R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead...

39
R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead 0 5 Elastic Scattering Parity Violating Asymmetry Spokespersons Kent Paschke, Paul Souder, Krishna Kumar, Guido Urciuoli, Robert Michaels (presenting) PREX-I Results 2010 Run Approved PREX-II Proposal Future : PREX-N ? (N = III, IV, V …) PAVI – 11 Conferenc e

Transcript of R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead...

Page 1: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Lead (208Pb) Radius Experiment : PREX

E = 1 GeV, electrons on lead

05

Elastic Scattering Parity Violating Asymmetry

Spokespersons

Kent Paschke, Paul Souder, Krishna Kumar,

Guido Urciuoli, Robert Michaels (presenting)

• PREX-I Results 2010 Run

• Approved PREX-II Proposal

• Future : PREX-N ? (N = III, IV, V …)

PAVI – 11Conference

Page 2: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Z0 of weak interaction : sees the neutrons proton neutron

Electric charge 1 0

Weak charge 0.08 1

Neutron form factor

)()(4

1)( 0

32 rqrjrdQF NN

Parity Violating Asymmetry

)(

)(sin41

22 2

22

2

QF

QFQGA

P

NW

F

0

T.W. Donnelly, J. Dubach, I. Sick

C.J. Horowitz

Nucl. Phys. A 503, 589, 1989

C. J. Horowitz, S. J. Pollock, P. A. Souder, R. Michaels Phys. Rev. C 63, 025501, 2001

Page 3: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Hall A at Jefferson Lab

Hall A

Page 4: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Measured Asymmetry

Weak Density at one Q2

Neutron Density at one Q2

Correct for CoulombDistortions

Small Corrections forG

nE G

sE MEC

Assume Surface Thickness Good to 25% (MFT)

Atomic Parity Violation

Mean Field & Other

Models

Neutron

Stars

R n

PREX Physics Output

Slide adapted from C. Horowitz

Page 5: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

ZN

Nuclear Structure: Neutron density is a fundamental observable that remains elusive.

Reflects poor understanding of symmetry energy of nuclear matter = the energy cost of

xn

)21()()2/1,(),( 2xnSxnExnE

n.m. density

ratio proton/neutrons

• Slope unconstrained by data

• Adding R from Pb will eliminate the

dispersion in plot.

N208

Slide adapted from J. Piekarewicz

5

Page 6: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Skx-s15Thanks, Alex Brown

PREX Workshop 2008

E/N

N

Page 7: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Skx-s20Thanks, Alex Brown

PREX Workshop 2008

E/N

N

Page 8: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Skx-s25Thanks, Alex Brown

PREX Workshop 2008

E/N

N

8

Page 9: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Application: Atomic Parity Violation• Low Q test of Standard Model

• Needs RN (or APV measures RN )

2

0

Isotope Chain Experiments e.g. Berkeley Yb

9

APV

rdrZrNG

H eePWNF

PNC35/2 )()sin41()(

22

Page 10: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

PREX & Neutron Stars

pn RR

Crab Pulsar

C.J. Horowitz, J. Piekarewicz

RN calibrates equation of state (pressure vs density) of Neutron Rich Matter

Combine PREX RN with Observed Neutron Star Radii

Some Neutron Stars seem too cold

Strange star ? Quark Star ?

Explained by Cooling by neutrino emission (URCA process) ?

0.2 fm URCA probable, else not

Phase Transition to “Exotic” Core ?

Fig from: Dany Page. J.M. Lattimer & M.

Prakash, Science 304 (2004) 536.

Page 11: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

PREX Overview

CEBAF

Hall AJLAB

Pol. Source

Lead Foil Target

Spectometers

Parity: “The entire lab is the experiment”

Page 12: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Slug # ( ~ 1 day)

Units: microns

RLhelicityforXX LR ,

Parity Quality Beam ! ( why we love Jlab ! )

Helicity – Correlated Position Differences

< ~ 3 nmAverage with signs = what exp’t feels

Points: Not sign corrected

Page 13: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

• Two Wien Spin Manipulators in series• Solenoid rotates spin +/-90 degrees (spin rotation as B but focus as B2).

Flips spin without moving the beam !

Double Wien FilterCrossed E & B fields to rotate the spin

Electron Beam SPIN

(NEW for PREX)

Joe Grames, et. al.

