R1 41 01 04 Technical Directive
Transcript of R1 41 01 04 Technical Directive
![Page 1: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/1.jpg)
Author: G. Elffers
Issue: March 1998
Version 1.1
Intended for the Location IJmuiden
This is a non-registered document.
If this document is changed in the future, the amendments will not be sent to you.
The latest version can be retrieved via Intranet http://teweb.hoogovens.com.
Information on
Subject of document Elffers tel. +31 (0)251-4 97927
Standardisation Standardisation office tel. +31 (0)251-4 97693
R1 41 01 04 Technical Directive
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 2: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/2.jpg)
![Page 3: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/3.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Contents:
![Page 4: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/4.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 5: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/5.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1. SUB PLATES, GANGED SUB PLATES AND ACCESSORIES ......................................................................... 49
![Page 6: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/6.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.1. Scope and application ................................................................................................................... 50
![Page 7: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/7.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.2. Subplates ........................................................................................................................................ 63
![Page 8: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/8.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.3. Ganged sub plates ISO 1 and 2 ..................................................................................................... 88
![Page 9: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/9.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.4. Ganged sub plates ISO 3 and 4 .................................................................................................... 106
![Page 10: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/10.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.5. Cover plate .................................................................................................................................. 123
![Page 11: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/11.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2. DIRECTIONAL CONTROL VALVES ACCORDING ISO 5599-1, SIZE 1 - 4 ................................................ 135
![Page 12: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/12.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2.1. Scope and application ................................................................................................................. 136
![Page 13: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/13.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2.2. Symbols ........................................................................................................................................ 143
![Page 14: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/14.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2.3. Technical data ............................................................................................................................. 145
![Page 15: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/15.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2.4. Manufactures and types ............................................................................................................... 163
![Page 16: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/16.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3. PROPORTIONAL PRESSURE CONTROL VALVES ................................................................................... 222
![Page 17: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/17.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3.1. Scope and application .................................................................................................................. 223
![Page 18: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/18.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3.2. Symbol according NEN 3348 (ISO 1219-1) ................................................................................ 227
![Page 19: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/19.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3.3. Technical data manufacturer: Mannesmann, Rexroth ................................................................. 229
![Page 20: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/20.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3.4. Technical data manufacturer: Herion ......................................................................................... 239
![Page 21: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/21.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4. SANDWICH VALVES ACCORDING ISO 5599 ........................................................................................ 253
![Page 22: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/22.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.1. Scope and application ................................................................................................................. 254
![Page 23: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/23.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.2. Throttle valves, sandwich type ..................................................................................................... 257
![Page 24: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/24.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.3. Manufactures and sizes ............................................................................................................... 260
![Page 25: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/25.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4. Reducing valve, sandwich type (ISO) ........................................................................................... 269
![Page 26: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/26.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4.art.a. Reducer function in port 1 ............................................................................................................ 270
![Page 27: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/27.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4.art.b. Reducer function in port 2 ............................................................................................................. 279
![Page 28: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/28.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4.art.c. Reducer function in port 4 ............................................................................................................ 286
![Page 29: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/29.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4.art.d. Reducer function in port 2 and 4 ................................................................................................... 293
![Page 30: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/30.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5. IN LINE VALVES ................................................................................................................................. 302
![Page 31: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/31.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.1. Scope and application .................................................................................................................. 303
![Page 32: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/32.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.2. Symbols according NEN 3348 (ISO 1219-1) ............................................................................... 313
![Page 33: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/33.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.3. Check valves ................................................................................................................................. 315
![Page 34: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/34.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.4. Throttle non return valve, female threaded ................................................................................. 327
![Page 35: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/35.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.5. Shuttle valves, female threaded .................................................................................................... 350
![Page 36: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/36.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.6. Quick exhaust valves, female threaded ........................................................................................ 365
![Page 37: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/37.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.6. "SLOW START" VALVE ....................................................................................................................... 384
