Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3...
Transcript of Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3...
![Page 1: Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3 1 grn z3c n=3 mrm10 3.15a fu3 v2 u 1 red s45 mr4 sa1 : surge arrester fu2 y1e l1r](https://reader033.fdocuments.in/reader033/viewer/2022042016/5e745dcbbdc0992fb936f522/html5/thumbnails/1.jpg)
SS-QTRN www.daikincomfort.com 5/16Supersedes 3/16
Quaternity
Product Features• Inverter Compressor• 208/ 230/ 1 Power Supply• Cooling Operating Range: 14° - 109° F • Heating Operating Range: -4° - 75° F• Precharged for up to 32 ft of Liquid Line• Indoor Sound Pressure as Low as 26 dB(A)• Outdoor Sound Pressures as Low as 46 dB(A)• Flash Streamer Technology• Advanced dehumidification• 3-D Airflow
• Comfortable Mode• Indoor Unit Quiet Operation• Auto Changeover• Auto Fan Speed Control• Self-Diagnostics with Digital Display• Auto Restart after Power Failure• Anti-Corrosion Treatment
on Heat Exchanger• Max Piping: 32' Length, 26' Height
Up to 26.1 SEER Performance High-Efficiency Ductless System
With Dehumidification & Air-Purification Functions
* Complete warranty details available from your local dealer or at www.daikincomfort.com. To receive the 12-Year Parts Limited Warranty, online registration must be completed within 60 days of installation. Online registration and some of the additional requirements are not required in California or Quebec.
ENERGY STAR® and the ENERGY STAR mark are registered trademarks owned by the U.S. Environmental Protection Agency. ENERGY STAR products are third-party certified by an EPA-recognized Certification Body. Products that are recognized as the Most Efficient of ENERGY STAR in 2016 prevent greenhouse gas emissions by meeting rigorous energy efficiency performance levels set by the U.S. Environmental Protection Agency.
This product meets ENERGY STAR requirements when appropriate coil components are used. Ask your contractor for details.
![Page 2: Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3 1 grn z3c n=3 mrm10 3.15a fu3 v2 u 1 red s45 mr4 sa1 : surge arrester fu2 y1e l1r](https://reader033.fdocuments.in/reader033/viewer/2022042016/5e745dcbbdc0992fb936f522/html5/thumbnails/2.jpg)
2 www.daikincomfort.com SS-QTRN SS-QTRN www.daikincomfort.com 3
Product Specifications
Quaternity Premium-Efficiency System Performance
Nominal CapacitiesCooling Capacity (Rated) BTU/h 9,000 12,000 15,000
