Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process...

16
Quick setup guide Pressure transmitter with metallic measuring cell VEGABAR 83 4 … 20 mA Document ID: 46312

Transcript of Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process...

Page 1: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

Quick setup guidePressure transmitter with metallic measuring cell

VEGABAR 834 … 20 mA

Document ID: 46312

Natalie Lundie
HP Stamp
Page 2: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

2

Contents

VEGABAR 83 • 4 … 20 mA

46312-EN-160212

Contents1 For your safety

1.1 Authorised personnel ....................................................................................................... 31.2 Appropriate use ................................................................................................................ 31.3 Warning about incorrect use ............................................................................................. 31.4 General safety instructions ............................................................................................... 31.5 CE conformity ................................................................................................................... 31.6 Permissible process pressure .......................................................................................... 41.7 NAMUR recommendations .............................................................................................. 41.8 Environmental instructions ............................................................................................... 4

2 Product description2.1 Configuration .................................................................................................................... 5

3 Mounting3.1 General instructions for use of the instrument .................................................................. 63.2 Ventilation and pressure compensation ............................................................................ 6

4 Connecting to power supply4.1 Connecting ....................................................................................................................... 74.2 Single chamber housing ................................................................................................... 8

5 Set up with the display and adjustment module5.1 Insert display and adjustment module .............................................................................. 95.2 Parameter adjustment - Quick setup ................................................................................ 95.3 Parameter adjustment - Extended adjustment................................................................ 11

6 Supplement6.1 Technical data ................................................................................................................ 14

Information:This quick setup guide enables quick setup and commissioning of your instrument.Youcanfindsupplementaryinformationinthecorresponding,moredetailed Operating Instructions Manual as well as the Safety Manual thatcomeswithinstrumentswithSILqualification.Thesemanualsareavailable on the supplied DVD or in the download area of "www.vega.com".

Operating instructions VEGABAR 83 - 4 … 20 mA: Document-ID 45033Editing status of the quick setup guide: 2016-02-04

Page 3: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

3

1 For your safety

VEGABAR 83 • 4 … 20 mA

4631

2-EN

-160

212

1 For your safety

1.1 Authorised personnelAll operations described in this operating instructions manual must be carried out only by trained specialist personnel authorised by the plant operator.During work on and with the device the required personal protective equipment must always be worn.

1.2 Appropriate useThe VEGABAR 83 is a pressure transmitter for process pressure and hydrostatic level measurement.Youcanfinddetailedinformationabouttheareaofapplicationinchapter "Product description".Operational reliability is ensured only if the instrument is properly usedaccordingtothespecificationsintheoperatinginstructionsmanual as well as possible supplementary instructions.

1.3 Warning about incorrect useInappropriate or incorrect use of the instrument can give rise to application-specifichazards,e.g.vesseloverfillordamagetosystemcomponents through incorrect mounting or adjustment. Also the pro-tectivecharacteristicsoftheinstrumentcanbeinfluenced.

1.4 General safety instructionsThis is a high-tech instrument requiring the strict observance of stand-ard regulations and guidelines. The user must take note of the safety instructionsinthisoperatinginstructionsmanual,thecountry-specificinstallation standards as well as all prevailing safety regulations and accident prevention rules.Theinstrumentmustonlybeoperatedinatechnicallyflawlessandreliable condition. The operator is responsible for trouble-free opera-tion of the instrument.Duringtheentiredurationofuse,theuserisobligedtodeterminethecompliance of the necessary occupational safety measures with the current valid rules and regulations and also take note of new regula-tions.

1.5 CE conformityThedevicefulfillsthelegalrequirementsoftheapplicableECguide-lines.ByaffixingtheCEmarking,weconfirmsuccessfultestingoftheproduct.YoucanfindtheCECertificateofConformityinthedownloadsectionof our homepage.