![Page 38: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/38.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.6.1. Scope and application ................................................................................................................. 385
![Page 39: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/39.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.6.2. Symbol according NEN 3348 (ISO 1219-1) ................................................................................. 392
![Page 40: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/40.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.6.3. Technical data ............................................................................................................................. 394
![Page 41: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/41.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.7. SHUT OFF VALVES / BALL VALVES PN 16 ........................................................................................... 408
![Page 42: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/42.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.7.1. Ball valves with male thread ends ............................................................................................... 409
![Page 43: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/43.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.7.2. Ball valves for flange mounting.................................................................................................... 428
![Page 44: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/44.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.7.3. Three-way ball valves, male threaded ......................................................................................... 454
![Page 45: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/45.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.8. REFERENCES ...................................................................................................................................... 477
![Page 46: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/46.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.9. EXPLANATION ................................................................................................................................... 501
![Page 47: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/47.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 48: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/48.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 49: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/49.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Blank page
![Page 50: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/50.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 51: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/51.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1. Sub plates, ganged sub plates and accessories
![Page 52: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/52.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.1. Scope and application
![Page 53: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/53.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
For the mounting of valves with a surface according ISO 5599 (see Technical Directive R1
![Page 54: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/54.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
41 01 04E, paragraph 4.2.) ganged sub plates are to be used, with side ports by
![Page 55: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/55.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
preference, because of the assembly in cabinets.
![Page 56: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/56.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
While pipelines often are long, the connection ports are LARGER than described
![Page 57: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/57.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
according VDMA.
![Page 58: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/58.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 59: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/59.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Mounting of a single valve can be done with normal sub plates.
![Page 60: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/60.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 61: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/61.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Coverplates are used when valves are not present on the sub plate position, for example
![Page 62: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/62.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
after a revision, or as a spare position.
![Page 63: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/63.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 64: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/64.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 65: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/65.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.2. Subplates
![Page 66: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/66.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Figure 4.1
![Page 67: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/67.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 68: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/68.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 69: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/69.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.1
![Page 70: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/70.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Dimensions in mm (unless otherwise stated)
![Page 71: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/71.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 72: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/72.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO Manufacture Type Connections Dimensions
![Page 73: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/73.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
size Location Thread l x w x h
![Page 74: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/74.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Parker 19704
![Page 75: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/75.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 Herion 25381.15 side G 1/4" 110 x 48 x 32
![Page 76: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/76.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren M/P 19125
![Page 77: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/77.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Parker 29704
![Page 78: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/78.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 Herion 25382.15 side G 3/8" 124 x 57 x 40
![Page 79: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/79.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren M/P 19132
![Page 80: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/80.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Parker 39704
![Page 81: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/81.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 Herion 25383.15 side G 1/2" 149 x 71 x 32
![Page 82: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/82.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren M/P 19138
![Page 83: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/83.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Parker PS. 1456 213 x 94 x 53
![Page 84: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/84.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 Herion 25384.15 side G 3/8" 186 x 85 x 42
![Page 85: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/85.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren M/P 19144 186 x 85 x 42
![Page 86: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/86.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 87: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/87.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
G thread according ISO 228-1.
![Page 88: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/88.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 89: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/89.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 90: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/90.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.3. Ganged sub plates ISO 1 and 2
![Page 91: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/91.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Figure 4.2
![Page 92: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/92.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 93: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/93.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.2
![Page 94: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/94.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Dimensions in mm (unless otherwise stated)
![Page 95: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/95.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 96: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/96.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO Loc. a b c d 1 2 3 4 5 Type Man..
![Page 97: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/97.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
patt.
