Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3...

4
SS-QTRN www.daikincomfort.com 5/16 Supersedes 3/16 Quaternity Product Features • Inverter Compressor • 208/ 230/ 1 Power Supply Cooling Operang Range: 14° - 109° F Heang Operang Range: -4° - 75° F Precharged for up to 32 ſt of Liquid Line Indoor Sound Pressure as Low as 26 dB(A) Outdoor Sound Pressures as Low as 46 dB(A) Flash Streamer Technology Advanced dehumidificaon 3-D Airflow • Comfortable Mode Indoor Unit Quiet Operaon Auto Changeover Auto Fan Speed Control Self-Diagnoscs with Digital Display Auto Restart aſter Power Failure An-Corrosion Treatment on Heat Exchanger Max Piping: 32' Length, 26' Height Up to 26.1 SEER Performance High-Efficiency Ductless System With Dehumidification & Air-Purification Functions * Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registraon must be completed within 60 days of installaon. Online registraon and some of the addional requirements are not required in California or Quebec. ENERGY STAR ® and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protecon Agency. ENERGY STAR products are third-party cerfied by an EPA-recognized Cerficaon Body. Products that are recognized as the Most Efficient of ENERGY STAR in 2016 prevent greenhouse gas emissions by meeng rigorous energy efficiency performance levels set by the U.S. Environmental Protecon Agency. This product meets ENERGY STAR requirements when appropriate coil components are used. Ask your contractor for details.

Transcript of Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3...

Page 1: Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3 1 grn z3c n=3 mrm10 3.15a fu3 v2 u 1 red s45 mr4 sa1 : surge arrester fu2 y1e l1r

SS-QTRN www.daikincomfort.com 5/16Supersedes 3/16

Quaternity

Product Features• Inverter Compressor• 208/ 230/ 1 Power Supply• Cooling Operating Range: 14° - 109° F • Heating Operating Range: -4° - 75° F• Precharged for up to 32 ft of Liquid Line• Indoor Sound Pressure as Low as 26 dB(A)• Outdoor Sound Pressures as Low as 46 dB(A)• Flash Streamer Technology• Advanced dehumidification• 3-D Airflow

• Comfortable Mode• Indoor Unit Quiet Operation• Auto Changeover• Auto Fan Speed Control• Self-Diagnostics with Digital Display• Auto Restart after Power Failure• Anti-Corrosion Treatment

on Heat Exchanger• Max Piping: 32' Length, 26' Height

Up to 26.1 SEER Performance High-Efficiency Ductless System

With Dehumidification & Air-Purification Functions

* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration and some of the additional requirements are not required in California or Quebec.

ENERGY STAR® and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency. ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Products that are recognized as the Most Efficient of ENERGY STAR in 2016 prevent greenhouse gas emissions by meeting rigorous energy efficiency performance levels set by the U.S. Environmental Protection Agency.

This product meets ENERGY STAR requirements when appropriate coil components are used. Ask your contractor for details.

Page 2: Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3 1 grn z3c n=3 mrm10 3.15a fu3 v2 u 1 red s45 mr4 sa1 : surge arrester fu2 y1e l1r

