r22t6 r22t8 1.0 q - GIGABYTE
Transcript of r22t6 r22t8 1.0 q - GIGABYTE
![Page 1: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/1.jpg)
Service Guide
GIGABYTEGS-R22T61-RH/GS-R22T81-RH
2U Rack Mount Server
Dual Intel® Xeon LGA1366 Processor Serverboard
Rev. 1.0
![Page 2: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/2.jpg)
PrefaceBefore using this information and the product it supports, please read the following general information.
1. This Service Guide provides you with all technical information relating to the BASIC
CONFIGURATION decided for GIGABYTE's “global” product offering. To better fit local market
requirements and enhance product competitiveness, your regional office MAY have decided to
extend the functionality of a machine (e.g. add-on card, modem, or extra memory capability).
These LOCALIZED FEATURES will NOT be covered in this generic service guide. In such
cases, please contact your regional offices or the responsible personnel/channel to
provide you with further technical details.
2. Please note WHEN ORDERING FRU PARTS, you should check the most up-to-date information
available on your regional web or channel. For whatever reason, if a part number change is made,
it will not be noted in the printed Service Guide. For GIGABYTE-AUTHORIZED SERVICE
PROVIDERS, your GIGABYTE office may have a DIFFERENT part number code to those
given in the FRU list of this printed Service Guide. You MUST use the list provided by your
regional GIGABYTE office to order FRU parts for repair and service of customer machines.
![Page 3: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/3.jpg)
3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Table of Contents
Preface .................................................................................................... 2
Safety, Care and Regulatory Information ................................................ 5
System Specification .............................................................................. 9
System Hardware Installation ................................................................ 11Chassis Removal and Installation ................................................................................. 12
CPU Installation ............................................................................................................... 13
Heat Sink Installation ....................................................................................................... 14
Memory Installation ......................................................................................................... 15
PCI Expansion Card Installation (GC-RLE2N-RH/GC-RFE2N-RH) .......................... 18
PCI Expansion Card Installation (GC-RFX2N-RH/Optional) ....................................... 20
GS-R22T81-RH Hard Disk Drive Installation ................................................................ 22
GS-R22T61-RH Hard Disk Drive Installation ................................................................ 23
FAN Duct Removal and Installation .............................................................................. 24
Appearance of GS-R22T61-RH/GS-R22T81-RH ................................... 25Front View of GS-R22T61-RH (For 3.5 HDDs solution) .............................................. 25
Front View of GS-R22T81-RH (For 2.5 HDDs solution) .............................................. 25
Rear View of GS-R22T61-RH/GS-R22T81-RH ........................................................... 26
Front Panel LED Indicators ............................................................................................. 27
LAN port LED Indicator .................................................................................................... 28
Hard Disk Drive LED Description ................................................................................... 29
GC-BS28E-RH Back plane board Components Description ....................................... 30
(for 2.5”HDD) .................................................................................................................... 30
GC-BS26E-RH Back plane board Components Description ....................................... 32
(for 3.5”HDD) .................................................................................................................... 32
System Block Diagram ................................................................................................... 34
GS-R22T61-RH Cable Routing ...................................................................................... 35
.......................................................................................................................................... 35
GS-R22T81-RH Cable Routing ...................................................................................... 36
Connector Icon Description ............................................................................................. 37
Motherboard Placement and Jumper Setting ...................................... 38GA-7TTSH-RH Motherboard Component ...................................................................... 38
Motherboard Jumper Setting ........................................................................................... 41
Expansion Card Components Description .................................................................... 43
![Page 4: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/4.jpg)
4
Table of Content
BIOS Setup ........................................................................................... 46Main ........................................................................................................... 48
Advanced ................................................................................................... 50Processor Configuration .................................................................................................. 51
Processor Power Management ..................................................................................... 55
Memory Configuration ..................................................................................................... 58
Advanced Chipset Configuration ................................................................................... 60
PCI Configuration ............................................................................................................. 64
SATA Configuration .......................................................................................................... 66
I/O DeviceConfiguration .................................................................................................. 69
Boot Configuration ............................................................................................................ 71
Thermal and Acoustic Configuration .............................................................................. 73
Power ......................................................................................................... 75
Security ...................................................................................................... 77
Server ......................................................................................................... 79System Management ...................................................................................................... 80
Console Redirection ........................................................................................................ 82
Event Log Configuration .................................................................................................. 84
Boot ............................................................................................................ 85
Exit ............................................................................................................. 86
Appexdix A Phoenix BIOS Beep Codes ............................................. 92
Appexdix B PhoenixBIOS POST Error Messages List ...................... 96
![Page 5: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/5.jpg)
5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Safety, Care and Regulatory Information Important safety information
Read and follow all instructions marked on the product and in the documentation before you operate
your system. Retain all safety and operating instructions for future use.
* The product should be operated only from the type of power source indicated on the rating label.
* If your computer has a voltage selector switch, make sure that the switch is in the proper position for
your area. The voltage selector switch is set at the factory to the correct voltage.
* The plug-socket combination must be accessible at all times because it serves as the main disconnect-
ing device.
* All product shipped with a three-wire electrical grounding-type plug only fits into a grounding-type power
outlet. This is a safety feature. The equipment grounding should be in accordance with local and national
electrical codes. The equipment operates safely when it is used in accordance with its marked electrical
ratings and product usage instructions
* Do not use this product near water or a heat source.
* Set up the product on a stable work surface or so as to ensure stability of the system.
* Openings in the case are provided for ventilation. Do not block or cover these openings. Make sure you
provide adequate space around the system for ventilation when you set up your work area. Never insert
objects of any kind into the ventilation openings.
* To avoid electrical shock, always unplug all power cables and modem cables from the wall outlets
before removing covers.
* Allow the product to cool before removing covers or touching internal components.
Precaution for Product with Laser DevicesObserve the following precautions for laser devices:
* Do not open the CD-ROM drive, make adjustments, or perform procedures on a laser device other
than those specified in the product's documentation.
* Only authorized service technicians should repair laser devices.
Precaution for Product with Modems, Telecommunications, ot Local Area
Network OptionsObserve the following guidelines when working with options:
* Do not connect or use a modem or telephone during a lightning storm. There may be a risk of electrical
shock from lightning.
![Page 6: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/6.jpg)
6
Safety Information* To reduce the risk of fire, use only No. 26 AWG or larger telecommunications line cord.
* Do not plug a modem or telephone cable into the network interface controller (NIC) receptacle.
* Disconnect the modem cable before opening a product enclosure, touching or installing internal
components, or touching an uninsulated modem cable or jack.
* Do not use a telephone line to report a gas leak while you are in the vicinity of the leak.
Federal Communications Commission (FCC) StatementWarning
This is a class A product. In a domestic environment this product may cause radio
interference
In which case the user may be required to take adequate measures.
Note: This equipment has been tested and found to comply with the limits for a Class A digital device,
pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with
the instruction manual, may cause harmful interference to radio communications. Operation of this
equipment in a residential area is likely to cause harmful interference in which case the user will be
required to correct the interference at his own expense.
Properly shielded and grounded cables and connectors must be used in order to meet FCC emission
limits. Neither the provider nor the manufacturer are responsible for any radio or television interference
caused by using other than recommended cables and connectors or by unauthorized changes or
modifications to this equipment. Unauthorized changes or modifications could void the user's authority to
operate the equipment.
This device complies with Part 15 of the FCC Rules. Operation is subject to the following two conditions:
(1) this device may not cause harmful interference, and
(2) this device must accept any interference received, including interference that may cause undesired
operation.
FCC part 68 (applicable to products fitted with USA modems)The modem complies with Part 68 of the FCC Rules. On this equipment is a label that contains, among
other information, the FCC registration number and Ringer Equivalence Number (REN) for this equipment.
You must, upon request, provide this information to your telephone company.
If your telephone equipment causes harm to the telephone network, the Telephone Company may
discontinue your service temporarily. If possible, they will notify in advance. But, if advance notice is not
practical, you will be notified as soon as possible. You will be informed of your right to file a complaint with
![Page 7: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/7.jpg)
7
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
the FCC.
Your telephone company may make changes in its facilities, equipment, operations, or procedures that
could affect proper operation of your equipment. If they do, you will be notified in advance to give you an
opportunity to maintain uninterrupted telephone service.
The FCC prohibits this equipment to be connected to party lines or coin-telephone service.
The FCC also requires the transmitter of a FAX transmission be properly identified (per FCC Rules Part
68, Sec. 68.381 (c) (3)).
/ for Canadian users only /
Canadian Department of Communications Compliance Statement
This digital apparatus does not exceed the Class B limits for radio noise emissions from digital
apparatus as set out in the radio interference regulations of Industry Canada.
Le present appareil numerique n'emet pas de bruits radioelectriques depassant les limites applicables aux
appareils numeriques de Classe A prescrites dans le reglement sur le brouillage radioelectrique edicte par
Industrie Canada.
DOC notice (for products fitted with an Industry Canada-compliant modem)
The Canadian Department of Communications label identifies certified equipment. This certification
means that the equipment meets certain telecommunications network protective, operational and safety
requirements. The Department does not guarantee the equipment will operate to the user satisfaction.
Before installing this equipment, users ensure that it is permissible to be connected to the facilities of the
local Telecommunications Company. The equipment must also be installed using an acceptable method
of connection. The customer should be aware that compliance with the above conditions might not prevent
degradation of service in some situations.
Repairs to certified equipment should be made by an authorized Canadian maintenance facility designated
by the supplier. Any repairs or alterations made by the user to this equipment, or equipment malfunctions,
may give the telecommunications company cause to request the user to disconnect the equipment.
