Quidway S2700&S3700&S5700&S6700 V100R006C00SPC800 Upgrade Guide

57
Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches V100R006C00SPC800 Upgrade Guide Issue 01 Date 2011-09-30 HUAWEI TECHNOLOGIES CO., LTD.

Transcript of Quidway S2700&S3700&S5700&S6700 V100R006C00SPC800 Upgrade Guide

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches V100R006C00SPC800

    Upgrade Guide

    Issue 01

    Date 2011-09-30

    HUAWEI TECHNOLOGIES CO., LTD.

  • Copyright Huawei Technologies Co., Ltd. 2011. All rights reserved.

    No part of this document may be reproduced or transmitted in any form or by any means without prior written consent of Huawei Technologies Co., Ltd.

    Trademarks and Permissions

    and other Huawei trademarks are trademarks of Huawei Technologies Co., Ltd.

    All other trademarks and trade names mentioned in this document are the property of their respective holders.

    Notice

    The purchased products, services and features are stipulated by the contract made between Huawei and the customer. All or part of the products, services and features described in this document may not be within the purchase scope or the usage scope. Unless otherwise specified in the contract, all statements, information, and recommendations in this document are provided "AS IS" without warranties, guarantees or representations of any kind, either express or implied.

    The information in this document is subject to change without notice. Every effort has been made in the preparation of this document to ensure accuracy of the contents, but all statements, information, and recommendations in this document do not constitute a warranty of any kind, express or implied.

    Huawei Technologies Co., Ltd.

    Address: Huawei Industrial Base

    Bantian, Longgang

    Shenzhen 518129

    People's Republic of China

    Website: http://www.huawei.com

    Email: [email protected]

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    i

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet SwitchesUpgrade Guide Change History

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    ii

    Change History

    Changes between document issues are cumulative. The latest document issue contains all the changes in earlier issues.

    Issue 01 (2011-09-30)

    This issue is the first official release.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide Contents

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    iii

    Contents

    Change History................................................................................................................................ ii

    1 Before You Start.............................................................................................................................1

    1.1 Version Requirements Before Upgrade ............................................................................................................ 1

    1.2 Impact of Patch Installation.............................................................................................................................. 1

    1.3 Impact on the System During Installation ........................................................................................................ 1

    1.3.1 Impact on the System After Installation.................................................................................................. 2

    1.4 Cautionary Notes Before the Upgrade ............................................................................................................. 2

    2 Upgrade Process ............................................................................................................................4

    2.1 Upgrade Flowchart........................................................................................................................................... 4

    3 Preparations for Upgrade ............................................................................................................5

    3.1 Preparation Checklist ....................................................................................................................................... 5

    3.2 Checking the Current System Software Version .............................................................................................. 6

    3.3 Checking the Running Status of the Device..................................................................................................... 6

    3.4 Setting Up an Environment for the Upgrade.................................................................................................... 6

    3.5 Obtaining Required Software for the Upgrade................................................................................................. 8

    3.6 Backing Up the Key Data in the Flash Memory .............................................................................................. 9

    3.7 Checking the Flash Memory Space.................................................................................................................. 9

    4 Upgrade Operations on a Single Switch ................................................................................12

    4.1 Upgrading the Switch to V100R006C00SPC800 Using the Command Line................................................. 12

    4.2 Upgrading the Switch to the V100R006C00SPC800 Using the BootROM................................................... 21

    4.2.1 Upgrading the BootROM...................................................................................................................... 22

    4.2.2 Uploading the System Software............................................................................................................ 26

    4.2.3 Specifying the System Software to Be Loaded for Starting the Switch ................................................ 31

    4.2.4 Restarting the Switch ............................................................................................................................ 33

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide Contents

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    iv

    4.3 Upgrading the S5700-SI to V100R006C00SPC800 Using the USB Flash Drive .......................................... 33

    4.3.1 Overview............................................................................................................................................... 33

    4.3.2 Upgrading the Software Using the USB Flash Drive............................................................................ 34

    5 Upgrade Operations on a Stack................................................................................................38

    5.1 Upgrading All Stack Member Switches to V100R006C00SPC800 by Using the Command Line ................ 38

    5.2 Using the Intelligent Upgrade Function ......................................................................................................... 41

    5.2.1 Overview............................................................................................................................................... 41

    5.2.2 Upgrading a New Member Switch Using the Intelligent Upgrade Function ........................................ 42

    6 Verifying the Upgrade ...............................................................................................................45

    6.1 Verification Checklist ..................................................................................................................................... 45

    6.2 Checking the Current System Software Version ............................................................................................ 45

    6.3 Checking the Device Running Status ............................................................................................................. 46

    6.4 Checking the System Configuration............................................................................................................... 46

    7 Version Rollback.........................................................................................................................48

    7.1 S2700 Version Rollback ................................................................................................................................. 48

    7.1.1 Version Rollback Flowchart.................................................................................................................. 48

    7.1.2 Loading the Previous System Software ................................................................................................ 49

    7.1.3 Performing Version Rollback................................................................................................................ 49

    7.1.4 Verifying Version Rollback ................................................................................................................... 49

    7.2 S3700 Version Rollback ................................................................................................................................. 50

    7.2.1 Version Rollback Flowchart.................................................................................................................. 50

    7.2.2 Loading the Previous System Software ................................................................................................ 50

    7.2.3 Performing Version Rollback................................................................................................................ 51

    7.2.4 Verifying Version Rollback ................................................................................................................... 51

    7.3 S5700 Version Rollback ................................................................................................................................. 51

    7.3.1 Version Rollback Flowchart.................................................................................................................. 51

    7.3.2 Loading the Previous System Software ................................................................................................ 52

    7.3.3 Performing Version Rollback................................................................................................................ 52

    7.3.4 Verifying Version Rollback ................................................................................................................... 52

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 1 Before You Start

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    1

    1 Before You Start 1.1 Version Requirements Before Upgrade

    T efore uable 1-1 Version requirements b pgrade

    Version Upgrade Instruction

    S2700, S3700, S5700, S6V100R006C00SPC300

    700

    V100R006C00SPC500

    V100R006C00SPC600

    This version can be directly upgraded to V100R006C00SPC800.

    1.2 ImpactBefore you upgrade an earlier version to the V100R006C00SPC800, read this chapter

    ing system.

    he System During Installation

    Impact on Servic

    The

    of Patch Installation

    carefully to understand the possible impacts of the upgrade on the exist

    1.3 Impact on t

    es

    switch will restart during the upgrade and service will be interrupted.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 1 Before You Start

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    2

    NOTE The service interruption time depends on many factors, such as the system software size, upgrade method, operator's skill, and service configurations. The following service interruption time is for your

    owing examples, the switches are not configured and they are not in any stack. In addition, all these switches can provide the PoE function.

    ed by using the BootROM and the system software is uploaded throu e, the service interruption time is as follows (the baudrate is

    52

    If the swit ed by using the BootROM and the system software is uploaded ou TP mode), the service interruption time is as follows:

    0: 5.5 minutes

    If the ded by using the command line, the service interruption time is as

    When the system restarts, the communication between the switch and the NMS is interrupted. e as the service interruption time.

    1.3.1 Impact on the System After Installation

    1.4 Cautionar

    reference.

    In the foll

    If the switches are upgradgh the serial interfac

    11 00):

    z S2700: 30 minutes

    z S3700: 37 minutes

    z S5700: 44 minutes

    ches are upgradthr gh the network port (F

    z S2700: 5.5 minutes

    z S370

    z S5700: 6 minutes

    switches are upgrafollows:

    z S2700: 3 minutes

    z S3700: 3 minutes

    z S5700: 3 minutes

    Impact on Network Communication

    The communication interruption time is the sam

    There is no adverse impact on the system.

    y Notes Before the Upgrade Consider the following cautionary points before performing the upgrade:

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 1 Before You Start

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    3

    z The flash memory of the S3728/S3752/S2752 can store only one startup file; therefodelete the current startup file before performing the upgrade. (If there are remaining filesin the flash memory, delete them.)