2 www.daikincomfort.com SS-QTRN SS-QTRN www.daikincomfort.com 3

Product Specifications

Quaternity Premium-Efficiency System Performance

Nominal CapacitiesCooling Capacity (Rated) BTU/h 9,000 12,000 15,000

Cooling Capacity (Min – Max) BTU/h 5,300 - 12,300 5,300 - 15,700 5,300 - 18,000

Heating Capacity (Rated) BTU/h 12,000 16,000 18,000

Heating Capacity (Min – Max) BTU/h 4,400 - 18,000 4,400 - 19,100 4,400 - 21,200

SEER 26.1 24.2 21

COP 4.5 4.0 4.0

EER 15.8 14 12.9

HSPF 11 10.6 10

Electrical DataPower Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60

Minimum Circuit Amps A 14.5 14.5 14.5

Maximum Overcurrent Protection A 15 15 15

Power Consumption - Cooling W 250 - 900 260 - 1,300 260 - 1,930

Power Consumption - Heating W 220 - 1,900 220 - 2,100 230 - 2,120

Indoor Units: FTXG_HVJU Wall-Mounted Units

Model Name FTXG09HVJU FTXG12HVJU FTXG15HVJUMoisture Removal gal/h 0.4 0.5 0.6

Airflow-Wet (H/M/L) CFM 420/325/230 459/346/240 487/371/258

Airflow-Dry (H/M/L) CFM 438/346/258 470/367/272 494/392/293

Sound Pressure - Cooling (H/M/L) dB(A) 42/33/26 43/35/27 45/37/29

Sound Pressure – Heating (H/M/L) dB(A) 42/35/28 43/36/29 44/38/31

Piping Connections

Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4

Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 3/8

Condensate Drain in. Ø 11/16 Ø 11/16 Ø 11/16

Dimensions (H x W x D) in. 12 x 35⅟₃₂ x 8⁷⁄₃₂

Net Weight lbs. 31 31 31

Outdoor Units: RXG_HVJU Heat Pump

Model Name RXG09HVJU RXG12HVJU RXG15HVJUSound Pressure Level - Cooling/Heating dB(A) 46/46 49/48 50/50

Operating Range - Cooling °F DB 14° - 109° 14° - 109° 14° - 109°

Operating Range - Heating °F DB -4° - 75° -4° - 75° -4° - 75°

Max. Piping Length ft. 32 32 32

Max. Piping Height ft. 26 26 26

Dimensions (H x W x D) in. 22⅜ X 31⁹⁄₃₂ x 11⁷⁄₃₂

Net Weight lbs. 99 99 99

Page 3: Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3 1 grn z3c n=3 mrm10 3.15a fu3 v2 u 1 red s45 mr4 sa1 : surge arrester fu2 y1e l1r

2 www.daikincomfort.com SS-QTRN SS-QTRN www.daikincomfort.com 3

Dimensions — Wall-Mounted Indoor Unit

Dimensions — Wall-Mounted Indoor Unit

FTXG09/12/15HVJU

35-1/16(890)

45°45°

I.D. φ9/16(14)CONNECTING PART

O.D. φ11/16(18)

TERMINAL BLOCK WITH EARTH TERMINAL

SIGNAL RECEIVER

55°

30°25°

70° APPROX.23-9/16(598)

1-7/16(37)

8-1/4(209)10-3/4(273)

OPERATING STATE

12 (3

05)

10-13/16(275)

7-1/

8(18

0.5)

33(838)

STANDARD LOCATIONS OF WALL HOLES

APPROX.25-13/16(655)

1-15/16(50)MIN.

9/16(15)

1-3/

4(44

.5)

1-3/

16(3

0)M

IN.

2-5/16(59.5)

1-15/16(50)MIN.

1-1/16(26.8)2-1/2(63)

15°15°

70° 55°APPROX.21-9/16(548)

1-7/8(47)~2-3/8(60)

AIR FLOW (INDOOR)

1 - 3

/ 4 (4

4.5)

9/16

(14.

5)

RIGHT/LEFT(AUTOMATIC)

45°

55°60°

20°

7-1/

16(1

80)

(SPACE FORMAINTENANCE)

UP/DOWN (AUTOMATIC)

SIGNAL TRANSMITTER

WALL HOLE FOREMBEDDED PIPINGφ2-9/16(65) HOLE

COOLINGDRY COOLINGDRY

GAS PIPE φ3/8(9.5)Cut

WIRELESS REMOTE CONTROLLER

DRAIN HOSE

HEATING

ROOM TEMP.THERMISTOR

RIGHT

REQUIRED SPACE

REAR

WALL HOLE

LIQUID PIPE φ1/4(6.4)Cut

AIR PURIFYING(INDIVIDUAL OPERATION)