Users should ensure for their own protection that the electrical ground connections of the power utility,
telephone lines and internal metallic water pipe system, if resent are connected together. This precaution
may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the
appropriate electric inspection authority, or electrician, as appropriate.
![Page 8: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/8.jpg)
8
Safety Information
NOTICE: The Load Number (LN) assigned to each terminal device denotes the percentage of the total
load to be connected to a telephone loop which is used by the device, to prevent overloading. The
termination on a loop may consist of any combination of devices subject only to the requirement that the
sum of the Load Numbers of all the devices does not exceed 100.
/ for European users only /
Class A equipmentThis device has been tested and found to comply with the limits for a class A digital device pursuant
Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against
harmful interference when the equipment is operated in a commercial environment. This equipment
generate, uses, and can radiate radio frequency energy, and if not installed and used in accordance
with the instructions, may cause harmful interference to radio communication. Operation of this
equipment in a residential area is likely to cause harmful interference, in which case the user will be
required to correct the interference at personal expence.
However, there is no guarantee that interference will not occur in a particular installation. If this
device does cause harmful interference to radio or television reception, which can be determined by
tuning the device off and on, the user is encouraged to try to correct the interference by on or more of
the following measures:
Reorient or relocate the receiving antenna
Increase the separation between the device and receiver
Connect the device into an outlet on a circuit different from that to which the receiver is
connected
Consult the dealer or an experienced radio/television technician for help
CAUTION Danger of explosion if battery is incorrectly
replaced.
Replace only with the same or equivalent
type recommended by the manufacturer.
Dispose of used batteries according to the
manufacturer’s instructions.
![Page 9: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/9.jpg)
9
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Motherboard GA-7TTSH1-RH
Processor Supported Supports dual Intel® Xeon® processors
Intel Xeon® Dual-Core/Quad-Core processor in LGA 1366 socket
Supports Intel Quickpath Interconnect up to 6.4 GT/s
Chipset Northbridge: Intel® 5520 Chipset
Southbridge: Intel® ICH10R
System Memory:
Memory Capacity 12 x DDR 3 sockets up to 48GB/96GB (1 to 4 GB unbuffered
DIMMs for up to 48GB or 1 to 8 GB registered DIMM for up to
96GB of total system memory)
Memory Type DDR 3 133 MHz ECC registered/unbuffered DIMMs
DIMM Size 512MB, 1GB, 2GB, 4GB, and 8GB capability modules support
Error Correction: Single-bit Errors Correction, Multiple Bit Errors Detection
Riser Slot
Full height riser card: (Top) One PCI-E x8 slot (PCI-E x 8 throughput) , Gen2.
(Black color connector)
(Middle)One PCI-E x8 slot (PCI-E x 8 throughput) , Gen2.
(Black color connector)
(Bottom). (Black color connector) PCI-E x8 (PCI-E x8 throughput),
Gen2.
Full height riser card: (Optional) (Top) One PCI-X 64/133MHz (White color connector)
(Middle)One PCI-E x8 slot (PCI-E x 8 throughput) , Gen2.
(Black color connector)
(Bottom)One PCI-E x8 slot (PCI-E x 8 throughput) , Gen2.
(Black color connector)
Low-profile riser card: (Top)One PCI-E x8 slot (PCI-E x 8 throughput), Gen2.
(Black color connector)
(Middle)One PCI-E x8 slot (PCI-E x4 throughput), Gen1.
(White color connector)
SATA RAID controller Intel® ICH10R
Supports LSI Software RAID 0/1/10
Cooling Fans: 6 X System Fan
System Specification
![Page 10: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/10.jpg)
1 0
Feature SummaryIntegrated LANs:
Controller Intel® 82576EB controller support dual GbE ports
Integrated Graphics:
Controller Integrated in Server Engines Pilot II
Graphics Memory 32MB DDR2
Mass Storage System 6 x 3.5” Hot-Swap SATA /SAS HDDs
Or, 16 x 2.5” Hot-Swap SATA /SAS HDDs
1 x DVD Combo
Super I/O
Controller ITE IT8720 Super I/O
Front I/O 1 x VGA port
2 x USB 2.0 dual-port connector
Rear I/O P/S 2 Keyboard and Mouse Connectors
1 x Serial port
4 x USB 2.0 ports
1 x VGA connector
2 x GLAN ports
1 x 10/100 LAN port
System BIOS:
BIOS Type Phoenix BIOS on 8Mb flash ROM
Server Management Functions: (Optional device)
BMC Chip Server Engines POLIT 2 IPMI 2.0 controller
Failure Detection IPMI 2.0 specification of Server management
Event Logging 32KB Nonvolatile Memory to Log System Failure Events
Remote Management Follow the IPMI 2.0 specification of Server management
Environment
Ambient Temperature Operating Temperature: 5oC to 35oC
Non-operating Temperature: 0oC to 50oC
Relative Humidity 10-80% operating Humidity at 30o C
System Dimention: 432mm x 210mm x 650mm
Electrical Power Supply Redundant Power Supply 750W
![Page 11: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/11.jpg)
1 1
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Pre-installation Instructions
Perform the steps below before you open the server or before you remove or replace
any component.
1. Back up all important system and data files before performing any hardware
configuration.
2. Turn off the system and all the peripherals connected to it.
3. Unplug all cables from the power outlets.
4. Disconnect all telecommunication cables from their ports.
5. Place the system unit on a flat and stable surface.
6. Open the system according to the instructions.
Warning! Failure to properly turn off the server before you start installing components
may cause serious
damage. Do not attempt the procedures described in the following sections unless you
are a qualified service
technician.
System Hardware Installation
![Page 12: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/12.jpg)
1 2
Hardware Installation Process
Chassis Removal and InstallationStep 1 Remove the screw on the chassis.
Step 2 Slide toward the top chassis cover.
Step 3 Lift up to remove the top chassis cover.
Step 4 Reverse Step 1, ,2, 3 to replace the chassis cover
1
3
2
![Page 13: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/13.jpg)
1 3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
1
23
CPU InstallationPlease make sure the CPU type and speed that are supported by the motherboard.
Step 1 Raise the metal locking lever on the socket. Insert the CPU with the correct orientation.
Step 2 The CPU only fits in one orientation.
Step 3 Push the metal lever back into locked position.
![Page 14: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/14.jpg)
1 4
Hardware Installation Process
Heat Sink InstallationStep 1 Place the Heat Sink on the CPU. Before putting the heat sink on the CPU, please well
remember to apply the thermal conductivity compound on the CPU.
Step 2 Seat the heat sink in the retention modules with the four screws. Installation completed.
1
1
1
1
1
2
2
2
2
2
2
2
![Page 15: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/15.jpg)
1 5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Memory Installation
1
2
2
CPU1
CPU2
DIMMA2DIMMA1
DIMMB2DIMMB1
DIMMC2DIMMC1
DIMMD2DIMMD1
DIMME2DIMME1 DIMMF2
DIMMF1
Step 1. Insert the DIMM memory module vertically into the DIMM slot, and push it down.
Step 2. Close the plastic clip at both edges of the DIMM slots to lock the DIMM module.
NOTE! DIMM must be populated in order starting from DIMMA1/D1 sockets. For dualquad
channel operation, DIMMs must be installed in matched pairs.
Step 3. Reverse the installation steps when you wish to remove the DIMM module.
![Page 16: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/16.jpg)
1 6
Hardware Installation Process
U-DIMM Population Table
DIMMA1/D1
1GB
Interleavemode
SingleChannel
DualChannel
ThreeChannel
DIMMA2/D2 DIMMB1/E1 DIMMB2/E2 DIMMC1/F1 DIMMC2/F2
Channel A Channel B Channel CTotal Memory
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
2GB
4GB
8GB
8GB
4GB1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
1GB
2GB
4GB
6GB
12GB
16GB
6GB
3GB
16GB
24GB
![Page 17: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/17.jpg)
1 7
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
R-DIMM Population Table
Interleavemode
SingleChannel
DualChannel
ThreeChannel
Channel A Channel B Channel CTotal Memory
DIMMA1/D1
1GB
DIMMA2/D2 DIMMB1/E1 DIMMB2/E2 DIMMC1/F1 DIMMC2/F2
2GB
4GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB 1GB
2GB
4GB
8GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
1GB
2GB
4GB
8GB
6GB
12GB
24GB
48GB
8GB
2GB
4GB
8GB
16GB
4GB
8GB
16GB
32GB
3GB
6GB
12GB
24GB
![Page 18: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/18.jpg)
1 8
Hardware Installation Process
PCI Expansion Card Installation (GC-RLE2N-RH/GC-RFE2N-RH)Step 1 Loosen the riser bracket screws which attached on on the system.
Step 2 Loosen the rest riser bracket bracket screws.
Step 3 Lift the riser bracket slightly, then pull it out from the server chassis.
Step 4 Slide the expansion card into the slot until the card firmly seats.
Step 5 Slide another expansion card into the slot until the card firmly seats.
Align the riser bracket to the system module.
3
2
11
2
2
![Page 19: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/19.jpg)
1 9
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
4
5
![Page 20: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/20.jpg)
2 0
Hardware Installation Process
PCI Expansion Card Installation (GC-RFX2N-RH/Optional)Step 1 Loosen the riser bracket screws which attached on on the system.
Step 2 Loosen the rest riser bracket bracket screws.
Step 3 Lift the riser bracket slightly, then pull it out from the server chassis.
Step 4 Attach the PCI-E card to the riser bracket.
Step 5 Secure the card with screws.
Step 6 Attach anothr PCI-E card to the riser bracket the other side.
Step 7 Secure the card with screws.
Step 8 Align the riser bracket to the system module until it firmly seats.