    When you upgrade

    re,

    z the software using the command line, stack upgrade, or USB flash

    z

    not saved, the configuration will be lost in the case of

    z

    command in the interface view after the upgrade; otherwise, the MAC swap loopback configuration will be invalid.

    z After the arp learning dhcp-trigger command is used on a VLANIF interface of the DHCP relay agent in V100R006, dynamic ARP entries are generated only after DHCP snooping in the corresponding VLAN or on the physical interface connected to users.

    drive, do not copy or delete files.

    After the version is upgraded, ensure that the configuration is saved because a later version is compatible with early versions but an early version is incompatible with later versions. If the configuration is version rollback.

    If the loopback local swap-mac or loopback remote swap-mac command has been used on an interface in V100R006 to configure MAC swap loopback, run the start

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 2 Upgrade Process

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    4

    2 Upgrade Process 2.1 Upgrade Flowchart

    Figure 2-1 Upgrade flowchart

    Start

    Preparation

    Upgrade

    See chapter 3

    See chapters 4 and 5

    Verification See chapter 6 Rollback See chapter 7

    Yes

    YesNo

    End

    Yes

    NOTE In the following chapters, the version is upgraded to V100R006C00SPC800.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    5

    3 Preparations for Upgrade 3.1 Prepara

    Table 3-1 t

    tion Checklist

    Upgrade preparation checklis

    No. Item Check Point Result

    1 Check the system software version

    The system software version is between V100R006 and V100R006C00SPC800.

    2 running status of normally. Check thethe device

    The switch functions

    3 ironment for the ent is set up for the Set up an envupgrade

    An environmupgrade as required.

    4 software for uired for the upgrade is Obtain requiredthe upgrade

    Software reqobtained.

    5 ta in the flash memory

    ory is Back up the key da All the key data in the flash membacked up.

    6 Check the available space in the flash memory

    The space in the flash memory is sufficient for storing the system software package and other files such

    as patch files and configuration files.

    e. In the following sections, the S2700 is used as an example to describe the upgrad

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    6

    3.2 Checking the Current System Software Version un the display version command to view the version of the system software.

    ion Routing Platform Software

    700 V100R006C00)

    EDFEA 0(Master) : EDFE uptime is 0 day, 0 hour, 1 minute

    3.3 Checking the Running Status of the Device Status is

    Normal, the device can be upgraded.

    - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - - -

    3.4 Setting

    Setting Up an Envir ading the System Using TFTP or FTP

    Transfer Protocol (FTP) to download the system software, and set it th e. Figure s stem using P

    ent for upgrading the system using TFTP or FTP are as follows:

    z You can log in to the switch from a PC through the serial interface or Telnet.

    z The server and the switch can communicate with each other.

    z Files for the upgrade are stored in the server.

    R

    display versHuawei Versatile VRP (R) Software, Version 5.70 (S2Copyright (C) 2003-2010 HUAWEI TECH Co., Ltd. Quidway S2718TP-SI Routing Switch uptime is 0 day, 0 hour, 1 minute

    64M bytes DDR Memory 16M bytes FLASH Pcb Version : CX22EDFE REV C Basic BOOTROM Version : 118 Compiled at Nov 4 2009, 17:23:15 Software Version : VRP (R) Software, Version 5.70 (S2700 V100R006C00)

    Run the display device command to check the switch running status. If the value of

    display device P S2718TP-EI's Device status: Slot Sub Type Online Power Register Status Role

    0 - 2718F Present PowerOn Registered Normal Master

    Up an Environment for the Upgrade

    onment for Upgr

    In the BootROM menu or the command line view, you can use the Trivial File Transfer Protocol (TFTP) or Fileas e next startup system software. Then restart the device to complete the upgrad3-1 hows the network diagram for setting up an environment for upgrading the syFT or TFTP.

    The general requirements for setting up an environm

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    7

    Figure 3-1 Network diagram of upgrading the system using TFTP or FTP

    Setting Up an Environment for Upgrading the System Using Xmodem

    You can upgrade the basic and advanced BootROM software using Xmodem in the basic BootROM menu; you can upgrade the system software using Xmodem in the BootROM menu. Figure 3-2 shows the network diagram for setting up an environment for upgrading the system using Xmodem.

    The general requirements for setting up an environment for upgrading the system using Xmodem are as follows:

    z The RS-232 serial interface on the PC and the console interface on the switch are connected through a console cable.

    z Files for the upgrade are stored on the PC.

    Figure 3-2 Network diagram of upgrading the system using Xmodem

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    8

    3.5 Obtaining Required Software for the Upgrade To obtain the required software for the upgrade, contact Huawei technical support personnel.

    Table 3-2 Software for different upgrade methods

    Upgrade Method Matching Software

    Upgrading the version to V100R006C00SPC800 using the command line

    System software

    z S2700: S2700-V100R006C00SPC800.CC

    z S2752: S2700_52P-V100R006C00SPC800.CC

    z S3728: S3700_28TP-V100R006C00SPC800.CC

    z S3752: S3700_52P-V100R006C00SPC800.CC

    z S5700-EI: S5700EI-V100R006C00SPC800.CC

    z S5700-SI: S5700SI-V100R006C00SPC800.CC

    z S6700: S6700-V100R006C00SPC800.CC

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    9

    Upgrade Method Matching Software

    Upgrading the version to V100R006C00SPC800 using BootROM

    BootROM

    z S2700: S2700_bootrom.bin

    z S2752: S2700_52P_bootrom.bin

    z S3728: S3700_28TP_bootrom.bin

    z S3752: S3700_52P_bootrom.bin

    z S5700-EI: S5700EI_bootrom.bin

    z S5700-SI: S5700SI_bootrom.bin

    z S6700: S6700_bootrom.bin

    System software

    z S2700: S2700-V100R006C00SPC800.CC

    z S2752: S2700_52P-V100R006C00SPC800.CC

    z S3728: S3700_28TP-V100R006C00SPC800.CC

    z S3752: S3700_52P-V100R006C00SPC800.CC

    z S5700-EI: S5700EI-V100R006C00SPC800.CC

    z S5700-SI: S5700SI-V100R006C00SPC800.CC

    z S6700: S6700-V100R006C00SPC800.CC

    3.6 Backing Up the Key Data in the Flash Memory You must back up the key data stored in the flash memory before the upgrade. You can download the data that needs to be backed up to the PC through FTP or TFTP. After the upgrade, you can reload the backup files to the flash memory. For details, see 4.1 Upgrading the Switch to V100R006C00SPC800 Using the Command Line.

    3.7 Checking the Flash Memory Space 1. Run the dir command in the user view to check whether the flash memory space is sufficient

    for the system software. If a stack is established, ensure that all the members in the stack have enough space.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    10

    The preceding information shows that there is 2,266 KB space. If there is enough space, ignore step 2.

    dir Directory of flash:/

    Idx Attr Size(Byte) Date Time(LMT) FileName 0 -rw- 6,458,620 Jan 08 2008 03:35:29 s2700-v100r006c00.cc 1 -rw- 603 Jan 02 2008 02:57:45 vrpcfg.zip 2 -rw- 628 Jan 01 2008 00:00:52 private-data.txt 3 -rw- 6,177,996 Jan 02 2008 02:57:00 s-s2700.cc

    14,632 KB total (2,266 KB free)

    2. (Optional) Load and activate the patch file S27_37_57-V100R006SPH005.pat.

    Before upgrading an S2752 or S3700 to V100R006, delete the current startup file to free up the flash memory space.

    If no system software is stored on the device, do not restart or power cycle the device during the upgrade. Otherwise, the system may break down. If the device is powered off unexpectedly during the upgrade, use the BootROM to upgrade the device. If the upgrade using BootROM fails, contact Huawei engineers.