Page 4: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

4

1 For your safety

VEGABAR 83 • 4 … 20 mA

46312-EN-160212

1.6 Permissible process pressureThepermissibleprocesspressureisspecifiedonthetypelabelwith"Processpressure",seechapter"Configuration".Forsafetyreasons,this range may not be exceeded. This applies even if a measuring cell with a measuring range (order-related) higher than the permissible pressurerangeoftheprocessfittingisinstalled.

1.7 NAMUR recommendationsNAMUR is the automation technology user association in the process industry in Germany. The published NAMUR recommendations are acceptedasthestandardinfieldinstrumentation.ThedevicefulfillstherequirementsofthefollowingNAMURrecom-mendations:

• NE 21 – Electromagnetic compatibility of equipment• NE 43 – Signal level for malfunction information from measuring

transducers• NE53–Compatibilityoffielddevicesanddisplay/adjustment

components• NE107–Self-monitoringanddiagnosisoffielddevicesFor further information see www.namur.de.

1.8 Environmental instructionsProtection of the environment is one of our most important duties. That is why we have introduced an environment management system with the goal of continuously improving company environmental pro-tection.Theenvironmentmanagementsystemiscertifiedaccordingto DIN EN ISO 14001.Pleasehelpusfulfillthisobligationbyobservingtheenvironmentalinstructions in this manual:

• Chapter "Packaging, transport and storage"• Chapter "Disposal"

Page 5: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

5

2 Product description

VEGABAR 83 • 4 … 20 mA

4631

2-EN

-160

212

2 Product description

2.1 ConfigurationThetypelabelcontainsthemostimportantdataforidentificationanduse of the instrument:

21

13

14

12

10

11

5

3

6

4

78

9

Fig. 1: Layout of the type label (example)1 Instrument type2 Product code3 Field for approvals4 Power supply and signal output, electronics5 Protection rating6 Measuring range7 Permissible process pressure8 Material, wetted parts9 Order number10 Serial number of the instrument11 Data-Matrix-Code for smartphone app12 Symbol of the device protection class13 ID numbers, instrument documentation14 Reminder to observe the instrument documentation

The type label contains the serial number of the instrument. With it youcanfindthefollowinginstrumentdataonourhomepage:

• Product code (HTML)• Delivery date (HTML)• Order-specificinstrumentfeatures(HTML)• Operating instructions and quick setup guide at the time of ship-

ment (PDF)• Order-specificsensordataforanelectronicsexchange(XML)• Testcertificate(PDF)-optionalGo to www.vega.com "VEGA Tools" and "Instrument search". Enter the serial number.Alternatively,youcanaccessthedataviayoursmartphone:

• Download the smartphone app "VEGA Tools" from the "Apple App Store" or the "Google Play Store"

• Scan the Data Matrix code on the type label of the instrument or• Enter the serial number manually in the app

Type label

Serial number - Instru-ment search

Page 6: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

6

3 Mounting

VEGABAR 83 • 4 … 20 mA

46312-EN-160212

3 Mounting

3.1 General instructions for use of the instrumentProtect your instrument against moisture ingress through the following measures:

• Use the recommended cable (see chapter "Connecting to power supply")

• Tighten the cable gland• Whenmountinghorizontally,turnthehousingsothatthecable

gland points downward• Loop the connection cable downward in front of the cable gland

Thisappliesmainlytooutdoorinstallations,inareaswherehumidityisexpected (e.g. through cleaning processes) and on cooled or heated vessels.

3.2 Ventilation and pressure compensationThefilterelementismountedintotheelectronicshousing.Ithasthefollowing functions:

• Ventilation of the electronics housing• Atmospheric pressure compensation (with relative pressure meas-

uring ranges)

→ Turnthehousingsothatthefilterelementpointsdownwardafterthe instrument is installed. This provides better protection against buildup.

