11t Heated Mud Skip Quotation Specification: Heated Mud Skip Type: 11T Mud Skip Maximum Payload: 8900 Kg Approvals: DNV 2.7-1 (2013) MGW: 11000 Kg EN 12079 (2006) External Dimensions: 2202mm x 1842mm x 1672mm high Capacity: 3450 liters / 910 gallons Tare: 2100 Kg Category Specification Details (if required) Frame Design and Temp: -40C EN 10219 S355 K3/K4 on primary structure, EN 10025 S355 K4 on pad eyes EN 10219 S235 JR on secondary structure Emptying Hatch: As per details 1 x Fully removable top section for complete emptying 2 x Aluminium lid Chains (x 4) included for 'open' position NDT: As per details MPI on frame as per DNV 2.7-1 requirements Test Requirements: As per details As per DNV 2.7-1: Test consists of a 4- point, 2-point Lift Test, Drop Test and witnessed by DNV. Leak check on steam channels (2 Bar, with air or water) in house. Inlet/Outlet Fittings: Standard 2 x 6" BSP Nipples c/w Cap Vacuum Rated: 0.5 Bar Forkpockets: 4 - Way 4 Way, 328mm x 104mm (internal dimensions), 6mm Carbon Steel, 900mm and 1440mm between Centres Padeyes: Ø 29.5 mm hole for 8.5 tonne shackle 4 no. Ladders: As per details Cut-outs in outer protection skin for steps – these are in lieu of ladder requirements External Frame Finish: As per details Paint System – Standard 3 Coat Paint System Units are to be shot blasted to SA

Transcript of Quotation Specification: Heated Mud Skip Heated...11t Heated Mud Skip Quotation Specification:...

11t Heated Mud Skip

Quotation Specification: Heated Mud Skip

Type: 11T Mud Skip Maximum Payload: 8900 Kg

Approvals: DNV 2.7-1 (2013) MGW: 11000 Kg

EN 12079 (2006)

External Dimensions: 2202mm x 1842mm x 1672mm high

Capacity: 3450 liters / 910 gallons

Tare: 2100 Kg

Category Specification Details (if required)

Frame Design and Temp:

-40C EN 10219 S355 K3/K4 on primary structure, EN 10025 S355 K4 on pad eyes EN 10219 S235 JR on secondary structure

Emptying Hatch: As per details 1 x Fully removable top section for complete emptying 2 x Aluminium lid Chains (x 4) included for 'open' position

NDT: As per details MPI on frame as per DNV 2.7-1 requirements

Test Requirements: As per details As per DNV 2.7-1: Test consists of a 4- point, 2-point Lift Test, Drop Test and witnessed by DNV. Leak check on steam channels (2 Bar, with air or water) in house.

Inlet/Outlet Fittings: Standard 2 x 6" BSP Nipples c/w Cap

Vacuum Rated: 0.5 Bar

Forkpockets: 4 - Way 4 Way, 328mm x 104mm (internal dimensions), 6mm Carbon Steel, 900mm and 1440mm between Centres

Padeyes: Ø 29.5 mm hole for 8.5 tonne shackle

4 no.

Ladders: As per details Cut-outs in outer protection skin for steps – these are in lieu of ladder requirements

External Frame Finish: As per details Paint System – Standard 3 Coat Paint System Units are to be shot blasted to SA

Issue 1: 1/15

1.

2½ (50-75 microns) First Coat: Zinc Rich Epoxy – 50 microns Second Coat: High Build Intermediate – 100 microns Third Coat: Top Coat Epoxy Acrylic Finish – 50 microns Total DFT – 200 microns

Stencils: Standard Serial number stencil on roof/lid for identification by crane driver

Drain: Standard 2” Nipple c/w Cap

Swing Bolts:

Suretank Standard Special with Hexnuts. 12no. required for main lid

Issue 1: 1/15

2.

Product: Photographs

Issue 1: 1/15

3.

Product: GA Drawing

Issue 1: 1/15