    3. Run the delete command to delete unnecessary files to ensure there is enough space for storing relevant upgrade files. Before deleting the unnecessary files, ensure that the files are backed up or are unwanted. The following is an example of deleting the s-s2700.cc file. For details, see "Managing the File System" in the Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Configuration Guide Basic Configurations.

    After you run the delete /unreserved command to delete a file from the flash, the file cannot be restored; therefore, run this command with caution, and a file backup is recommended.

    delete /unreserved s-s2700.cc Warning: The contents of file flash:/ s-s2700.cc cannot be recycled. Continue? [Y/N]:y Info: Deleting file flash:/ s-s2700.cc... Deleting file permanently from flash will take a long time if needed....... ................................................................................

    ................................................................................

    ................................................................................

    ................................................................................

    ................................................................................

    ................................................................................su

    cceeded.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 3 Preparations for Upgrade

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    11

    ----End

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    12

    4 Upgrade Operations on a Single Switch 4.1 Upgrading the Switch to V100R006C00SPC800 Using the Comm

    The command line upgrade method has little impact on services; therefore, you are advised to u operatin

    and Line

    pgrade an g device by using the command line.

    To upgrade the system software Purpose

    Services are interrupted when the device restarts. Impact

    In the scenario where a single device is configured and service deployment is simple, services are interrupted about three minutes. In

    in time increases and the time depends on the complexity of

    Time Required

    the scenario where service deployment is complicated, the service terruption

    service.

    Requirements z ns system software of an earlier version functions properly.

    z The available space in the flash memory is sufficient for storing the system software.

    The switch that ru

    z

    z

    z The S5700/S6700 has a dedicated management interface, namely, MEth. The MEth interface can be

    z Before the upgrade, use the terminal monitor command to enable the terminal to display logs, traps, the information center.

    u ds to load the system software:

    Before the S2752/S3700 is upgraded, you must delete the original startup file. For details on how to delete the original startup file, see section 3.7 Checking the Flash Memory Space.

    The methods of upgrading the system software using command line are similar on the S2700, S3700, S5700, and the S6700. In the following description, the system software of the S2700 is upgraded.

    used as the Layer 3 interface.

    and debugging information sent from

    Yo can use any of the following metho

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    13

    z Use the S2700 as the TFTP client.

    z Use the S2700 as the FTP server.

    Method 1: Use th

    z Use the S2700 as the FTP client.

    e S2700 as the TFTP Client

    No TFTP client software is installed on the S2700; therefore, the customer needs to buy TFTP client software and install it. The TFTP32 program is recommended.

    1. Configure the TFTP server.

    n

    z

    he system, for can manually change

    Ru the TFTP server program on the PC and configure the PC:

    Click Browse to set the directory for storing the new system software.

    z The TFTP server address in Server interface is automatically set by texample, 10.164.30.29. However, if the IP address is incorrect you it.

    Do not stop the TFTP server program when you are backing up data.

    2. Back up the system software, configuration file, and patch files to the TFTP server.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    14

    Before the backup, check the size of the configuration file. After the backup, compare the size o files are the same size.

    uidway> dir *.cc

    te) Date Time(LMT) FileName 0 -rw- 6,472,284 Nov 04 2010 19:43:18 s2700-v100r006c00.cc

    uidway> dir *.zip

    te) Date Time(LMT) FileName 0 -rw- 589 Nov 04 2010 20:55:54 vrpcfg.zip

    uidway> dir *.pat

    14,632 KB total (8,228 KB free)

    are atch

    -v100r006c00-bak.cc

    27_37_57-v100r006sph005.pat s27_37_57-v100r006sph005-bak.pat

    Uploading the file to the remote TFTP server. Please wait...\

    3. from the server.

    tftp 10.164.30.29 get S2700-V100R006C00SPC800.cc

    the file from the remote TFTP server. Please wait.../ TFTP: Downloading the file successfully.

    If the message "Downloading the file successfully" is displayed, the system software has been

    4.

    of the original file with the size of the backup file. Ensure that the tw

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    15

    If the configuration file does not need to be changed after the upgrade, this step is not

    gnew.zip Info: Transfer file in binary mode.

    TFTP: Downloading the file successfully.

    5. system software in service, which is loaded when the S2700 is started.

    startup system-software s2700-V100R006C00SPC800.cc

    If the following information is displayed after you run the startup systeY to update the BootROM. If the BootROM is upgraded successfully, go

    m-software file command, enter to step 7; otherwise, go to step

    6.

    [N]: y BOOTROM begin to be upgraded ! please wait for a moment

    Info: BOOTROM UPGRADE OK

    6. he S2700 is started.

    uidway> system-view otrom s2700-V100R006C00SPC800.cc

    BOOTROM begin to upgraded ! please wait for a minute...

    InfoSucc

    Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)

    Succeeded in setting the software for booting system.

    Upgrade the BootROM in service, which is loaded when t

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    16

    ----End

    Method 2: Use the S2700 as the FTP Server

    No FTP server software is installed on the S2700; therefore, the customer needs to buy FTP server

    1. the S2700 as an FTP server.

    0, and set the FTP user name to ftpuser and password to

    ser service-type ftp [Quidway-aaa] local-user ftpuser ftp-directory flash:

    2.

    d. This example assumes that ethernet/0/0/1 is used

    ew

    port link-type access

    ernet 0/0/1 n10] quit

    1.1 24 quit

    3. Log

    software and install it.

    Configure

    Start the FTP server on the S270ftppwd.

    system-view [Quidway] ftp server enable [Quidway] aaa [Quidway-aaa] local-user ftpuser password simple ftppwd [Quidway-aaa] local-user ftpu

    [Quidway-aaa] return

    Set an IP address for the S2700.

    An idle service interface is recommendeand the IP address is 1.1.1.1/24.

    system-vi [Quidway]interface ethernet 0/0/1 [Quidway-Ethernet0/0/1][Quidway-Ethernet0/0/1]quit [Quidway] vlan 10 [Quidway-vlan10] port eth[Quidway-vla[Quidway] interface vlanif 10 [Quidway-Vlanif10] ip address 1.1.[Quidway-Vlanif10] [Quidway]

    in to the FTP server (the S2700).

    Assume that the Windows XP operating system is used.

    Store the file to be uploaded in the specified directory (for example, D:\>directory). Choose cmd and press Enter. Enter FTP 1.1.1.1. Enter the user name at the user

    at the password prompt, and then press Enter. The following

    o 1.1.1.1. .

    .1.1.1:(none)): ftpuser

    Start > Run. Enterprompt and the password information is displayed:

    D:\>ftp 1.1.1.1 Connected t220 FTP service readyUser (1331 Password required for 1. Password:

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    17

    230 User logged in.

    4. onfiguration file, and patch files.

    ceived in 20.33Seconds 1350.65Kbytes/sec.

    nsferred and you can find it

    60Kbytes/sec.

    n find it

    226 Transfer complete. ds 1333.74Kbytes/sec.

    The preceding output indicates the configuration file has been transferred and you can find it

    5. Upload the system software for the S2700.

    0R006C00SPC800.CC. 226 Transfer complete.

    6. (Optional) Upload the new configuration file to the S2700.

    ot required.

    put vrpcfgnew.zip

    7. Spe

    startup system-software s2700-V100R006C00SPC800.cc

    ftp>

    Back up the system software, c

    ftp> binary 200 Type set to I. ftp> get s2700-v100r006c00.cc 200 Port command okay. 150 Opening BINARY mode data connection for s2700-v100r006c00.cc. 226 Transfer complete. ftp: 6472284 bytes re

    The preceding output indicates the configuration file has been train D:\>.

    ftp> get vrpcfg.zip 200 Port command okay. 150 Opening BINARY mode data connection for vrpcfg.zip 226 Transfer complete. ftp: 589 bytes received in 0.01Seconds

    The preceding output indicates the configuration file has been transferred and you cain D:\>.

    ftp> get s27_37_57-v100r006sph005.pat 200 Port command okay. 150 Opening BINARY mode data connection for s27_37_57-v100r006sph005.pat.

    ftp: 333436 bytes received in 0.25Secon

    in D:\>.

