QuantaPlex T21SR-2U

39
Quanta Confidential QuantaPlex T21SR-2U 2U 2-Node High Availability Cluster Server Quanta CCBU Marketing Division Version 03

Transcript of QuantaPlex T21SR-2U

Page 1: QuantaPlex T21SR-2U

Quanta Confidential

QuantaPlex T21SR-2U 2U 2-Node High Availability Cluster Server

Quanta CCBU Marketing Division

Version 03

Page 2: QuantaPlex T21SR-2U

www.QuantaQCT.com

Legal Disclaimer INFORMATION IN THIS DOCUMENT IS PROVIDED IN CONNECTION WITH QUANTA PRODUCTS. NO LICENSE, EXPRESS OR IMPLIED, BY ESTOPPEL OR OTHERWISE, TO ANY INTELLECTUAL PROPERTY RIGHTS IS GRANTED BY THIS DOCUMENT. EXCEPT AS PROVIDED IN QUANTA'S TERMS AND CONDITIONS OF SALE FOR SUCH PRODUCTS, QUANTA ASSUMES NO LIABILITY WHATSOEVER AND QUANTA DISCLAIMS ANY EXPRESS OR IMPLIED WARRANTY, RELATING TO SALE AND/OR USE OF QUANTA PRODUCTS INCLUDING LIABILITY OR WARRANTIES RELATING TO FITNESS FOR A PARTICULAR PURPOSE, MERCHANTABILITY, OR INFRINGEMENT OF ANY PATENT, COPYRIGHT OR OTHER INTELLECTUAL PROPERTY RIGHT.

UNLESS OTHERWISE AGREED IN WRITING BY QUANTA, THE QUANTA PRODUCTS ARE NOT DESIGNED NOR INTENDED FOR ANY APPLICATION IN WHICH THE FAILURE OF THE QUANTA PRODUCT COULD CREATE A SITUATION WHERE PERSONAL INJURY OR DEATH MAY OCCUR.

Quanta may make changes to specifications and product descriptions at any time, without notice. Designers must not rely on the absence or characteristics of any features or instructions marked "reserved" or "undefined." Quanta reserves these for future definition and shall have no responsibility whatsoever for conflicts or incompatibilities arising from future changes to them. The information here is subject to change without notice. Do not finalize a design with this information.

The products described in this document may contain design defects or errors known as errata which may cause the product to deviate from published specifications. Current characterized errata are available on request.

All products, computer systems, dates, and figures specified are preliminary based on current expectations, and are subject to change without notice. Contact your local Quanta sales office or your distributor to obtain the latest specifications and before placing your product order.

2

Copyright © 2012 Quanta Computer Inc. All rights reserved. Other names and brands may be claimed as the property of others.

Quanta Confidential

Page 3: QuantaPlex T21SR-2U

www.QuantaQCT.com

Agenda

• Product Introduction

• Target Customer and TAM Size

• Selling Point

• Improved Design

• Competitors Analysis

• Product Overview

3

Page 4: QuantaPlex T21SR-2U

www.QuantaQCT.com

Product Introduction QuantaPlex T21SR-2U

4 Quanta Confidential

Page 5: QuantaPlex T21SR-2U

www.QuantaQCT.com 5

Key Attributes: 1. Cluster-in-a-Box Infrastructure

2. On-The-Fly Cache Synchronization

3. Node Awareness

4. Data Vaulting

5. Ideal Platform for Windows Storage Server 2012 R2

Windows Azure Pack & System Center

Linux Cluster

Nexenta NexentaStor

VMware Cluster

Proprietary Dual Controller Storage Software

QuantaPlex T21SR-2U 2U 2-Node High Availability Cluster Server

Quanta Confidential

Page 6: QuantaPlex T21SR-2U

www.QuantaQCT.com

Dimension(WxHxD): 444mmx 87.5mmx 790mm

Node: 2 nodes in a system

CPU: 2x Intel® Xeon E5-2600 V3 family, up to 145W per node

Chipset: Intel® C610

DIMM slot: 16 x DDR4 RDIMM/LRDIMM per node

HDD: 12x 3.5“ or 24x 2.5” SAS HDD/SSD shared storage

2 x 7mm SATA SSD for OS installation per node

Expansion(per node):