3
2
11
2
2
![Page 21: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/21.jpg)
2 1
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
4
5
5
6
7
77
![Page 22: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/22.jpg)
2 2
Hardware Installation Process
GS-R22T81-RH Hard Disk Drive InstallationStep 1 Press the release button.
Step 2 Pull the blank out of the drive bay.
Step 3 Place hard disk into blank.
Step 4 Secure it with screws.
Slide the blank into the bay until it locks into place. Connect cable and power.
1
3
2
4
4
![Page 23: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/23.jpg)
2 3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
GS-R22T61-RH Hard Disk Drive InstallationStep 1 Press the release button.
Step 2 Pull the blank out of the drive bay.
Step 3 Place hard disk into blank.
Step 4 Secure it with screws.
Slide the blank into the bay until it locks into place. Connect cable and power.
3
2
4
4
1
![Page 24: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/24.jpg)
2 4
Hardware Installation Process
FAN Duct Removal and InstallationStep 1 Lift the fan duct from the chassis.
Step 2 To install fan duct, align the fan duct with the guiding groove. Push down the fan duct into system
until its firmly seats.
1
![Page 25: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/25.jpg)
2 5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
210 3 4 5 6 7 8 9 1011 121314 15
Front View of GS-R22T61-RH (For 3.5 HDDs solution)Appearance of GS-R22T61-RH/GS-R22T81-RH
2
1
0 3
4
5
NOTE! For Front LED description, please go to Switch and LED Indicators
Introduction section.
Number indicates the HDD installation order.
Front View of GS-R22T81-RH (For 2.5 HDDs solution)
Front panel LEDs and Power Button
USB connectors
VGA port
3.5” Hot-Swap SATA/SAS HDDs
Front panel LEDs and Power Button
USB connectors
VGA port
2.5” Hot-Swap SATA/SAS HDDs
![Page 26: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/26.jpg)
System Appearance
2 6
Rear View of GS-R22T61-RH/GS-R22T81-RH
Power
Keyboard connector
G-LAN ports
COM port
VGA port
10/100 LAN port
USB connectors
ID switch
Low-profile riser slots
Full-height riser slots
Mouse connector
![Page 27: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/27.jpg)
2 7
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Front Panel LED Indicators
No Indicator
1 LAN1
activity
2 LAN2
activity
3 HDD
activity
4 System
status
5 System ID
Color State Description
Green On Link between system and
network or no access
Green Blink Network access
Green On Link between system and
network or no access
Green Blink Network access
Green Blink HDD access
N/A Off No access
Green On Running or normal operation
Amber On Critical or non-recoverable
condition (Power module or
voltage power supply failure
or critical temperature)
Amber Blink Non-critical condition
N/A Off System not ready
May indicate the following:
POST error
NMI event
Processor or terminator
missing
Blue On System identification is active
Off System identification is disabled
![Page 28: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/28.jpg)
2 8
LED Description
No Indicator
6 Power
status
Color State Description
Green On System has power supplyto it or
ACPI S0 state
Green Blink System is in ACPI S1 state
(sleep mode)
N/A Off System is not powered on or in
ACPI S5 state (power off)
System is in ACPI S4 state
(hlbernate mode)
LAN port LED Indicator
No Name
1 Speed
indicator
2 Link/activity
indicator
Color State Description
N/A Off 10Mbps connection
Green On 100Mbps connection
Yellow On 1000Mbps connection
Note: The server management port does
not support 1000Mbps connection
Green On Active connection
Green Blink Transmit or receive connection
![Page 29: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/29.jpg)
2 9
LED Description
Hard Disk Drive LED Description
Description
HDD Prsent
HDD access
HDD failure
HDD removed
HDD connected and
rebuilding data
HDD locate
SAS/SATA HDD indicator
Green Red
On Off
Blink (4Hz) Off
Off On
Off On
On Blink (1 Hz)
Blink (4Hz) Blink (4Hz)
![Page 30: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/30.jpg)
3 0
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
GC-BS28E-RH Back plane board Components Description
(for 2.5”HDD)
No Code Description
1 SAS/CON1 SAS 8484 32-pin connector (port 0 ~ 3)
2 SAS/CON2 SAS 8484 32-pin connector (port 4 ~ 7)
3 CN2/X1 Power connector (4-pin)
4 CN1/X1 Power connector (4-pin)
5 J3 SMBUS connector for backplane cascade
6 J1 SMBUS connector to RAID card
7 J2 SMBUS connector to main board (J2)
8 J27 Close 1-2: Two LED indication (default)
Close 2-3: Single LED indication (backward support)
9 J21 LED Power Select
10 SF6 System fan connector for system fan #6
11 SF5 System fan connector for system fan #5
12 SF4 System fan connector for system fan #4
13 SF3 System fan connector for system fan #3
14 SF2 System fan connector for system fan #2
15 SF1 System fan connector for system fan #1
16 SGPIO_JP2 SGPIO Connector
17 SGPIO_JP1 SGPIO Connector
1234
56
7
8
9
19
20
21
10 12 13
18
11 14 15
22
17
16
![Page 31: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/31.jpg)
3 1
Back Plane Board Description
GC-BS28E-RH Back plane board Components Description Condt’
J28 J29 J30 J31
B/P_1 Close 2-3 Close 1-2 Close 2-3 Close 2-3
B/P_2 Close 1-2 Close 2-3 Close 1-2 Close 1-2
No Code Description
18 J28 Back plane board adress setting
19 J29 Back plane board adress setting
20 J30 Back plane board adress setting
21 J31 Back plane board adress setting
22 J12 Debug port
1234
56
7
8
9
19
20
21
10 12 13
18
11 14 15
22
17
16
![Page 32: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/32.jpg)
3 2
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
GC-BS26E-RH Back plane board Components Description
(for 3.5”HDD)
4
1
2 5
7
6
8
9
101112131415
16
18 17
20 19 21 22
2324
25
26
3
No Code Description
1 J1 SMBUS connector from RAID card
2 J2 SMBUS connector from Enclosure IC(Motherboard)
3 J3 SMBUS connector from RAID card
4 SGPIO_J1 SGPIO Connector
5 SGPIO_J2 SGPIO Connector
6 SAS/CON1 SAS 8484 32pin Connector
7 SAS/CON2 SAS 8484 32pin Connector
8 CN1/X1 1x4 Pin Power Connector
9 CN1/X2 1x4 Pin Power Connector
10 FAN1 System fan connector
11 FAN2 System fan connector
12 FAN3 System fan connector
13 FAN4 System fan connector
14 FAN5 System fan connector
15 FAN6 System fan connector
16 J12 Debug Port
17 J13 LED Power charge selection
1-2 Close: No changes
18 J14 For dependent on HDD Tray’s LED conduct to setting
Close 1-2: Two LED
Close 2-3: Single LED
![Page 33: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/33.jpg)
3 3
Back Plane Board Description
GC-BS26E-RH Back plane board Components Description Condt’
No Code Description
19 J15 Hardware Address setting
20 J16 Hardware Address setting
21 J17 Hardware Address setting
22 J18 Hardware Address setting
23 J7 LED controller configuration jumper
24 J9 LED controller configuration jumper
25 J10 LED controller configuration jumper
26 J11 LED controller configuration jumper
4
1
2 5
7
6
8
9
101112131415
16
18 17
20 19 21 22
2324
25
26
3
![Page 34: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/34.jpg)
3 4
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
System Block Diagram
VRD 11.1VRD 11.1
CPU2
Nehalem-EP
Processor
LGA1366
Port 1
CPU1
Nehalem-EP
Processor
LGA1366
Port 1Q
PI QPI
INTEL ICH10R
CLI
NK
ESI
DD
R3
DD
R3
DD
R3
DD
R3
DD
R3
DD
R3
DD
R3
DD
R3
DD
R3
DD
R3
DD
R3
DD
R3
SPD2
QPI
INTEL
Tylersburg-36D
IOH
Kawela
PCIE
x4RMI
PILOT II
LPCUSB x 1 *2 (USB0/1)
PCIE x1
ID
Switch
SwitchFP_VGA Connect
LAN port x2
COM_C
Rear VGA
BCM5221
KVM
LAN
RM
IIITE8720
TPM
Connector
PS/2USBX1 *4
USB (Type A)USBX1 *1
USBX1 (Support SSD)USBX1 *1
USBX1 *2Front USB1
Front USB2USBX1 *2
SLOT3 (x8+x8)
USB port
x 4
SATA0 SATA1 SATA2 SATA3 SATA4 SATA5
SATAII
SLOT2 (x8)
PCIEX8_RR
SLOT1 (x4+x8)
PCIEX8_RU
PCIEX8_RD
PCIE x8 GEN2
PCIE x8 GEN2
PCIE x8 GEN2
PCIE x4 GEN1
SPD1
![Page 35: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/35.jpg)
3 5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
GS-R22T61-RH Cable Routing
No Suggest Cable
1 D-Sub cable
2 SAS to SATA * cable (B/P to onboard
SATA) with SGPIO
3 Power cable for CPU
4 Fan Kit cables
No Suggest Cable
5 VGA cable
6 Front I/O + USB cables
7 SMBus cable
8 Power cable
9 Case open instrusion cable
1
2
2
3
34 4
4
4
44
4
5
5
6
6
67
78
9
9
![Page 36: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/36.jpg)
3 6
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
GS-R22T81-RH Cable Routing
No Suggest Cable
1 D-Sub cable
2 SAS to SATA * cable (B/P to onboard
SATA) with SGPIO
3 Power cable for CPU
4 Fan Kit cables
No Suggest Cable
5 VGA cable
6 Front I/O + USB cables
7 SMBus cable
8 Power cable
9 Case open instrusion cable
1
5
5
4 4 4
4 4 4
6
2
22
3
36
6
7
8
9
9