(SPA

CE

FOR

PER

FOR

MAN

CE)

GEAR CASE UNIT FIXED SCREWS(INSIDE PANEL)

INCLUDINGMOUNTING PLATELEFT

(SPACE FORPERFORMANCE)

THE MARK (→) SHOWS PIPING DIRECTION

BOTTOM

BLADE ANGLE

(ARC447A3)

φ2-9/16(65)HOLE

FRONT GRILL FIXED SCREWS(INSIDE PANEL)

NAMEPLATE

MULTI-COLORED INDICATOR LAMP/ INDOOR UNIT ON/OFF SWITCH

( )

TIMER LAMP

3D061002

Dimensions — Outdoor Unit

RXG09/12/15HVJU

(φ3/8 (9.5) CuT)GAS STOP VALVE

3-1/

8 (7

9)

31-5/16 (795)

19-7/8 (505)

1/2 (13)

4-5/8 (118)

1-15/16 (50)

OUTDOOR AIR THERMISTOR

1-15/16 (50)

2-15

/16

(75)

1-15/16 (50)5-7/

8 (1

50)

BRAND NAME LABEL

(M8 OR M10)4-HOLES FOR ANCHOR BOLTS

12-1/4 (311)

22-5/8 (574)

1-3/

16 (2

9.5)

22-3

/8 (5

69)

PORTSERVICE

5-7/

8 (1

50)

3-15

/16

(100

)

(φ1/4 (6.4) CuT)STOP VALVELIQUID

11-1/4 (285)

HOSE FOR CONNECTION)(I.Dφ5/8 (15.9)DRAIN OUTLET

HANDLE

9/16 (15)

NAME PLATE

2-1/2 (63)

13/16 (20)

11-1

3/16

(300

)

3-3/4 (95.5)

5/8 (15.7)11/16 (17)

1-15

/16

(50)

7 (178)

3-15

/16

(100

)

= LESS THAN 47-3/16 (1200)WALL HEIGHT ON AIR OUTLET SIDEMINIMUM SPACE FOR AIR PASSAGE

STOP VALVE COVERIN CASE OF REMOVING

UNIT=INCH (mm)

(BASE PITCH)

3D062671A

Page 4: Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3 1 grn z3c n=3 mrm10 3.15a fu3 v2 u 1 red s45 mr4 sa1 : surge arrester fu2 y1e l1r

4 www.daikincomfort.com SS-QTRN SS-QTRN www.daikincomfort.com PB

Our continuing commitment to quality products may mean a change in specifications without notice. ©2016 daikin manufacturing company, l.p. • Houston, Texas • Printed in the USA.

Wiring Diagrams

Wiring Diagram — Wall-Mounted Indoor Unit

FTXG09/12/15HVJU

FIELD WIRING.

outdoor

R1T

LED2

H2P

M

Y2S

indoor

TURNED OFF AND THEN BACK

RESTART AUTOMATICALLY IFNOTE THAT OPERATION WILL

THE MAIN POWER SUPPLY IS

ON AGAIN.

CAUTION

SIGNALRECEIVER

MM

R2T

Y1S

MULTIMONITOR

H1P

SIGNALTRANSMITTER

LED3

H3P

M

6

RED

S515

+

1

BLK

S402

5

4S1

7

M3S

BLK

JAZ1C N=4

M2S

GRN

1

1

13

A5P

RED

BLK

S2C

BLK

BLK

RED BL

K

S216

S401

H2

HU

MID

ITY

SEN

SOR

BLK

1

GRN

S1C

S32

7

BLK

S91

BLK

HIGH VOLTAGEUNIT

M1F

BLK

1

(16PIN)

