Radon and variable rock stress
description
Transcript of Radon and variable rock stress
Radon and variable rock stress
Radon variations in an underground galleryPumping Storage Facility, SEO, L-Vianden
Francis Massen, Physics Lab, Lycée Classique DiekirchAntoine Kies, LPR, Université du Luxembourg
2
basin 1
basin 2
Upper basins 1 & 2
3
Construction : 1959 to 1964Maximum used volume of basins : 6.8 million m3
Maximum water level change : 16 m ~ 1.6 atFlow during power generation : 432.5 m3/sMean daily power generation time: 4.25hMean daily pumping time: 7.25h
www.seo.lu
SEO main figures:
4
Water outlets
5
B1_stat2 B1_stat1 B1_stat3B2_stat1 B2_stat2
Location of stations
galleries
B2_stat3( in use since July04)
6
Geology
basin1
basin2
7
Fractures and fillings (J. Bintz, 1964)
Voids were filled with concreteduring construction work!
8
Interior of gallery
9
Boreholes
1m concrete
40cm rock
~16cm diameter
10
21Nov02 – 13Dec02, 4 stations [100uRoe/h ~1uSv/h ~100 Bq/m3 EER]Difference in radon signal between basin1 and basin2
11
May02
Possible anticorrelation with atmospheric pressure …. large voids in underground?
Basin1, station1: influence of atmospheric pressure variations
12
Basin2 stat1: radon and water level (station1, 21Nov02-13Dec02)
13
Basin2 stat2: radon and water level (station2, 02 – 30 Apr.04)
14
Basin2: stations 1,2,3 : 04Aug-27Sep 2004Vanishing signal….
stat1
stat2
stat3
190m
245m
approx.direction offissures
24h
why?
Autocorrelation of radon
15
Gravitational effects
stat1stat2stat3
16
Water level modulates existing radon background
Emptying basin 2: radon regains background level in ~24h
24 hours
17
21Nov02 - 13 Dec02Time lag between radon and water level: Basin2, station1
18
21Nov02 - 13 Dec02
Time lag between radon and water level: Basin2, station2
19
Is the delay between radon and water level ~ constant?…. YES!
20
More time lags between radon and water level:
from…to days B2stat1 B2stat2 B2stat3
21Nov02-05Feb03 77 93 24612-18Jun03 7 36 26302-30Apr04 29 109 27804Aug-27Sep04 55 205 240 (300)______________________________________________________
? ?
21
Relation between radon concentration and water level: B2 stat1
22
Better fit: parabolic
23
Relation between radon concentration and water level: B2 stat2
24
Explication?
stat1
stat2
stat3
B1_stat3
Stations 1 and 2 lie in a fissuresystem with one dominatingorientation preferentialmigration path for radon strong water level dependance
Fissure system is random: no dominant migration path no water level dependance
Basin 1
Basin 2
25
RM80 Aware counter
“Pancake” Geiger tube (,,)
Sensor driven by serial or parallelport of (notebook) computer
Sensor is not waterproof: usually will be sealed in PET bag with calcium chloride CaCl2 as desiccant.
Many humidity related problems!
Price: ~319 US$www.aw-el.com
26
Calibration of RM80
Calibration was done in-situ , (in gallery with no ventilation)comparing readings of a RM80 and a Alphaguard:
borehole
27
RM80 and Radim sensor (borehole B2 stat2)
28
Computer problems
1. Protection against humidity: never shut down!2. Protection against fine dust: seal floppy drive by tape; install Laplink in case of floppy malfunction3. Use only notebooks: power outage protection!4. Save backlight tubes: shut off screen5. Use surge protectors (many lightning impacts!)6. Combat computer clock drift: RIGHTIME software
7. Use only old equipment!
29
Software
Very large data files ( > 150000 lines): use DADiSP
30
DADiSP www.dadisp.com
Price: 1995 US$
Same as full version,limited in numberof windows and datasize
31
Merci de votre attention…
[email protected] [email protected]@bigfoot.com
http://meteo.lcd.lu/papers/http://www.speleo.lu