15
Line Drawing Features Input [email protected] www.raritan.com Model Number: PX2-1190R 1 Raritan PX Model Number: PX2-1190R Energy Metering Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), Power Factor Metering Accuracy ISO/IEC 62053-21 1% Metering per Input Line Yes Metering per Branch Circuit Breaker Yes Metering per Output Receptacle No Remote Outlet Switching No Environmental Sensor Ready Yes Networking 10/100 BaseT Ethernet. Optional WiFi (802.11a/b/g/n) Remote Management HTTP(s); SSH; Telnet; RS-232 (Serial); Power IQ; SNMP version v2/v3; SMTP; JSON-RPC Cascading Yes up to (4) PDUs in a single cabinet can share a single Ethernet connection Onboard Display 3-digit user-selectable display (can be selected between Manual and Auto Display Mode). Can display Line voltage, Line current, CB Current (if IPDU supports CBs) and Unit active power Compatible Sensors Temperature, Humidity, Air Flow, Static Pressure Single cable connection provides temp/humidity monitoring at three points in cabinet (with a single sensor assembly) Input Plug IEC60309 2P3W 16A (L1/L2/E) IP44("splashproof") (230V, Single phase) Cord Length 3 meters (9.84 feet) standard Cord Entry Terminal block Cable Type 2P 3W Number of Power Cords 1 Maximum Input Current 16A (per line) Nominal Input Voltage 230V, Single phase Rated Input Voltage 200 - 240V, Single phase Input Frequency 50/60Hz Power Capacity 3.2kVA at 200V, 3.8kVA at 240V

Transcript of Raritan PX Model Number: PX2-1190R Line Drawing Features · Input Plug IEC60309 2P3W 16A (L1/L2/E)...

  • Line Drawing

    Features

    Input

    [email protected]

    Model Number: PX2-1190R1

    Raritan PXModel Number: PX2-1190R

    Energy Metering Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), PowerFactor

    Metering Accuracy ISO/IEC 62053-21 1%

    Metering per Input Line Yes

    Metering per Branch Circuit Breaker Yes

    Metering per Output Receptacle No

    Remote Outlet Switching No

    Environmental Sensor Ready Yes

    Networking 10/100 BaseT Ethernet. Optional WiFi (802.11a/b/g/n)

    Remote Management HTTP(s); SSH; Telnet; RS-232 (Serial); Power IQ; SNMP version v2/v3; SMTP; JSON-RPC

    Cascading Yesup to (4) PDUs in a single cabinet can share a single Ethernet connection

    Onboard Display3-digit user-selectable display (can be selected between Manual and Auto DisplayMode).Can display Line voltage, Line current, CB Current (if IPDU supports CBs) and Unitactive power

    Compatible SensorsTemperature, Humidity, Air Flow, Static PressureSingle cable connection provides temp/humidity monitoringat three points in cabinet (with a single sensor assembly)

    Input Plug IEC60309 2P3W 16A (L1/L2/E) IP44("splashproof")(230V, Single phase)

    Cord Length 3 meters (9.84 feet) standard

    Cord Entry Terminal block

    Cable Type 2P 3W

    Number of Power Cords 1

    Maximum Input Current 16A (per line)

    Nominal Input Voltage 230V, Single phase

    Rated Input Voltage 200 - 240V, Single phase

    Input Frequency 50/60Hz

    Power Capacity 3.2kVA at 200V, 3.8kVA at 240V

  • Output

    Physical

    Environmental

    Conformance

    Model Number: PX2-1190R2

    Nominal Output Voltage 230V

    Rated Output Voltage 200 - 240V

    Output Connections (8) IEC 60320 C13 2-pole, 3-wire; 10A

    Overload Protection N/A

    Cable Retention Raritan SecureLockTM Ready Optional retention clips are also available

    Dimensions (W x D x H) 17.3" x 5.2" x 1.7" ; 440.00mm x 133.00mm x 44.00mm

    Color Black powder coat

    Mounting Tool-less button mount

    Operating Environment 5 - 50°C (41 - 122°F)

    Operating Relative Humidity 5-95%

    Operating Elevation 0-10000ft

    Regulatory ApprovalsCanada ICES-003, Class APart 15 Class A of the FCC rulesRoHS compliant