    Run the put source-filename [ destination-filename ] command on the FTP client (PC) to m the PC. upload the system software fro

    ftp> put D:\S2700-V100R006C00SPC800.cc 200 Port command okay. 150 Opening BINARY mode data connection for S2700-V10

    ftp: 6502764 bytes in 47.10Seconds 140.76Kbytes/sec. ftp>

    If the configuration file does not need to be changed after the upgrade, this step is n

    ftp>

    cify the system software in service, which is loaded when the S2700 is started.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    18

    is displayed after you run the startup system-software file command, enter

    ly, go to step 9; otherwise, go to step

    raded ! please wait for a moment

    g system.

    8. the BootROM in service, which is loaded when the S2700 is started.

    upgrade basic-bootrom s2700-V100R006C00SPC800.cc Warn

    Upgr

    [Slo

    If the following information Y to update the BootROM. If the BootROM is upgraded successful8.

    Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y BOOTROM begin to be upg

    Info: BOOTROM UPGRADE OK Succeeded in setting the software for bootin

    (Optional) Upgrade

    system-view [Quidway]

    ing: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y ading BOOTROM,please wait for a moment

    t 0]: Info: BOOTROM UPGRADE OK.

    In the V

    e100R005 and V100R006, the BootROM is upgraded automatically. To upgrade the software to

    9.

    other v rsions, you must upgrade the BootROM manually. For details about automatic BootROM upgrade, see Step 7. In the case of a version rollback, you are advised to manually upgrade the BootROM to prevent a rollback failure

    Restart the S2700.

    After the software is upgraded to V100R006C00SPC800, you must specify the system software for next

    e device will fail to

    guration, enter y or n. After the setting is

    figuration, please wait. All the configuration will be saved to the configuration file for the next

    Now saving the current configuration to the slot 0. Info: Save the configuration successfully.

    y

    it

    Method 3: Use the S2700 as the FTP Client

    startup. If the system software is not specified or the invalid software is specified, threstart. For details about specifying the system software for next startup, see step 7.

    When the system asks you whether to save the conficomplete, enter y to restart the system.

    reboot Info: The system is now comparing the conWarning:startup:flash:/vrpcfg.zip, Continue?[Y/N]:y

    System will reboot! Continue?[Y/N]: Info: system is rebooting, please wa

    ----End

    No FTP client software is installed on the S2700; therefore, the customer needs to buy FTP client software and install it.

    1. Configure the PC as the FTP server.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    19

    Run an FTP server program on the PC, for example, wftpd32. Choose Users/rights.

    Security >

    Click New User to set the user name and password. Here, the user name is S2700 and the tory text box. Here, the

    root directory is D:\ftp. Click Done to close the dialog box.

    Do not stop the FTP server program when you are backing up data.

    2.

    he S2700 are the same as the FTP commands in the DOS system. server is 10.164.30.27, the FTP user name is S2700,

    user is 123456.

    Enter the user name and press Enter. ease

    : # Enter the password 123456 and press Enter. The password displayed xt.

    r and specify the name

    password is 123456. Enter the FTP root directory in the Home Direc

    Back up the system software, configuration file, and patch files.

    The FTP commands on tAssume that the IP address of the FTPand the password of the FTP

    cd flash:/ ftp 10.164.30.27 Trying 10.164.30.27 ... Press CTRL+K to abort Connected to 10.164.30.27. 220 WFTPD 2.0 service (by Texas Imperial Software) ready for new user User(10.164.30.27:(none)):S2700 #331 Give me your password, plEnter passwordon the screen is in cipher te230 Logged in successfully [ftp] binary 200 Type is Image (Binary)

    Back up the system software s2700-v100r006c00.cc to the FTP serveof the backup file as s2700-v100r006c00-bak.cc. If the name of the backup file is not specified, the original name is used.

    [ftp] put s2700-v100r006c00.cc s2700-v100r006c00-bak.cc 200 PORT command successful 150 Opening BINARY mode data connection for file transfer 226 Transfer complete. FTP: 6472284 byte(s) sent in 41.176 second(s) 1296.55Kbyte(s)/sec.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    20

    Back up the configuration file vrpcfg.zip to the FTP server and specify the name of the backup file as vrpcfg-bak.zip. If the name of the backup file is not specified, the original

    [ftp] put vrpcfg.zip vrpcfg-bak.zip

    FTP: 1387 byte(s) sent in 0.176 second(s) 22.04Kbyte(s)/sec.

    cify the

    .pat

    200 PORT command okay " file ready to receive in IMAGE / Binary

    mode

    FTP: 333436 byte(s) sent in 0.322 second(s) 1035.51Kbyte(s)/sec.

    3.

    file transfer 226 Transfer complete.

    econd(s) 1117.40Kbyte(s)/sec.

    You can specify the filename of the upgrade program. If the filename is not specified, the

    4. onfiguration file.

    s not need to be changed after the upgrade, this step is not

    221 Windows FTP Server (WFTPD, by Texas Imperial Software) says goodbye

    6. Spe

    startup system-software s2700-V100R006C00SPC800.cc

    name is used.

    200 PORT command successful 150 Opening BINARY mode data connection for file transfer 226 Transfer complete.

    Back up the patch file s27_37_57-v100r006sph005.pat to the FTP server and spename of the backup file as s27_37_57-v100r006sph005bak.pat. If the name of the backup file is not specified, the original name is used.

    [ftp] put s27_37_57-v100r006sph005.pat s27_37_57-v100r006sph005bak

    150 "D:\ftp\ s27_37_57-v100r006sph005bak.pat

    226 Transfer finished successfully.

    Obtain the system software of the target version.

    [ftp] get S2700- V100R006C00SPC800.cc

    200 PORT command successful 150 Opening BINARY mode data connection for

    FTP: 6502764 byte(s) received in 54.500 s

    original name is used.

    (Optional) Obtain the new c

    If the configuration file doerequired.

    [ftp] get vrpcfgnew.zip

    5. Close the FTP connection.

    [ftp] bye

    cify the system software in service, which is loaded when the S2700 is started.

    If the following information is displayed after you run the startup system-software file command, enter Y to update the BootROM. If the BootROM is upgraded successfully, go to step 8; otherwise, go to step

    Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y

    7.

    BOOTROM begin to be upgraded ! please wait for a moment

    Info: BOOTROM UPGRADE OK Succeeded in setting the software for booting system.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    21

    7. h is loaded when the S2700 is started.

    trom s2700-V100R006C00SPC800.cc Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y Upgrading BOOTROM,please wait for a moment

    [SloInfo

    (Optional) Upgrade the BootROM in service, whic

    system-view[Quidway] upgrade basic-boo

    t 0]: : BOOTROM UPGRADE OK.

    and V100R006, the BootROM is upgraded automatically. To upgrade the software to

    other versions, you must upgrade the BootROM manually. For details about automatic BootROM tep 6. In the case of a version rollback, you are advised to manually upgrade the

    BootROM to prevent a rollback failure.

    8. Res

    In the V100R005

    upgrade, see S

    tart the S2700.

    NOTE After the software is upgraded to V100R006C00SPC800, you must specify the system software for next startup. If the system software is not specified or the invalid software is specified, the device will fail to

    about specifying the system software for next startup, see step 6.

    guration, please wait. ved to the configuration file for the next

    startup:flash:/vrpcfg.zip, Continue?[Y/N]:y ng the current configuration to the slot 0.