![Page 98: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/98.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 and 4 Ganged End plate
![Page 99: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/99.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
sub plate
![Page 100: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/100.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 both sides 38 43 100 63 G 3/8" G 3/8" G 3/8" G 3/8" G 3/8" EAXt502-1- EAXT502- SMC
![Page 101: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/101.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
10AX 2RL-A
![Page 102: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/102.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 both sides 40 56 142 805 G 1/2" G 1/2" G 1/2" G 1/2" G 1/2" EAXT512-1- EAXT512- SMC
![Page 103: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/103.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2A 2RL-A
![Page 104: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/104.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 105: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/105.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
G thread according ISO 228-1.
![Page 106: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/106.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 107: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/107.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 108: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/108.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.4. Ganged sub plates ISO 3 and 4
![Page 109: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/109.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Figure 4.3
![Page 110: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/110.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 111: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/111.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.3
![Page 112: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/112.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Dimensions in mm (unless otherwise stated)
![Page 113: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/113.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 114: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/114.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO- Port a b c d 1 2 3 4 5 Type Man.
![Page 115: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/115.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
patt.
![Page 116: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/116.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 and Ganged End plate
![Page 117: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/117.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 sub plate
![Page 118: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/118.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 zij 27 72 176 68 G 1" G 3/4" G 1" G 3/4" G 1" 2523320000 2153300000 Herion
![Page 119: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/119.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 zij 32 71 190 131,5 G 1" G 3/4" G 1" G 3/4" G 1" 39903 39907 Parker
![Page 120: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/120.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 zij 25 84 230 82 G 1" G 3/4" G 1" G 3/4" G 1" PS1444C PS1437 Parker
![Page 121: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/121.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 122: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/122.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
G thread according ISO 228-1.
![Page 123: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/123.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 124: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/124.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 125: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/125.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.1.5. Cover plate
![Page 126: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/126.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Figure 4.4
![Page 127: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/127.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 128: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/128.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.4
![Page 129: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/129.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO pattern Manufacture and type
![Page 130: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/130.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Parker SMC Herion Norgren
![Page 131: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/131.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 9121-5902-51 EAXT502-9A 0557673 CQM/221/52/3/2/3
![Page 132: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/132.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 PS1267 EAXT512-9A 0557734 CQM/222/53/3/2/3
![Page 133: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/133.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 PS1364 0557674 CQM/223/54/3/2/3
![Page 134: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/134.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 PS1479 0558456 CQM/224/56/3/2/3
![Page 135: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/135.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 136: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/136.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 137: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/137.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2. Directional control valves according ISO 5599-1, size 1 - 4
![Page 138: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/138.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2.1. Scope and application
![Page 139: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/139.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Directional control valves for pneumatics have a mounting face according
![Page 140: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/140.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO 5599-1. The valves are equipped with Cnomo pilots and plugs according ISO 4400 (3
![Page 141: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/141.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
poles with earth contact, 24 VAC, indicator LED).
![Page 142: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/142.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Plugs are also available integrated with cable.
![Page 143: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/143.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
These values are for general applications.
![Page 144: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/144.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Maximum pressure: 10 bar.