  • Control Panel Detail

    Electrical Drawing Detail

    Model Number: PX2-1190R3

  • Mechanical Diagram

    Model Number: PX2-1190R4

  • Compatiable Sensors

    Model Number: PX2-1190R5

    Environmental

    DPX-T1 : single temperature nodeDPX-T2H2 : 2 nodes: each providing both temp + humidityDPX-T3H1 : 3 temperature nodes; one also with humidityDPX-TDP1 : temperature + differential air pressureDPX-T1AF1 : temperature + air flow sensorDPX-CC2-TR : Dual contact closure sensor

    ©2013 Raritan Inc. All rights reserved. Raritan®, Know More. Manage Smarter.TM, Dominion® and PX® are registered trademarks ortrademarks of Raritan Inc. or its wholly owned subsidiaries. All others are registered trademarks or trademarks of their respective owners.For more information, please visit www.raritan.com

  • Line Drawing

    Features

    Input

    [email protected]

    Model Number: PX2-14861

    Raritan PXModel Number: PX2-1486

    Energy Metering Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), PowerFactor

    Metering Accuracy ISO/IEC 62053-21 1%

    Metering per Input Line Yes

    Metering per Branch Circuit Breaker Yes

    Metering per Output Receptacle No

    Remote Outlet Switching No

    Environmental Sensor Ready Yes

    Networking 10/100 BaseT Ethernet. Optional WiFi (802.11a/b/g/n)

    Remote Management HTTP(s); SSH; Telnet; RS-232 (Serial); Power IQ; SNMP version v2/v3; SMTP; JSON-RPC

    Cascading Yesup to (4) PDUs in a single cabinet can share a single Ethernet connection

    Onboard Display3-digit user-selectable display (can be selected between Manual and Auto DisplayMode).Can display Line voltage, Line current, CB Current (if IPDU supports CBs) and Unitactive power

    Compatible SensorsTemperature, Humidity, Air Flow, Static PressureSingle cable connection provides temp/humidity monitoringat three points in cabinet (with a single sensor assembly)

    Input Plug IEC60309 2P3W 16A (L1/L2/E) IP44("splashproof")(230V, Single phase)

    Cord Length 3 meters (9.84 feet) standard

    Cord Entry Terminal block

    Cable Type 2P 3W

    Number of Power Cords 1

    Maximum Input Current 16A (per line)

    Nominal Input Voltage 230V, Single phase

    Rated Input Voltage 200 - 240V, Single phase

    Input Frequency 50/60Hz

    Power Capacity 3.2kVA at 200V, 3.8kVA at 240V

  • Output

    Physical

    Environmental

    Conformance

    Model Number: PX2-14862

    Nominal Output Voltage 230V

    Rated Output Voltage 200 - 240V

    Output Connections (24) IEC 60320 C13 2-pole, 3-wire; 10A

    Overload Protection N/A

    Cable Retention Raritan SecureLockTM Ready Optional retention clips are also available

    Dimensions (W x D x H) 2.1" x 1.7" x 51.1" ; 52.00mm x 43.00mm x 1298.00mm

    Color Black powder coat

    Mounting Tool-less button mount

    Operating Environment 5 - 50°C (41 - 122°F)

    Operating Relative Humidity 5-95%

    Operating Elevation 0-10000ft

    Regulatory ApprovalsCanada ICES-003, Class APart 15 Class A of the FCC rulesRoHS compliant

  • Control Panel Detail

    Electrical Drawing Detail

    Model Number: PX2-14863

  • Mechanical Diagram

    Model Number: PX2-14864

  • Compatiable Sensors

    Model Number: PX2-14865

    Environmental

    DPX-T1 : single temperature nodeDPX-T2H2 : 2 nodes: each providing both temp + humidityDPX-T3H1 : 3 temperature nodes; one also with humidityDPX-TDP1 : temperature + differential air pressureDPX-T1AF1 : temperature + air flow sensorDPX-CC2-TR : Dual contact closure sensor

    ©2013 Raritan Inc. All rights reserved. Raritan®, Know More. Manage Smarter.TM, Dominion® and PX® are registered trademarks ortrademarks of Raritan Inc. or its wholly owned subsidiaries. All others are registered trademarks or trademarks of their respective owners.For more information, please visit www.raritan.com

  • Line Drawing

    Features

    Input

    [email protected]

    Model Number: PX2-14931

    Raritan PXModel Number: PX2-1493

    Energy Metering Voltage (V), Current (A), Active Power (kW), Real Power (kVA), Energy (kWh), PowerFactor