1x PCIe x8 G3 slot for OCP mezzanine card

3 x PCIe x8 G3 riser slot low-profile card

PSU: 2x 1200W or 1600W Platinum high efficiency PSU

Interconnection: Intel NTB and 2x 10Gb

Data Vaulting: Battery backup, one battery per node

Node Awareness: PEER_PRESENT, PEER_RESET, PEER_LOCATE

QuantaPlex T21SR-2U Overview

6 Quanta Confidential

Page 7: QuantaPlex T21SR-2U

www.QuantaQCT.com 7

1. High Availability Storage Appliance

2. Clustered Network Attached Storage

3. Clustered Computing System

4. Continuous Business Platform

5. Virtualized Cluster Server

Best hardware for storage software developer

and solution integrator whom are looking for:

Target Customers

Quanta Confidential

Page 8: QuantaPlex T21SR-2U

www.QuantaQCT.com

Product Selling Points

8

Page 9: QuantaPlex T21SR-2U

www.QuantaQCT.com 9

Cluster-in-a-Box Infrastructure (I) - Compact & Consolidation

1U Server 1U Server

2U JBOD

SAS Cable

SAS Cable

SAS Cable

SAS Cable

Interconnected Ethernet Cable

Before…

Complicated & Error-Oriented!

Quanta Confidential

Page 10: QuantaPlex T21SR-2U

www.QuantaQCT.com 10

Cluster-in-a-Box Infrastructure (II) - Compact & Consolidation

Simple OOBE!!

Clustered dual nodes, hard wired

T21SR-2U

OOBE: Out of Box Experience

Shared storage

Now… with T21SR-2U

Quanta Confidential

Page 11: QuantaPlex T21SR-2U

www.QuantaQCT.com 11

Fully Redundant Data Paths - Continuous Business

Node Level

SAS Expander Level

Storage Level

Interconnection Level Not Only

High Availability…

But

Continuous Business!!

Data

Quanta Confidential

Provide 4 levels of

redundant data path Data

Page 12: QuantaPlex T21SR-2U

www.QuantaQCT.com 12

No Single-Point-Of-Failure (SPOF) - High Reliability, Availability and Serviceability

Redundant Node

Redundant Expander

Shared Storage

Redundant FAN

Redundant Power Supply

All Hot-Swappable! Redundant Interconnection

Quanta Confidential

Page 13: QuantaPlex T21SR-2U

www.QuantaQCT.com 13

On-The-Fly Cache Synchronization - Consistent & Instant Failover

PCIe NTB

PCIe NTB: PCI Express Non-Transparent Bridge

1. Write to local

memory 2. Write to

remote memory

simultaneously!

Quanta Confidential

With NTB, storage software can ensure data in memory can be

synchronized to each node instantly. This is the most important

design to enable instant node failover while one node failed.

Page 14: QuantaPlex T21SR-2U

www.QuantaQCT.com 14

Data Vaulting – Battery Backup (I) - Enable Write Back & Prevent Data Lost While Power Lost

1. One battery per node, can sustain whole MB

node includes local flash device within 120 seconds, allow software to backup dirty data in memory!

Battery

2. More Flexible and easy for software developer to plan read cache and write cache within whole memory range.

Quanta Confidential

SATA SSD

UFM

Page 15: QuantaPlex T21SR-2U

www.QuantaQCT.com 15

Data Vaulting – Battery Backup (II) - Enable Write Back & Prevent Data Lost While Power Lost

Quanta Confidential

3 typical ways in data vaulting:

UPS

Pros: Simple

Cons: Expensive and consume rack density

Battery

Pros: Cost effective, easy and wide range to plan write cache

Cons: Shorter life cycle

NVDIMM

Pros: Fast & backup automatically

Cons: Expensive and restricted write cache area

Page 16: QuantaPlex T21SR-2U

www.QuantaQCT.com 16

Enterprise-Class Node Awareness - Dual-Controller Storage Platform

NODE_LOCATE

NODE_PRESENT

NODE_RESET

Node Awareness is supported

by IPMI OEM command,

allow software developer to:

