ra29160_0405

download ra29160_0405

of 12

Transcript of ra29160_0405

  • 8/8/2019 ra29160_0405

    1/12

    RA 29160/04.05Replaces: 06.98

    Electric Drivesand Controls Hydraulics

    Linear Motion andAssembly Technologies Pneumatics Service

    Proportionalpressure relief valve,pilot operated

    Model DBE(M) and DBE(M)E

    Features 1

    Ordering code 2

    Preferred types 2

    Symbols 2

    Function, section 3

    Technical data 4 and 5

    Control electronics 5 and 6

    Electrical connection, cable sockets 5

    Characteristic curves 7

    Unit dimensions 8 and 9

    Sizes 10, 25 1)

    Component series 5XMaximum operating pressure 350 barMaximum flow 400 L/min

    1/

    Table of contents Features

    Contents Page Pilot operated valve for limiting a system pressure Operation by proportional solenoid

    For subplate mounting:Position of ports according to DIN 24340, form Esubplates according to data sheet RE 45064,(separate order, see pages 8 and 9)

    Optional maximum pressure relief function by means ospring-loaded pilot valve

    Valve and control electronics from a single source

    External control electronics for types DBE and DBEM Analogue amplifier type VT-VSPA1-1 in Euro-card

    format (separate order, see page 5) Digital amplifier type VT-VSPD-1 in Euro-card forma(separate order, see page 5)

    Amplifier type VT 11131 of modular design(separate order, see page 5)

    Integrated electronics (OBE) with types DBEE andDBEME: Low tolerances of the command value/pressure

    characteristic curve Up and down ramps can be adjusted independently

    of each other

    1) Size 32, component series 3X, see data sheetRE 29142

  • 8/8/2019 ra29160_0405

    2/12

    2/12 Bosch Rexroth Corp. | Industrial Hydraulics DBE(M) and DBE(M)E | RA 29160/04.05

    B

    X YA

    B

    X YA

    B

    YA

    B

    YA

    B

    X YA

    B

    X YA

    B

    YA

    B

    YA

    Ordering code

    Proportional pressure relief valve

    Without maximum

    pressure relief function = No codeWith maximumpressure relief function = M

    For external control electronics = No codeWith integrated electronics (OBE) = E

    Size 10 = 10Size 25 = 20

    Component series 50 to 59 = 5X(50 to 59: unchanged installation and connection dimensions)

    Pressure stage

    up to 50 bar (725 PSI) = 50up to 100 bar (1450 PSI) = 100

    up to 200 bar (2900 PSI)= 200

    up to 315 bar (4569 PSI) = 315up to 350 bar (5075 PSI) = 350

    External pilot oil drain = YUnloading port X, external pilot oil drain = XY

    Further details in clear text

    Seal material

    M = NBR seals,suitable for mineral oil

    (HL, HLP) to DIN 51524V = FKM seals

    K4 =

    Electrical connection

    for DBE; DBEM:Without cable socket, with com-ponent plug to DIN EN 175301-803

    Cable socket separateorder, see page 5

    K31 =

    for DBEE; DBEME:

    Without cable socket, with com-ponent plug to DIN EN 175201-804

    Cable socket separateorder, see page 5

    Supply voltage of electronics

    G24 = 24 V DC

    DBE 5X G24 *

    Standard types

    Size 10 Size 25

    Symbols

    Type DBEM-5X/XYType DBEM-5X/YType DBE-5X/XYType DBE-5X/Y

    Type DBEME 10 Material no.

    DBEME 10-5X/50YG24K31M R900908585

    DBEME 10-5X/100YG24K31M R900954707DBEME 10-5X/200YG24K31M R900954708

    DBEME 10-5X/315YG24K31M R900536812

    DBEME 10-5X/350YG24K31M R900941261

    Type DBEME 20 Material no.

    DBEME 20-5X/50YG24K31M R900954711

    DBEME 20-5X/100YG24K31M R900937307DBEME 20-5X/200YG24K31M R900954709

    DBEME 20-5X/315YG24K31M R900536813

    DBEME 20-5X/350YG24K31M R900954710

    Type DBEME-5X/XYType DBEME-5X/YType DBEE-5X/XYType DBEE-5X/Y

  • 8/8/2019 ra29160_0405

    3/12

    DBE(M) and DBE(M)E | RA 29160/04.05 Industrial Hydraulics | Bosch Rexroth Corp. 3/12

    BAX

    a

    a

    1 9 15 12 2

    11

    10

    86

    74

    3

    13

    5

    Y15

    14

    17

    16

    Function, section

    Schnitt aa

    Type DBEM-5X/

    with maximum pressure relief function

    13 Version "XY" with additional unload-ing port X

    14 Port Y

    external pilot oil drain,separate and at zero pressure to tank

    Type DBE-5X/XYG24K4.

