Quectel Cellular Engine€¦ · FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -12 - Figure 7: UI of Set New...
Transcript of Quectel Cellular Engine€¦ · FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -12 - Figure 7: UI of Set New...
U10 Quectel Cellular Engine
Firmware Upgrade
Tool Advanced
User Guide FW_Upgrade_Tool_Advanced_UGD_V1.0
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -1 -
General Notes
Quectel offers this information as a service to its customers, to support application and
engineering efforts that use the products designed by Quectel. The information provided is
based upon requirements specifically provided to Quectel by the customers. Quectel has not
undertaken any independent search for additional relevant information, including any
information that may be in the customer’s possession. Furthermore, system validation of this
product designed by Quectel within a larger electronic system remains the responsibility of
the customer or the customer’s system integrator. All specifications supplied herein are
subject to change.
Copyright
This document contains proprietary technical information which is the property of Quectel
Limited. The copying of this document, distribution to others, and communication of the
contents thereof, are forbidden without express authority. Offenders are liable to the payment
of damages. All rights are reserved in the event of a patent grant or registration of a utility
model or design. All specification supplied herein are subject to change without notice at any
time.
Copyright © Quectel Wireless Solutions Co., Ltd. 2012
Document Title Firmware Upgrade Tool Advanced WS1 User Guide
Version 1.0
Date 2012-04-28
Status Released
Document Control ID Firmware_Upgrade_Tool_Advanced_WS1_V1.0
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -2 -
Contents
Contents ............................................................................................................................................ 2
Figure Index ...................................................................................................................................... 3
0. Revision history ............................................................................................................................ 4
1. Introduction ................................................................................................................................... 5
2. Tool installation ............................................................................................................................. 6
3. Firmware ....................................................................................................................................... 7
4. Introduction to the tool .................................................................................................................. 8
4.1. UI settings ........................................................................................................................... 9
4.1.1. Port configuration ...................................................................................................... 9
4.1.2. Files setting ............................................................................................................. 10
4.1.3. Database file setting ................................................................................................ 11
4.1.4. Operation option ...................................................................................................... 12
4.2. Firmware upgrade ............................................................................................................. 13
4.2.1. Backup system data ................................................................................................. 13
4.2.2. Download FW and format ....................................................................................... 16
4.2.3. Restore system data ................................................................................................. 18
4.2.4. Stop ......................................................................................................................... 19
4.3. Abnormalities .................................................................................................................... 19
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -3 -
Figure Index
FIGURE 1: THE MAIN INTERFACE ..................................................................................................... 8
FIGURE 2: UI OF PORT ......................................................................................................................... 9
FIGURE 3: UI OF BAUD RATE ........................................................................................................... 10
FIGURE 4: UI OF CFG FILE: FILE OPEN WINDOW ........................................................................ 10
FIGURE 5: UI OF CFG FILE SELECTED ........................................................................................... 11
FIGURE 6: UI OF SET OLD FILE WINDOW OPEN .......................................................................... 11
FIGURE 7: UI OF SET NEW FILE WINDOW OPEN ......................................................................... 12
FIGURE 8: UI OF OPERATE OPTION ................................................................................................ 13
FIGURE 9: BACKUP SYSTEM DATA-1 ............................................................................................. 14
FIGURE 10: BACKUP SYSTEM DATA-2 ........................................................................................... 15
FIGURE 11: BACKUP SYSTEM DATA-3 ........................................................................................... 15
FIGURE 12: DOWNLOAD FW AND FORMAT-1 ............................................................................... 16
FIGURE 13: DOWNLOAD FW AND FORMAT-2 ............................................................................... 16
FIGURE 14: DOWNLOAD FW AND FORMAT-3 ............................................................................... 17
FIGURE 15: DOWNLOAD FW AND FORMAT-4 ............................................................................... 17
FIGURE 16: RESTORE SYSTEM DATA ............................................................................................. 18
FIGURE 17: SELECT THE BACKUP FILE FROM STEP BACKUP SYSTEM DATA ...................... 18
FIGURE 18: RESTORE SYSTEM DATA SUCCESS ........................................................................... 19
FIGURE 19: UI OF BLANK PORT ERROR ........................................................................................ 20
FIGURE 20: UI OF BUSY PORT ERROR ............................................................................................ 20
FIGURE 21: UI OF BAUD RATE ERROR ........................................................................................... 21
FIGURE 22: UI OF UPGRADE WITH INCORRECT CFG FILE ........................................................ 21
FIGURE 23: UI OF BACKUP SYSTEM DATA ERROR WHEN CANCEL TO SAVE FILE ........... 22
FIGURE 24: UI OF RESTORE SYSTEM DATA ERROR WHEN CANCEL TO SAVE DATA .......... 22
FIGURE 25: UI OF BACKUP SYSTEM DATA ERROR WHEN POWER SUPPLY ABNORMAL ... 23
FIGURE 26: UI OF POWER SUPPLY OR USB ABNORMAL IN DA PROCESS .............................. 23
FIGURE 27: UI OF POWER SUPPLY OR USB ABNORMAL IN DOWNLOAD PROCESS ............ 24
FIGURE 28: UI OF POWER SUPPLY ABNORMAL IN FORMAT PROCESS .................................. 24
FIGURE 29: UI OF USB ABNORMAL IN RESTORE SYSTEM DATA PROCESS........................... 25
FIGURE 30: UI OF POWER SUPPLY OR USB ABNORMAL WHEN READ SYSTEM DATA TO
TERMINAL ..................................................................................................................... 25
FIGURE 31: UI OF ERROR WHEN FAIL TO SAVE SYSTEM DATA ............................................... 26
FIGURE 32: UI OF ERROR WHEN FAIL TO RESTORE SYSTEM DATA ....................................... 26
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -4 -
0. Revision history
Revision Date Author Description of change
V1.0 2012-04-21 Lucky DOU Initial
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -5 -
1. Introduction
This document describes how to upgrade firmware using “Firmware Upgrade Tool Advanced
WS1” supplied by Quectel.