    Info: Save the configuration successfully. System will reboot! Continue?[Y/N]: y Info: system is rebooting, please wait

    4.2 UpgradUsing the

    If the BootROM method is used, the services will be interrupted for a long time; therefore, you are advised to upgrade an operating device by using the command line. If the device cannot enter the command line mode, upgrade the device by using the BootROM.

    restart. For details

    When the system asks you whether to save the configuration, enter y or n. After the setting is complete, enter y to restart the system.

    reboot Info: The system is now comparing the confiWarning: All the configuration will be sa

    Now savi

    ----End

    ing the Switch to the V100R006C00SPC800 BootROM

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    22

    Figure 4-1 Flowchart for upgrading the version to the V100R006C00SPC800 using the BootROM

    End

    Start

    Upgrade BootROM See 4.2.1

    Upload systemsoftware See 4.2.2

    Specify startupsoftware See 4.2.3

    Restart the switch See 4.2.4

    The methods for upgrading the system software using the BootROM are similar on the S2700, S3700, S5700 and the S6700. Here, the method for upgrading the system software on the S2700 is taken as an example.

    4.2.1 Upgrading the BootROM Purpose To upgrade the BootROM

    Services are interrupted during the upgrade and the device reboot. Impact

    The upgrade takes about 100 seconds when the transmission rate of the serial interface is 115200 bit/s.

    Time Required

    After backing up the key data in the flash memory, you must run the reboot command in the user view to restart the system.

    Prerequisites

    Do not restart or power off the S2700 when the information "Update BOOTROM system" is being displayed during the upgrade of the BootROM. Otherwise, the S2700 runs abnormally. In this case, contact Huawei technical personnel.

    You can restart or power off the S2700 only when the message "done!" is displayed.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    23

    The BootROM menu varies according to the version. Here, the BootROM of V100R006C00SPC800 is taken as an example.

    1. Use a serial cable to connect the serial interfaces on the PC and the S2700 and start the HyperTerminal on the PC.

    2. Enter the connection name and click OK.

    3. Select the serial interface and click OK.

    4. On the COM Properties page, click Restore Defaults. Then set the value of Bits per second to 9600 and click OK.

    5. If the prompt is displayed on the HyperTerminal, the HyperTerminal is connected to the S2700. In this case, you can upgrade the S2700 using the BootROM.

    6. Enter the BootROM menu.

    Before entering the BootROM menu, you need to restart the S2700. During the restart of the S2700, the following information is displayed:

    Press Ctrl+B to enter BOOTROM menu... 1

    Press Ctrl+B before the countdown timer expires, and then enter the password. The default password is huawei or www.huawei.com. Then the advanced BootROM menu is displayed. The following information is displayed:

    BOOTROM MENU

    1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu 6. Modify BOOTROM password 7. Reboot

    Enter your choice(1-7):

    7. Enter the BootROM submenu.

    Select 2. Enter serial submenu. The following information is displayed:

    SERIAL SUBMENU

    1. Update BOOTROM system 2. Download file to Flash through serial interface 3. Modify serial interface parameter 4. Return to main menu

    8. Modify the parameters of the serial interface.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    24

    Changing the transmission rate of the serial interface causes interruption of the communication between the PC and S2700. To restore the communication between the PC and the S2700, you must set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2700.

    Select 3. Modify serial interface parameter. The following information is displayed:

    Enter your choice(1-5): 3 1: 9600(default) 2: 19200 3: 38400 4: 57600 5: 115200

    please select an appropriate baudrate: Enter your choice(1-5):

    Select the transmission rate for the serial interface as required. The transmission rate is expressed in bit/s. The default transmission rate of the serial interface on the S2700 is 9600 bit/s. A greater value you enter represents a higher transmission rate of the serial interface. It is recommended that you enter 5: 115200.

    If you change the transmission rate of the serial interface on the S2700, set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2700. In this manner, you can restore the communication between the PC and the S2700.

    For example, after you select 5: 115200, the following information is displayed:

    BaudRate is 115200 bps. Please change the terminal's speed to 115200 bps

    In this case, you need to perform the following settings on the HyperTerminal of the PC to restore the communication between the PC and the S2700:

    z On the HyperTerminal, choose Call > Disconnect. The connection is closed

    z Choose File > Properties. The Properties dialog box is displayed.

    z On the Connect To tab page, click Configure. The COM Properties dialog box is displayed.

    z In the Bits per second drop-down list, select 115200.

    z In the COM Properties and Properties dialog boxes, click OK.

    z On the HyperTerminal, choose Call > Call. Press Enter. The connection is reestablished.

    9. Upgrade the BootROM.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    25

    The BootROMs for products of various series are incompatible with each other. For example, the BootROM of the S2700 cannot be used to upgrade the BootROM of the S3700; the BootROM of the S3700 cannot be used to upgrade the BootROM of the S2700.

    Select 1. Update BootROM system. The following information is displayed:

    Enter your choice(1-4): 1

    Please Select File. XMODEM downloading ...CC

    Choose Transfer > Send File. The Send File dialog box is displayed.

    Click Browse. Then select the bootrom128.bin file for upgrading the BootROM.

    Ensure that the selected BootROM file corresponds to the product.

    Select XMODEM from the Protocol drop-down list box. Click Send to start sending the file.

    After the upgrade file is transferred, the following information is displayed:

    XMODEM downloading ...CC download to SDRAM successfully Warning: Don't Power-off or Reset the Device!!! Update bootrom system ... done !

    Then, the S2700 automatically upgrades the BootROM by using the upgrade file. After the upgrade, the S2700 automatically returns to the BootROM menu.

    10. After the BootROM is upgraded, restore the default rates of the serial interface and the HyperTerminal, and then reestablish the connection.

    Select 4. Return to main menu in the BootROM menu to return to the BootROM menu, and then select 7. Reboot to reboot the BootROM.

    ----End

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    26

    4.2.2 Uploading the System Software

    Uploading the System Software Through the Serial Interface

    Purpose To upgrade the system software

    Services are interrupted during the system software uploading and the device reboot.

    Impact

    The software uploading time depends on many factors, such as the system software size, transmission rate on the serial interface, and operator's skill. When the transmission rate of the serial interface is 115200 bit/s, the uploading time is about 30 minutes.

    Time Required

    Prerequisites z The matched BootROM is upgraded.

    z The flash memory has enough space to store the system software.

    1. Enter the BootROM menu.

    When the S2700 is starting, the following information is displayed:

    Press Ctrl+B to enter BOOTROM menu... 1

    Press Ctrl+B before the countdown timer expires, and then enter the password. The default password is huawei. Then the advanced BootROM menu is displayed. The following information is displayed:

    BOOTROM MENU

    1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu 6. Modify BOOTROM password 7. Reboot

    Enter your choice(1-7):

    2. Select 2. Enter serial submenu. The following information is displayed:

    SERIAL SUBMENU

    1. Update BOOTROM system 2. Download file to Flash through serial interface 3. Modify serial interface parameter 4. Return to main menu

    Enter your choice(1-4):

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    27

    3. Modify the parameters of the serial interface.

    Changing the transmission rate of the serial interface causes interruption of the communication between the PC and S2700. To restore the communication between the PC and the S2700, you must set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2700.

    Select 3. Modify serial interface boot parameter. The following information is displayed:

    1: 9600(default) 2: 19200 3: 38400 4: 57600 5: 115200

    please select an appropriate baudrate: Enter your choice(1-5):

    Select the transmission rate for the serial interface as required. The transmission rate is expressed in bit/s. The default transmission rate of the serial interface on the S2700 is 9600 bit/s. A greater value you enter represents a higher transmission rate of the serial interface. It is recommended that you enter 5. 115200. If you change the transmission rate of the serial interface on the S2700, set the transmission rate of the serial interface on the PC the same as that of the serial interface on the S2700. In this manner, you can restore the communication between the PC and the S2700.