    Valves of types DBE and DBEM are pilot operated pressurerelief valves. They are used to limit the pressure in hydraulicsystems.These valves can be used to infinitely adjust the pressure to belimited in relation to the electrical command value.Basically, these valves consist of a pilot valve (1) installed in a

    common housing, with proportional solenoid (2) and the mainspool insert (3).

    Type DBEThe pressure present in port A acts on the underside of the main

    spool (3). At the same time, the pressure is applied via orifice (4),ring channel (5) and orifice (6) to the spring loaded side of the

    main spool (3). The hydraulic force at the pilot poppet (12) acts

    via the radial bore (7), control bore (8) and orifice (9) against thecommand value-dependent force of the proportional solenoid (2).

    When the hydraulic force overcomes the solenoid force, the pilotpoppet (12) opens. Due to this, pilot oil can drain via port Y (14)

    to the tank and causes a pressure differential across the orifice,which acts on the main spool (3) and lifts it against the force of

    the return spring (10). The connection of ports A to B is openedand there is no further pressure increase.

    At port X (13) the valve may be unloaded or the maximum pres-sure limited.

    Type DBEM

    Optionally the valve is available with an additional spring loadedpilot valve (15) for maximum pressure limitation (redundant pres-

    sure relief function).We generally recommend the selection of this version!(When using these valves, observe the notes on page 4.)

    Type DBEE and DBEME with integrated electronics (OBE)In terms of function and design, these valves are basically the

    same as types DBE and DBEM, except for the integrated elec-

    tronics. The control electronics which is accommodated in hous-ing (16) receives the supply and command value voltages via the

    cable socket (17).The command value/pressure characteristic curve (zero pointat valve seat (11) and gradient at I

    maxpotentiometer (R30) in

    the control electronics) is factory-set with very low manufactur-ing tolerances.The ramp times for pressure build-up and reduction can be setindependently of each other using two potentiometers.For further details regarding the integrated electronics, seepages 5 and 6.

    Type DBEE-5X/G24K31...

  • 8/8/2019 ra29160_0405

    4/12

    4/12 Bosch Rexroth Corp. | Industrial Hydraulics DBE(M) and DBE(M)E | RA 29160/04.05

    Technical data (for applications outside these parameters, please consult us!)

    GeneralSize Size 10 25

    Weight DBE and DBEM kg (lb) 3.4 3.8

    DBEE and DBEME kg (lb) 3.5 3.9

    Installation orientation Optional

    Storage temperature range C (F) 20 to + 80 ( 68 to + 176)

    Ambient temperature DBE and DBEM C (F) 20 to + 70 ( 68 to + 158)

    range DBEE and DBEME C (F) 20 to + 50 ( 68 to + 122)

    Hydraulic [measured with HLP 46 at 40C 5C (104F 41F )]

    Size Size 10 25

    Max. operating pressure Ports A, B and X bar (PSI) 350

    Port Y Separate and at zero pressure to tank

    Max. set pressure Pressure stage bar (PSI) 50 (725)

    Pressure stage bar (PSI) 100 (1450)

    Pressure stage bar (PSI) 200 (2900)

    Pressure stage bar (PSI) 315 (4569) Pressure stage bar (PSI) 350 (5076)

    Min. set pressure at zero command value bar (PSI) See characteristic curve on page 7

    Maximum pressure relief function (infinitely adjustable) Pressure adjustment range: Factory setting:

    Pressure stage bar (PSI) 30 to 70 (435 to 1015) to 70 bar (1015)

    Pressure stage bar (PSI) 50 to 130 (725 to 1886) to 130 bar (1886)

    Pressure stage bar (PSI) 90 to 230 (1305 to 3336) to 230 bar (

    Pressure stage bar (PSI) 150 to 350 (2176 to 5076) to 350 bar (

    Pressure stage bar (PSI) 200 to 390 (2901 to 5657) to 390 bar (

    Max. flow L/min (GPM) 200 (52.83) 400 (105.67)

    Pilot oil flow L/min (GPM)0.5 to 1.8 (0.13 to 0.47) 0.5 to 2.1 (0.13 to 0.55)

    Hydraulic fluid Mineral oil (HL, HLP) to DIN 51524Other hydraulic fluids on enquiry!