This tool can be used to download firmware and format flash, and also can backup and restore
system data of the module, such as IMEI, SN, and calibration data etc.
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -6 -
2. Tool installation
The tool can run smoothly without any installations as long as the OS of PC is among the ones listed
below.
Windows 95
Windows 98
Windows 2000
Windows ME
Windows XP
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -7 -
3. Firmware
The firmware package for one version contains one folder and one database file.
The folder includes the firmware image file and related configure file (.cfg file). The .cfg file is set
in this tool and used to download the firmware.
The database file’s name begins with “BPLG…”. Below is the database file for version
U10AR02A03M1024:
“BPLGUInfoCustomAppSrcP_MT6276_S01_U10AR02A03M1024”.
When the module is upgraded from the old (current) firmware to the new (target) firmware, the
database for old firmware is used to backup the system data, and the database for new firmware is
used to restore the system data.
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -8 -
4. Introduction to the tool
The tool is used to upgrade firmware for the U10 module.
Double click the tool icon, and then the tool is opened with the main interface shown as Figure 1.
Figure 1: The main interface
It works as following steps:
Step1: Choose the correct serial port and baud rate in “Config” area.
Step2: Select the .cfg file for the target (new) firmware in “Files Setting” area.
Step3: Select correct old database file in “Backup Database”.
Step4: Select correct new database file in “Restore Database”.
Step5: Select three options “Backup System Data”, “Download FW and Format” and “Restore
System Data” in “Operate Option” area.
Step6: Click Start button to start backup system data.
Step7: Power off and on the module when getting prompt “Please re-start the terminal” in
Backup Data Process.
Step8: Power off and on the module again when getting prompt “Please re-start the terminal” in
Download Process.
Step9: Power off and on the module again when getting prompt “Please re-start the terminal” in
Restore Process.
The following describes the details on how to use the upgrade tool.
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -9 -
4.1. UI settings
4.1.1. Port configuration
A) Port
According to the connection between PC and Module, select the right serial port as Figure 2.
Figure 2: UI of Port
B) Baud rate
Choose an appropriate baud rate. Please refer to Figure 3.
Note:
1. The maximal baud rate of standard serial cable is 115200, and the USB-Serial cable is
460800.
2. Only the MAIN port can be used to upgrade the firmware. The USB virtual port cannot be
used in this tool.
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -10 -
Figure 3: UI of Baud Rate
C) Get debug log file
It can be ignored.
D) Flash type
It can be ignored.
4.1.2. Files setting
Click Set CFG button to select the .cfg file for the new firmware. The tool will match the .bin file
in the same folder automatically after selected correct .cfg file. Dialogue frames are shown in
Figure 4 & Figure 5.
Figure 4: UI of CFG File: File Open window
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -11 -
Figure 5: UI of CFG File Selected
4.1.3. Database file setting
Click Set Old button to select the backup database file to match with the current firmware.
Click Set New button to select the restore database file to match with the target firmware.
Dialogue frames are shown in Figure 6 and Figure 7.
Note:
The tool can also work successfully even through an incorrect database file was selected, but
there could be some ERRORs when backuping or restoring system data. So, it is very
important to select the correct database file to match with the current or target firmware in
the module.
Figure 6: UI of Set Old File Window Open
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -12 -
Figure 7: UI of Set New File Window Open
4.1.4. Operation Option
Backup System Data:
Enable/Disable to select whether to backup system data or not.
Download FW and Format:
Enable/Disable to select whether to download FW and format or not.