13

Page 14: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Hall A Compton Upgrade

with Green Laser

Sirish Nanda, et. al. (Megan Friend’s talk)

1 % Polarimetry

at 1 GeV

Page 15: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Hall A Moller Upgrade

Superconducting Magnet from Hall C

Saturated Iron Foil Targets

< 1 % Polarimetry

Magnet and Target

DAQ Upgrade (FADC)

Sasha Glamazdin, et.al. (talk Thurs)

Page 16: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Hall A High Resolution Spectrometers

Elastic

Inelasticdetector

Dipole

Quads

target

DETECTOR footprint

2.6 MeV

Pure, Thin 208 Pb Target

Scattered Electron’s Momentum (GeV/c)

• Resolve Elastic Scattering

• Discriminate Excited States

16

Page 17: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Diamond LEAD

• Three bays

• Lead (0.5 mm) sandwiched by diamond (0.15 mm)

• Liquid He cooling (30 Watts)

Lead / Diamond Target

Page 18: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Performance of Lead / Diamond Targets

Last 4 days at 70 uA

Targets with thin diamond backing (4.5 % background) degraded fastest.

Thick diamond (8%) ran well and did not melt at 70 uA.

meltedmelted

NOT melted

Solution: Run with 10 targets.

Page 19: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

y

z

xS

k

+ -

AT > 0 means

)'( eeeT kkSA

Beam-Normal Asymmetry in elastic electron scatteringi.e. spin transverse to scattering plane

Possible systematic if small transverse spin component

New results PREX

ppmAC T 35.036.052.6:12

ppmAPb T 36.019.013.0:208

• Small AT for 208Pb is a big (but pleasant) surprise. • AT for 12C qualitatively consistent with 4He and available calculations (1) Afanasev ; (2) Gorchtein & Horowitz

Pre

limin

ary !

Publicatio

n in

prepara

tion

19

Page 20: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Error Source Absolute (ppm)

Relative ( % )

Polarization (1) 0.0071 1.1

Beam Asymmetries (2) 0.0072 1.1

Detector Linearity 0.0071 1.1

BCM Linearity 0.0010 0.2

Rescattering 0.0001 0

Transverse Polarization 0.0012 0.2

Q2 (1) 0.0028 0.4

Target Thickness 0.0005 0.112C Asymmetry (2) 0.0025 0.4

Inelastic States 0 0

TOTAL 0.0130 2.0

Systematic Errors

(1) Normalization Correction applied

(2) Nonzero correction (the rest assumed zero)

)(0130.0)(0604.0

6571.0

syststat

ppmA

PREX-I Result

Statistics limited ( 9% )

Systematic error goal achieved ! (2%)

20

Page 21: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

PREX Asymmetry (Pe x A)

ppm

Slug ~ 1 day

Page 22: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Neutron Skin = RN - RP = 0.31 + 0.15 - 0.17 fm

Establishing a neutron skin at ~90 % CL

Asymmetry leads to RN

fig from C.J. Horowitz

PREX data

Preliminary: Awaiting the “final” acceptance function: )(

*

*

Page 23: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

PREX-I Result, cont.

)(0130.0)(0604.0

6571.0

syststat

ppmA

theory: P. Ring

Atomic Number, A

r N -

rP

(fm

)

DATA

DATA

A physics letter is in preparation for publication.

rN = rP

Neutron Skin = RN - RP = 0.31 + 0.15 - 0.17 fm

Preliminary: Awaiting the “final” acceptance function

23

Page 24: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

PREX-II Approved by PAC (Aug 2011)

“A” Rating 35 days run in 2013 / 2014

Page 25: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Collimators

Septum Magnet

target

HRS-L

Q1

HRS-R

Q1

PREX Region After Target

Former O-Ring location which failed & caused time loss during PREX-I

PREX-II to use all-metal seals

Tungsten Collimator & Shielding

Improvements for PREX-II

Page 26: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Geant 4 Radiation Calculations

PREX-II shielding strategies

J. Mammei, L. Zana

Number of Neutrons per incident Electron

Strategy

• Tungsten ( W ) plug

• Shield the W

• x 10 reduction in 0.2 to 10 MeV neutrons

00 37.0

0 - 1 MeV

Energy (MeV)

Energy (MeV)

Energy (MeV)

--- PREX-I--- PREX-II, no shield--- PREX-II, shielded

1 - 10 MeV

10 - 1200 MeV

beamline

shielding

scattering chamber

26

Page 27: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Other Nuclei ?

Shape Dependence ?RN

RN

Surface thickness

Surface thickness

arXiv:1010.3246  [nucl-th]

Parity Violating Electron Scattering Measurements of Neutron Densities Shufang Ban, C.J. Horowitz, R. Michaels

Page 28: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Possible Future PREX Program ?