Cooling Capacity (Min – Max) BTU/h 5,300 - 12,300 5,300 - 15,700 5,300 - 18,000
Heating Capacity (Rated) BTU/h 12,000 16,000 18,000
Heating Capacity (Min – Max) BTU/h 4,400 - 18,000 4,400 - 19,100 4,400 - 21,200
SEER 26.1 24.2 21
COP 4.5 4.0 4.0
EER 15.8 14 12.9
HSPF 11 10.6 10
Electrical DataPower Supply V/Ph/Hz 208-230/1/60 208-230/1/60 208-230/1/60
Minimum Circuit Amps A 14.5 14.5 14.5
Maximum Overcurrent Protection A 15 15 15
Power Consumption - Cooling W 250 - 900 260 - 1,300 260 - 1,930
Power Consumption - Heating W 220 - 1,900 220 - 2,100 230 - 2,120
Indoor Units: FTXG_HVJU Wall-Mounted Units
Model Name FTXG09HVJU FTXG12HVJU FTXG15HVJUMoisture Removal gal/h 0.4 0.5 0.6
Airflow-Wet (H/M/L) CFM 420/325/230 459/346/240 487/371/258
Airflow-Dry (H/M/L) CFM 438/346/258 470/367/272 494/392/293
Sound Pressure - Cooling (H/M/L) dB(A) 42/33/26 43/35/27 45/37/29
Sound Pressure – Heating (H/M/L) dB(A) 42/35/28 43/36/29 44/38/31
Piping Connections
Liquid (O.D.) in. Ø 1/4 Ø 1/4 Ø 1/4
Gas (O.D.) in. Ø 3/8 Ø 3/8 Ø 3/8
Condensate Drain in. Ø 11/16 Ø 11/16 Ø 11/16
Dimensions (H x W x D) in. 12 x 35⅟₃₂ x 8⁷⁄₃₂
Net Weight lbs. 31 31 31
Outdoor Units: RXG_HVJU Heat Pump
Model Name RXG09HVJU RXG12HVJU RXG15HVJUSound Pressure Level - Cooling/Heating dB(A) 46/46 49/48 50/50
Operating Range - Cooling °F DB 14° - 109° 14° - 109° 14° - 109°
Operating Range - Heating °F DB -4° - 75° -4° - 75° -4° - 75°
Max. Piping Length ft. 32 32 32
Max. Piping Height ft. 26 26 26
Dimensions (H x W x D) in. 22⅜ X 31⁹⁄₃₂ x 11⁷⁄₃₂
Net Weight lbs. 99 99 99
![Page 3: Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3 1 grn z3c n=3 mrm10 3.15a fu3 v2 u 1 red s45 mr4 sa1 : surge arrester fu2 y1e l1r](https://reader033.fdocuments.in/reader033/viewer/2022042016/5e745dcbbdc0992fb936f522/html5/thumbnails/3.jpg)
2 www.daikincomfort.com SS-QTRN SS-QTRN www.daikincomfort.com 3
Dimensions — Wall-Mounted Indoor Unit
Dimensions — Wall-Mounted Indoor Unit
FTXG09/12/15HVJU
35-1/16(890)
45°45°
I.D. φ9/16(14)CONNECTING PART
O.D. φ11/16(18)
TERMINAL BLOCK WITH EARTH TERMINAL
SIGNAL RECEIVER
55°
30°25°
70° APPROX.23-9/16(598)
1-7/16(37)
8-1/4(209)10-3/4(273)
OPERATING STATE
12 (3
05)
10-13/16(275)
7-1/
8(18
0.5)
33(838)
STANDARD LOCATIONS OF WALL HOLES
APPROX.25-13/16(655)
1-15/16(50)MIN.
9/16(15)
1-3/
4(44
.5)
1-3/
16(3
0)M
IN.
2-5/16(59.5)
1-15/16(50)MIN.
1-1/16(26.8)2-1/2(63)
15°15°
70° 55°APPROX.21-9/16(548)
1-7/8(47)~2-3/8(60)
AIR FLOW (INDOOR)
1 - 3
/ 4 (4
4.5)
9/16
(14.
