Radiation Test Results
description
Transcript of Radiation Test Results
![Page 1: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/1.jpg)
Radiation Test Results
Preliminary measurements from exposure to gamma rays at SCK-CENB. Todd Huffman, C. Issever, T. Weidberg Summer Students - A. Povey, K. Dunn
Also Presented: Some SMU group tests.
![Page 2: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/2.jpg)
The active tests 50m lengths of three different Ericsson fibres
High dose only @ 850nm 50m lengths of Infinicor (Corning?) fibre
High and low dose tests @ 850nm Including results from SMU (Andy Liu)
High and low light level tests (VCSEL vs. LED) 50m length of SMF28 Single Mode fibre
@ 1310nm True for all SM tests. MM Fused Taper Splitter (1x4) SM PLCC splitter (1x4) MM and SM LC-LC connectors
![Page 3: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/3.jpg)
Test set-up: Fibre exposure
Power supply&
Measurement
Splitter
Reference
Fibre undertest
Fibre Section exposedIn rad. area
Light-sensitive diode current Measurements
Single Laser source
Optical Patch cables
Conn.
![Page 4: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/4.jpg)
Test Setup Connector-loss Test
Laser Splitter
Radiation exposure Vol.
Connector
STST
ST
ST
Patch CablesPhotodiode+Amplifier
Test channel
Reference channel
![Page 5: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/5.jpg)
Test Setup Splitter test
Laser Splitter
Radiation exposure Vol.
Splitter
STST
ST
ST
ST
Patch CablesPhotodiode+Amplifier
![Page 6: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/6.jpg)
System Stability tests
Ran system for extended time periods. Find stability
limitations Example
shown at right for Laser sources
LED sources; next slide.
![Page 7: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/7.jpg)
System Stability tests
LED light source Low light levels Highly Stable
![Page 8: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/8.jpg)
System Stability tests EEL Light
sourceSingle mode
![Page 9: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/9.jpg)
The two locations RITA BRIGITTE
![Page 10: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/10.jpg)
The sources
BRIGITTE 10cm region of highest
dose Managed to fit all
active tests into this volume
25.1kGy/hr RITA
1.12kGy/hr SMU
0.42kGy/hr 0.38kGy/hr 0.026kGy/hr
![Page 11: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/11.jpg)
Temperature in the vessel
Temperature (°C)
0.00E+00
1.00E+01
2.00E+01
3.00E+01
4.00E+01
5.00E+01
6.00E+01
7.00E+01
8.00E+01
12/08/200800:00
12/08/200812:00
13/08/200800:00
13/08/200812:00
14/08/200800:00
14/08/200812:00
15/08/200800:00
15/08/200812:00
16/08/200800:00
16/08/200812:00
Temperature (°C)
The Temperature in RITA was the same as average room temperature.
Vessel Lowered into Source
Vessel Removed
Vessel returned &Removed again.
![Page 12: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/12.jpg)
Crate Temperature
Temp. in the crate containing light sources.
![Page 13: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/13.jpg)
Single Mode Data @ 1310nm
Radiation begins Radiation Ends
Short Radiation exposure
![Page 14: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/14.jpg)
Single Mode Data
Very low attenuation levels.
![Page 15: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/15.jpg)
Graded Index Ericsson Fibres
![Page 16: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/16.jpg)
Graded Index Infinicor
![Page 17: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/17.jpg)
From SMU groupA. Liu, J. Ye
![Page 18: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/18.jpg)
![Page 19: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/19.jpg)
![Page 20: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/20.jpg)
Parameterising Infinicor Data
Function pass through zero at zero dose. 0.03 to 0.3 kGy total dose
SMU tests @ 0.42kGy/hr
0.3 kGy to 75kGy total dose Oxford tests @ 1.12kGy/hr
180.0kGy to 720kGy Oxford tests @ 25kGy/hr
In the gap between 75kGy and 180kGy Just interpolated linearly.
![Page 21: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/21.jpg)
Parameterisation Results
![Page 22: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/22.jpg)
Parameterisation results
Infinicor fibre total loss Assume typical ATLAS fibre run. Use parameterization previously found
Total loss is 0.36 dB Conservatively
![Page 23: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/23.jpg)
Loss Estimates Assume L(SLHC)= 3000 fb-1
Safety factor = 1.5 (r<110) or 5(r>110).
Fibre routing (cm) loss (dB)step rstart rend zstart zend length (cm) POF Infinicor
1 30 110 100 100 80 0.166 0.0652 110 110 100 340 240 0.428 0.1343 110 420 340 340 310 0.316 0.1314 420 420 340 0 340 0.003 0.0125 420 572 0 0 152 0.001 0.0026 circumferential step delta phi =pi, r = 572 1797 0.118 0.0057 572 1200 0 0 628 0.002 0.008
Total 35.5 1.03 0.36
![Page 24: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/24.jpg)
Which fibre is best?
Eric 1
Eric 2
Eric 3
Infinicor
![Page 25: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/25.jpg)
Infinicor Light Intensity effects
![Page 26: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/26.jpg)
Active MM Component Raw Data
Ref. Fibre Fell from top of gantry into radiation zone.
![Page 27: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/27.jpg)
Active MM Component tests
Region of exposure
![Page 28: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/28.jpg)
Single Mode LC-LC connector
![Page 29: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/29.jpg)
The Passive tests Components tested before and after
irradiation up to 720kGy. 7 fused taper splitters (1 850nm
multimode, the remainder 1310nm single-mode) with SC connectors on all in and outputs;
2 single-mode PLCC splitters with SC connectors on all in and outputs;
6 LC-LC Multimode barrels Result No damage at 0.02dB level
![Page 30: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/30.jpg)
Passive test results
Device Attenuation, dB Standard Dev., dB
7E (FT splitter SM) 0.20 0.055044
8E (FT splitter SM) 0.40 0.260118
9E (FT splitter SM) 0.41 0.065326
10E (FT splitter SM) 0.55 0.072245
11E (FT splitter SM) 0.21 0.07612
12E (FT splitter SM) 0.33 0.09783
5M (PLCC splitter SM) 4.10 0.030325
6M (PLCC splitter SM) 3.60 0.036641
6E (FT splitter MM) 1.34 0.019436
![Page 31: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/31.jpg)
A working nuclear reactor(Looking down from above)
![Page 32: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/32.jpg)
The reactor core(Side View)
![Page 33: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/33.jpg)
Clearly, there have been no discernable side effects.
![Page 34: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/34.jpg)
Conclusions
SMF-28 Single mode fibre is very rad-hard and likely sufficient for the upgrade.
Infinicor (Corning) GRIN fibre exhibits and estimated 0.36dB loss in ATLAS. This includes safety factors!
2 of the three Ericsson fibres tested well and comparable to the Infinicor fibre. Second source
Manufacturing details for all MM fibres are difficult to obtain. Passive Connector tests were highly successful; active tests less
so. Radiation damage consistent with zero (MM) or with temperature effects (SM).
Fused Taper splitter damage is all consistent with radiation damage to the optical fibre that make them up. More tests in this area may be useful.
PLCC splitters seem inordinately suseptable to ionizing radiaion. An area very much worth further exploration.
Some temperature effects will be further explored in our environmental chamber at Oxford.
![Page 35: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/35.jpg)
End Of Talk
Next Slides are backup slides
![Page 36: Radiation Test Results](https://reader035.fdocuments.in/reader035/viewer/2022062322/5681462c550346895db33b6d/html5/thumbnails/36.jpg)
Single Mode Raw Data