1 2 3

4 4 4

Fig. 2: Position of the filter element - non-Ex, Ex-ia version1 Housing plastic, stainless steel precision casting2 Housing aluminium3 Housing stainless steel, electropolished4 Filter element

With the following instruments a blind plug is installed instead of the filterelement:

• InstrumentsinprotectionIP66/IP68(1bar)-ventilationviacapil-laries in non-detachable cable

• Instruments with absolute pressure

Protection against mois-ture

Instruments in non-Ex and Ex-ia version

Page 7: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

7

4 Connecting to power supply

VEGABAR 83 • 4 … 20 mA

4631

2-EN

-160

212

4 Connecting to power supply

4.1 ConnectingThe voltage supply and signal output are connected via the spring-loaded terminals in the housing.Connection to the display and adjustment module or to the interface adapter is carried out via contact pins in the housing.

Information:The terminal block is pluggable and can be removed from the electronics.Todothis,lifttheterminalblockwithasmallscrewdriverandpullitout.Whenreinsertingtheterminalblock,youshouldhearitsnap in.

Proceed as follows:1. Unscrew the housing lid2. Ifadisplayandadjustmentmoduleisinstalled,removeitbyturn-

ing it slightly to the left.3. Loosen compression nut of the cable gland and remove blind

plug4. Removeapprox.10cm(4in)ofthecablemantle,stripapprox.

1 cm (0.4 in) of insulation from the ends of the individual wires5. Insert the cable into the sensor through the cable entry

Fig. 3: Connection steps 5 and 6 - Single chamber housing

6. Insert the wire ends into the terminals according to the wiring plan

Information:Solidcoresaswellasflexiblecoreswithwireendsleevesareinsert-eddirectlyintotheterminalopenings.Incaseofflexiblecoreswithoutendsleeves,presstheterminalfromabovewithasmallscrewdriver,theterminalopeningisthenfree.Whenthescrewdriverisreleased,the terminal closes again.

Connection technology

Connection procedure

Page 8: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

8

4 Connecting to power supply

VEGABAR 83 • 4 … 20 mA

46312-EN-160212

Youcanfindfurtherinformationonthemax.wirecross-sectionunder"Technical data - Electromechanical data"

7. Check the hold of the wires in the terminals by lightly pulling on them

8. Connectthescreentotheinternalgroundterminal,connecttheexternal ground terminal to potential equalisation

9. Tighten the compression nut of the cable entry gland. The seal ring must completely encircle the cable

10. Reinsertthedisplayandadjustmentmodule,ifonewasinstalled11. Screw the housing lid back onTheelectricalconnectionisfinished.

4.2 Single chamber housingThe following illustration applies to the non-Ex as well as to the Ex-ia version.

51 2+( ) (-) 6 7 8

4...20mA

2

3

41

Fig. 4: Electronics and terminal compartment, single chamber housing1 Voltage supply/Signal output2 For display and adjustment module or interface adapter3 For external display and adjustment unit or Slave sensor4 Ground terminal for connection of the cable screen

Electronics and terminal compartment

Page 9: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

9

5 Set up with the display and adjustment module

VEGABAR 83 • 4 … 20 mA

4631

2-EN

-160

212

5 Set up with the display and adjustment module

5.1 Insert display and adjustment moduleThe display and adjustment module can be inserted into the sensor andremovedagainatanytime.Youcanchooseanyoneoffourdiffer-ent positions - each displaced by 90°. It is not necessary to interrupt the power supply.Proceed as follows:1. Unscrew the housing lid2. Place the display and adjustment module on the electronics in the

desired position and turn it to the right until it snaps in.3. Screw housing lid with inspection window tightly back onDisassembly is carried out in reverse order.Thedisplayandadjustmentmoduleispoweredbythesensor,anad-ditional connection is not necessary.

Fig. 5: Installing the display and adjustment module in the electronics compart-ment of the single chamber housing

Note:Ifyouintendtoretrofittheinstrumentwithadisplayandadjustmentmoduleforcontinuousmeasuredvalueindication,ahigherlidwithaninspection glass is required.

5.2 Parameter adjustment - Quick setupToquicklyandeasilyadaptthesensortotheapplication,selectthe menu item "Quick setup" in the start graphic on the display and adjustment module.

Page 10: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

10

5 Set up with the display and adjustment module

VEGABAR 83 • 4 … 20 mA

46312-EN-160212

Carry out the following steps in the below sequence.Youcanfind"Extended adjustment" in the next sub-chapter.