    Metering Accuracy ISO/IEC 62053-21 1%

    Metering per Input Line Yes

    Metering per Branch Circuit Breaker Yes

    Metering per Output Receptacle No

    Remote Outlet Switching No

    Environmental Sensor Ready Yes

    Networking 10/100 BaseT Ethernet. Optional WiFi (802.11a/b/g/n)

    Remote Management HTTP(s); SSH; Telnet; RS-232 (Serial); Power IQ; SNMP version v2/v3; SMTP; JSON-RPC

    Cascading Yesup to (4) PDUs in a single cabinet can share a single Ethernet connection

    Onboard Display3-digit user-selectable display (can be selected between Manual and Auto DisplayMode).Can display Line voltage, Line current, CB Current (if IPDU supports CBs) and Unitactive power

    Compatible SensorsTemperature, Humidity, Air Flow, Static PressureSingle cable connection provides temp/humidity monitoringat three points in cabinet (with a single sensor assembly)

    Input PlugIEC60309 2P3W 32A (L1/L2/E) IP44("splashproof")(230V, Single phase)

    Cord Length 3 meters (9.84 feet) standard

    Cord Entry Terminal block

    Cable Type 2P 3W

    Number of Power Cords 1

    Maximum Input Current 32A (per line)

    Nominal Input Voltage 230V, Single phase

    Rated Input Voltage 200 - 240V, Single phase

    Input Frequency 50/60Hz

    Power Capacity 6.4kVA at 200V, 7.7kVA at 240V

  • Output

    Physical

    Environmental

    Conformance

    Model Number: PX2-14932

    Nominal Output Voltage 230V

    Rated Output Voltage 200 - 240V

    Output Connections a. (20) IEC 60320 C13 2-pole, 3-wire; 10Ab. (4) IEC 60320 C19 2-pole, 3-wire; 16A

    Overload Protection (2) 20A 1-pole [Moeller] FAZ-C20/1-NA circuit breaker

    Cable Retention Raritan SecureLockTM Ready Optional retention clips are also available

    Dimensions (W x D x H) 2.1" x 2.1" x 60.6" ; 52.00mm x 53.00mm x 1539.00mm

    Color Black powder coat

    Mounting Tool-less button mount

    Operating Environment 5 - 50°C (41 - 122°F)

    Operating Relative Humidity 5-95%

    Operating Elevation 0-10000ft

    Regulatory ApprovalsCanada ICES-003, Class APart 15 Class A of the FCC rulesRoHS compliant

  • Control Panel Detail

    Electrical Drawing Detail

    Model Number: PX2-14933

  • Mechanical Diagram

    Model Number: PX2-14934

  • Compatiable Sensors

    Trip Curve of Circuit Breaker

    Model Number: PX2-14935

    Environmental

    DPX-T1 : single temperature nodeDPX-T2H2 : 2 nodes: each providing both temp + humidityDPX-T3H1 : 3 temperature nodes; one also with humidityDPX-TDP1 : temperature + differential air pressureDPX-T1AF1 : temperature + air flow sensorDPX-CC2-TR : Dual contact closure sensor

    0.0005

    rTgni

    ppi

    timt

    e]ces[

    7200

    3600

    1200

    600

    300

    120

    60

    30

    10

    5

    2

    1

    0.5

    0.2

    0.1

    0.05

    0.02

    0.005

    0.01

    0.002

    0.001

    504030201510987654321

    acc. to IEC 60898-1instantaneous tripping

    5454

    3

    12

    N

    N

    1

    2

    t

    nt

    N

    N

    N

    N

    4

    6

    N3

    I = 1.0 I (T=40 °C )

    I = 1.35 I : t < 1 h (T=25 °C )

    2.0 I : t = 12- 120 s (T=25 °C )

    10 I : t < 0.1 s

    20 I : t < 0.1 s

    conventional non-tripping current

    conventional tripping current

    type C: 5 I : t > 0.1 s

    type D: 10 I : t > 0.1 s

    tripping characteristicacc. to UL 489 / CSA 22.2 No. 235

    3

    DC

    Multiples of In

    ©2013 Raritan Inc. All rights reserved. Raritan®, Know More. Manage Smarter.TM, Dominion® and PX® are registered trademarks ortrademarks of Raritan Inc. or its wholly owned subsidiaries. All others are registered trademarks or trademarks of their respective owners.For more information, please visit www.raritan.com