![Page 37: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/37.jpg)
3 7
Connector Icon Description
Connector Icon Description
Suggest Icon Description
Keyboard
VGA
Mouse
LAN
COM
USB
![Page 38: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/38.jpg)
3 8
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Motherboard Placement and Jumper SettingGA-7TTSH-RH Motherboard Component
SATA0 SATA2
SATA3SATA1
SATA4
SATA5
27
26
2830 2935 3133 3432
2
1
48 49
508
15
20
36
4
3
5
6 7
9
10
11
12
17
13
18
19
14
23
22
2425
21
37
39
38
40
41
42
44
43
46
45
47
16
![Page 39: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/39.jpg)
3 9
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
No. Code Description
1. CPU1 Processor 1 socket2. CPU2 Processor 2 socket3. U82 Intel Tylersburg-36D IOH4. U60 Intel ICH10R5. U27 ITE IT8720F6. U5 ServerEngines PilotII7. U6 Intel 82576EB GbE8. U23 Broadcom BCM5221PHY9. U190 Winbond W83792G10. U8 BIOS Flash ROM11. F_USB1 Front USB cable connector12. F_USB2 Front USB cable connector13. USB_A1 USB Type A connector14. SSD_USB1 USB SSD Type connector15. SGPIO_JP1 SGPIO connector for BP board 116. SGPIO_JP2 SGPIO connector for BP board 217. PSMI1 PSMI connector18. IPMB1 IPMB1 connector19. IPMB2 IPMB2 connector20. COMB Serial port connector21. SATA0-5 SATA data cable cable connectors*22. CPU1_FAN CPU1 fan cable connector23. CPU2_FAN CPU2 fan cable connector24. PCI-EX8_RR Low-profile PCI-E riser slot25. PCI-EX8_RU/PCI-EX8_RD Full-height PCI-E riser slot26. DIMMA1-A2 DDR3 sockets for processor 1
DIMMB1-B2DIMMC1-C2
27. DIMMD1-D2 DDR3 sockets for processor 2DIMME1-E2DIMMF1-F2
![Page 40: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/40.jpg)
4 0
Motherboard ComponontsNo. Code Description
28. KB_MS1 Keyboard/Mouse ports29. GLAN1 Gigabit LAN ports30. COMA_VGA Serial/VGA ports31. RLAN_L1 i-KVM LAN Port32. R_USB1 USB 2.0 port33. R_USB2 USB 2.0 port34. R_USB3 USB 2.0 port35. R_USB4 USB 2.0 port36. SW1 ID Switch37. ATX_12V1 24-pin Power connector38. SSI_2X4P1 8-pin Power connector39. SSI_2X4P2 8-pin Power connector40. TPM_20 TPM connector41. F_PANEL1 Front panel connector42. BAT CMOS Battery43. CLR_CMOS Clear CMOS jumper44. BIOS_RVCR BIOS Recovery jumper45. CLR_RTC Clear RTC jumper46. PASS_DIS Skip Supervisor password jumper47. BMC_SEL BMC Selection jumper48. JP_STRP8 PilotII firmware upgrade jumper49. JP_STRP2 PilotII firmware upgrade jumper50. PILOT_DIS PilotII Force Mode jumper
![Page 41: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/41.jpg)
4 1
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Motherboard Jumper Setting 43 ) CLR_CMOS (Clear CMOS jumper)You may clear the CMOS data to its default values by this jumper.Default value doesn’t include the “Shunter” to prevent from improper use this jumper. Toclear CMOS, temporarily short 2-3 pin.
1-2 close: Normal operation (Default setting)
2-3 close: Clear CMOS
1
1
44 ) BIOS_REV (BIOS Revocery jumper)
1
1
1-2 close: Normal operation. (Default setting)
2-3 close: Enable BIOS Recovery function.
46 ) PASS_DIS (Skip Supervisor password jumper)
1
1
1-2 Close: Normal operation. (Default setting)
2-3 Close: Clear Supervisor Password in BIOS setup menu.
47 ) BMC_SEL (BMC Selection jumper)
1-2 Close: Normal operation. (Default setting)1
1 2-3 Close: Enable BMC function.
45 ) CLR_RTC (Clear RTC jumper)
1
1 2-3 close: Clear RTC status
1-2 close: Normal operation. (Default setting)
![Page 42: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/42.jpg)
4 2
Jumper Setting
48/49 ) JP_STRAP2/ JP_STRAP8 (PilotII firmware upgrade jumper)
JP_STRAP2 JP_STRAP8 Descripeion
Boot from BMC BOOT SPI Interface. (Default setting)
Boot From BMC LPC BOOT ROM interface.
Boot From internal ROM(Scratchpad Registers)
Boot From internal ROM(Scratchpad Registers)
1
1
1
1
1
1
1
1
1-2 close: Normal operation (Default setting)
2-3 close: Disable PilotII device function.
1
1
50 ) PILOT_DIS (PilotII Force Mode jumper)
![Page 43: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/43.jpg)
4 3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Expansion Card Components DescriptionThe two riser cards installed in the PCI riser card bracket assembly povides support for both full-
heoght and low-profile expansion cards.
Full height and low profile PCI Express riser cards
SLOT_3
SLOT_2
SLOT_1
SLOT_5
SLOT_4
![Page 44: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/44.jpg)
4 4
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
No. Code Description
1 PCI_3 PCI express 2.0 x8 slot
(PCI Express 2.0 x8 throughtput)
2 PCI_2 PCI express 2.0 x8 slot
(PCI Express 2.0 x8 throughtput)
3 PCI_1 PCI express 2.0 x8 slot
(PCI Express 2.0 x8 throughtput)
4 PCI_5 PCI express 2.0 x8 slot
(PCI Express 2.0 x4 throughtput)
5 PCI_4 PCI express 2.0 x8 slot
(PCI Express 2.0 x8 throughtput)
![Page 45: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/45.jpg)
4 5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Full-height riser PCI-X riser card (Optional)
SLOT_3
SLOT_2
SLOT_1
No. Code Description
1 PCI_3 PCI- X slot
2 PCI_2 PCI express 2.0 x8 slot
(PCI Express 2.0 x8 throughtput)
3 PCI_1 PCI express 2.0 x8 slot
(PCI Express 2.0 x8 throughtput)
![Page 46: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/46.jpg)
4 6
BIOS Setup
<> Move to previous item
<> Move to next item
<> Move to the item in the left hand
<> Move to the item in the right hand
<Esc> Main Menu - Quit and not save changes into CMOS Status Page Setup Menu and
Option Page Setup Menu - Exit current page and return to Main Menu
<+/PgUp> Increase the numeric value or make changes
<-/PgDn> Decrease the numeric value or make changes
<F1> General help, only for Status Page Setup Menu and Option Page Setup Menu
<F2> Reserved
<F3> Reserved
<F4> Reserved
<F6> Reserved
<F7> Reserved
<F8> Reserved
<F9> Load the Optimized Defaults
<F10> Save all the CMOS changes, only for Main Menu
BIOS (Basic Input and Output System) includes a CMOS SETUP utility which allows user toconfigure required settings or to activate certain system features.The CMOS SETUP saves the configuration in the CMOS SRAM of the motherboard.When the power is turned off, the battery on the motherboard supplies the necessary power to theCMOS SRAM.
ENTERING SETUPWhen the power is turned on, press the <F2> button during the BIOS POST (Power-On Self Test)will take you to the CMOS SETUP screen. You can enter the BIOS setup screen by pressing"Ctrl + F1".
CONTROL KEYS
BIOS Setup
![Page 47: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/47.jpg)
4 7
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
GETTING HELP
Main Menu
The on-line description of the highlighted setup function is displayed at the bottom of the screen.
Status Page Setup Menu / Option Page Setup Menu
Press F1 to pop up a small help window that describes the appropriate keys to use and the
possible selections for the highlighted item. To exit the Help Window press <Esc>.
Select the Load Setup Defaults item in the BIOS Exit Setup menu when somehow
the system is not stable as usual. This action makes the system reset to the default
settings for stability.
Main
This setup page includes all the items in standard compatible BIOS.
Advanced
This setup page includes all the items of Phoenix BIOS special enhanced features.
(ex: Auto detect fan and temperature status, automatically configure hard disk parameters.)
Power
This setup page includes all the items of Green function features.
Security
Change, set, or disable password. It allows you to limit access the system and setup.
Server
Server additional features enabled/disabled setup menus.
Boot
This setup page include all the items of first boot function features.
Exit
There are five optionsin this selection: Exit Saving Changes, Exit Discarding Changes, Load
Optimal Defaults, Load Failsafe Defaults, and Discard Changes.
![Page 48: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/48.jpg)
4 8
BIOS Setup
System Date Set the System Date. Note that the “Day” automatically changed after you set the date.
System Time
The time is calculated based on the 24-hour military time clock. Set the System Time
(HH:MM:SS)
BIOS Version/BIOS Date
This category includes the information of current BIOS version and BIOS released date.
CPU Type/CPU Speed/ CPU Count
This category includes the information of CPU type, Speed ,and number of CPU count.
MainOnce you enter Phoenix BIOS Setup Utility, the Main Menu (Figure 1) will appear on the screen. Use
arrow keys to select among the items and press <Enter> to accept or enter the sub-menu.
Figure 1: Main
![Page 49: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/49.jpg)
4 9
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Total MemorySize
The BIOS determines total memory is present during the POST.
