Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack...
Transcript of Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack...
![Page 1: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/1.jpg)
■ Marco Li
■ Structure Team
■ 20180525
Rack Server Random Vibration FEA (Femap w/ NX-Nastran)
![Page 2: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/2.jpg)
2
Agenda
� Rack Server Random Vibration Specification Introduction
� Rack Level Random Vibration Test
� Rack Level Random Vibration FEA
� Automatic Bolt API Sharing
![Page 3: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/3.jpg)
3
Scalable
Balanced
Performance Driven
Rack Server Random Vibration Specification Introduction -1
� Product Design Experience
![Page 4: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/4.jpg)
4
� Transportation
Rack Server Random Vibration Specification Introduction -2
� Specification Introduction
Customer I Customer II Customer III
Modes Truck, Air, Rail and Ocean Vibration
Grms 0.8 1.146 0.84 1.2
Test Orientations Z Z X/Y Z
Duration (min) 15 60 60 60
Highest Grms
Rail
Truck
Air
Ocean
![Page 5: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/5.jpg)
5
Rack Level Random Vibration Test
� Purpose: Verify rack server structure rigidity under random vibration input.
Rack setup on Vibe. table Testing
Case 1 – 1U rack server test (1.2 Grms) result
Case 2 – 2U rack server test (1.146 Grms) result
![Page 6: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/6.jpg)
6
Rack Level Random Vibration FEA
� Femap w/ NX-Nastran Random Response Solver
![Page 7: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/7.jpg)
7
Rack Level Random Vibration FEA – Case 1
Case 1 – 1U rack server test (1.2 Grms) result
� FEA model – Femap w/ NX-Nastran
� FEA result� Stress concentrate on the weak point, FEA
result is similar to rack test result.
Rear Wall
![Page 8: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/8.jpg)
8
Rack Level Random Vibration FEA – Case 2
� Stress concentrate on the weak point, FEA result is similar to rack test result.
Case 2 – 2U rack server test (1.146 Grms) result
� FEA model – Femap w/ NX-Nastran
� FEA result
![Page 9: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/9.jpg)
9
Solution Implement Result
� Case 1
� Case 2
Rear Wall with solution
![Page 10: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/10.jpg)
Backup
![Page 11: Rack Server Random Vibration FEA · Rack Level Random Vibration FEA – Case 1 Case 1 – 1U rack server test (1.2 Grms) result FEA model – Femap w/ NX-Nastran FEA result Stress](https://reader035.fdocuments.in/reader035/viewer/2022062216/5fbb11eeade9da27c528f838/html5/thumbnails/11.jpg)
Automatic Bolt
11
Complete:
1. Select bolt surfaces
2. Enter radius range to search curves on bolted surfaces
Next Action:
3. Automatic search multi-circles which have be bolted
together
4. Automatic fixed by each bolted
Efficiency-(15sec)Current-(41sec)
� Manual Curve Selection � Automatic Select Bolt Circle