Restore System Data:
Enable/Disable to select whether to restore system data or not.
Note:
1. All options are checked by default. Please refer to Figure 8.
2. Items should be executed in order, but can be single selected or combined with next, such as
A and B, or B and C.
3. It is recommended to do these operations one by one, i.e., select one item and click “Start” to
finish it, then select the next item and click “Star”. The next part will show each step as
example.
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -13 -
Figure 8: UI of Operate Option
4.2. Firmware Upgrade
There are log and indication area, progress bar, Start button and Stop button on the right area of
the tool. The progress bar indicates the progress of upgrading firmware and shows the time expire
of upgrading.
There are several steps in the progress of upgrading firmware:
Backup System Data
Download FW and Format
Restore System Data
Three options can be selected together or separately. The following is taken the each selection as
example.
4.2.1. Backup System Data
1. Select “Backup System Data” option, click the “Start” button. Please refer to Figure 9.
2. When it prompts “Please re-start the terminal.” in the log area, re-start the terminal to start
backuping the system data.
3. When it finished, it will pop up a “Save as” window. Please select the directory and input file
name which is used to save the system data. Please refer to Figure 10.
4. It will indicate “Mission Accomplish. Pass.” if backup is successful as shown in Figure 11.
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -14 -
Figure 9: Backup System Data-1
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -15 -
Figure 10: Backup System Data-2
Figure 11: Backup System Data-3
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -16 -
4.2.2. Download FW and Format
The “Download FW and Format” progress dialogue frames are shown in Figure 12, 13, 14 and
Figure 15.
Select “Download FW and Format” and click “Start” button, when it prompts “Please re-start the
terminal”, restart the module and then it will begin to download the firmware and format.
Figure 12: Download FW and Format-1
Figure 13: Download FW and Format-2
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -17 -
Figure 14: Download FW and Format-3
Figure 15: Download FW and Format-4
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -18 -
4.2.3. Restore system data
Dialogue frames of the “Restore System Data” progress are shown in Figure 16, 17 and Figure 18.
Select “Restore System Data” and click “Start” button, when it prompts “Please re-start the
terminal”, restart the module. When the “Open” window pops up, select the backup system data
file saved in step “Backup System Data”.
Figure 16: Restore System Data
Figure 17: Select the backup file from step Backup System Data
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -19 -
Figure 18: Restore System Data success
Note:
1. To make sure the tool runs successfully, following preparations must be done in advance:
Link PC and module correctly
Choose the correct serial port and baud rate
Choose the right .cfg file to be upgraded
Choose the correct Database File
Re-start Terminal if prompt appears.
2. When all three steps are selected and run together, the system data file will be saved
automatically in the “CalData”folder under the installation directory, and it will be opened
automatically when restoring the system data. If some error occurs and it needs to restore
system data again, please select this data file.
4.2.4. Stop
Click the Stop button to stop upgrading.
Warning:
If the upgrade process is interrupted, there would be no valid firmware in the module. So it is
never recommended to stop the firmware upgrade process.
4.3. Abnormalities
The wrong parameter of Port and Baud rate, the damaged EVB and module, the incorrect file, etc.
may lead to abnormalities as following.
A) Wrong parameter of Port
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -20 -
Figure 19: UI of Blank Port ERROR
Figure 20: UI of Busy Port ERROR
B) Wrong parameter of Baud Rate
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -21 -
Figure 21: UI of Baud Rate ERROR
C) Upgrade with Incorrect File
Figure 22: UI of Upgrade with Incorrect CFG File
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -22 -
Figure 23: UI of Backup System Data ERROR when Cancel to Save File
Figure 24: UI of Restore System Data ERROR when Cancel to Save Data
A) Power supply or USB Abnormal
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -23 -
Figure 25: UI of Backup System Data ERROR when Power Supply Abnormal
Figure 26: UI of Power Supply or USB Abnormal in DA Process
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -24 -
Figure 27: UI of Power Supply or USB Abnormal in Download Process
Figure 28: UI of Power Supply Abnormal in Format Process
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -25 -
Figure 29: UI of USB Abnormal in Restore System Data Process
Figure 30: UI of Power Supply or USB Abnormal When Read System Data to Terminal
Quectel
Confidential
Firmware Upgrade Tool Advanced WS1 User Guide
FW_Upgrade_Tool_Advanced_WS1_UGD_V1.0 -26 -
Figure 31: UI of ERROR when Fail to Save System Data
Figure 32: UI of Error when Fail to Restore System Data
Quectel
Confidential
Shanghai Quectel Wireless Solutions Co., Ltd.
Room 501, Building 13,No.99 Tianzhou Road, Shanghai, China, 200233
Tel: +86 21 5108 6236
Mail: [email protected]