Quick fieldreport - EMSC

59
Lorca earthquake 11th May 2011 Quick field report Patrick Murphy Corella Director of Architecture Broadway Malyan Calle Julián Camarillo 42, 4º 28037 Madrid T (+34) 91 375 05 49 M(+34) 675 89 43 00 [email protected]

Transcript of Quick fieldreport - EMSC

Page 1: Quick fieldreport - EMSC

Lorca earthquake 11th May 2011

Quick field reportPatrick Murphy Corella

Director of Architecture

Broadway Malyan

Calle Julián Camarillo 42, 4º

28037 Madrid

T (+34) 91 375 05 49

M(+34) 675 89 43 00

[email protected]

Page 2: Quick fieldreport - EMSC

BASIC EARTHQUAKE PARAMETERS

Mw 5,1 at 16:47 UTC 11th May 2011 N 37,69 W 1,67 very superficial focus

5,1 MW

0,42g HORIZONTAL COMPONENT

REGISTERED BY IGN STRONG MOTION

NETWORK IN LORCA

Page 3: Quick fieldreport - EMSC

Summary of observed

building performance

Page 4: Quick fieldreport - EMSC

Standard dwelling building in Lorca

MRF moment frame

Flat slabs (no beam downhangs)

Commercial use onground floor (higherclear height bymunicipal order)

dwellings

Page 5: Quick fieldreport - EMSC

We assume it will perform like this6

Page 6: Quick fieldreport - EMSC

But it is conditioned by masonry infill panels and a soft ground floor6

Page 7: Quick fieldreport - EMSC

And it behaves like this.

Severe deformationon ground floors

Page 8: Quick fieldreport - EMSC

And is damaged like this

Page 9: Quick fieldreport - EMSC

STATIC BUILDINGS

A widespread static approach tobuilding concept is observed6

Page 10: Quick fieldreport - EMSC

SOMOS ESTÁTICOS

All buildings ovserved were moment frames

No shear walls, no bracing,

Page 11: Quick fieldreport - EMSC

SOMOS ESTÁTICOS

No soft storey corrections were observed in any buildings

Page 12: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001Typical damage

Page 13: Quick fieldreport - EMSC

SEVERE DEFORMATION ON GROUND FLOOR SOFT STOREYS

Page 14: Quick fieldreport - EMSC

SEVERE DEFORMATION ON GROUND FLOOR SOFT STOREYS

Page 15: Quick fieldreport - EMSC

EXPELLED MASONRY PANELS

POUNDING DAMAGE

Page 16: Quick fieldreport - EMSC

SHEAR FALIURE ON COLUMN HEADS

Page 17: Quick fieldreport - EMSC

SHEAR FALIURE ON COLUMN HEADS- INADEQUATE LOOPING

Page 18: Quick fieldreport - EMSC

SHEAR FALIURE ON COLUMN HEADS- INADEQUATE LOOPING

Page 19: Quick fieldreport - EMSC

SHEAR FALIURE ON COLUMN HEADS- INADEQUATE LOOPING

Page 20: Quick fieldreport - EMSC

SHEAR DAMAGE ON LIFT SHEAR WALL

Page 21: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001

SHORT COLUMNS KILL PEOPLE

Page 22: Quick fieldreport - EMSC

‘PANCAKE COLLAPSE’