1. Measurement loop nameInthefirstmenuitemyouassignasuitablemeasurementloopname.Permitted are names with max. 19 characters.

2. ApplicationInthismenuitem,youactivate/deactivatetheslavefortheelectronicdifferentialpressureandselecttheapplication.Theapplicationcom-prises process pressure and level measurement.

3. UnitsIn this menu item you determine the adjustment and temperature units of the instrument. Depending on the selected application in the menu item "Application",differentadjustmentunitsareavailable.

4. Position correctionInthismenuitemyoucompensatetheinfluenceoftheinstallationpositionoftheinstrument(offset)onthemeasuredvalue.

5. Zero adjustmentInthismenuitemyoucarryoutthezeroadjustmentfortheprocesspressure.Enter the corresponding pressure value for 0 %.

6. Span adjustmentIn this menu item you carry out the span adjustment for the process pressureEnter the corresponding pressure value for 100 %.

4. Position correctionInthismenuitemyoucompensatetheinfluenceoftheinstallationpositionoftheinstrument(offset)onthemeasuredvalue.

5. Max. adjustmentIn this menu item you carry out the max. adjustment for levelEnter the percentage value and the corresponding value for the max. level.

Presettings

Quick setup - Process pressure measurement

Quick setup - Level meas-urement

Page 11: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

11

5 Set up with the display and adjustment module

VEGABAR 83 • 4 … 20 mA

4631

2-EN

-160

212

6. Min. adjustmentIn this menu item you carry out the min. adjustment for levelEnter the percentage value and the corresponding value for the min. level.

Thequicksetupisfinished.

5.3 Parameter adjustment - Extended adjustmentFortechnicallydemandingmeasuringpoints,youcancarryoutextended settings in "Extended adjustment".

Themainmenuisdividedintofivesectionswiththefollowingfunc-tions:

Setup:Settings,e.g.,formeasurementloopname,application,units,positioncorrection,adjustment,signaloutputDisplay:Settings,e.g.,forlanguage,measuredvaluedisplay,lightingDiagnosis:Information,e.g.oninstrumentstatus,pointer,measure-mentreliability,simulationAdditional adjustments:PIN,date/time,reset,copyfunctionInfo:Instrumentname,hardwareandsoftwareversion,dateofmanu-facture,sensorfeatures

Note:Foroptimumadjustmentofthemeasuringpoint,theindividualsub-menu items in the main menu item "Setup" should be selected one aftertheotherandprovidedwiththecorrectparameters.Ifpossible,go through the items in the given sequence.The procedure is described below.

The following submenu points are available:

The submenu points described below.

Main menu

Page 12: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

12

5 Set up with the display and adjustment module

VEGABAR 83 • 4 … 20 mA

46312-EN-160212

Menu - Setup

Menu item Parameter Default setting

Measurement loop name

Sensor

Application Application level

Units Unit of measure-ment

mbar (with nominal measuring range ≤400mbar)bar (with nominal measuring rang-es≥1bar)

Temperature unit °C

Position correc-tion

0.00 bar

Adjustment Zero/Min.adjust-ment

0.00 bar0.00 %

Span/Max.adjust-ment

Nominal measuring range in bar100.00 %

Damping Integration time 0.0 s

Linearization Characteristics Linear

Current output Current output - Mode

Output characteristics4 … 20 mAReaction when malfunctions occur≤3.6mA

Current output - Min./Max.

