Rapid Sub-Slab Soil Gas Sampling for Finding Sources and Assessing Vapor Intrusion Martin (Mort) Schmidt, CPG-08432 Ohio Brownfield Conference, May 24, 2012

Transcript of Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006,...

Page 1: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Rapid Sub-Slab Soil Gas Sampling for Finding Sources and

Assessing Vapor Intrusion

Martin (Mort) Schmidt, CPG-08432

Ohio Brownfield Conference, May 24, 2012

Page 2: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Manufacturing Facility in Ohio w/ Tetrachloroethene (PCE) Contamination in Groundwater

New Area of Interest

PCE Decline

Persistent PCE Original Areas of Interest

Page 3: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Geologic Cross Section

Page 4: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Chlorinated Solvent Contamination

• Tetrachloroethene (PCE) above MCL of 5 ug/L

• Breakdown products, TCE & DCE in groundwater.

• Source of contamination assumed to be former PCE degreasers or ASTs.

Page 5: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Former PCE Use & Storage

Degreasers

ASTs

Page 6: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Former PCE Use & Storage

Degreasers

ASTs

Earlier Overfill

Up Gradient of Well

Page 7: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Unexpected Groundwater Contamination

PCE 97 ug/L TCE 8.6 ug/L

Page 8: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Source Investigation

• Earlier sampling inconclusive

• Recent sampling revealed unknown

source location

• Needed to locate all possible sources

Proposed to locate source with grid of subslab soil gas

Page 9: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Typical Vapor Intrusion CSM

Figure Modified After ITRC, 2007

Page 10: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Conventional Subslab Sample Point

Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R-05/147

Tubing Connections LIMITATIONS

Seal is Prone to Leak When Connecting Tubing Difficult Working Space Cement Set Up Time Extended Open Time

Page 11: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Vapor PinTM

Barbed Connection

Threaded Shoulder

Silicone Seal

Page 12: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Drilling Through Slab

Page 13: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Installing Point

Flush Mount

Stick-Up

Page 14: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Purging and Sampling

Equilibration Monitor O2 & VOCs While Purging Withdraw Soil Gas Inject Into Evacuated Glass Vials

Page 15: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Example Purge Data

0

5

10

15

20

25

4:32 PM 4:33 PM 4:34 PM 4:35 PM

Con

cent

ratio

n

Time

O2 (%)

VOCs (ppm)

Page 16: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Soil Sampling vs Soil-Gas Prospecting

• Less Obtrusive than Soil Sampling

• Real-Time Data Reduces Delays and Cost

• Soil Gas Detects Nearby Sources

Page 17: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Field Soil-Gas (PID) Results

Don’t Blame the Usual Suspects!

Black: 100-100,000 ppb, Calibrated for Isobutylene (57-57,000 ppb, when corrected for PCE) Gray: ND

Page 18: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Lab Soil-Gas Results Blue: PCE Red: TCE Yellow: cis-1,2-DCE Green : 111-TCA Gray: ND Max Total 58,000 ppb

Page 19: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Lab GC to Field PID Correlation

Page 20: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Lab Soil Results Blue: PCE Red: TCE Yellow: cis-1,2-DCE Green : 111-TCA Gray: ND Max Total 241,000 ug/kg

• Soil Data Used for Remediation • Contamination ~15 ft deep • Avoided Sampling North Half of Bldg

Page 21: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Groundwater Data Blue: PCE Red: TCE Yellow: cis-1,2-DCE Gray: ND Max Total 272 ug/L

Page 22: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Building Configuration 1924 SOIL Blue: PCE Red: TCE Yellow: cis-1,2-DCE Green : 111-TCA Gray: ND Max Total 241,000 ug/kg

Page 23: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Building Configuration 1938 SOIL Blue: PCE Red: TCE Yellow: cis-1,2-DCE Green : 111-TCA Gray: ND Max Total 241,000 ug/kg

Manufacturing Started in 1933

Page 24: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Building Configuration 1950 SOIL Blue: PCE Red: TCE Yellow: cis-1,2-DCE Green : 111-TCA Gray: ND Max Total 241,000 ug/kg

Page 25: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Building Configuration 1952 SOIL Blue: PCE Red: TCE Yellow: cis-1,2-DCE Green : 111-TCA Gray: ND Max Total 241,000 ug/kg

Contamination Probably Between 1933 and 1952

Page 26: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Building Configuration 2012 SOIL Blue: PCE Red: TCE Yellow: cis-1,2-DCE Green : 111-TCA Gray: ND Max Total 241,000 ug/kg

Page 27: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Benefits

• Low Costs Enable Dense Sampling Grid • Low Risk of Missing Sources • No Interruption to Plant Operations • Reduced Time Before Remediation • Faster, More Quantitative than Passive Sorbents • Sample Points Reusable • Applicable to Vapor Intrusion – Draft SOP by MI DEQ

• (Vapor PinsTM are Commercially Available)

Page 28: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Pick Two!

Good

Fast

Cheap Cheap

MOST STUFF VAPOR INTRUSION

Are You Kidding?

Are You Kidding?

We Obsess on Good at the Expense of Complete

Complete

Good

Page 29: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Comparison of Results from Vapor PinsTM & SwagelokTM Fittings, Michigan DEQ

Data Collected with Michigan DEQ. Includes Multiple Dates, Labs, Container Types, & Analytes. Excludes VI-12.

Page 30: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Comparison of Results from Vapor PinsTM to Permanent Implants, H&P Labs, California

Samples Collected Over 2 Days (Acetone removed)

Page 31: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Innovative Soil-Gas Sampling

QUESTIONS?

Page 32: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

O2 Concentrations Don’t Suggest Leakage

Gray: Sample Point Black: Least O2 Depletion

Page 33: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Manufacturing Facility in Northern Ohio

Work Plan Showed 14 Suspected Source Areas. Existing Soil Data Didn’t Match Groundwater Plumes

Page 34: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

248 Soil-Gas Samples 40 feet Grid at 5 feet Below Grade

Soil Gas via GeoprobeTM & Vials

Page 35: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Once Again, Not the Usual Suspects

CI = 5,000 ppb Total HVOCs

Page 36: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Problems with Conventional Subslab Points

• “Compression fittings should be avoided for all connections except at the Summa canister…” Soil Gas Sampling Protocol, Missouri Risk-Based Corrective Action Technical Guidance, 2006.

• “Some leakage may occur despite the investigator’s best efforts to seal the gap between the sampling probe and the slab hole…” Guidance for Evaluating Soil VI in WA State, Investigation and Remedial Action, Draft, October 2009.

• “7.3.1 If the probe assembly breaks loose from the anchoring compound while removing or installing the hex socket plug…” Vapor Intrusion Guidance, Ohio EPA, May, 2010.

• “Only two probes were sampled using EPA Method TO-15 because one probe P[B], became loose during sampling…” DiGiulio et al., 2006, EPA Raymark Investigation.

Page 37: Rapid Sub-Slab Soil Gas Sampling for Finding Sources and ... · Figure from DiGiulio et al., 2006, Raymark Investigation, EPA/600/R -05/147 Tubing Connections LIMITATIONS Seal is

Background VOCs

Figure from USEPA 2011, Background Indoor Air Concentrations, EPA /530/R-10/001