Nucleus E (GeV) dRN / RN comment

208Pb 1 1 % PREX-II (approved)

48Ca 2.2 (1-pass) 0.4 % natural 12 GeV exp’t

48Ca 2.6 2 % surface thickness

40Ca 2.2 (1-pass) 0.6 % basic check of theory

tin isotope 1.8 0.6 % apply to heavy ion

tin isotope 2.6 1.6 % surface thickness

Each point 30 days stat. error only

Not yet proposed.Just a “what if ?”

arXiv:1010.3246  [nucl-th] Shufang Ban, C.J. Horowitz, R. Michaels

Page 29: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Future in Hall A at JLab

2011 2012 2013 2014 2015 2016 2017 2018

g2p/GEp 12 mo. Shutdown

no promised beam

Early Experiments

Commissioning SuperBigbite

Moller

SOLID

Beam 1st to Hall A

PREX – II ?

$

$$$

$$$$

Page 30: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

PREX : Summary • Fundamental Nuclear Physics with

many applications

• PREX-I achieved a 9% stat. error in Asymmetry (original goal : 3 %)

• Systematic Error Goals Achieved !!

• Significant time-losses due to O-Ring problem and radiation damage

• PREX-II approved (runs in 2013 or 2014 we hope )

Page 31: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Extra Slides

Page 32: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

How to Measure

Neutron Distributions, Symmetry Energy • Proton-Nucleus Elastic• Pion, alpha, d Scattering• Pion Photoproduction• Heavy ion collisions• Rare Isotopes (dripline)

• Magnetic scattering

• PREX (weak interaction)

• Theory MFT fit mostly by data other than neutron densities

Involve strong probes

Most spins couple to zero.

Page 33: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

)()()(ˆ 5 rArVrV

)(

)(sin41

22 2

22

2

QF

QFQG

d

d

d

d

d

d

d

d

AP

NW

F

LR

LR

neutron weak charge >> proton weak charge

is small, best observed by parity violation

||)()(/

//3 rrrZrdrV )()()sin41(22

)( 2 rNrZG

rA NPWF

22 |)(| QFd

d

d

dP

Mott

)()(4

1)( 0

32 rqrjrdQF PP )()(

4

1)( 0

32 rqrjrdQF NN

Electron - Nucleus Potential

electromagnetic axial

Neutron form factor

Parity Violating Asymmetry

)(rA

1sin41 2 W

Proton form factor

0

Pb is spin 0208

Page 34: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Corrections to the Asymmetry are Mostly Negligible

• Coulomb Distortions ~20% = the biggest correction.

• Transverse Asymmetry (to be measured)

• Strangeness

• Electric Form Factor of Neutron

• Parity Admixtures

• Dispersion Corrections

• Meson Exchange Currents

• Shape Dependence

• Isospin Corrections

• Radiative Corrections

• Excited States

• Target Impurities

Horowitz, et.al. PRC 63 025501

Page 35: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

PAVI 09

Optimum Kinematics for Lead Parity: E = 1 GeV if <A> = 0.5 ppm. Accuracy in Asy 3%

n

Fig. of merit

Min. error in R

maximize:

1 month run

1% in R

n

(2 months x 100 uA 0.5% if no systematics)

5

Page 36: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

/)( AA

Pull Plot (example)

PREX Data

Page 37: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Liquid/Solid Transition Density

• Thicker neutron skin in Pb means energy rises rapidly with density Quickly favors uniform phase.

• Thick skin in Pb low transition density in star.

FP

TM1Solid

Liquid

Neutron Star Crust vs Pb Neutron Skin

208Pb

Neutron Star

C.J. Horowitz, J. Piekarawicz

Page 38: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

Backgrounds that might re-

scatter into the detector ?

Run magnets down: measure inelastic region

Run magnets up : measure probability to rescatter

No inelastics observed on top of radiative tail. Small systematic for tail.

Detector cutoff

Page 39: R. Michaels, Jlab PAVI-11 Lead ( 208 Pb) Radius Experiment : PREX E = 1 GeV, electrons on lead Elastic Scattering Parity Violating Asymmetry Spokespersons.

R. Michaels, Jlab PAVI-11

.../ 3/12

4

AaA

ZNaa

A

Esv

)1(

PREX: pins down the symmetry energy (1 parameter)

( R.J. Furnstahl )

energy cost for unequal # protons & neutrons

PREX

PREX error bar

Pb208 Actually, it’s the

density dependence of a4 that we pin down.