    For example, after you select 5: 115200, the following information is displayed:

    BaudRate is 115200 bps. Please change the terminal's speed to 115200 bps

    In this case, you need to perform the following settings on the HyperTerminal of the PC to restore the communication between the PC and the S2700:

    z On the HyperTerminal, choose Call > Disconnect. The connection is closed

    z Choose File > Properties. The Properties dialog box is displayed.

    z On the Connect To tab page, click Configure. The COM Properties dialog box is displayed.

    z Select 115200bit/s from the Bits per second drop-down list box.

    z In the COM Properties and Properties dialog boxes, click OK.

    z On the HyperTerminal, choose Call > Call. The connection is reestablished.

    4. Upgrade the system software.

    Select 2. Download file to Flash through serial interface in the serial interface submenu, and the following information is displayed:

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    28

    Enter your choice(1-4): 2

    Please Select File. XMODEM downloading ...CC

    Choose Transfer > Send File. The Send File dialog box is displayed.

    Click Browse to select the upgrade file of the system software. Then select Xmodem from the Protocol drop-down list box. Click Send to start sending the file.

    After transferring the upgrade file, the system prompts you whether to change the file name. If no, save it with the default file name. The default file name is not the uploaded file name. The system software name in the flash memory or the default file name hw-switch.cc is used. Generally, it is recommended that the file name be changed.

    Only the files with the file name extension .cc can be used as the upgrade files of the system software on the S2700.

    If you need to name the upgrade file S2700-V100R006C00SPC800.CC, the following information is displayed:

    XMODEM downloading ...CC download successfully! Do you like to save it named " S2700-V100R006C00SPC800.CC"? If you like then press return key, otherwise give a new name for saving it: S2700-V100R006C00SPC800.CC

    If the file S2700-V100R006C00SPC800.CC has already been saved in the flash memory, the system prompts you whether to overwrite the existing file with the new one. The following information is displayed:

    flash:/S2700-V100R006C00SPC800.CC already exist, delete it?(Y/N):y Deleting file.......................................done took time : 251s Writing Flash...............................................................................................................................................................

    ..............done

    file length: 6502764 bytes, took time : 144s

    SERIAL SUBMENU

    1. Update BOOTROM system 2. Download file to Flash through serial interface 3. Modify serial interface parameter 4. Return to main menu

    Enter your choice(1-4):

    After the upgrade file is transferred, select 4. Return to main menu to return to the BootROM menu.

    ----End

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    29

    Uploading the System Software Through the Network Port

    Purpose To upload the system software

    Services are interrupted during the system software uploading and the device reboot.

    Impact

    If the system software is uploaded through the FTP or TFTP protocol, the system software uploading time is about one minute.

    Time Required

    Prerequisites z The matched BootROM is upgraded.

    z The flash memory has enough space to store the system software.

    z The FTP service is enabled on the PC.

    Pay attention to the following points:

    z Select 4. Return to main menu in the BootROM menu to return to the BootROM menu, and then select 7. Reboot to reboot the BootROM. Enter the BootROM menu and load the system software. In addition, specify the software to be loaded in the startup.

    z Upgrade the system software using the network interface in the BootROM menu.

    1. Enter the BootROM menu.

    Before entering the BootROM menu, you need to restart the S2700. During the restart of the S2700, the following information is displayed:

    Press Ctrl+B to enter BOOTROM menu... 1

    Press Ctrl+B before the countdown timer expires, and then enter the password. The default password is huawei. Then the advanced BootROM menu is displayed. The following information is displayed:

    BOOTROM MENU

    1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu 6. Modify BOOTROM password 7. Reboot

    Enter your choice(1-7):

    2. Select 4. Enter serial submenu. The following information is displayed:

    ETHERNET SUBMENU

    1. Download file to SDRAM through ethernet interface and boot 2. Download file to Flash through ethernet interface 3. Modify ethernet interface boot parameter 4. Return to main menu

    Enter your choice(1-4):

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    30

    3. Modify the parameters of the network interface.

    Select 3. Modify ethernet interface boot parameter. The following information is displayed:

    BOOTLINE SUBMENU

    1. Set TFTP protocol parameters 2. Set FTP protocol parameters 3. Return to ethernet menu

    Select TFTP or FTP as required.

    For example, the following information is displayed if you select 2. Set FTP protocol parameters. The displayed information cannot be cleared. New settings will overwrite the old settings.

    If the TFTP protocol is used, you do not need to enter the user name and password.

    '.' = clear field; '-' = go to previous field; ^ D = quit Load File name : S2700-V100R006C00SPC800.CC Switch IP address : 192.168.1.15:FFFFFF00 Server IP address : 192.168.1.40 FTP User Name : cx

    FTP User Password : cx

    The fields are described as follows:

    z Load File name: file name of the startup file to be loaded

    z Switch IP address: device IP address (the mask is optional)

    z Server IP address: server IP address

    z FTP User Name: FTP user name

    z FTP User Password: FTP password

    4. Download the system software.

    After network interface parameters are modified, select 3. Return to ethernet menu to return to the Ethernet submenu. Connect the data line to port 1 on the S2700 panel (or connect the data line to the MEth interface of the S5700), and then select 2. Download file to Flash through ethernet interface to load the file. The following information is displayed:

    '.' = clear field; '-' = go to previous field; ^ D = quit

    boot device : et unit number : 0 processor number : 0 host name : host file name : S2700-V100R006C00SPC800.CC inet on ethernet (e) : 192.168.1.15:FFFFFF00 host inet (h) : 192.168.1.40 user (u) : cx ftp password (pw) : cx flags (f) : 0x0

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    31

    Attached TCP/IP interface to mottsec0. Attaching network interface lo0... done. Loading... Read file to sdram .......Done Writing Flash...............................................................................................done File length: 6502764 bytes Took time : 33s

    After the upgrade file is transferred, select 4. Return to main menu to return to the BootROM menu.

    ----End

    4.2.3 Specifying the System Software to Be Loaded for Starting the Switch

    Purpose To specify the system software for next startup

    Services are interrupted when you are specifying the system software and the device is restarting.

    Impact

    The system software to be specified has been downloaded to the flash memory.

    Prerequisite

    1. Specify the system software to be loaded for starting the switch.

    After returning to the BootROM menu, select 3. Enter startup submenu to enter the startup submenu. The following information is displayed:

    Startup Configuration Submenu

    1. Display startup configuration 2. Modify startup configuration 3. Return to main menu

    Enter your choice(1-3):

    2. Select 2. Modify startup configuration to set the startup mode of the S2700, system software, configuration file, license file, and patch file. The following information is displayed:

    Note: startup file field cannot be cleared

    '.'=clear field; '^D'=quit; Enter=use current configuration

    startup type(1: Flash 2: Server) current: 1 new : 1

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    32

    Flash startup file (cannot be cleared) current:

    new : S2700-V100R006C00SPC800.CC saved-configuration file current: vrpcfg.zip new :

    license file current:

    new :

    patch package current:

    new :

    Table 4-1 describes the displayed information.

    Table 4-1 Description of the displayed information

    Field Description

    startup type Startup mode:

    z 1: loads the system software from the flash memory.

    z 2: loads the system software from the server.

    Flash startup file System software loaded during the startup. If the system software is loaded from the server, you do not need to set the field.

    saved-configuration file Configuration file loaded during startup.

    patch package Patch file loaded during startup.

    current File that is currently loaded.

    new File to be loaded during the next startup.

    Startup Configuration Submenu

    1. Display startup configuration 2. Modify startup configuration 3. Return to main menu

    Enter your choice(1-3):

    3. After entering the startup information, select 3. Return to main menu to return to the BootROM menu.

    BOOTROM MENU

    1. Boot with default mode 2. Enter serial submenu 3. Enter startup submenu 4. Enter ethernet submenu 5. Enter filesystem submenu

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    33

    6. Modify BOOTROM password 7. Reboot Enter your choice(1-7):

    ----End

    4.2.4 Restarting the Switch

    The switch is automatically upgraded by loading the latest system software during startup.