![Page 145: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/145.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2.2. Symbols
![Page 146: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/146.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 147: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/147.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2.3. Technical data
![Page 148: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/148.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Maximum pressure : 10 bar
![Page 149: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/149.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Minimal pressure : 2,5 bar
![Page 150: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/150.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Allowable capacity : size 1 - 880 l/min. (P=1 bar, P1=6 bar)
![Page 151: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/151.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
size 2 - 1640 l/min. (P=1 bar, P1=6 bar)
![Page 152: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/152.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
size 3 - 3270 l/min. (P=1 bar, P1=6 bar)
![Page 153: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/153.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
size 4 - 4910 l/min. (P=1 bar, P1=6 bar)
![Page 154: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/154.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Medium : filtered and dried air, lubricated or non lubricated
![Page 155: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/155.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Control : Solenoids 24 V=, max. 10 Watt
![Page 156: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/156.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Valve plug : Solenoids equipped with plug with red indication LED
![Page 157: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/157.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
(type Hirschman: GDME 2011 + screw 3N-7 + print +
![Page 158: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/158.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
GDME-LED 24 or Murrel elektronik plug + 5 mtr. cable,
![Page 159: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/159.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
type 3124239)
![Page 160: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/160.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Emergency manual : by means of spring return push button
![Page 161: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/161.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
control
![Page 162: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/162.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Seal : flexible seal
![Page 163: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/163.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 164: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/164.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 165: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/165.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.2.4. Manufactures and types
![Page 166: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/166.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.5
![Page 167: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/167.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Size 1
![Page 168: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/168.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Symbol Manufacture Type
![Page 169: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/169.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 Parker 19414 NTF + plug
![Page 170: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/170.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2531268.0154 + plug
![Page 171: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/171.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 Parker 19424 NTF + plug
![Page 172: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/172.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2531268.0154 + plug
![Page 173: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/173.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 Parker 19414XNTF + plug
![Page 174: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/174.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2531668.0154 + plug
![Page 175: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/175.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 Parker 19424YNTF + plug
![Page 176: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/176.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2531768.0154 + plugs
![Page 177: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/177.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 178: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/178.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.6
![Page 179: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/179.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Size 2
![Page 180: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/180.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Symbol Manufacture Type
![Page 181: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/181.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 Parker 29414 NTF + plug
![Page 182: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/182.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2532268.0154 + plug
![Page 183: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/183.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22253/172/N/24 V= + plug
![Page 184: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/184.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 Parker 29424 NTF + plugs
![Page 185: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/185.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2532568.0154 + plugs
![Page 186: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/186.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22253/123/N/24 V= + plugs
![Page 187: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/187.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 Parker 29424XNTF + plugs
![Page 188: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/188.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2532668.0154 + plugs
![Page 189: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/189.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22253/6123/N/24 V= + plugs
![Page 190: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/190.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 Parker 19424YNTF + plugs
![Page 191: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/191.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2531768.0154 + plugs
![Page 192: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/192.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22263/6123/N/24 V= + plugs
![Page 193: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/193.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 194: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/194.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 195: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/195.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.7
![Page 196: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/196.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Size 3
![Page 197: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/197.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Symbol Manufacture Type
![Page 198: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/198.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 Parker 39414 NTF + plug
![Page 199: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/199.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2533268.0154 + plug
![Page 200: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/200.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22353/172/N/24 V= + plug
![Page 201: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/201.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 Parker 39424 NTF + plugs
![Page 202: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/202.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2533568.0154 + plugs
![Page 203: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/203.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22354/123/N/24 V= + plugs
![Page 204: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/204.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 Parker 39424XNTF + plugs
![Page 205: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/205.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2533668.0154 + plugs
![Page 206: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/206.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22354/6123/N/24 V= + plugs
![Page 207: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/207.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 Parker 39424YNTF + plugs
![Page 208: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/208.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Herion 2533768.0154 + plugs
![Page 209: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/209.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22364/6123/N/24 V= + plugs
![Page 210: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/210.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 211: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/211.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.8
![Page 212: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/212.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Size 4
![Page 213: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/213.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Symbol Manufacture Type
![Page 214: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/214.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 Herion 2531268.0154 + plug
![Page 215: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/215.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22456/172/N/24 V= + plug
![Page 216: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/216.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 Herion 2534568.0154 + plugs
![Page 217: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/217.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22456/123/N/24 V= + plugs
![Page 218: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/218.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 Herion 2534668.0154 + plugs
![Page 219: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/219.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22456/6123/N/24 V= + plugs
![Page 220: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/220.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 Herion 2534768.0154 + plugs
![Page 221: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/221.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Norgren UM/22466/123/N/24 V= + plugs
![Page 222: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/222.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 223: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/223.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 224: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/224.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3. Proportional pressure control valves
![Page 225: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/225.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3.1. Scope and application
![Page 226: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/226.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Proportional pressure control valves will be used at applications where an adjustable force
![Page 227: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/227.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
is required.
