Horsepower and Capacity Variances

Data post-processing

• Playback mode

• Re-editable setup and data update

• Multi domain visualization (angle,

stroke, volume time, frequency)

• Performance paramaters calculation

(compression ratio, theoretical and

measured volume efficiency, clearean-

ce, capacty, etc.).

• Data export

RCX- Reciprocating Compressor Analyzer

Page 4: RCX Reciprocating Compressor Analyzer · RCX-Reciprocating Compressor Analyzer 85 -264 Vac @ 47 -63 Hz Ex -i sensors No Ex -i Sensors Zone 0 Zone 1 Zone 2 Wireless access point Power

SINT Technology s.r.l. Tel: +39.055.8826302 · Fax: +39.055.8826303 · [email protected] · www.sintechnology.com

RCX- Reciprocating Compressor Analyzer

Technical specifications

Acquisition modules

Channels 1-12

Input range ±10 V

Resolution 24-Bit

Sample rate 50 kS/s/ch

Filters antialias filter

Channels 13-16

Input range ±10 V

Resolution 16-Bit

Sample rate 500 kS/s/ch

Note: the bandwidth of the channel is limited by the corresponding safety barrier, if present

WLAN Interface

Standards IEEE 802.11a/b/g/h for Wireless LAN

Operating Channels (central frequency)

2.412 to 2.472 GHz (13 channels) - 5.18 to 5.24 GHz (4 channels)

Physical Characteristics

Housing glass-fiber reinforced duroplastic polyester, with hinged door

Ingress protection IP66 to EN60529

Weight 13 kg

Dimensions 405 x 305 x 202 mm (excluding the glands)

Power Requirements

Input Voltage 110-230 Vac @ 47-63 Hz

Power Consumption 120 W

Approvals

ATEX (Ex nA e i IIC T3)