Quick Start Guide for 3i BellaTek Encode Impression System · Encode placement. Save successfully...

2
1. Pre-Scan Preparation • If this is the first time you are scanning a BellaTek Encode Healing Abutment, please call 3M ESPE Customer Care to activate the workflow at 1-800-634-2249. Then, sync labs by selecting Home > Management > Lab > Sync All. • When entering patient information, use only patient initials for data privacy protection. BIOMET 3i will not accept full patient names. • Ensure the BellaTek Encode Healing Abutment is fully seated on the implant with a radiograph. The Healing Abutment must be at least 1mm supragingival for the information to be captured correctly. 2. Use Appropriate Amount of Powder • Sufficient powder is essential for data capture. The reflective surface of the BellaTek Encode Healing Abutment distal and mesial areas must be covered in order to prevent an incomplete scan. • Verify that the surface features and the screw head is not obscured. 3. Scanning Workflow • Begin the scan on the occlusal side of the adjacent tooth to the BellaTek Encode Healing Abutment and continue scanning the healing abutment and contact walls of the adjacent teeth, making sure to capture complete scan data. • Review the image(s) to ensure the BellaTek Encode Healing Abutment and contacts are completely captured. • Scan the remainder of the operative quad/arch, the opposing arch and bite. As with the typical workflow, review implant images in high resolution. Select the correlating tooth number to the position of the BellaTek Encode placement. Save successfully scanned implants by selecting the green check. 4. Enter the Prescription • Select the Rx tab on the scan screen to display the prescription screen. • Request a delivery date. • Select the desired Restorative Lab. • Verify that the system has the correct dentist assigned to the case. Steps to Complete a Case 1 2 3 3M True Definition Scanner Quick Start Guide for BIOMET 3i BellaTek Encode ® Impression System 4

Transcript of Quick Start Guide for 3i BellaTek Encode Impression System · Encode placement. Save successfully...

Page 1: Quick Start Guide for 3i BellaTek Encode Impression System · Encode placement. Save successfully scanned implants by selecting the green check. 4. Enter the Prescription • Select

1. Pre-Scan Preparation

• If this is the first time you are scanning a BellaTek Encode Healing Abutment, please call 3M ESPE Customer Care to activate the workflow at 1-800-634-2249. Then, sync labs by selecting Home > Management > Lab > Sync All.

• When entering patient information, use only patient initials for data privacy protection. BIOMET 3i will not accept full patient names.

• Ensure the BellaTek Encode Healing Abutment is fully seated on the implant with a radiograph. The Healing Abutment must be at least 1mm supragingival for the information to be captured correctly.

2. Use Appropriate Amount of Powder

• Sufficient powder is essential for data capture. The reflective surface of the BellaTek Encode Healing Abutment distal and mesial areas must be covered in order to prevent an incomplete scan.

• Verify that the surface features and the screw head is not obscured.

3. Scanning Workflow

• Begin the scan on the occlusal side of the adjacent tooth to the BellaTek Encode Healing Abutment and continue scanning the healing abutment and contact walls of the adjacent teeth, making sure to capture complete scan data.

• Review the image(s) to ensure the BellaTek Encode Healing Abutment and contacts are completely captured.

• Scan the remainder of the operative quad/arch, the opposing arch and bite. As with the typical workflow, review implant images in high resolution. Select the correlating tooth number to the position of the BellaTek Encode placement. Save successfully scanned implants by selecting the green check.

4. Enter the Prescription

• Select the Rx tab on the scan screen to display the prescription screen.

• Request a delivery date.

• Select the desired Restorative Lab.

• Verify that the system has the correct dentist assigned to the case.

Steps to Complete a Case

1

2

3

3M™ True Definition ScannerQuick Start Guide for BIOMET 3i™ BellaTek™ Encode® Impression System

4

Page 2: Quick Start Guide for 3i BellaTek Encode Impression System · Encode placement. Save successfully scanned implants by selecting the green check. 4. Enter the Prescription • Select

8. Complete the Prescription

• Select the Sign button to display the Rx Digital Signature Screen.

• Enter your PIN to complete the prescription.

6. Design the Abutment

• Touch the 00 Biomet 3i Facility line and select the correct BIOMET 3i Manufacturing Facility (U.S. or Europe).

Note: This step must be completed or the case will not be processed.

• Complete lines 01–12 to set the design parameters and desired material for the abutment. If no design parameters are selected, BIOMET 3i will use standard default settings.

• Line 13 Design File Check and Approval allows you to request abutment design approval from the doctor, lab or none before milling.

5. Enter the Prescription (cont.)

• Follow the screen prompt and touch to select restoration.

• Select the BIOMET Implant Abutment as restoration type and choose the tooth number from the chart.

Note: If BIOMET Implant Abutment is NOT selected, the case will not be processed as an implant case.

Note: If (red ! symbol) is present, the data plan does not include Biomet implant abutments. The process can be prescribed but an additional cost will be charged to the account. Contact 3M ESPE Customer Care Center at 1-800-634-2249 to update data plan if desired.

7. Design the Restoration

• To specify the restoration type (crown or bridge) for the abutment, select Add Restoration button on the lower right corner as shown to the right.

• Select the restoration type.

• Follow the on-screen instructions and review the information.

• Use the Notes field for any special requests. If implant abutment screws are needed, please request them here.

Tip: Use the Add Restoration button to provide the laboratory with information about the desired restoration type, materials, shade selections and other options.

Tip: When scanning multiple implants, Steps 6 and 7 need to be repeated for each implant.

REV B 01/13

Steps to Complete a Case (cont.)

BIOMET 3i LLC Global Headquarters

4555 Riverside DrivePalm Beach Gardens, FL 334101-800-342-5454Outside the U.S.: +1-561-776-6700Fax: +1-561-776-1272www.biomet3i.com

Customer Care Center: 1-800-634-2249 www.3M.com/TrueDef

3M and BIOMET 3i LLC Customer Support

3M ESPE Customer Care Center: 1-800-634-2249for 3M™ True Definition Scanner, 3M™ Connection Center and 3M Software questions and support

BIOMET 3i LLC: 1-888-800-8045for BIOMET 3i abutment design, manufacturing and restoration fit support

3M is a trademark of 3M. Used under license in Canada. Please recycle. Printed in U.S.A. Encode is a registered trademark, BellaTek is a trademark of BIOMET 3i LLC. BIOMET 3i is a trademark of BIOMET Inc.

© 3M 2015. All rights reserved. 70-2013-0552-4 (Rev. 8/2015)

3M CanadaPost Office Box 5757London, Ontario N6A 4T1Canada1-888-363-3685

3M Oral Care2510 Conway AvenueSt. Paul, MN 55144-1000 USA

Phone 1-800-634-2249 Web www.3M.com/TrueDef

8

6

5 7