Transcript of Radio immuno assay
![Page 1: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/1.jpg)
RADIOIMMUNOASSAYRADIOIMMUNOASSAY
Presented by:Chakravarthy.RY10MPH1203
Guided by:Dr. Abdul Rehaman Asst prof M.ph.,PhD.,
PHARMACEUTICS
NIRMALA COLLEGE OF PHARMACY
![Page 2: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/2.jpg)
The technique was introduced in 1960 by Berson and Yalow as an assay for the concentration of insulin in plasma.
It represented the first time that hormone levels in the blood could be detected by an invitro assay.
Dr. Rosalyn Yalow became the firstfemale to win a Nobel Prize withher work on the radioimmunoassay
HISTORY
![Page 3: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/3.jpg)
ANTIGENSANTIGENSAn antigen is a substance with the ability to
induce an immunological response. They
typically enter the body from an infection.
They are recognized at their epitopes by B
cells or by the T cell receptor on T cells.
Proteins or glycoproteins make the best
antigens because they are the best at
stimulating antigen recognition molecules.
Some immunoassays test for antigens, rather
than antibodies.
![Page 4: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/4.jpg)
![Page 5: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/5.jpg)
ANTIBODIESANTIBODIES
• Antibodies are produced by the
B-lymphocytes. They are glycoproteins
belonging to the “immunoglobulin supergene
family” that are produced in response to a
foreign substance in the body.
• Antibodies have a generally common structure,
but have regions that vary among them to
accommodate the specific antigens.
![Page 6: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/6.jpg)
![Page 7: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/7.jpg)
PRODUCTION OF PRODUCTION OF ANTIBODIESANTIBODIES
Polyclonal antibodies are more likely to
produce a false positive because they are less
specific to antigen epitopes and have varying
binding affinities.
◦ A mouse (or rabbit) is immunized by being
injected with an antigen; the antigen
generates an antibody response in the animal.
◦ The animal is bled and the antibodies are
collected.
![Page 8: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/8.jpg)
LABELS IN LABELS IN IMMUNOASSAYSIMMUNOASSAYS
Immunoassays require the use of labeled materials in order to measure the amount of antigen or antibody present. A label is a molecule that will react as part of the assay, and in doing so produce a signal that can be measured in the solution. Examples of a label include a radioactive compound, or an enzyme that causes a change of color in a solution or its fluorescence .
![Page 9: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/9.jpg)
PRINCIPLEPRINCIPLE
Radioimmunoassay (RIA) involves the separation of a protein (from a mixture) using the specificity of antibody - antigen binding and quantitation using radioactivity.
![Page 10: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/10.jpg)
Radioimmunoassay (RIAs) utilize a radioactive label (usually 125I, 3H or 14C), which emits radiation that can be measured with a beta or gamma counter.
![Page 11: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/11.jpg)
The technique of radioimmunoassay has revolutionized research and clinical practice in many areas, e.g.,
◦blood banking
◦diagnosis of allergies
◦endocrinology
![Page 12: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/12.jpg)
THE TECHNIQUETHE TECHNIQUE
A mixture is prepared of ◦radioactive antigen Because of the ease with which iodine
atoms can be introduced into tyrosine residues in a protein, the radioactive isotopes 125I or 131I are often used.
◦antibodies against that antigen.
Known amounts of unlabeled ("cold") antigen are added to samples of the mixture. These compete for the binding sites of the antibodies.
![Page 13: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/13.jpg)
At increasing concentrations of unlabeled antigen, an increasing amount of radioactive antigen is displaced from the antibody molecules.
The antibody-bound antigen is separated from the free antigen in the supernatant fluid, and the radioactivity of each is measured.
![Page 14: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/14.jpg)
![Page 15: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/15.jpg)
Gamma Counter
![Page 16: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/16.jpg)
CALIBRATION CURVECALIBRATION CURVE
From these data, a standard binding curve, like thee one shown in red, can be drawn.
The samples to be assayed (the unknowns) are run in parallel.
![Page 17: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/17.jpg)
After determining the ratio of bound to free antigen in each unknown, the antigen concentrations can be read directly from the standard curve.
![Page 18: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/18.jpg)
SEPARATING BOUND FROM SEPARATING BOUND FROM FREE ANTIGENFREE ANTIGEN
Precipitate the antigen-antibody complexes by adding a "second" antibody directed against the first.
For example, if a rabbit IgG is used to bind the antigen, the complex can be precipitated by adding an antirabbit-IgG antiserum (e.g., raised by immunizing a goat with rabbit IgG).
![Page 19: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/19.jpg)
ADVANTAGESADVANTAGES
Radioimmunoassay is widely-used because of its great sensitivity.
Using antibodies of high affinity, it is possible to detect a few pictograms (10−12 g) of antigen in the tube.