    Hydraulic fluid temperature range C (F) 20 to + 80

    Viscosity range mm2/s (SUS) 15 to 380

    Max. permissible degree of contamination of the hydraulic Class 20/18/15 1)

    fluid - cleanliness class to ISO 4406 (c)

    Hysteresis (see command value/pressure characteristic curve) % 1.5 of max. set pressure

    Repeatability % < 2 of max. set pressure

    Linearity % 3.5 of max. set pressure

    Tolerance of the command DBE and DBEM % 2.5 of max. set pressure

    value/pressure curve, DBEE and DBEME % 1.5 of max. set pressurereferred to the hysteresis curve, increasing pressure

    Step response Tu

    + Tg

    0 % 100 % ms 150 depends on flow and on the

    100 % 0 % ms 150 line volume (A) of the system

    1) The cleanliness classes specified for componentsmust be adhered to in hydraulic systems. Effective filtra-tion prevents malfunction and, at the same time, increas-es the service life of components.

    For the selection of filters, see data sheets RE 50070,RE 50076, RE 50081, RE 50086 and RE 50088.

  • 8/8/2019 ra29160_0405

    5/12

    DBE(M) and DBE(M)E | RA 29160/04.05 Industrial Hydraulics | Bosch Rexroth Corp. 5/12

    PE

    1 2

    PE

    1 2

    AF

    EDC

    B

    6.5

    11

    0.2

    5...

    0.4

    3)

    27

    (1.0

    6)

    91 (3.58)

    1

    2

    1

    210A250V

    GDM

    27.5

    (1.08)

    18(0.7

    1)

    43(1.69)

    10 (0.39)

    34.2

    5

    .5

    Technical data (for applications outside these parameters, please consult us!)

    ElectricalSupply voltage V 24 DC

    Min. control current mA 100

    Max. control current DBE and DBEM mA 1600

    DBEE and DBEME mA 1440 to 1760

    Coil resistance Cold value at 20 C 5.4 Max. hot value 7.8

    Duty cycle % 100

    Electrical connection DBE and DBEM With component plug to DIN EN 175301-803

    Cable socket to DIN EN 175301-803 1)

    DBEE and DBEME With component plug to DIN EN 175201-804

    Cable socket to DIN EN 175201-804 1)

    Type of protection of the valve to EN 60529 IP 65 with cable socket mounted and locked

    Control electronics For DBEE and DBEME Integrated in the valve, see page 6

    For DBE and DBEM

    Amplifier in Euro-card format analogue VT-VSPA1-1 according to data sheet RE 30111

    (separate order) digital VT-VSPD-1 according to data sheet RE 30523

    Amplifier of modular design (separate order) analogue VT 11131 according to data sheet RE 29865

    Electrical connection, cable sockets (nominal dimensions in mm)

    For the pin assignment, see block circuit diagram on page 6

    For types DBEE and DBEME with integrated electronics (OBE)

    Cable socket to DIN EN 175201-804Separate order: Material no. R900021267 (version made of plastic )

    For types DBE and DBEM for external control electronics

    Cable socket to DIN EN 175301-803Separate order: Material no. R901017011

    Connection to cable socket

    to amplifier

    Connection to component plug

    1) Separate order, see below

    Note: For details regarding environment simulationtesting in the fields of EMC (electromagnetic

    compatibility), climate and mechanical stress, see RE29160-U (declaration on environmental compatibility).

    1 Fixing screw M3Tightening torque M

    T= 0.5 Nm

  • 8/8/2019 ra29160_0405

    6/12

    6/12 Bosch Rexroth Corp. | Industrial Hydraulics DBE(M) and DBE(M)E | RA 29160/04.05

    R 30 R 43

    ImaxR 13+

    0 V

    +U

    +7,5 V

    -7,5 V

    +

    R 14

    +U

    =

    =

    I

    D

    E

    F

    C

    B

    A

    n.c.

    IminU

    U

    300 Hz

    =

    MP1

    MP2

    n.c.

