QUIZ 1

6
QUIZ 1 JJ517 INSTRUMENTATION & CONTROL NAME :__________________________________________________________ MATRIX NO :__________________________________________________________ CLASS :________________________________________________________ __ TIME : 15 MINUTES CLO 1 – PLO 1 ANSWER ALL QUESTIONS 1. Define the term of instrumentation :__________________________________________________ __________ ___________________________________________________________________ _____________________ ___________________________________________________________________ _____________________ ( 2m) 2. Draw block diagram for the basic measurement system (3m) 3. Comparison between self generation and modulator types transducer

description

gy

Transcript of QUIZ 1

QUIZ 1JJ517 INSTRUMENTATION & CONTROLNAME :__________________________________________________________MATRIX NO :__________________________________________________________CLASS:__________________________________________________________TIME : 15 MINUTES CLO 1 PLO 1ANSWER ALL QUESTIONS1. Define the term of instrumentation :____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________ ( 2m)2. Draw block diagram for the basic measurement system

(3m)3. Comparison between self generation and modulator types transducer________________________________________________________________________________________________________________________________________________________________________________(2m)4. Give FOUR (4) the characteristic of transducer :a. __________________________________________________________________________________b. __________________________________________________________________________________c. __________________________________________________________________________________d. __________________________________________________________________________________ (4m)

5. Give the examples for signal adjustor technique for:a. Mechanical type:__________________________________________________b. Electrical type: ___________________________________________________ (2m)

6. Define the term of calibration :________________________________________________________________________________________________________________________________________________________________________________________________________________________________________________( 2m)7. Why need the calibration to be done:_____________________________________________________________________________________________________________________________________________________________________________________________________________________________________________( 2m)8. Give FOUR (4) aspect in the documentation for the Maintenance of Measurement System and the Calibration Procedures.a. __________________________________________________________________________________b. __________________________________________________________________________________c. __________________________________________________________________________________d. __________________________________________________________________________________( 4m)9. Give TWO (2) errors in instrumentation:a. __________________________________________________________________________________b. __________________________________________________________________________________( 2m)10. Define the term of accuracy :__________________________________________________________________________________________________________________________________________________________________________________________________________________________________________( 2m)

Answer Scheme

1. is defined as the art and science of measurement and control of process variables within a production, or manufacturing area 1+12. 1+1+13. Self generation Generate voltage or current by itself not need the external power supply compared to modulator which need power supply to be operated1+14. PrecisionSensitivityRangeStabilityLinearityMechanical factorCostResponse: ratio i/oHysterisisEach answer 1 mark Total 4 M5. a. lever or gear 1b. amplifier or adc or dac,16. calibration : process comparing and correction the output of instrument with standard value1 Need to be carry out as requirement and usage.17. avoid the instrument spoil Make sure instrument working within the specificationFor quality output 8 point 1 m Max 2 m8.Measurement Limit Statement Measurement LocationStatement on the standard usedCalibration ResultEach point 1 mark Total 4 mark9. ratio error static errordynamic errorpersonal errorrandom errorsystematic error user erroreach point 1 mark max 2 marks10. The extent to which the value indicated by a measurement system or element might be wrong. summation of all the possible errors that are likely to occur, as well as the accuracy to which the system or element has been calibrated. Accuracy is often expressed as a percentage of the full range output or full-scale deflection (f.s.d). Each point 1 mark Max 2 mark