5)
RIGHT/LEFT(AUTOMATIC)
45°
55°60°
20°
7-1/
16(1
80)
(SPACE FORMAINTENANCE)
UP/DOWN (AUTOMATIC)
SIGNAL TRANSMITTER
WALL HOLE FOREMBEDDED PIPINGφ2-9/16(65) HOLE
COOLINGDRY COOLINGDRY
GAS PIPE φ3/8(9.5)Cut
WIRELESS REMOTE CONTROLLER
DRAIN HOSE
HEATING
ROOM TEMP.THERMISTOR
RIGHT
REQUIRED SPACE
REAR
WALL HOLE
LIQUID PIPE φ1/4(6.4)Cut
AIR PURIFYING(INDIVIDUAL OPERATION)
(SPA
CE
FOR
PER
FOR
MAN
CE)
GEAR CASE UNIT FIXED SCREWS(INSIDE PANEL)
INCLUDINGMOUNTING PLATELEFT
(SPACE FORPERFORMANCE)
THE MARK (→) SHOWS PIPING DIRECTION
BOTTOM
BLADE ANGLE
(ARC447A3)
φ2-9/16(65)HOLE
FRONT GRILL FIXED SCREWS(INSIDE PANEL)
NAMEPLATE
MULTI-COLORED INDICATOR LAMP/ INDOOR UNIT ON/OFF SWITCH
( )
TIMER LAMP
3D061002
Dimensions — Outdoor Unit
RXG09/12/15HVJU
(φ3/8 (9.5) CuT)GAS STOP VALVE
3-1/
8 (7
9)
31-5/16 (795)
19-7/8 (505)
1/2 (13)
4-5/8 (118)
1-15/16 (50)
OUTDOOR AIR THERMISTOR
1-15/16 (50)
2-15
/16
(75)
1-15/16 (50)5-7/
8 (1
50)
BRAND NAME LABEL
(M8 OR M10)4-HOLES FOR ANCHOR BOLTS
12-1/4 (311)
22-5/8 (574)
1-3/
16 (2
9.5)
22-3
/8 (5
69)
PORTSERVICE
5-7/
8 (1
50)
3-15
/16
(100
)
(φ1/4 (6.4) CuT)STOP VALVELIQUID
11-1/4 (285)
HOSE FOR CONNECTION)(I.Dφ5/8 (15.9)DRAIN OUTLET
HANDLE
9/16 (15)
NAME PLATE
2-1/2 (63)
13/16 (20)
11-1
3/16
(300
)
3-3/4 (95.5)
5/8 (15.7)11/16 (17)
1-15
/16
(50)
7 (178)
3-15
/16
(100
)
= LESS THAN 47-3/16 (1200)WALL HEIGHT ON AIR OUTLET SIDEMINIMUM SPACE FOR AIR PASSAGE
STOP VALVE COVERIN CASE OF REMOVING
UNIT=INCH (mm)
(BASE PITCH)
3D062671A
![Page 4: Quaternity...db3 fu1, fu2, fu3 : fuse 1 l 2 1 q1l: overload protector x1m s90 v1 3 m1c ylw s br n 3 1 grn z3c n=3 mrm10 3.15a fu3 v2 u 1 red s45 mr4 sa1 : surge arrester fu2 y1e l1r](https://reader033.fdocuments.in/reader033/viewer/2022042016/5e745dcbbdc0992fb936f522/html5/thumbnails/4.jpg)
4 www.daikincomfort.com SS-QTRN SS-QTRN www.daikincomfort.com PB
Our continuing commitment to quality products may mean a change in specifications without notice. ©2016 daikin manufacturing company, l.p. • Houston, Texas • Printed in the USA.
Wiring Diagrams
Wiring Diagram — Wall-Mounted Indoor Unit
FTXG09/12/15HVJU
FIELD WIRING.
outdoor
R1T
t°
LED2
H2P
M
Y2S
indoor
TURNED OFF AND THEN BACK
RESTART AUTOMATICALLY IFNOTE THAT OPERATION WILL
THE MAIN POWER SUPPLY IS
ON AGAIN.