    1,6 A =

    0,352 V

    2

    2

    22

    24

    26

    28

    30

    20(66)

    40(131)

    60(197)

    80(262)

    100(328)

    0.75 mm

    1 mm

    Integrated electronics for types DBEE and DBEME

    Supply voltage

    Power supply unit with rectifier

    Single phase rectification or three phase bridge: Ueff

    = 22 to 33 V

    Residual ripple content at power supply unit: < 5 %

    Output current: Ieff

    = max. 1.4 A

    Supply cable: Recommended: 5-core 0.75 or 1 mm2with PE conductor and shield

    Outside diameter 6.5 to 11 mm

    Shield to 0 V supply voltage

    Max. permissible length 100 m

    The minimum supply voltage of the power supply unit dependson the length of the supply cable (see diagram).

    For lengths > 50 m a capacitor of 2200 F must be installednear the valve in the supply line.

    0V reference potential

    Block circuit diagram / pin assignment of integrated electronics

    Function

    The integrated electronics is controlled via the two differentialamplifier connections D and E.

    The ramp generator generates from a command value stepchange (0 to 10 V or 10 to 0 V) a delayed rise or drop in thesolenoid current. The rise time can be adjusted by means of

    potentiometer R14, the drop time by means of potentiometerR13.

    The maximum ramp time of 5 s is only possible over the entirecommand value range. With smaller command value changesthe ramp time shortens accordingly.

    The command value/solenoid current characteristic curve ismatched to the valve by the characteristic curve generator,so that non-linearities in the hydraulics can be compensatedfor and hence a linear command value/pressure characteristiccurve is obtained.

    The current regulator controls the solenoid current independ-

    ently of the solenoid coil resistance.

    The gradient of the command value/current characteristiccurve, and hence also the gradient of the command value/pres-sure characteristic curve of the proportional pressure valve may

    be altered using potentiometer R30.Potentiometer R43 is used to adjust the biasing current. Thissetting should not be altered. If necessary, the zero point of thecommand value/pressure characteristic curve can be adjustedat the valve seat.

    The power stage of the electronics for controlling the propor-tional solenoid is a chopper amplifier. It is pulse-width-modu-lated with a clock frequency of 300 Hz.

    The solenoid current can be measured at the two measurementsockets MP1 and MP2. A voltage drop of 0.352 V at the meas-urement resistor corresponds a to solenoid current of 1.6 A.

    Command value 0 to 10 V

    Supply

    voltage:U

    eff: 22 to 33 V

    Chopper

    amplifier

    Ramp

    "up"

    Ramp

    "down"

    Internal reference point

    Measuring resis-

    tor R=0.22

    Oscillator

    Solenoid

    Power supply unit

    Ramp

    generator

    Differential

    amplifier

    Char. curve

    generatorCurrent

    regulator

    0 V

    Length of supply cable in m

    Min.supplyvoltageinV

  • 8/8/2019 ra29160_0405

    7/12

    DBE(M) and DBE(M)E | RA 29160/04.05 Industrial Hydraulics | Bosch Rexroth Corp. 7/12

    0

    2 (29)

    6 (87)

    8 (116)

    10 (145)

    4 (58)

    100 200 300

    0 25 50 75 100

    15 (218)

    20 (290)

    30 (435)

    35 (508)

    40 (580)

    45 (653)

    50 (725)

    25 (363)

    10 (145)

    5 (73)

    0 25 50 75 100

    30 (435)40 (580)

    60 (870)70 (1015)

    80 (1160)90 (1305)

    100 (1450)

    50 (725)

    20 (290)10 (145)

    0 25 50 75 100

    60 (870)80 (1160)

    120 (1740)140 (2031)

    160 (2321)180 (2611)

    200 (2901)

    100 (1450)

    40 (580)20 (290)

    315 (4569)

    0 25 50 75 100

    150 (2176)

    250 (3626)

    300 (4351)

    200 (2901)

    100 (1450)

    50 (725)

    0 25 50 75 100

    150 (2176)

    250 (3626)

    300 (4351)

    200 (2901)

    100 (1450)

    50 (725)

    350 (5075)

    0 100(26.42)

    200(52.83)

    300(79.25)

    400(105.67)

    50 (725)

    100 (1450)

    200 (2901)

    250 (3626)

    300 (4351)

    350 (5075)

    400 (5802)

    150 (2176)

    Command value/pressure characteristic curves(measured at a flow of 27 L/min)

    Pressure stage 315 bar

    Characteristic curves - measured with HLP-46, oil

    = 40C 5C (104F 41F)

    Set pressure in dependence upon the flow

    Min.setpressureinbar(PSI)

    Flow in L/min (GPM)

    Pressure stage 100 barPressure stage 200 bar

    Pressure stage 50 bar

    Pressure stage 350 bar

    Pressureinbar(PSI)

    Command value in %

    The characteristic curves are valid for an outlet pressure in

    B = 0 bar over the entire flow range.Note: In order that the min. set pressure can be achieved,

    the biasing current must not exceed 100 mA.