![Page 228: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/228.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
The pilot signal is electrical. The valve has a closed circuit built in pressure control.
![Page 229: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/229.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3.2. Symbol according NEN 3348 (ISO 1219-1)
![Page 230: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/230.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 231: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/231.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3.3. Technical data manufacturer: Mannesmann, Rexroth
![Page 232: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/232.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Precision pressure control valve, proportional
![Page 233: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/233.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Maximum supply pressure 8 bar
![Page 234: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/234.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Maximum flow 600 l/min (P=1 bar, P1 = 7 bar)
![Page 235: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/235.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Connection BSP 1/4"
![Page 236: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/236.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Controlled pressure 0,1 - 6 bar
![Page 237: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/237.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Repeatability and hysteresis 0,4 bar
![Page 238: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/238.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Power supply 24 V=
![Page 239: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/239.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Current control 4-20 mA Type: 561.010.215.0
![Page 240: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/240.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Voltage control 0-10 V Type: 561.010.202.0.
![Page 241: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/241.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.3.4. Technical data manufacturer: Herion
![Page 242: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/242.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Proportional pressure control valve with integrated electronic pressure control
![Page 243: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/243.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Maximum supply pressure 10 bar
![Page 244: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/244.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Can be mounted at a ISO 5599 mounting face size 1, 2 or 3 by means of an adapter plate.
![Page 245: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/245.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Repeatability and hysteresis 0,05 bar
![Page 246: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/246.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Power supply 24 V=.
![Page 247: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/247.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 248: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/248.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.9
![Page 249: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/249.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO Control signal
![Page 250: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/250.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
pattern 4 - 20 mA 0 - 10 V
![Page 251: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/251.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 4091112 4091110
![Page 252: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/252.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 4091312 4091310
![Page 253: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/253.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 4091412 4091410
![Page 254: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/254.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 255: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/255.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4. Sandwich valves according ISO 5599
![Page 256: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/256.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.1. Scope and application
![Page 257: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/257.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Sandwich valves are used mainly for limiting of pressures and flows. Mounting face
![Page 258: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/258.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
according ISO 5599. Max. pressure 10 bar.
![Page 259: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/259.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.2. Throttle valves, sandwich type
![Page 260: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/260.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Throttling in connection 3 and 5.
![Page 261: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/261.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 262: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/262.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.3. Manufactures and sizes
![Page 263: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/263.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Parker Herion Norgren
![Page 264: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/264.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO-size Ordering number Ordering number Ordering number
![Page 265: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/265.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 19501 0557618 CQM 22152/3/26
![Page 266: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/266.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 29501 0557619 CQM 22153/3/26
![Page 267: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/267.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 39501 0557620 CQM 22154/3/26
![Page 268: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/268.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 N 91262 0558357 CQM 22156/3/26
![Page 269: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/269.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 270: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/270.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 271: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/271.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4. Reducing valve, sandwich type (ISO)
![Page 272: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/272.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4.art.a. Reducer function in port 1
![Page 273: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/273.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture
![Page 274: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/274.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO size Parker Herion
![Page 275: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/275.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 19/N91374-1 2538130 (button left)
![Page 276: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/276.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2538133 (button right)
![Page 277: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/277.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 29/N91375-1
![Page 278: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/278.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 39/N91376-1 2538330 (button left)
![Page 279: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/279.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2538333 (button right)
![Page 280: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/280.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 49/N91377-1
![Page 281: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/281.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4.art.b. Reducer function in port 2
![Page 282: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/282.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture
![Page 283: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/283.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO size Parker Norgren
![Page 284: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/284.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 19/N91374-2 FP 7054
![Page 285: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/285.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 29/N91375-2
![Page 286: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/286.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 39/N91376-2 FP 7074
![Page 287: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/287.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 49/N91377-2
![Page 288: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/288.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4.art.c. Reducer function in port 4
![Page 289: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/289.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture
![Page 290: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/290.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO size Parker Norgren
![Page 291: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/291.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 19/N91374-4 FP 7055
![Page 292: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/292.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 29/N91375-4
![Page 293: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/293.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 39/N91376-4 FP 7075
![Page 294: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/294.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 49/N91377-4
![Page 295: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/295.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.4.4.art.d. Reducer function in port 2 and 4
![Page 296: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/296.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture
![Page 297: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/297.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO size Parker
![Page 298: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/298.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1 19/N91374-2/4
![Page 299: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/299.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2 29/N91375-2/4
![Page 300: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/300.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3 39/N91376-2/4
![Page 301: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/301.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4 49/N91377-2/4
![Page 302: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/302.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 303: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/303.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 304: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/304.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5. In line valves
![Page 305: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/305.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.1. Scope and application
![Page 306: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/306.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
In line valves for sub plate mounting are preferred.