CAUTION
SIGNALRECEIVER
MM
t°
R2T
Y1S
MULTIMONITOR
H1P
SIGNALTRANSMITTER
LED3
H3P
M
6
RED
S515
+
1
BLK
S402
5
4S1
7
M3S
BLK
JAZ1C N=4
M2S
GRN
1
1
13
A5P
RED
BLK
S2C
BLK
BLK
RED BL
K
S216
S401
H2
HU
MID
ITY
SEN
SOR
BLK
1
GRN
S1C
S32
7
BLK
S91
BLK
HIGH VOLTAGEUNIT
M1F
BLK
1
(16PIN)
ORG
M
JA
A4P
2
YLW
3
BLK
JUMPER
BLK
BLK
ORG
FG
/
BLK
BLK
TRANSMISSIONCIRCUIT
BLK
ORG
A3P
4
BLK
BLU
BLK
R1V
1
CN1
S41
1
-
H1
BLK
PNK
A1P
PNK
BLK
YLW
H3
S43
BLKBL
K
BLU
A2P
ORG
S57
BLK
2
1
BLK
BLK
1
PNK
S52
S1WYLW
YLW
BLK
BLK
RED
BLK
YLW
REDYLW
M1S
BLK
AN ADDRESS SETUP OF REMOTECONTROLLER
WHT
BLK
X1M
(H250V,T3.15A)
S403
BLU BL
K
S48OR
G
YLW
13
RED
BLK
STREAMER PART
-PN
K
WHT
BLK HA
S56 WHT
RED
BLK
1
S46BL
K
M4S
WIRELESSREMOTE
CONTROLLER
BLK
S58
1
BLU
YLW
ORG
BLU
YLW BL
K
BLU
BRN
BLK
BLK
GRN
: PROTECTIVE GROUND 3
F1U
: FLAME GROUND: FUSE
: PILOT LAMP
: FAN MOTOR
: PRINTED CIRCUIT BOARD
R1T, R2T
: CONNECTOR: OPERATION SWITCH: TERMINAL STRIP
: SWING MOTORM1S~M4S
F1U
M1F
H2P, H3P
S1~S403, CN1
FG
X1MS1W
: THERMISTOR
A1P~A5P
: MULTI MONITORH1P
: LIMIT SWITCH FOR PANELS1C: LIMIT SWITCH FOR STREAMERS2C
: VARISTORR1V
: SOLENOID VALVEY1S, Y2S: FERRITE COREZ1C
3D052768C
Wiring Diagram — Outdoor Unit
RXG09/12/15HVJU
3
12
outdoor
L1R
DB1
NOTE1. REFER TO THE NAMEPLATE FOR THE POWER REQUIREMENTS.
M
FIELD WIRING.
: PROTECTIVE GROUND
indoor
V W
IPM1
U
(CONDENSER)
BLU
FU1
WR2TV
BLK
E2
S70
WHT
X1M : TERMINAL STRIP
102°C
(OUTDOOR)
BLU
(DISCHARGE) M1F
GRN/YLW
3 MRM20
BLU
YLW
3.15A
WHT
X1A : CONNECTOR
ORG
GRN/YLW
HL1
6
HR1
3
RED
YLW
Z2CN=3
WHT
M
Y1R : REVERSING SOLENOIDE VALVE COIL
1
BLK
L1, L2 : LIVE
Q1L
1
YLW
W4
R1T
R1T, R2T, R3T : THERMISTORMR4, MRM10MRM20 : MAGNETIC RELAY
BLK
YLW
S80OL1
Z1CN=4
ORG
2
1
M1F : FAN MOTOR
U
BLU
PPL
2
PCB1 : PRINTED CIRCUIT BOARD
DB3
FU1, FU2, FU3 : FUSE
1
L2
1
Q1L : OVERLOAD PROTECTOR
X1M
S90
V1
3
M1C
WHT
YLWS
BRN
3
1
GRN
Z3CN=3
MRM10
3.15A
WHT
FU3
V2
U
1
RED
S45
MR4
SA1 : SURGE ARRESTER
FU2
Y1E
L1R : REACTOR
L
BLK
YLW
BLK
2HN1
RED
V1, V2 : VARISTOR
Y1E : ELECTRONIC EXPANSION VALVE COIL
RED
E1
DB1, DB2, DB3 : DIODE BRIDGE
7
BRN
Z4CN=2
LDB2
RED
ORG
S20
M
PCB1
X1A
L1
R3T
IPM1 : INTELLIGENT POWER MODULE
V
M1C : COMPRESSOR MOTOR
YLW
30A
OL26
SA1
YLW
BLK
Z1C, Z2C, Z3C, Z4C : FERRITE CORE
HR2
Y1R
+
_
~
~
+
++
_
_
++
_
__+_
~
~
~
~
+_
t° t° t°
1~
3D061486