ORG

M

JA

A4P

2

YLW

3

BLK

JUMPER

BLK

BLK

ORG

FG

/

BLK

BLK

TRANSMISSIONCIRCUIT

BLK

ORG

A3P

4

BLK

BLU

BLK

R1V

1

CN1

S41

1

-

H1

BLK

PNK

A1P

PNK

BLK

YLW

H3

S43

BLKBL

K

BLU

A2P

ORG

S57

BLK

2

1

BLK

BLK

1

PNK

S52

S1WYLW

YLW

BLK

BLK

RED

BLK

YLW

REDYLW

M1S

BLK

AN ADDRESS SETUP OF REMOTECONTROLLER

WHT

BLK

X1M

(H250V,T3.15A)

S403

BLU BL

K

S48OR

G

YLW

13

RED

BLK

STREAMER PART

-PN

K

WHT

BLK HA

S56 WHT

RED

BLK

1

S46BL

K

M4S

WIRELESSREMOTE

CONTROLLER

BLK

S58

1

BLU

YLW

ORG

BLU

YLW BL

K

BLU

BRN

BLK

BLK

GRN

: PROTECTIVE GROUND 3

F1U

: FLAME GROUND: FUSE

: PILOT LAMP

: FAN MOTOR

: PRINTED CIRCUIT BOARD

R1T, R2T

: CONNECTOR: OPERATION SWITCH: TERMINAL STRIP

: SWING MOTORM1S~M4S

F1U

M1F

H2P, H3P

S1~S403, CN1

FG

X1MS1W

: THERMISTOR

A1P~A5P

: MULTI MONITORH1P

: LIMIT SWITCH FOR PANELS1C: LIMIT SWITCH FOR STREAMERS2C

: VARISTORR1V

: SOLENOID VALVEY1S, Y2S: FERRITE COREZ1C

3D052768C

Wiring Diagram — Outdoor Unit

RXG09/12/15HVJU

3

12

outdoor

L1R

DB1

NOTE1. REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.

M

FIELD WIRING.

: PROTECTIVE GROUND

indoor

V W

IPM1

U

(CONDENSER)

BLU

FU1

WR2TV

BLK

E2

S70

WHT

X1M : TERMINAL STRIP

102°C

(OUTDOOR)

BLU

(DISCHARGE) M1F

GRN/YLW

3 MRM20

BLU

YLW

3.15A

WHT

X1A : CONNECTOR

ORG

GRN/YLW

HL1

6

HR1

3

RED

YLW

Z2CN=3

WHT

M

Y1R : REVERSING SOLENOIDE VALVE COIL

1

BLK

L1, L2 : LIVE

Q1L

1

YLW

W4

R1T

R1T, R2T, R3T : THERMISTORMR4, MRM10MRM20 : MAGNETIC RELAY

BLK

YLW

S80OL1

Z1CN=4

ORG

2

1

M1F : FAN MOTOR

U

BLU

PPL

2

PCB1 : PRINTED CIRCUIT BOARD

DB3

FU1, FU2, FU3 : FUSE

1

L2

1

Q1L : OVERLOAD PROTECTOR

X1M

S90

V1

3

M1C

WHT

YLWS

BRN

3

1

GRN

Z3CN=3

MRM10

3.15A

WHT

FU3

V2

U

1

RED

S45

MR4

SA1 : SURGE ARRESTER

FU2

Y1E

L1R : REACTOR

L

BLK

YLW

BLK

2HN1

RED

V1, V2 : VARISTOR

Y1E : ELECTRONIC EXPANSION VALVE COIL

RED

E1

DB1, DB2, DB3 : DIODE BRIDGE

7

BRN

Z4CN=2

LDB2

RED

ORG

S20

M

PCB1

X1A

L1

R3T

IPM1 : INTELLIGENT POWER MODULE

V

M1C : COMPRESSOR MOTOR

YLW

30A

OL26

SA1

YLW

BLK

Z1C, Z2C, Z3C, Z4C : FERRITE CORE

HR2

Y1R

+

_

~

~

+

++

_

_

++

_

__+_

~

~

~

~

+_

t° t° t°

1~

3D061486