![Page 307: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/307.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
For special functions are large size, in line mounting is some inevitable.
![Page 308: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/308.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 309: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/309.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
The following components with female threaded connection are to be applied:
![Page 310: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/310.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 311: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/311.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
− check valves (non return valves)
![Page 312: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/312.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
− throttle/non return valves
![Page 313: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/313.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
− shuttle valves
![Page 314: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/314.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
− quick exhaust valves.
![Page 315: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/315.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.2. Symbols according NEN 3348 (ISO 1219-1)
![Page 316: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/316.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 317: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/317.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.3. Check valves
![Page 318: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/318.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Figure 4.5
![Page 319: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/319.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture: Norgren, max. pressure 17 bar, opening pressure 0,5 bar
![Page 320: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/320.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 321: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/321.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Type number Connection inside
![Page 322: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/322.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/520 G 1/8"
![Page 323: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/323.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/521 G 1/4"
![Page 324: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/324.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/522 G 1/2"
![Page 325: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/325.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/523 G 3/4"
![Page 326: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/326.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/524 G 1"
![Page 327: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/327.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 328: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/328.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 329: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/329.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.4. Throttle non return valve, female threaded
![Page 330: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/330.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture: Norgren, max. pressure 17,5 bar, opening pressure 1 bar
![Page 331: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/331.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 332: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/332.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Type number NW Connection"
![Page 333: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/333.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/836 G 1/8"
![Page 334: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/334.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
M/837 G 1/4"
![Page 335: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/335.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
M/839 G 1/2"
![Page 336: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/336.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
M/840 G 3/4"
![Page 337: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/337.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
M/855 G 1"
![Page 338: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/338.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 339: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/339.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.10
![Page 340: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/340.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture: Ross, max. pressure 10 bar, opening pressure 0,3 bar
![Page 341: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/341.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 342: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/342.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Type number Connection"
![Page 343: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/343.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
New Old
![Page 344: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/344.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 2007 D 515 M 1 G 1/8"
![Page 345: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/345.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 3007 D 515 M 1 G 1/4"
![Page 346: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/346.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 4007 D 515 M 1 G 1/2"
![Page 347: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/347.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 5007 D 515 M 1 G 3/4"
![Page 348: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/348.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 6007 D 515 M 1 G 1"
![Page 349: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/349.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 7007 D 515 M 1 G 1 1/4"
![Page 350: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/350.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 8007 D 515 M 1 G 1 1/2"
![Page 351: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/351.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 9007 D 515 M 1 G 2"
![Page 352: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/352.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.5. Shuttle valves, female threaded
![Page 353: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/353.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.11
![Page 354: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/354.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture: Norgren, max. pressure 10 bar, opening pressure 0,7 bar
![Page 355: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/355.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 356: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/356.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Type number NW Connection G
![Page 357: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/357.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/575 1/8"
![Page 358: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/358.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/592 1/4"
![Page 359: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/359.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 360: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/360.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.12
![Page 361: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/361.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture: Ross, max. pressure 10 bar, opening pressure 0,3 bar
![Page 362: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/362.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 363: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/363.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Type number NW Connection G
![Page 364: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/364.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 2003 1/4"
![Page 365: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/365.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 366: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/366.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 367: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/367.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.5.6. Quick exhaust valves, female threaded
![Page 368: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/368.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.13