Page 23: Quick fieldreport - EMSC

NEIGHBOURING TWIN BUILIDING GIVES US A CLUE AS TO THE COLLAPSE MECHANISM – SHORT COLUMNS

Page 24: Quick fieldreport - EMSC

A STATIC BUILDING – SHORT COLUMNS EMERGING FROM BASEMENT

Page 25: Quick fieldreport - EMSC

PERIMETER SHORT COLUMNS ARE VERY STIFF AND ATTRACT ALL SHEAR FORCE

Page 26: Quick fieldreport - EMSC

CRUSHED SHORT COLUMNS CAUSE BUILDILNG FAILURE

Page 27: Quick fieldreport - EMSC

NEIGHBOUR IS ALMOST KNOCKED DOWN TOO

Page 28: Quick fieldreport - EMSC

THANK GOD THERE HAD BEEN A 4,5 EVENT BEFORE AND PEOPLE HAD LEFT THE BUILDING

Page 29: Quick fieldreport - EMSC

INADEQUATE HOOP CONFINEMENT

Page 30: Quick fieldreport - EMSC

DAMAGED SHORT COLUMNS EVERYWHERE

Page 31: Quick fieldreport - EMSC

CAPTURED COLUMN MADE SHORT BY MASONRY INTERACTION

Page 32: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001

PLAZA DE LOS APRENDICES – THE RED BUILDING

Page 33: Quick fieldreport - EMSC

SEVERELY DEFORMED GROUND FLOOR

Page 34: Quick fieldreport - EMSC

BUILDING LISTING TO THE NORTH

Page 35: Quick fieldreport - EMSC

GROUND FLOOR COLUMN FAILURES

Page 36: Quick fieldreport - EMSC

GEOTECHNICAL FAILURE?

Page 37: Quick fieldreport - EMSC

IT FELL DOWN BY ITSELF

Page 38: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001

NON-STRUCTURAL ELEMENTS KILL PEOPLE

Page 39: Quick fieldreport - EMSC

EXPELLED MASONRY PANELS KILL PEOPLE

Page 40: Quick fieldreport - EMSC

UNREINFORCED PARAPETS KILL PEOPLE

Page 41: Quick fieldreport - EMSC

UNREINFORCED PARAPETS EVERYWHERE

Page 42: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001

WHERE ARE THE SEISMIC JOINTS?

Page 43: Quick fieldreport - EMSC

A THERMAL JOINT IS NOT A SEISMIC JOINT

Page 44: Quick fieldreport - EMSC

EARTHQUAKE – INDUCED JOINTING

Page 45: Quick fieldreport - EMSC

SWAYING AND POUNDING

0,5M

Page 46: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001

TERRIBLE DAMAGE TO HERITAGE

Page 47: Quick fieldreport - EMSC

OUT OF PLANE COLLAPSE OF TRAIN STATION MASONRY BEARING WALL

Page 48: Quick fieldreport - EMSC

SANTIAGO CHURCH NAVE COLLAPSE

Page 49: Quick fieldreport - EMSC

SANTIAGO CHURCH NAVE COLLAPSE

Page 50: Quick fieldreport - EMSC

SANTIAGO CHURCH BUTRESS DAMAGE

Page 51: Quick fieldreport - EMSC

PASO AZUL CHURCH HANGING KEYSTONE

Page 52: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001

INTERIORS

Page 53: Quick fieldreport - EMSC

HEAVY DAMAGE TO PERISHABLE GOODS

Page 54: Quick fieldreport - EMSC

OBJECTS THROWN TO THE FLOOR IN LARGE NUMBERS (EMS 7)

Page 55: Quick fieldreport - EMSC

MONUMENT ROTATION

Page 56: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001

THERE IS GOOD NEWS

Page 57: Quick fieldreport - EMSC

HIGH RISE WITH CONCRETE PARAPETS AND SHEAR RESISTANT COLUMNS – NO DAMAGE

LIGHT METAL CLADDING – NO DAMAGE

Page 58: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001

CONCLUSIONS

Page 59: Quick fieldreport - EMSC

TERREMOTO DE LORCA 12 MAYO 2001

LACK OF STIFFNESS IN SMALL TO MEDIUM SIZED

MIXED USE BUILDINGS

BUILDINGS ARE STILL BEING CONCEIVED

STATICALLY

SEVERE MASONRY – STRUCTURE INTERACTION

AND INTERFERENCE

POOR SEISMIC DESIGN IN THE CONCEPTUAL

PHASE OF BUILDING LAYOUT

1234

SHORT COLUMNS KILL PEOPLE5NON – STRUCTURAL ELEMENTS KILL PEOPLE6