Raritan Icerette : Operation and Servicing

29
Raritan Icerette : Operation and Servicing

Transcript of Raritan Icerette : Operation and Servicing

Page 1: Raritan Icerette : Operation and Servicing

Raritan Icerette : Operation and Servicing

Page 2: Raritan Icerette : Operation and Servicing

Icerette Introduction Features wrap around

evaporator coil

Produces up to 22lbs

Available in two sizes

Positive latching system

No drain required

Highest Quality marine components and hardware

Available in 120 or 240 VAC

All units assembled by hand and individually tested

One-Year Warranty

Page 3: Raritan Icerette : Operation and Servicing

Installation Mounting:

Built-in units require ¾” clearance behind unit

Proper Ventilation

Behind Door Applications

Must be secure and level

Easy removal

Page 4: Raritan Icerette : Operation and Servicing

Installation Continued… Plumbing:

Minimum 22 PSI

¼” Polyethylene Tubing

Wiring:

No extension cords

120 60HZ AC or

240 50HZ AC

Maintenance:

Vacuum condenser

Defrost when necessary

Prop door with link(IM135)

Winterization:

Do not use Anti-Freeze

Turn off water

Disconnect Water Lines

Prop door with link (IM135)

Page 5: Raritan Icerette : Operation and Servicing

Model & Serial# Identification Serial Numbers are located in two places:

Behind Grille

On back panel of unit

Provides important information

VoltageMonth/Year of

Manufacture

Compressor

Ratings

Page 6: Raritan Icerette : Operation and Servicing

Troubleshooting

Flow Diagram

Page 7: Raritan Icerette : Operation and Servicing

Icemaker Mold Ejection Process

Page 8: Raritan Icerette : Operation and Servicing

Icemaker Module Operation

Page 9: Raritan Icerette : Operation and Servicing

Icemaker Module Testing Part# I34M-1/I34M220

N = Neutral

M =Motor

H = Heater

T = ThermostatL = Line

V = Valve

Home Position 5:30

Page 10: Raritan Icerette : Operation and Servicing

Icemaker Mold Thermostat Testing Part# I34T

Thermostat

Page 11: Raritan Icerette : Operation and Servicing

Icemaker Mold Testing Part# I34MH/I34MH220

Check Resistance Check for direct short

Page 12: Raritan Icerette : Operation and Servicing

Wire Harness Testing Part#I44/I44220

Inspect Contacts

Green = Ground

Brown = Water Valve “Hot”

White = Neutral

Black = Line in

In line Fuses

Page 13: Raritan Icerette : Operation and Servicing

Cold Control Testing Part# I33A

Location Continuity Test – Normally Closed

Page 14: Raritan Icerette : Operation and Servicing

Water Solenoid Part# I34B/I34B220

Water SupplyWater to MoldLocation

Page 15: Raritan Icerette : Operation and Servicing

Condenser Fan Motor I25/I25220

Page 16: Raritan Icerette : Operation and Servicing

Compressor Components

Compressor

I1800A-1W (120)

I1800A-2W (240)

Overload

Protector

Start Relay (Set)

I1806-1 (120 VAC)

I1806-2 (240 VAC)

Page 17: Raritan Icerette : Operation and Servicing

Electrical Compressor Checks Continuity between all 3 pins

Check each pin to ground

Resistance checks

(A&B) + (A&C) = (B&C )

Example:

If A & B = 33

And A & C = 17

Then B & C will = ~50

Relay Checks

Continuity Only

A

B C

Page 18: Raritan Icerette : Operation and Servicing

Evacuation and Charging

Page 19: Raritan Icerette : Operation and Servicing

Icemaker Module Replacement I34M-1/I34M220

Page 20: Raritan Icerette : Operation and Servicing

Icemaker Thermostat Replacement Part# I34T

Page 21: Raritan Icerette : Operation and Servicing

Wire Harness Replacement Part# I44/I44220

Splice here

Page 22: Raritan Icerette : Operation and Servicing

Icemaker Mold Replacement Part# I34MH/I34MH220

Page 23: Raritan Icerette : Operation and Servicing

Frequently Asked Questions http://www.raritaneng.com/information/faq_topics/faq_icerette.html

Ice produces at a very slow rate

Cabinet has excessive frost

Icemaker does not get cold enough to freeze cubes

Water overflows ice mold cavity

Ice in bucket forms a solid block of ice

How to adjust ice cube size

Page 24: Raritan Icerette : Operation and Servicing

Contact UsRaritan Engineering Company Inc

Main Plant: Southern Office:

530 Orange Street 3101 SW Second Ave.

Millville, NJ 08332 Fort Lauderdale, FL 33315

Phone:(856)-825-4900 Phone: (954) 525-0378

Fax: (856) 825-4409 Fax: (954) 764-4370

Website: www.raritaneng.com

Sales: [email protected]

Technical Support: [email protected]

Page 25: Raritan Icerette : Operation and Servicing

Icerette Wiring Diagram

Page 26: Raritan Icerette : Operation and Servicing

Icerette Module Diagram

Page 27: Raritan Icerette : Operation and Servicing
Page 28: Raritan Icerette : Operation and Servicing

Exploded Parts View

Page 29: Raritan Icerette : Operation and Servicing