![Page 50: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/50.jpg)
5 0
BIOS Setup
Figure 2: Advanced
AdvancedAbout This Section: Advanced
With this section, allowing user to configure your system for advanced operation. User can
set the Processor configuration, Memory configuration, Advanced chipset configuration, PCI
configuration , SATA configuration, I/O device configuration, Boot configuration, and Thermal and
acoustic configuration.
![Page 51: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/51.jpg)
5 1
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Processor Configuration
![Page 52: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/52.jpg)
5 2
BIOS Setup
Figure 2-1: Processor Configuration
Processor Configuration
This category includes the information of CPU Speed, Processor ID ,Processor L2 / L3
Cache, and QPI Frequency. And setup sub-menu for CPU Power Management.
Please note that setup menu options will be variable depends on the type of CPU.
Multiprocessor Specification
This option allows user to configure the multiprocessor(MP) specification revision level.
Some operating system will require 1.1 for compatibility reasons.
1.4 Support MPS Version 1.4 . (Default setting)
1.1 Support M PS Version 1.1.
Intel (R) Virtualization Technology
Intel(R) Virtualization Technology will allow a platform to run multiple operating systems and
applications in independent partitions. With virtualization, one computer system can function as
multiple “virtual” systems. With processor and I/O enhancements to Intel’s various platforms,
Intel Virtualization Technology can improve the performance and robustness of today’s software-
only virtual machine solutions.
![Page 53: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/53.jpg)
5 3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Enabled Enable Intel Virtualization Technology. (Default setting)
Disabled Disable this function.
Execute Disable Bit
Enabled Enable Execute Disable Bit. (Default setting)
Disabled Disable this function.
Hardware Prefetcher
The Hardware Prefetcher looks the streams of data. The data is prefetched into L2 from external
memory. Disabling of this item may impact processor performance.
Enabled Enabled Hardware Prefetcher. (Default setting)
Disabled Disables this function. IP Prefetcher
Adjacent Cache Line Prefetch
When enable this item, both cache lines that comprise a cache line pair when it determines data
required is not currently in its cache.
Enabled Adjacent Cache Line Prefetch. (Default setting)
Disabled Disables this function.
CPU Thermal Trip
Enabled Enable CPU Thermal Trip. (Default setting)
Disabled Disable CPU Thermal Trip.
BMC Action for CPU Thermal Trip
Options No Action, Power Off, Power Cycle. Default setting is Power off.
Processor Retest
Enabled Enable Processor Retest.
Disabled Disable Processor Retest. (Default setting)
NUMA Aware
Enabled Enable NUMA Aware. (Default setting)
Disabled Disable NUMA Aware.
ACPI SRAT Report
Enabled Enable ACPI SRAT Report. (Default setting)
Disabled Disable ACPI SRAT Report.
![Page 54: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/54.jpg)
5 4
BIOS Setup
Active Processor Cores
Options One Core, Two cores, Max Cores. Default setting is Max Cores.
Hyper-Threading Technology
Enabled Enable Intel Hyper Threading Technology. (Default setting)
Disabled Disable Intel Hyper Threading Technology.
A20M Support
Enabled Enable A20M Support. (Default setting)
Disabled Disable A20M Support.
Machine Checking
Enabled Enable Machine Checking. (Default setting)
Disabled Disable Machine Checking.
Fast String Operations
Enabled Enable Fast String Operations. (Default setting)
Disabled Disable Fast String Operations.
Set Max Ext CPUID=3
Enabled Enable Set Max Ext CPUID=3.
Disabled Disable Set Max Ext CPUID=3. (Default setting)
Echo TPR
Enabled Enable Echo TPR.
Disabled Disable Echo TPR.(Default setting)
Discrete MTRR Allocation
Enabled Enable Discrete MTRR Allocation.
Disabled Disable Discrete MTRR Allocation. (Default setting)
Thermal Management
Enabled Enable Thermal Management. (Default setting)
Disabled Disable Thermal Management.
![Page 55: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/55.jpg)
5 5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Processor Power Management
Figure 2-1-1: Processor Power Management
EIST (GV3) & C State
Enabled Enable EIST (GV3) and C State items. (Default setting)
Disabled Disable EIST (GV3) and C State items.
EIST (GV3)
Enabled Enable EIST (GV3. (Default setting)
Disabled Disable EIST (GV3).
EIST PSD Function
HW_ALL In HW_ALL mode, the rpocessor hardware is responsible for coordinating
the P-state among logical processors dependencies. The OS is responsible
for keeping the P-state request up to date on all logical processors.
(Default setting)
![Page 56: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/56.jpg)
5 6
BIOS Setup
SW_ALL In SW_ALL mode, the OS Power Manager is responsible for coordinating
the P-state among loical processors with dependencies and must initiate the
transition on all of those Logical Processors.
SW_ANY In SW_ANY mode, the OS Power Manager is responsible for corrdinating
the P-state among logical processors with dependencies and may initiate
the transition on any of those Logical Processors .
Turbo Mode
Turbo Mode automatically allows processor cores to run faster than marked frequency if the
physical processor is operating below power, temperature and current specification limits.
Turbo Mode can be engaged with SMT (Simultanceous Multi Threading) enabled and 1 to 4 cores
active and is not limited to only a single core or logical processor.
Enabled Turbo Mode. (Default setting)
Disabled Disable Turbo Mode.
T State
Enabled Enable CPU T-State. (Default setting)
Disabled Disable T-State.
CPU C State
Enabled Enable ACPI C-State (C0, C1/C1E, C3, C6 and C7). (Default setting)
Disabled Disable C-State.
CPU C1E
Enabled Enable CPU C1E. (Default setting)
Disabled Disable CPU C1E.
OS ACPI C3 Report
C3 Desire state for the Nehalem core C3 state include in the CST as ACPI C3
state. (Default setting)
C2 Desire state for the Nehalem core C2 state include in the CST as ACPI C2
state.
Disabled Disable OS ACPI C3 Report.
CPU C6 Report
Enabled Desire state for the Nehalem core C6 state include in the CST as ACPI C3
![Page 57: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/57.jpg)
5 7
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
state. (Default setting)
Disabled Disable CPU C6 Report.
CPU C7 Report
Enabled Desire state for the Nehalem core C7 state include in the CST as ACPI C3
state. (Default setting)
Disabled Disable CPU C7 Report.
Package C State Limit
Desired state for the C-State package limit.
Options C0, C1 State, C3 State, C6 State, C7 State, No Limit. The default setting
is C3 State.
ACPI MWAIT extensions
Enabled CST using MWAIT extension isenabled for OSPM use. (Default setting)
Disabled Disable ACPI MWAIT extensions.
![Page 58: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/58.jpg)
5 8
BIOS Setup
Memory Configuration
![Page 59: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/59.jpg)
5 9
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
System Memory/Extended Memory/Memory Frequency/DIMM Status
These category is display-only which is determined by POST (Power On Self Test) of the
BIOS.
Memory Reset
Yes Select ‘Yes’, system will clear the memory error status. Save the
changes and restart system. After rebooting system, the Memory
Reset item will set to ‘No’ automatically.
No No chnages. (Default setting)
Memory Control Settings
Manual Select ‘Manual” will pops up sub-menu for configuration.
Auto Auto configuration. (Default setting)
Memory RAS Mode
Identify the Memory RAS mode.
Memory Frequency
Select the desire value of Memory frequency. Options available: Auto, DDR-3 800,
DDR-3 1066, and DDR-3 1333.
Change Interleave setting
Change the interleave setting. Options available: 1-way, 2-way, 3-way, 4-way, and 6-way.
Rank Interleave setting
Configure interleave setting. Options available: 1-way, 2-way, and 4-way.
![Page 60: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/60.jpg)
6 0
BIOS Setup
Advanced Chipset Configuration
![Page 61: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/61.jpg)
6 1
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Figure 2-3-1: Intel VT for Directed I/O (VT-d)
![Page 62: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/62.jpg)
6 2
BIOS Setup
Intel VT for Directed I/O (VT-d)
Interrupt Remapping
Enabled Enable Interrupt Remapping. (Default setting)
Disabled Disable Interrupt Remapping.
Coherency Support
Enabled Enable Coherency Support.
Disabled Disable Coherency Support. (Default setting)
ATS
Enabled Enable ATS. (Default setting)
Disabled Disable ATS.
PassThrough DMA
Enabled Enable PassThrough DMA. (Default setting)
Disabled Disable PassThrough DMA.
VT-d for Port1~Port 10
Enabled Enable VT-d support for Port 1~Port 10 ports through ATSR structures in
ACPI Tables. (Default setting)
Disabled Disable VT-d for Port1~Port 10.
Advanced Chipset Control Main Menu Options
Course Grain Clocking Gating
Enabled Enable Course Grain Clocking Gating.
Disabled Disable Course Grain Clocking Gating. (Default setting)
Intel (R) I/OAT
Enabled Enable configuration mapped accesses to the I/OAT configuration sapce.
(Default setting)
Disabled Disable I/OAT.
4GB PCI HoleGranularity
Select the granularity of PCI hole for PCI resource. If MTRRS are not enough, we may use
this option to reduce the MTRR occupation.
512MB Select 512MB as granularity of PCI hole.
1GB Select 1GB as granularity of PCI hole. (Default setting)
2GB Select 2GB as granularity of PCI hole.
![Page 63: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/63.jpg)
6 3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
QPI Control Settings
Enabled Enable QPI Control settings. (Default setting)
Disabled QPI Control settings.
QPI Link Fast Mode
Enabled Enable QPI Link Fast Mode. (Default setting)
Disabled Disable QPI Link Fast Mode.
QPI Frequency Selection
Identify the desire value of QPI frequency. Option available: Auto, 4.800GT, 5.866GT.