![Page 369: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/369.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture: Norgren, max. pressure 10 bar, opening pressure 0,7 bar
![Page 370: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/370.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 371: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/371.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Type number NW Connection
![Page 372: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/372.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
G 1 - 2 - 3
![Page 373: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/373.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/510 1/4" - 3/8" - 3/4"
![Page 374: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/374.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
S/511 1/2" - 3/4" - 3/4"
![Page 375: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/375.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 376: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/376.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.14
![Page 377: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/377.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture: Ross, max. pressure 10 bar, opening pressure 0,3 bar
![Page 378: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/378.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 379: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/379.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Type number NW Connection G
![Page 380: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/380.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 3005 16 3/8" - 3/8" - 1/2"
![Page 381: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/381.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 4005 16 1/2" - 1/2" - 1/2"
![Page 382: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/382.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 5005 18 3/4" - 3/4" - 1"
![Page 383: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/383.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 1968 A 6005 18 1" - 1" - 1"
![Page 384: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/384.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 385: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/385.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 386: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/386.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.6. "Slow start" valve
![Page 387: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/387.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.6.1. Scope and application
![Page 388: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/388.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
In certain circuits, especially with large flows, the switch-on of supply pressure will cause
![Page 389: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/389.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
undesired movements.
![Page 390: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/390.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
With a slow start valve, the pressurisation will be decelerated.
![Page 391: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/391.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 392: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/392.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Note:
![Page 393: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/393.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
A “slow start” valve is no safety valve!
![Page 394: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/394.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.6.2. Symbol according NEN 3348 (ISO 1219-1)
![Page 395: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/395.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 396: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/396.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.6.3. Technical data
![Page 397: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/397.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.15
![Page 398: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/398.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture: Ross, max. pressure 10 bar
![Page 399: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/399.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 400: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/400.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Type number NW Connection G
![Page 401: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/401.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 2781 A 4017 13 1/2"
![Page 402: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/402.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 2781 A 6017 21 1"
![Page 403: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/403.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
D 2781 A 8017 38 1 1/2"
![Page 404: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/404.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 405: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/405.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Manufacture Norgren:
![Page 406: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/406.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
In the line of FRL units from Norgren is also a slow start valve available. See Technical
![Page 407: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/407.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Directive R1 41 01 04E, paragraph 4.3.1.
![Page 408: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/408.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 409: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/409.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 410: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/410.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.7. Shut off valves / ball valves PN 16
![Page 411: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/411.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.7.1. Ball valves with male thread ends
![Page 412: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/412.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Figure 4.6
![Page 413: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/413.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 414: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/414.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 415: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/415.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.16
![Page 416: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/416.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
DN Connection D Building length according
![Page 417: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/417.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
DIN ISO 228/1 DIN 3202 M3
![Page 418: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/418.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
6 G 1/4" 50
![Page 419: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/419.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
10 G 3/8" 60
![Page 420: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/420.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
16 G 1/2" 75
![Page 421: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/421.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
20 G 3/4" 80
![Page 422: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/422.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
25 G 1" 90
![Page 423: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/423.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
32 G 1 1/4" 110
![Page 424: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/424.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
40 G 1 1/2" 120
![Page 425: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/425.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 426: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/426.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Material:
![Page 427: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/427.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Housing: Messing, nickled
![Page 428: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/428.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Ball: Messing, chromed
![Page 429: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/429.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Seal: Teflon, Perbunan.