    Enter 7. Reboot on the advanced BootROM menu to restart the switch. Then, the S2700 restores the baud rate on the console interface to 9600 bit/s. The baud rate of the HyperTerminal also needs to be set to 9600 bit/s. The PC then can communicate with the S2700.

    4.3 Upgrading the S5700-SI to V100R006C00SPC800 Using the USB Flash Drive

    4.3.1 Overview

    If you do not have a PC in the on-site deployment, use the USB flash drive in which the system software and configuration file are stored. The software commissioning engineer is not required.

    Only the S5700-SI and S6700 can be upgraded using the USB flash drive. Stacks do not support this upgrade method.

    The general process of the upgrade in the USB way is as follows:

    a. Copy files.

    When the S5700-SI is started successfully (the SYS indicator is in green and blinks at 0.5 Hz), the USB flash drive can be inserted to load files. The S5700-SI automatically downloads the system software and configuration file according to the index file in the USB flash drive.

    b. Restart the switch.

    The S5700-SI sets the system software and configuration file for next startup, and then restarts automatically.

    c. Verify the loading of files.

    After restarting successfully (the SYS indicator is in green and blinks at 0.5 Hz), the S5700-SI begins to verify the loaded files. When the SYS indicator is in orange and blinks at 0.5 Hz, the upgrade is finished.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    34

    4.3.2 Upgrading the Software Using the USB Flash Drive

    Preparations for Upgrade

    1. Prepare the hardware.

    z USB port: The S5700-SI provide USB 1.1; the S6700 provide USB 2.0.

    z USB flash drive:

    The USB flash drive delivered with Huawei switch is recommended because this USB flash drive is compatible with the switch. The USB flash drive must be paid independently. If you have not bought the USB flash drive, contact local Huawei office.

    The USB flash drive must use the FAT32 format; otherwise, set the format to FAT32 before using it.

    The space in the USB flash drive must be sufficient for the system software and configuration file.

    2. Prepare system software, configuration file, web file, and patch file.

    3. Create the index file.

    a. Create the file usbload_config.txt.

    b. Fill in the file.

    If you need to upgrade the system software, configuration file or patch file of V100R006, the index file is in any of the following formats:

    z The first line in the index file must be the SN to prevent repeated copy. The SN consists of creation

    date + time, for example, . Before copying a file, the device compares the SNs. If the SN of a file to be copied already exists, the device does not copy the file. After the file is copied, the device stores the SN. The index files without SNs are considered invalid, and the device will stop copying the files.

    z If an index file contains the following three formats, the device uses the information in format (2). If the required information is not obtained, the device uses the information in format (3) and then format (1). When only one USB flash drive is used in the upgrade, the values of mac=, esn=, and boardtype= are default. When the device obtains the value default, the device starts to copy the file without comparing it with other files.

    z When editing an index file, press Enter when a line is finished. After editing the file, save it.

    z Select the upgrade files, including system software, configuration file, Web file, and patch file as required.

    z The upgrade procedures for S5700-SI, and S6700 are the same.

    (1) To upgrade the same system software, configuration file, Web file, and patch file on multiple devices, fill in the file in the format .

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    35

    To obtain the value of boardtype, view device labels or run the display version command. boardtype=default indicates that all devices will be upgraded.

    Fill in the system software name behind vrpfile=.

    Fill in the version number behind vrpfile=.

    Fill in the configuration file name behind cfgfile=.

    Fill in the web file name behind webfile=.

    Fill in the patch file name behind patchfile=.

    The following are the index files of different devices:

    The following two formats are used for upgrading a single device:

    (2)

    View the device's MAC address on the chassis and fill in the MAC address behind mac= in the format XXXX-XXXX-XXXX.

    Fill in the system software name behind vrpfile=.

    Fill in the version number behind vrpfile=.

    Fill in the configuration file name behind cfgfile=.

    Fill in the web file name behind webfile=.

    Fill in the patch file name behind patchfile=.

    The following is an example of configuration file:

    The following is an example of patch file:

    (3)

    View the device's ESN and fill in the ESN behind esn=.

    Fill in the system software name behind vrpfile=.

    Fill in the version number behind vrpfile=.

    Fill in the configuration file name behind cfgfile=.

    Fill in the web file name behind webfile=.

    Fill in the patch file name behind patchfile=.

    The following is an example of patch file:

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    36

    The following is an example of system software:

    If a keyword is not found or matched, the value of this item is considered to be empty.

    If the version number behind vrpver= is the same as the current version, the device will not restart.

    4. Copy the index file, system software, configuration file, Web file, and patch file to the root directory of the USB flash drive.

    The index files must be stored to the root directory on the USB flash drive; the other files are stored in the corresponding directories.

    z Do not power off the switch during file copy; otherwise, the upgrade fails or the switch

    cannot start.

    z Do not remove the USB flash drive before the upgrade is finished; otherwise, the USB flash drive may be damaged.

    Procedure

    1. Power on the S5700-SI, and wait until the system completes the startup (you are advertised to wait for two minutes).

    2. Confirm that the system is operating stably (the SYS indicator is in green and blinks every two seconds). If the system operating is unstable, wait or solve the issue.

    z If the SYS indicator is on and in green or orange, the system startup is not finished. Wait until the system starts successfully.

    z If the SYS indicator is on and in red, the system is started but an error occurs. Fix the problem before the next step. Check whether the power supply and the fan function properly. If no, power off the S5700-SI, and then restart the S5700-SI. If the fault persists (the indicator is on and in red), contact Huawei technical support personnel.

    3. Insert the USB flash drive.

    z If the SYS indicator is in green and blinks more than twice every second, the system is copying the system software and configuration file from the USB flash drive.

    z After copying the files, the system restarts.

    z If the SYS indicator is in orange and blinks every two seconds after the restart, the upgrade is successful. Now you can remove the USB flash drive.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 4 Upgrade Operations on a Single Switch

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    37

    If the SYS indicator is on or blinks in red, or blinks and is in read, an error occurs. Power off the S5700-SI and power on it, and then insert the USB flash drive again. If the upgrade fails three times, check whether the index file on the USB flash drive is correct, or contact the Huawei technical support personnel.

    NOTE When using the USB flash drive for upgrade, change the SN in the USB flash drive.

    ----End

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    38

    5 Upgrade Operations on a Stack 5.1 Upgrading All Stack Member Switches to V100R006C00SPC800 by Using the Command Line

    To upgrade the system software Purpose

    Services are interrupted when the devices restart. Impact

    When a single device is upgraded and service deployment is simple, stack is upgraded, the services are interrupted about 3 minutes. When a

    Time Required

    service interruption time increases, and the time depends on the complexity of services and the stack.

    Prerequisites z The devices to be upgraded function properly.

    z The flash memory has enough space to store the system software.

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    39

    z The methods of for upgrading the system software of the S3700, S5700 and the S6700 using the

    command line interface are similar. Here, the S3700 is used as an example.

    the system software by using the S3700 as the FTP server. For other methods of loading the system software, see the Quidway S3700/S5700/S6700

    ns.

    retain the roles of the master and slave devices after the upgrade, set priority of the master switch

    z The section describes only how to download

    Series Ethernet Switches Configuration Guide - Basic Configuratio

    z The S5700/S6700 provides a management interface MEth. You can use this interface as a Layer 3 interface.

    z Toto be the highest in the stack before the upgrade.

    When an S3700 is upgraded to V100R006C00SPC800, you must delete the startup file because the flash memory space is limited.

    The following operations are performed on the master switch. Here, the stack contains two

    1.

    te /unreserved flash:/S3752-V100R006C00.cc tware. If you delete it, there is no software to e the file? [Y/N]:y

    Warning: The contents of file flash:/S3752-V100R006C00.cc cannot be recycled. Continue?

    eting file flash:/S3752-V100R006C00.cc... Deleting file permanently from flash will take a long time if

    ...........................................................