    Min.setpressureinbar(PSI)

    Flow in L/min (GPM)

    Min. set pressure at command value 0

    Size 10 Size 25

    Pressureinbar(PSI)

    Command value in %

    Pressureinbar(PSI)

    Command value in %

    Command value in % Command value in %

    Size 10Size 10

    Size 25Size 25

    Pressureinbar(PSI)

    Pressureinbar(PSI)

  • 8/8/2019 ra29160_0405

    8/12

    8/12 Bosch Rexroth Corp. | Industrial Hydraulics DBE(M) and DBE(M)E | RA 29160/04.05

    8 3

    89 (3.50)

    17.3(

    0.6

    8)

    78(

    3.0

    7)

    53.8 (2.12)

    53.8(

    2.1

    2)

    104(

    4.0

    9)

    27 (1.06)

    14 (0.55)

    25 (0.98)G 1/4

    145(

    5.7

    1)

    15

    (0.5

    9)

    Y

    A B

    Y

    15 (0.59)

    196 (7.72)

    B

    21 (0.83)

    26

    (3.0

    7)

    A

    12.3

    (0.48)

    129(

    5.0

    8)

    47.5 (1.87)

    22.5(0.86)

    78(

    3.0

    7)

    22.1 (0.87)

    5(

    0.2

    0)

    X

    X

    263 (10.35) with integrated electronics

    45(1.7

    7)

    26.4 (1.04)

    17.5 (0.69)

    21.8 (0.86)

    14 (0.55)6(0.24)

    4 6 7 9

    2

    5

    1

    10

    0,01/100mm

    Rzmax4

    Unit dimensions: Size 10 - nominal dimensions in mm (inches)

    Subplates to data sheet RE 45064 and valve fixing screws must

    be ordered separately.Subplates: G 545/01, G 3/8 (SAE-6; 9/16-18)

    G 546/01, G 1/2 (SAE-8; 3/4-16)Valve fixing screws:

    4 socket head cap screws M12 x 50 DIN 912-10.9

    (1/2-13 UNC x 2)

    Tightening torque MT

    = 70 Nm (51.63 lb-ft)

    Required

    surface quality of the

    mating part

    1 Different seal rings for ports A and B

    2 Seal ring for port X

    3 Space required to remove cable socket

    4 Nameplate

    5 Locating pin

    6 Maximum pressure relief function (types DBEM, DBEME)When using these valves, observe the notes on page 4!

    7 External pilot oil drain,separate and at zero pressure to tank

    8 Cable socket for type DBE(M)(separate order, see page 5).

    9 Integrated electronics (OBE)

    10 Cable socket for type DBE(M)E(separate order, see page 5).

    Tolerances to: General tolerances ISO 2768-mK

    Tolerancing principle ISO 8015

  • 8/8/2019 ra29160_0405

    9/12

    DBE(M) and DBE(M)E | RA 29160/04.05 Industrial Hydraulics | Bosch Rexroth Corp. 9/12

    117 (4.61)

    79(

    3.1

    1)

    66.7 (2.63)

    70(

    2.7

    6)

    18 (0.71)23.8 (0.94)

    26 (1.02)

    105(

    4.1

    3)

    33 (1.30)

    130(

    5.1

    2)

    11.1 (0.44)34.5

    (1.36) 55.6 (2.19)

    33.4 (1.31)

    100(

    3.9

    4)

    G 1/ 4

    146(

    5.7

    5)

    195 (7.68)

    A

    40.7 (1.60) 40.7 (1.60)

    17.5 (0.69) 25 (0.98)

    B

    Y

    YA B

    X

    262 (10.31) with integrated electronics

    X

    4 6 7 9 8

    2

    1

    5

    10

    1

    17.3(

    0.6

    8)

    25 (0.98)

    15

    (0.5

    9)

    15 (0.59)