![Page 430: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/430.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.7.2. Ball valves for flange mounting
![Page 431: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/431.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Figure 4.7
![Page 432: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/432.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 433: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/433.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 434: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/434.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.17
![Page 435: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/435.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
DN Building length according DIN 3202
![Page 436: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/436.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
L Shape
![Page 437: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/437.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
40 140 F4
![Page 438: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/438.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
50 150 F4
![Page 439: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/439.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
65 170 F4
![Page 440: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/440.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
80 180 F4
![Page 441: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/441.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 442: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/442.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Material:
![Page 443: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/443.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Body: C22/GS-C25 according NEN-EN 10083-196
![Page 444: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/444.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Ball: X5CrNiMo 17-12-2 (AISI 316) according NEN-EN 10088
![Page 445: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/445.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Seals: ball-PTFE, spindle-FPM.
![Page 446: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/446.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 447: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/447.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Construction:
![Page 448: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/448.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Floating ball
![Page 449: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/449.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
90° shift with indicator
![Page 450: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/450.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
including handle
![Page 451: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/451.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 452: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/452.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Flanges drilled according DIN 2501
![Page 453: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/453.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Building length according DIN 3202 F4/F5
![Page 454: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/454.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Testing according DIN 3230, Teil 5 en 6
![Page 455: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/455.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Marking according EN 19.
![Page 456: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/456.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.7.3. Three-way ball valves, male threaded
![Page 457: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/457.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Figure 4.8
![Page 458: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/458.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 459: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/459.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 460: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/460.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 461: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/461.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Scheme 4.18
![Page 462: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/462.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Dimensions in mm
![Page 463: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/463.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 464: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/464.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
DN Connection D DIN ISO 228/1 Building length L
![Page 465: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/465.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
6 G 1/4" 82
![Page 466: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/466.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
10 G 3/8" 92
![Page 467: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/467.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
16 G 1/2" 113
![Page 468: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/468.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
20 G 3/4" 129
![Page 469: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/469.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
25 G 1" 151
![Page 470: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/470.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
32 G 1 1/4" 172
![Page 471: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/471.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
40 G 1 1/2" 206
![Page 472: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/472.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 473: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/473.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Material:
![Page 474: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/474.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Body: Steel, GGG
![Page 475: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/475.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Ball: Stainless steel, brass GGG chromated
![Page 476: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/476.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Seals: ball-Teflon, spindle-Perbunan.
![Page 477: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/477.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 478: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/478.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 479: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/479.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.8. References
![Page 480: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/480.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
In this Technical Directive reference is made to
![Page 481: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/481.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 482: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/482.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
NEN 3348 (= ISO 1219-1)
![Page 483: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/483.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 484: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/484.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
EN
![Page 485: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/485.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
19
![Page 486: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/486.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
10083
![Page 487: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/487.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
10088
![Page 488: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/488.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 489: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/489.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
ISO
![Page 490: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/490.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
228-1
![Page 491: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/491.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
1219-1
![Page 492: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/492.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4400
![Page 493: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/493.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
5599
![Page 494: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/494.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 495: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/495.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
DIN
![Page 496: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/496.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
2501
![Page 497: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/497.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3202
![Page 498: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/498.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
3230
![Page 499: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/499.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 500: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/500.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Technical Directive R1 41 01 04E.
![Page 501: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/501.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 502: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/502.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 503: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/503.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
4.9. Explanation
![Page 504: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/504.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Version 1.0:
![Page 505: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/505.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
none.
![Page 506: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/506.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
![Page 507: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/507.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
Version 1.1:
![Page 508: R1 41 01 04 Technical Directive](https://reader035.fdocuments.in/reader035/viewer/2022081419/62a1084955ab2360765e02b7/html5/thumbnails/508.jpg)
R1 41 01 04
Pneumatics directive for suppliers, erection
companies, managers and users
Part 4: Selection energy distribution (valves)
logo has changed.