3.8 mA20.5 mA

Lock adjustment Released

Menu - Display

Menu item Default setting

Menu language Order-specific

Displayed value 1 Current output in %

Displayed value 2 Ceramic measuring cell: Measuring cell tempera-ture in °CMetallic measuring cell: Electronics temperature in °C

Display format 1 and 2 Numberofpositionsafterthedecimalpoint,auto-matically

Backlight Switched on

Menu - Diagnosis

Menu item Parameter Default setting

Sensor status -

Menu and parameter overview

Page 13: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

13

5 Set up with the display and adjustment module

VEGABAR 83 • 4 … 20 mA

4631

2-EN

-160

212

Menu item Parameter Default setting

Peak value Pressure Actual measured value

Temperature Actual temperature values from meas-uringcell,electronics

Simulation Pressure

Menu - Additional adjustments

Menu item Parameter Default setting

PIN 0000

Date/Time Actualdate/Actualtime

Reset -

Copy in-strument settings

-

Special pa-rameters

-

Scaling Scalingsize Volume in l

Scaling format 0 % corresponds to 0 l100 % corresponds to 0 l

Current out-put 1

Current output - Meas. vari-able

Lin. percent - Level

Current output - Adjustment 0 … 100 % correspond to 4 … 20 mA

Current out-put 2

Current output - Meas. vari-able

Measuring cell temperature (ceramic measuring cell)

Current output - Adjustment 0 … 100 °C correspond to 4 … 20 mA

Menu - Info

Menu item Parameter

Device name VEGABAR 8.

Instrument version Hardware and software version

Factory calibration date

Date

Sensor characteristics Order-specificcharacteristics

Page 14: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

14

6 Supplement

VEGABAR 83 • 4 … 20 mA

46312-EN-160212

6 Supplement

6.1 Technical dataElectromechanical data - version IP 66/IP 67 and IP 66/IP 68; 0.2 barCable entry

Ʋ M20 x 1.5 1xcableglandM20x1.5(cable:ø6…12mm),1xblind plug M20 x 1.5

Ʋ ½ NPT 1xblindplugNPT,1xclosingcap(red)½NPTWire cross-section (spring-loaded terminals)

Ʋ Massivewire,strandedwire 0.2 … 2.5 mm² (AWG 24 … 14) Ʋ Stranded wire with end sleeve 0.2 … 1.5 mm² (AWG 24 … 16)

Voltage supplyOperating voltage UB

Ʋ Non-Ex instrument 9.6 … 35 V DC Ʋ Ex-d instrument 9.6 … 35 V DC Ʋ Ex ia instrument 9.6 … 30 V DC Ʋ Ex-d-ia instrument 15 … 35 V DC Ʋ Ex-d-ia instrument with ship approval 15 … 35 V DC

Operating voltage UB - illuminated display and adjustment module Ʋ Non-Ex instrument 16 … 35 V DC Ʋ Ex-d instrument 16 … 35 V DC Ʋ Ex ia instrument 16 … 30 V DC Ʋ Ex-d-ia instrument No lighting (integrated ia barrier)

Reverse voltage protection IntegratedPermissibleresidualripple-Non-Ex,Ex-iainstrument

Ʋ for UN 12 V DC (9.6 V< UB < 14 V) ≤0.7Veff(16…400Hz) Ʋ for UN 24 V DC (18 V< UB < 35 V) ≤1.0Veff(16…400Hz)

Permissible residual ripple - Ex-d-ia instrument Ʋ for UN 24 V DC (18 V< UB < 35 V) ≤1Veff(16…400Hz)

Load resistor Ʋ Calculation (UB - Umin)/0.022A Ʋ Example - Non-Ex instrument with UB= 24 V DC

(24V-9.6V)/0.022A=655Ω

Page 15: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

15

Notes

VEGABAR 83 • 4 … 20 mA

4631

2-EN

-160

212

Page 16: Quick setup guide - Heating and Process...1.6 Permissible process pressure The permissible process pressure is specified on the type label with "Process pressure", see chapter "Configuration".orety

Printing date:

VEGA Grieshaber KGAm Hohenstein 11377761 SchiltachGermany

4631

2-E

N-1

6021

2

All statements concerning scope of delivery, application, practical use and operat-ing conditions of the sensors and processing systems correspond to the information available at the time of printing.Subject to change without prior notice

© VEGA Grieshaber KG, Schiltach/Germany 2016

Phone +49 7836 50-0Fax +49 7836 50-201E-mail: [email protected]

Natalie Lundie
HP Stamp