Default setting is Auto.
QPI Isoch Support
Enabled Enable QPI Isoch Support.
Disabled Disable QPI Isoch Support. (Default setting)
QPI DCA Support
Enabled Enable QPI DCA Support. (Default setting)
Disabled Disable QPI DCA Support.
QPI scramble selection
Enabled Enable QPI scramble selection.
Disabled Disable QPI scramble selection. (Default setting)
QPI Error Report
Enabled Enable QPI Error Report.
Disabled Disable QPI Error Report. (Default setting)
Memory ECC Error Log
Identify the the memory ecc error log. Option available: Disable, Correctable Error,
Uncorrectable Error, and Both. The default setting is Both.
ECC Threshold
Use the “+” and “-” keys to adjust the desire value of ECC Threshold.
Unconrrectable Pass to OS
Enabled Enable Unconrrectable Pass to OS. (Default setting)
Disabled Disable Unconrrectable Pass to OS.
Enable Multimedia Timer
Yes Enable Multimedia Timer support. (Default setting)
No Disable this function.
![Page 64: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/64.jpg)
6 4
BIOS Setup
PCI Configuration
Figure 2-4: PCI Configuration
PCI Slot 1/2/3/4/5 Option ROM
Enabled Enable this item to initialize device expansion ROM.
(Defualt setting)
Disabled Disable this function.
Onboard VGA Controller
Enabled Enable Onboard VGA device. (Defualt setting)
Disabled Disable this function.
Onboard LAN iSCSI Boot ROM
Enabled Enable Onboard LAN iSCSI Boot ROM.
Disabled Disable this function. (Defualt setting)
Onboard LAN1 Controller
Enabled Enable Onboard LAN controller. (Defualt setting)
Disabled Disable this function.
![Page 65: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/65.jpg)
6 5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
LAN1Option ROM
Enabled Enable onboard LAN1 device and initialize device expansionROM. (Default setting)
Disabled Disable this function.
Onboard LAN2 Controller
Enabled Enable Onboard LAN controller. (Defualt setting)
Disabled Disable this function.
LAN2Option ROM
Enabled Enable onboard LAN2 device and initialize device expansionROM. (Default setting)
Disabled Disable this function.
Legacy USB Support
This option allows user to function support for legacy USB.
Enabled Enables support for legacy USB (Default setting)
Disabled Disables support for legacy USB.
![Page 66: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/66.jpg)
6 6
BIOS Setup
SATA Configuration
Figure 2-5: SATA Configuration
![Page 67: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/67.jpg)
6 7
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Serial ATA
Enabled Enables on-board serial ATA function. (Default setting)
Disabled Disables on-board serial ATA function.
Native Mode Operation
This option allows user to set the native mode for Serial ATA function.
Auto Auto detected. (Default setting)
Serial ATA Set Native mode to Serial ATA.
SATA Controller Mode Option
Compatible Mode SATA and PATA drives are auto-detected and placed inLegacy mode.
Enhanced Mode SATA and PATA drives are auto-detected and placed in
Native mode. (Default setting)
Note: Pre-Win2000 operating system do not work in Enhanced mode.
SATA RAID Enable
Enabled Enabled SATA RAID function.
Disabled Disable this function. (Default setting)
SATA AHCI Enable
Enabled Set this item to enable SATA AHCI function for WinXP-SP1+IAA
driver supports AHCI mode.
Disabled Disabled this function. (Default setting)
SATA Port 0/1/2/3/4/5
The category identifies the types of Serial SATA hard disk from drive 0 to 5 that has been
installed in the computer. System will automatically detect HDD type.
Note that the specifications of your drive must match with the drive table. The hard disk will not
work properly if you enter improper information for this category.
Hard drive information should be labled on the outside device casing. Enter the appropriate option
based on this information.
TYPE
1-39: Predefined types.
Users: Set parameters by User.
![Page 68: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/68.jpg)
6 8
BIOS Setup
Auto: Set parameters automatically. (Default setting)
CD-ROM: Use for ATAPI CD-ROM drives or double click [Auto] to set all HDD parameters
automatically.
ATAPI Removable: Removable disk drive is installed here.
Multi-Sector Transfer
This field displays the information of Multi-Sector Transfer Mode.
Disabled: The data transfer from and to the device occurs one sector at a time.
Auto: The data transfer from and to the device occurs multiple sectors at a time if the device
supports it.
LBA Mode Control This field shows if the device type in the specific IDE channel
support LBA Mode.
32-Bit I/O Enable this function to max imize the IDE data transfer rate.
Transfer Mode This field shows the information of Teansfer Mode.
Ultra DMA Mode This filed displays the DMA mode of the device in the specific IDE
channel.
![Page 69: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/69.jpg)
6 9
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
I/O DeviceConfiguration
Serial Port A
This allows users to configure serial prot A by using this option.
Enabled Enable the configuration. (Default setting)
Disabled Disable the configuration.
Base I/O Address/IRQ
3F8/IRQ4 Set IO address to 3F8/IRQ4.(Default setting)
2F8/IRQ3 Set IO address to 2F8/IRQ3.
3E8/IRQ7 Set IO address to 3E8/IRQ7.
2E8/IRQ5 Set IO address to 2E8/IRQ5.
Serial Port B
This allows users to configure serial prot B by using this option.
Enabled Enable the configuration (Default setting)
Disabled Disable the configuration.
Figure 2-6: I/O Device Configuration
![Page 70: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/70.jpg)
7 0
BIOS Setup
Base I/O Address/IRQ
3F8/IRQ4 Set IO address to 3F8/IRQ4.
2F8/IRQ3 Set IO address to 2F8/IRQ3. (Default setting)
3E8/IRQ7 Set IO address to 3E8/IRQ7.
2E8/IRQ5 Set IO address to 2E8/IRQ5.
PS/2 Mouse
Set this option ‘Enabled’ to allow BIOS support for a PS/2 - type mouse.
Enabled ‘Enabled’ forces the PS/2 mouse port to be enabled regardless if amouse is present. (Default setting)
Disabled ‘Disabled’ prevents any installed PS/2 mouse from functioning,but frees up IRQ12.
![Page 71: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/71.jpg)
7 1
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Boot Configuration
Boot -time Diagnostic Screen
When this item is enabled, system will shows Diagnostic status when system boot.
Enabled Enable Boot-time Diagnostic.
Disabled Disable this function. (Default setting)
Post Error Pause
The category determines whether the computer will stop if an error is detected during power up.
All Error Whenever the BIOS detects a non-fatal error the system will be
stopped.
No Error The system boot will not stop for any error that may be detected
and you will be prompted.
All, But Keyboard The system boot will not stop for a keyboard error; it will stop for all
other errors. (Default setting)
Figure 2-7: Boot Configuration
![Page 72: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/72.jpg)
7 2
BIOS Setup
NumLock
This option allows user to select power-on state for NumLock.
On Enable NumLock. (Default setting)
Off Disable this function.
![Page 73: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/73.jpg)
7 3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Thermal and Acoustic Configuration
Figure 2-8: Thermal and Acoustic Configuration
Open loop Thermal Throttle
Enabled Open loop Thermal Throttle. (Default setting)
Disabled Disable Open loop Thermal Throttle.
Temperature Chassis inlet
This item is user defined. Use nuber key to adjust desired value.
Temperature Rise
This item is user defined. Use nuber key to adjust desired value.
Air speed to the DIMMs
This item is user defined. Use nuber key to adjust desired value.
System Altitude
This item is user defined. Use nuber key to adjust desired value.
Pitch between DIMMs
This item is user defined. Use nuber key to adjust desired value.
![Page 74: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/74.jpg)
7 4
BIOS Setup
Close loop Thermal Throttle
Enabled Close loop Thermal Throttle. (Default setting)
Disabled Disable Close loop Thermal Throttle.
Temperature hysteresis
This item is user defined. Use nuber key to adjust desired value.
Temperature guardband
This item is user defined. Use nuber key to adjust desired value.
Temperature Chassis inlet
This item is user defined. Use nuber key to adjust desired value.
Temperature Rise
This item is user defined. Use nuber key to adjust desired value.
Air speed to the DIMMs
This item is user defined. Use nuber key to adjust desired value.
System Altitude
This item is user defined. Use nuber key to adjust desired value.
Pitch between DIMMs
This item is user defined. Use nuber key to adjust desired value.
![Page 75: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/75.jpg)
7 5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Power
Figure 3: Power
Power on by RTC Alarm
You can set item to Enabled and key in Date/Time to power on system.
On Enable alarm function to POWER ON system.
Off Disable this function. (Default setting)
If Resume On Time is Enabled.
Resume Date Everyday, 1~31
Resume Time (0~23) : (0~59) : (0~59)
Power On PCI & PCIE Devices
Enabled Enable Power On PCIe Devices. (Default setting)
Disabled Disable this function.
Power On by Modem Ring
Enabled Enable Power On by Modem Ring. (Default setting)
Disabled DisablePower On by Modem Ring.
![Page 76: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/76.jpg)
7 6
BIOS Setup
Wake Up by PS/2 KB/Mouse
Enabled Enable Wake Up by PS/2 KB/Mouse. (Default setting)
Disabled Disable Wake Up by PS/2 KB/Mouse function.
Wake Up by USB KB/Mouse
Enabled Enable Wake Up by USB KB/Mouse. (Default setting)
Disabled Disable Wake Up by USB KB/Mouse function.
After Power Failure
This option provides user to set the mode of operation if an AC / power loss occurs.
Power On System power state when AC cord is re-plugged.
Stay Off Do not power on system when AC power is back.