    26

    (3.0

    7) 12.3

    (0.48)

    5(

    0.2

    0)

    45(1.7

    7)

    6

    (0.24)

    0,01/100mm

    Rzmax4

    Unit dimensions: Size 25 - nominal dimensions in mm (inches)

    Subplates to data sheet RE 45064 and valve fixing screws mustbe ordered separately.Subplates: G 408/01, G 3/4 (SAE-12; 1-1/16-12)

    G 409/01, G 1 (SAE-16; 1-5/16-20)

    Valve fixing screws:

    4 socket head cap screws M16 x 50 DIN 912-10.9

    (5/8-11 UNC x 2)

    Tightening torque MT

    = 150 Nm (110.63 lb-ft)

    Required

    surface quality of themating part

    1 Identical seal rings for ports A and B

    2 Seal ring for port X3 Space required to remove cable socket

    4 Nameplate

    5 Locating pin

    6 Maximum pressure relief function (types DBEM, DBEME)

    When using these valves, observe the notes on page 4!

    7 External pilot oil drain, separate and at zero pressure to tank

    8 Cable socket for type DBE(M

    (separate order, see page 5)

    9 Integrated control electronics

    10 Cable socket for type DBE(M)E

    (separate order, see page 5)

    Tolerances to: General tolerances ISO 2768-mK

    Tolerancing principle ISO 8015

  • 8/8/2019 ra29160_0405

    10/12

    10/12 Bosch Rexroth Corp. | Industrial Hydraulics DBE(M) and DBE(M)E | RA 29160/04.05

    Notes

    Bosch Rexroth Corp.Industrial Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

    2004 Bosch Rexroth CorporationAll rights reserved. Neither this document nor any part of it may be reproduced,

    duplicated circulated or disseminated, whether by copy, electronic format orany other means, without the prior consent and authorization of Bosch RexrothCorporation.

    The data and illustrations in this brochure/data sheet are intended only todescribe or depict the products. No representation or warranty, either expressor implied, relating to merchantability or fitness for intended use, is given or

    intended by virtue of the information contained in this brochure/data sheet. Theinformation contained in this brochure/data sheet in no way relieves the user of itobligation to insure the proper use of the products for a specific use or applica-

    tion. All products contained in this brochure/data sheet are subject to normalwear and tear from usage.

    Subject to change.

  • 8/8/2019 ra29160_0405

    11/12

    Bosch Rexroth Corp. | Industrial Hydraulics (Z)DBE and (Z)DBEE | RA 29158/04.05

    Bosch Rexroth Corp.Industrial Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

    2004 Bosch Rexroth CorporationAll rights reserved. Neither this document nor any part of it may be reproduced,duplicated circulated or disseminated, whether by copy, electronic format or

    any other means, without the prior consent and authorization of Bosch RexrothCorporation.

    The data and illustrations in this brochure/data sheet are intended only to

    describe or depict the products. No representation or warranty, either expressor implied, relating to merchantability or fitness for intended use, is given orintended by virtue of the information contained in this brochure/data sheet. The

    information contained in this brochure/data sheet in no way relieves the user of itobligation to insure the proper use of the products for a specific use or applica-tion. All products contained in this brochure/data sheet are subject to normal

    wear and tear from usage.

    Subject to change.

    Notes

  • 8/8/2019 ra29160_0405

    12/12

    Bosch Rexroth Corp. | Industrial Hydraulics (Z)DBE and (Z)DBEE | RA 29158/04.05

    Bosch Rexroth Corp.Industrial Hydraulics2315 City Line RoadBethlehem, PA 18017-2131USATelephone (610) 694-8300Facsimile (610) 694-8467www.boschrexroth-us.com

    2004 Bosch Rexroth CorporationAll rights reserved. Neither this document nor any part of it may be reproduced,duplicated circulated or disseminated, whether by copy, electronic format or

    any other means, without the prior consent and authorization of Bosch RexrothCorporation.

    The data and illustrations in this brochure/data sheet are intended only to

    describe or depict the products. No representation or warranty, either expressor implied, relating to merchantability or fitness for intended use, is given orintended by virtue of the information contained in this brochure/data sheet. The

    information contained in this brochure/data sheet in no way relieves the user of itobligation to insure the proper use of the products for a specific use or applica-tion. All products contained in this brochure/data sheet are subject to normal

    wear and tear from usage.

    Subject to change.

    Notes