The greater the specificity of the antiserum, the greater the specificity of the assay
![Page 20: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/20.jpg)
RIA has become a major tool in the clinical laboratory where it is used to assay .
plasma levels of: ◦most of our hormones; ◦digitoxin or digoxin in patients receiving
these drugs; ◦certain abused drugs.
Presence of hepatitis B surface antigen (HBsAg) in donated blood.
Anti-DNA antibodies in systemic lupus erythematosus (SLE).
![Page 21: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/21.jpg)
Screening donated blood for evidence
of viral contamination by ◦ HIV-1 and HIV-2 (presence of anti-HIV antibodies) ◦ Hepatitis C (presence of antibodies) ◦ Hepatitis B (testing for both antibodies and a viral
antigen) Measuring hormone levels
◦HCG (as a test for pregnancy)
APPLICATIONSAPPLICATIONS
![Page 22: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/22.jpg)
Negative :
Positive:
![Page 23: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/23.jpg)
◦LH (Luteinizing hormone , determining the time of ovulation)
◦TSH, T3 and T4 (for thyroid function) ◦Hormones (e.g., anabolic steroids, HGH)
that may have been used illicitly by athletes.
Detecting infections ◦sexually-transmitted agents ◦like HIV, syphilis, and chlamydia ◦hepatitis B and C ◦Toxoplasma gondii
![Page 24: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/24.jpg)
Detecting allergens in food and house dust .
RAST:
The radioallergosorbent test to detect specific IgE antibodies to suspected or known allergens . IgE is the antibody associated with type I allergic response : Pollen (is a fine to coarse powder containing the microgamatophytes of seeds)
The amount of radioactivity is proportional to the serum IgE for the allergen.
![Page 25: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/25.jpg)
RAST rating
IgE level (KU/L)
COMMENT
0 < 0.35Absent or undetectable allergen
specific IgE
1 0.35 - 0.69 Low level of allergen specific IgE
2 0.70 - 3.49 Moderate level of allergen specific IgE
3 3.50 - 17.49 High level of allergen specific IgE
4 17.50 - 49.99 Very high level of allergen specific IgE
5 50.0 - 100.00 Very high level of allergen specific IgE
6 > 100.00Extremely high level of allergen
specific IgE
![Page 26: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/26.jpg)
Measuring "rheumatoid factors" and other auto antibodies in autoimmune diseases like lupus erythematosus.
Measuring toxins in contaminated food
Detecting illicit drugs, e.g., ◦cocaine ◦opiates ◦Δ-9-tetrahydrocannabinol, the active
ingredient in marijuana
![Page 27: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/27.jpg)
Detection of drug: Detection of drug:
![Page 28: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/28.jpg)
DRAWBACKSDRAWBACKSThe main drawbacks to
radioimmunoassay are the expense and hazards if preparing and handling the radioactive antigen.
Both 125I or 131I emit gamma radiation that requires special counting equipment;
The body concentrates iodine atoms — radioactive or not — in the thyroid gland where they are incorporated in thyroxine (T4).
![Page 29: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/29.jpg)
ISOTOPESISOTOPESISOTOPE HALF-LIFE USES
Carbon-11 20.3m Brain scans
Chromium-51
27.8d Blood Volume determination
Cobalt-57 270d Measuring vitamin B12 uptake
Cobalt-60 5.26y Radiation cancer therapy
Gadolinium-153
242d Determining bone density
Gallium-67 78.1 Scan for lung tumors
Iodine-131 8.07d Thyroid therapy
Iridium-192 74d Breast cancer therapy
![Page 30: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/30.jpg)
Iron-59 45d Detection of anemia
Phosphorous-32
14.3d Detection of skin cancer or eye tumors
Plutonium-238
86y Power for pacemakers
Slenium-75 120d Pancreas scans
Sodium-24 15.0h Locating obstructions in blood flow
Technetium-99
6.0h Imaging of brain, liver, none marrow, kidney, lung or heart
Thallium-201
73h Detecting heart problems with treadmill stress test
Tritium 12.3y Determining total body water
Xenon-133 5.27d Lung imaging
![Page 31: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/31.jpg)
REFARENCES
Textbook of microbiology by Prescott, Harley.
Practical analytical chemistry by BECKEET.
http://en.wikipedia.org/wiki/Radioimmunoassay
http://en.wikipedia.org/wiki/RIAhttp://en.wikipedia.org/wiki/RAST_testhttp://www.millipore.com/
immunodetection/id3/radioimmunoassay.
![Page 32: Radio immuno assay](https://reader036.fdocuments.in/reader036/viewer/2022081417/5560e1c7d8b42afb7b8b499b/html5/thumbnails/32.jpg)
Thank“u”