Last State Set system to the last sate when AC power is removed. Do not power onsystem when AC power is back. (Default setting)
![Page 77: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/77.jpg)
7 7
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Security
Figure 4: Security
Set Supervisor Password
You can install and change this options for the setup menus. Type the password up to 6
characters in lengh and press <Enter>. The password typed now will clear any previously
entered password from the CMOS memory. You will be asked to confirm the entered
password. Type the password again and press <Enter>. You may also press <Esc> to abort
the selection and not enter a specified password or press <Enter> key to disable this option.
About This Section: Security
In this section, user can set either supervisor or user passwords, or both for different level of
password securities. In addition, user also can set the virus protection for boot sector.
![Page 78: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/78.jpg)
7 8
BIOS Setup
Set User Password
You can only enter but do not have the right to change the options of the setup menus. When
you select this function, the following message will appear at the center of the screen to assist
you in creating a password.
Type the password up to 6 characters in lengh and press <Enter>. The password typed now
will clear any previously entered password from the CMOS memory. You will be asked to
confirm the entered password. Type the password again and press <Enter>. You may also
press <Esc> to abort the selection and not enter a specified password.
Password on boot
Password entering will be required when system on boot.
Enabled Requries entering password when system on boot.
Disabled Disable this function. (Default setting)
Security Mode for PWR/RST Button
Enabled Enable Security Mode for PWR/RST Button.
Disabled Disable this function. (Default setting)
Clear Case Open Status
Press [Enter] to clear the case open status.
TPM Support
TPM, stands for Trusted Platform Module. A Trusted Platform Module provides function for
secure generation of cryptographic keys, the ability to limit the use of cryptographic keys, as
well as a hardware pseudo-random number generator.
Enabled Enable TPM Support.
Disabled Disable this function. (Default setting)
Current TPM State
Displays the current TPM State status.
Change TPM State
No Change No configuration on TPM State. (Default setting)
Enable & Activate Enable and activate TPM State.
Deactivate & Disable Disable and deactivate TPM State.
Clear Clear the TPM stored information on the TPM.
![Page 79: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/79.jpg)
7 9
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Server
Figure 5: Server
![Page 80: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/80.jpg)
8 0
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
System Management
Figure 5-1: System Management
![Page 81: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/81.jpg)
8 1
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
System Management
This category allows user to view the system management features. Including information of
Motherboard Hardware information and software information.
BMC IP Address Source
Address obtained by BMC running DHCP or Static address.
Option available: DHCP, Static.
![Page 82: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/82.jpg)
8 2
BIOS Setup
Figure 5-2: Console Redirection
Console Redirection
Console Redirection
If this option is set to enabled, it will use a port on the motherboard to run console redirection
function.
On-board COM A Use Serial Port A as the COM port address.
On-board COM B Use Serial Port B as the COM port address.
Disabled Disable this function. (Default setting)
Flow ControlThis option provide user to enable the flow control function.
None Not supported.
XON/XOFF Software control.
CTS/RTS Hardware control. (Default setting)
Baud Rate
![Page 83: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/83.jpg)
8 3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
This option allows user to set the specified baud rate.
Options 300, 1200, 2400, 9600, 19.2K, 38.4K, 57.6K, 115.2K.
Terminal Type
This option allows user to select the specified terminal type. This is defined by IEEE.
Options VT100, VT100 8bit, PC-ANSI 7bit, PC-ANSI, VT100+, VT-UTF8,ASCII.
Continue C.R. after POST
This option allows user to enable console redirection after O.S has loaded.
On Enable console redirection after O.S has loaded.
Off Disable this function. (Default setting)
![Page 84: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/84.jpg)
8 4
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Event Log Configuration
Figure 5-3: Event Log Configuration
Assert NMI on SERR
Enabled Enable Assert NMI on SERR function. (Default setting)
Disabled Disable this function.
Assert NMI on PERR
Enabled Enable Assert NMI on PERR function. (Default setting)
Disabled Disable this function.
Clear all Event Logs
Press [Enter] to clear all event logs.
Log POST System Event
Enabled Enable Log POST System Event. (Default setting)
Disabled Disable this function.
![Page 85: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/85.jpg)
8 5
BIOS Setup
Boot
Figure 6: Boot
Boot Priority Order
This field determines which type of device the system attempt to boot from after
PhoenixBIOS Post completed. Specifies the boot sequence from the available devices. If
the first device is not a bootable device, the system will seek for next available device.
Key used to view or configure devices:
Up and Down arrows select a device.
<+> and <-> moves the device up or down.
<f> and <r> specifies the device fixed or removable.
<x> exclude or include the device to boot.
<Shift + 1> Enable or disable a device.
<1-4> Loads default boot secquence.
![Page 86: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/86.jpg)
8 6
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Exit
Figure 7: Exit
About This Section: ExitOnce you have changed all of the set values in the BIOS setup, you should save your
changes and exit BIOS setup program. Select “Exit” from the menu bar, to display the
following sub-menu.
Exit Saving Changes
Exit Discarding Changes
Load Settup Default
Discard Changes
Save Changes
![Page 87: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/87.jpg)
8 7
BIOS Setup
Exit Saving Changes
This option allows user to exit system setup with saving the changes.
Press <Enter> on this item to ask for the following confirmation message:
Pressing ‘Y’ to store all the present setting values tha user made in this time into CMOS.
Therefore, whenyou boot up your computer next time, the BIOS will
re-configure your system according data in CMOS.
![Page 88: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/88.jpg)
8 8
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Exit Discarding ChangesThis option allows user to exit system setup without changing anyprevious settings values in
CMOS. The previous selection remain in effect.
This will exit the Setup Utility and restart your compuetr when selecting this option.
![Page 89: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/89.jpg)
8 9
BIOS Setup
Load Settup Default
This option allows user to load default values for all setup items.
When you press <Enter> on this item, you will get a confirmation dialog box with a message
as below:
![Page 90: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/90.jpg)
9 0
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Discard ChangesThis option allows user to load previos values from CMOS for all setup item.
When you press <Enter> on this item, you will get a confirmation dialog box with a message
as below:
![Page 91: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/91.jpg)
9 1
BIOS Setup
Save Changes
This option allows user to save setup dat ato CMOS.
When you press <Enter> on this item, you will get a confirmation dialog box with a message
as below:
Press [Yes] to save setup data to CMOS.
![Page 92: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/92.jpg)
Appexdix
9 2
Code Beeps POST Routine Description02h Verify Real Mode03h Disable Non-Maskable Interrupt (NMI)04h Get CPU type06h Initialize system hardware08h Initialize chipset with initial POST values09h Set IN POST flag0Ah Initialize CPU registers0Bh Enable CPU cache0Ch Initialize caches to initial POST values0Eh Initialize I/O component0Fh Initialize the local bus IDE10h Initialize Power Management11h Load alternate registers with initial POST values12h Restore CPU control word during warm boot13h Initialize PCI Bus Mastering devices14h Initialize keyboard controller16h 1-2-2-3 BIOS ROM checksum17h Initialize cache before memory autosize18h 8254 timer initialization1Ah 8237 DMA controller initialization1Ch Reset Programmable Interrupt Controller20h 1-3-1-1 Test DRAM refresh22h 1-3-1-3 Test 8742 Keyboard Controller24h Set ES segment register to 4 GB26h Enable A20 line28h Autosize DRAM29h Initialize POST Memory Manager2Ah Clear 512 KB base RAM2Ch 1-3-4-1 RAM failure on address line xxxx*2Eh 1-3-4-3 RAM failure on data bits xxxx* of low byte of memory bus2Fh Enable cache before system BIOS shadow30h 1-4-1-1 RAM failure on data bits xxxx* of high byte of memory bus32h Test CPU bus-clock frequency33h Initialize Phoenix Dispatch Manager36h Warm start shut down38h Shadow system BIOS ROM3Ah Autosize cache3Ch Advanced configuration of chipset registers
Appexdix A Phoenix BIOS Beep Codes
![Page 93: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/93.jpg)
9 3
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Code Beeps POST Routine Description3Dh Load alternate registers with CMOS values42h Initialize interrupt vectors45h POST device initialization46h 2-1-2-3 Check ROM copyright notice48h Check video configuration against CMOS49h Initialize PCI bus and devices4Ah Initialize all video adapters in system4Bh QuietBoot start (optional)4Ch Shadow video BIOS ROM4Eh Display BIOS copyright notice50h Display CPU type and speed51h Initialize EISA board52h Test keyboard54h Set key click if enabled58h 2-2-3-1 Test for unexpected interrupts59h Initialize POST display service5Ah Display prompt "Press F2 to enter SETUP"5Bh Disable CPU cache5Ch Test RAM between 512 and 640 KB60h Test extended memory62h Test extended memory address lines64h Jump to UserPatch166h Configure advanced cache registers67h Initialize Multi Processor APIC68h Enable external and CPU caches69h Setup System Management Mode (SMM) area6Ah Display external L2 cache size6Bh Load custom defaults (optional)6Ch Display shadow-area message6Eh Display possible high address for UMB recovery70h Display error messages72h Check for configuration errors76h Check for keyboard errors7Ch Set up hardware interrupt vectors7Eh Initialize coprocessor if present80h Disable onboard Super I/O ports and IRQs81h Late POST device initialization82h Detect and install external RS232 ports83h Configure non-MCD IDE controllers84h Detect and install external parallel ports
![Page 94: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/94.jpg)
Appexdix
9 4
Code Beeps POST Routine Description85h Initialize PC-compatible PnP ISA devices86h Re-initialize onboard I/O ports.87h Configure Motheboard Configurable Devices (optional)88h Initialize BIOS Data Area89h Enable Non-Maskable Interrupts (NMIs)8Ah Initialize Extended BIOS Data Area8Bh Test and initialize PS/2 mouse8Ch Initialize floppy controller8Fh Determine number of ATA drives (optional)90h Initialize hard-disk controllers91h Initialize local-bus hard-disk controllers92h Jump to UserPatch293h Build MPTABLE for multi-processor boards95h Install CD ROM for boot96h Clear huge ES segment register97h Fixup Multi Processor table98h 1-2 Search for option ROMs. One long, two short beeps on checksum failure99h Check for SMART Drive (optional)9Ah Shadow option ROMs9Ch Set up Power Management9Dh Initialize security engine (optional)9Eh Enable hardware interrupts9Fh Determine number of ATA and SCSI drivesA0h Set time of dayA2h Check key lockA4h Initialize Typematic rateA8h Erase F2 promptAAh Scan for F2 key strokeACh Enter SETUPAEh Clear Boot flagB0h Check for errorsB2h POST done - prepare to boot operating systemB4h 1 One short beep before bootB5h Terminate QuietBoot (optional)B6h Check password (optional)B9h Prepare BootBAh Initialize DMI parametersBBh Initialize PnP Option ROMsBCh Clear parity checkersBDh Display MultiBoot menuBEh Clear screen (optional)
![Page 95: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/95.jpg)
9 5
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
Code Beeps POST Routine DescriptionBFh Check virus and backup remindersC0h Try to boot with INT 19C1h Initialize POST Error Manager (PEM)C2h Initialize error loggingC3h Initialize error display functC4h Initialize system error handlerC5h PnPnd dual CMOS (optional)C6h Initialize notebook docking (optional)C7h Initialize notebook docking lateC8h Force check (optional)C9h Extended checksum (optional)D2h Unknown interrupt
Code Beeps For Boot Block in Flash ROME0h Initialize the chipsetE1h Initialize the bridgeE2h Initialize the CPUE3h Initialize system timerE4h Initialize system I/OE5h Check force recovery bootE6h Checksum BIOS ROME7h Go to BIOSE8h Set Huge SegmentE9h Initialize Multi ProcessorEAh Initialize OEM special codeEBh Initialize PIC and DMAECh Initialize Memory typeEDh Initialize Memory sizeEEh Shadow Boot BlockEFh System memory testF0h Initialize interrupt vectorsF1h Initialize Run Time ClockF2h Initialize videoF3h Initialize System Management ModeF4h 1 Output one beep before bootF5h Boot to Mini DOSF6h Clear Huge SegmentF7h Boot to Full DOS
![Page 96: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/96.jpg)
Appexdix
9 6
Appexdix B PhoenixBIOS POST Error Messages
ListThe following is a list of the messages that the BIOS can display. Most of them occur duringPOST. Some of them display information about a hardware device, e.g., the amount of memoryinstalled. Others may indicate a problem with a device, such as the way it has been configured.Following the list are explanations of the messages and remedies for reported problems.