    .....................................................

    .......................................succeeded.

    0R006C00.cc e it, there is no software to

    nfirm to delete the file? [Y/N]:y flash:/S3752-V100R006C00.cc cannot be recycled.

    2. as the FTP server.

    and set the FTP user name to ftpuser and password to

    tp server enable

    member switches.

    Delete the current startup software package.

    deleInfo:This is Next startup system sofreboot successfully!Confirm to delet

    [Y/N]:y Info: Del

    needed..............................................

    ...............

    delete /unreserved slot1#flash:/S3752-V10Info:This is Next startup system software. If you deletreboot successfully!CoWarning: The contents of file slot1#Continue? [Y/N]:y Info: Deleting file slot1#flash:/S3752-V100R006C00.cc... Deleting file permanently from flash will take a long time if needed..............................................................................................................................................................

    ..................................................................................

    ..succeeded.

    Configure the switch

    Start the FTP service on the switch,ftppwd.

    system-view [Quidway] f

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    40

    [Quidway] aaa [Quidway-aaa] local-user ftpuser password simple ftppwd

    local-user ftpuser service-type ftp [Qui flash: [Quidway-aaa] return

    3.

    n an idle interface. Here, ethernet 0/0/1 is used as an example.

    view rnet 0/0/1

    an10] port ethernet 0/0/1

    y] interface vlanif 10

    [Quidway]

    4.

    [Quidway-aaa] dway-aaa] local-user ftpuser ftp-directory

    Configure an IP address for the switch.

    Configure the IP address o

    system-[Quidway]interface Ethe[Quidway-Ethernet0/0/1]port link-type access [Quidway-Ethernet0/0/1]quit [Quidway] vlan 10 [Quidway-vl[Quidway-vlan10] quit[Quidwa[Quidway-Vlanif10] ip address 1.1.1.1 24 [Quidway-Vlanif10] quit

    Log in to the FTP server (the switch).

    Assume that the Windows XP operating system is used.

    . Choose d press Enter. Enter FTP 1.1.1.1. Enter the user name at the user

    nter. The following n is displayed:

    \>ftp 1.1.1.1 ted to 1.1.1.1.

    220 FTP service ready.

    331 Password required for 1.

    230 User logged in. ftp>

    5. Uploa the switch.

    the FTP client to upload m software is uploaded to the switch, run the bye command to

    2-V100R006C00SPC800.CC

    -V100R006C00SPC800.CC.

    s sent in 60.40Seconds 140.76Kbytes/sec. ftp> bye 221 Server closing.

    D:\>

    Store the file to be uploaded in the specified directory (for example, D:\>directory)Start > Run. Enter cmd anprompt and the password at the password prompt, and then press Einformatio

    D:

    Connec

    User (1.1.1.2:(none)): ftpuser

    Password:

    d the system software to

    Run the put source-filename [ destination-filename ] command onthe system software. After systeclose the FTP connection and return to the user view.

    ftp> put D:\S375200 Port command okay. 150 Opening BINARY mode data connection for S3752226 Transfer complete. ftp: 8742812 byte

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    41

    6. Specify th uploaded software as the next startup software.

    startup system-software S3752-V100R006C00SPC800.CC all

    If the following information is displayed after you run the startup system-software file command, enter y to upgrade the BootROM.

    Warning: Basic BOOTROM will be upgraded. Continue?(Y/N)[N]: y e upgraded ! please wait for a moment

    ooting system on 0.

    C800.cc to

    booting system on 1.

    7.

    BOOTROM begin to b

    Info: BOOTROM UPGRADE OK Info: Succeeded in setting the software for b100% complete\ Info: Copied file flash:/S3752-V100R006C00SPslot1#flash:/S3752-V100R006C00SPC800.cc...Done. Info: Succeeded in setting the software for

    Restart the switch.

    After the software is upgraded to V100R006C00SPC800, you must specify the system software for next startup. If the system software is not specified or the invalid software is specified, the device will fail to restart. For details about specifying the system software for next startup, see step 5.

    When the system asks you whether to save the configuration, enter y or n. After the setting is

    Info: The system is now comparing the configuration, please wait. g: All the configuration will be saved to the configuration file for the next p:flash:/vrpcfg.zip, Continue?[Y/N]:y

    Now saving the current configuration to the slot 0.

    Info: Save the configuration successfully.

    ----E

    5.2 Using the Intelligent Upgrade Function

    5.2.1 Overview

    el rades or rolls back the system software of a new itch.

    complete, enter y to restart the system.

    reboot

    Warninstartu

    Info: Save the configuration successfully. Now saving the current configuration to the slot 1.

    System will reboot! Continue?[Y/N]: y

    Info: system is rebooting, please wait

    nd

    Int ligent upgrade is a function that automatically upg member switch to the version of the master sw

    A stack system is established only when all the following requirements are met:

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    42

    z All the member switches use the same software version. If the master switch detecdifferent software version on the new member switch, it upgrades or rolls back thesoftware of

    ts a

    the new member switch to the version of the stack.

    ports a maximum of eight switches in a stack system. The other S3700 models and the up to nine switches in a stack system.

    z s

    z

    z ing function is enabled on all the member switches.

    he stack processes version upgrade and rollback for new member switches in the same way.

    5.2.2 Upgrading a N ber Switch Using the Intelligent Upgrade Function

    Preparations for

    Be

    z

    z nnected to other member switches by using stack cables

    z bled by

    The S3752 supS5700 support

    The S3752 and S3728 cannot be added to the same stack system.

    All the member switches belong to the same series. That is, the EI series and SI seriecannot form a stack.

    z All the member switches are connected by using stack cables and stack modules.

    All the member switches are working properly.

    The stack

    T

    ew Mem

    Upgrade

    fore upgrading a new member switch of a stack, ensure that:

    The new member switch and the current stack members belong to the same series.

    The new member switch is coand stack modules.

    The stacking function is enabled on the new member switch. (This function is enadefault.)

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    43

    z If the flash memory of the new member switch does not have sufficient space to store the

    startup software package, the switch automatically deletes a software package to free up tch is an S5700, it deletes a non-startup software package. If the switch

    is an S3700, it deletes the current startup software package. If the available space in the switch restarts repeatedly. In

    this case, upgrade the software of the switch to the version of the stack system manually, re, see chapter 4 Upgrade

    itch.

    z During the upgrade, ensure that the stack cables are functioning properly. If the upgrade of

    the space. If the swi

    flash memory is still insufficient for the upgrade software, the

    and then add the switch to the stack. For the upgrade proceduOperations on a Single Sw

    a switch fails, upgrade the system software of the switch to the version of the stack manually, and then add the switch to the stack.

    Upgrade Process

    On the master switch:

    In Stack, device 0 load to new device 1 .......... start

    In Stack, device 0 load to new device 1 .......... success

    On the new member switch:

    The Software Version is Low.Version is V100R006C00! 100% completed In Stack, device 0 load flash:/S5700EI-V100R006C00SPC800.CC to new device 1(self) ... Success

    Starting upgrade BOOTROM .............. Pass

    Device starting reset.

    If the flash memory of the new member switch does not have sufficient space for the upgrade software, the following information is displayed:

    On the master switch:

    In Stack, device 0 load to new device 1 .......... start

    In Stack, device 0 load to new device 1 .......... fail

    On the new member switch:

    In Stack, upgrading from slot 4 to slot 0(self) .......... start Info: Free space is not enough. Auto deleting file ....

    Start the new member switch.

    The master switch of the stack automatically upgrades the new switch. If the upgrade is successful, the following information will be displayed:

  • Quidway S2700/S3700/S5700/S6700 Series Ethernet Switches Upgrade Guide 5 Upgrade Operations on a Stack

    Issue 01 (2011-09-30) Huawei Proprietary and Confidential Copyright Huawei Technologies Co., Ltd

    44

    ................................................................................

    ........................... success