*If your system displays one of the messages marked below with an asterisk (*),write down the message and contact your dealer. If your system fails after youmake changes in the Setup menus, reset the computer, enter Setup and installSetup defaults or correct the error.
0200 Failure Fixed DiskFixed disk is not working or not configured properly. Check to see if fixed disk is attachedproperly. Run Setup. Find out if the fixed-disk type is correctly identified.
0210 Stuck keyStuck key on keyboard.
0211 Keyboard errorKeyboard not working.
*0212 Keyboard Controller FailedKeyboard controller failed test. May require replacing keyboard controller.
0213 Keyboard locked - Unlock key switchUnlock the system to proceed.
0220 Monitor type does not match CMOS - Run SETUPMonitor type not correctly identified in Setup
*0230 Shadow Ram Failed at offset: nnnnShadow RAM failed at offset nnnn of the 64k block at which the error was detected.
*0231 System RAM Failed at offset: nnnnSystem RAM failed at offset nnnn of in the 64k block at which the error was detected.
*0232 Extended RAM Failed at offset: nnnnExtended memory not working or not configured properly at offset nnnn.
0250 System battery is dead - Replace and run SETUPThe CMOS clock battery indicator shows the battery is dead. Replace the battery and runSetup to reconfigure the system.
0251 System CMOS checksum bad - Default configuration usedSystem CMOS has been corrupted or modified incorrectly, perhaps by an application programthat changes data stored in CMOS. The BIOS installed Default Setup Values. If you do notwant these values, enter Setup and enter your own values. If the error persists, check thesystem battery or contact your dealer.
*0260 System timer errorThe timer test failed. Requires repair of system board.
![Page 97: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/97.jpg)
9 7
GS-R22T61-RH/GS-R22T81-RH Rack Mount Server
*0270 Real time clock errorReal-Time Clock fails BIOS hardware test. May require board repair.
0271 Check date and time settingsBIOS found date or time out of range and reset the Real-Time Clock. May require setting legaldate (1991-2099).
0280 Previous boot incomplete - Default configuration usedPrevious POST did not complete successfully. POST loads default values and offers to runSetup. If the failure was caused by incorrect values and they are not corrected, the next bootwill likely fail. On systems with control of wait states, improper Setup settings can also terminate POST and cause this error on the next boot. Run Setup and verify that the waitstateconfiguration is correct. This error is cleared the next time the system is booted.
0281 Memory Size found by POST differed from CMOSMemory size found by POST differed from CMOS.
02B0 Diskette drive A error02B1 Diskette drive B error
Drive A: or B: is present but fails the BIOS POST diskette tests. Check to see that the drive isdefined with the proper diskette type in Setup and thatthe diskette drive is attached correctly.
02B2 Incorrect Drive A type - run SETUPType of floppy drive A: not correctly identified in Setup.
02B3 Incorrect Drive B type - run SETUPType of floppy drive B: not correctly identified in Setup.
02D0 System cache error - Cache disabledRAM cache failed and BIOS disabled the cache. On older boards, check the cache jumpers.You may have to replace the cache. See your dealer. A disabled cache slows systemperformance considerably.
02F0: CPU ID:CPU socket number for Multi-Processor error.
*02F4: EISA CMOS not writeableServerBIOS2 test error: Cannot write to EISA CMOS.
*02F5: DMA Test FailedServerBIOS2 test error: Cannot write to extended DMA (Direct Memory Access) registers.
*02F6: Software NMI FailedServerBIOS2 test error: Cannot generate software NMI (Non-Maskable Interrupt).
*02F7: Fail-Safe Timer NMI FailedServerBIOS2 test error: Fail-Safe Timer takes too long.
Device Address ConflictAddress conflict for specified device.
Allocation Error for: deviceRun ISA or EISA Configuration Utility to resolve resource conflict for the specified device.
CD ROM DriveCD ROM Drive identified.
![Page 98: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/98.jpg)
Appexdix
9 8
Entering SETUP ...Starting Setup program
*Failing Bits: nnnnThe hex number nnnn is a map of the bits at the RAM address which failed the memory test.Each 1 (one) in the map indicates a failed bit. See errors 230, 231, or 232 above for offsetaddress of the failure in System, Extended, or Shadow memory.
Fixed Disk nFixed disk n (0-3) identified.
Invalid System Configuration DataProblem with NVRAM (CMOS) data.
I/O device IRQ conflictI/O device IRQ conflict error.
PS/2 Mouse Boot Summary Screen:PS/2 Mouse installed.
nnnn kB Extended RAM PassedWhere nnnn is the amount of RAM in kilobytes successfully tested.
nnnn Cache SRAM PassedWhere nnnn is the amount of system cache in kilobytes successfully tested.
nnnn kB Shadow RAM PassedWhere nnnn is the amount of shadow RAM in kilobytes successfully tested.
nnnn kB System RAM PassedWhere nnnn is the amount of system RAM in kilobytes successfully tested.
One or more I2O Block Storage Devices were excluded from the Setup Boot MenuThere was not enough room in the IPL table to display all installed I2O block-storage devices.
Operating system not foundOperating system cannot be located on either drive A: or drive C:. EnterSetup and see if fixed disk and drive A: are properly identified.
*Parity Check 1 nnnnParity error found in the system bus. BIOS attempts to locate the address and display it on thescreen. If it cannot locate the address, it displays ????. Parity is a method for checking errorsin binary data. A parity error indicates that some data has been corrupted.
*Parity Check 2 nnnnParity error found in the I/O bus. BIOS attempts to locate the address and display it on thescreen. If it cannot locate the address, it displays ????.
Press <F1> to resume, <F2> to Setup,<F3> for previous
Displayed after any recoverable error message. Press <F1> to start the boot process or <F2>to enter Setup and change the settings. Press <F3> to display the previous screen (usually aninitialization error of an Option ROM, i.e., an add-on card). Write down and follow theinformation shown on the screen.
![Page 99: r22t6 r22t8 1.0 q - GIGABYTE](https://reader034.fdocuments.in/reader034/viewer/2022051217/62792628026680647911263a/html5/thumbnails/99.jpg)
9 9
GS-R22T61-RH/GS-R22T81-RH Rack Mount ServerPress <F2> to enter Setup
Optional message displayed during POST. Can be turned off in Setup.PS/2 Mouse:
PS/2 mouse identified.Run the I2O Configuration Utility
One or more unclaimed block storage devices have the Configuration Request bit set in theLCT. Run an I2O Configuration Utility (e.g. the SAC utility).
System BIOS shadowedSystem BIOS copied to shadow RAM.
UMB upper limit segment address: nnnnDisplays the address nnnn of the upper limit of Upper Memory Blocks, indicating releasedsegments of the BIOS which can be reclaimed by a virtual memory manager.Video BIOS shadowed Video BIOS successfully copied to shadow RAM.