- Prevent SW deadlock

- Master/Slave Selection

- Cache Policy Planning

- Transparent Failover

- Data Replication

- Load Balance

- Active/Passive Algorithm

….. etc

Quanta Confidential

Page 17: QuantaPlex T21SR-2U

www.QuantaQCT.com 17

Various OCP Network Mezz Option

OCP Mezzanine Lan Card Supported OCP Mezz

• Various OCP Mezz network choice

• Quanta fully validate to ensure performance and quality

- Provide High Flexibility

Speed Port Vendor/Chip

Copper Gb RJ45 2 Intel i350

10Gb RJ45* 2 Intel x540

Fiber 10Gb SFP+ 2 82599ES

Quanta Confidential

Page 18: QuantaPlex T21SR-2U

www.QuantaQCT.com

- Lower fan power, Lower RVI

• Dual rotor fan keeps the system internal air flowing in the right direction

• Save fan power by lower fan speed

• Lower RVI(Rotational Vibration Interference), lower impact to Hard Drives R/W performance

18

Dual Rotor Fan Design

Quanta Confidential

Page 19: QuantaPlex T21SR-2U

www.QuantaQCT.com 19

• Straightforward to remove and replace fan by hot pluggable fan design

• Provide quick service without down time

Hot Pluggable, Prevent Down Time

- Prevent Service Down Time

Dual Rotors

N+1 Rotor Redundancy

Quanta Confidential

Page 20: QuantaPlex T21SR-2U

www.QuantaQCT.com 20

• Easy to replace

• Save service time

*PDB is Power Distribution Board

High Serviceability - Modularized PDB Cage Design

Quanta Confidential

Page 21: QuantaPlex T21SR-2U

www.QuantaQCT.com

OCP Mezz card Dedicated NIC( Highly secure)

Flexible Shared-NIC Options (1)

MB Sled 1 MB Sled 2

Enhanced BIOS option allowing multiple network environment topologies

– Dedicated NIC

– Shared-NIC to OCP Mezz Card

-Easy Setting in BIOS Menu

Quanta Confidential

Page 22: QuantaPlex T21SR-2U

www.QuantaQCT.com 22

-Reduce TOR( top-of-rack) by Flexible Shared-NIC Options

Dedicated Management Network Topology

Shared-NIC network topology

1 TOR only

Flexible Shared-NIC Options (2)

Quanta Confidential

Page 23: QuantaPlex T21SR-2U

www.QuantaQCT.com

Continuous Business

Cluster-in-a-Box Infrastructure

Fully Redundant Data Path

No Single-Point-Of-Failure (SPOF)

On-The-Fly Cache Synchronization

Data Vaulting

Node Awareness

Service & Management Friendly

Flexible OCP Mezz for multiple network choice

Dual Rotor Fan & N+1 Rotor Design

High Serviceability

Flexible Shared-NIC Topology

23

QuantaPlex T21SR-2U Featuring:

Quanta Confidential

Page 24: QuantaPlex T21SR-2U

www.QuantaQCT.com

Improved Design

24

Page 25: QuantaPlex T21SR-2U

www.QuantaQCT.com 25

• Easy install and lock MB tray correctly

into the system

Improved Design

Removing a mainboard sled Installing a mainboard sled

- Sled Lever

Quanta Confidential

Page 26: QuantaPlex T21SR-2U

www.QuantaQCT.com 26

• Design 2x guide pins in each sled

• Enhance MB tray board-to-board connection

Improved Design - Reliable Connection by Guide Pin Design

Quanta Confidential

Page 27: QuantaPlex T21SR-2U

www.QuantaQCT.com 27

Improved Design - Reduce the cable connection

Before( Romley model) After ( Grantley model )

• Simplify cable routing

• Prevent mistake in cable connection

• Prevent loose connection after long distance transportation

Quanta Confidential

Page 28: QuantaPlex T21SR-2U

www.QuantaQCT.com 28

SAS Expender Sled Computer Node Sled

Quanta Confidential

Improved Design - Expander Sled and Compute Sled can service separately

• Simplify expander & MB service

• No SAS cable touching service

Replace Expander Sled and Compute Sled Separately!

Page 29: QuantaPlex T21SR-2U

www.QuantaQCT.com

Sled Lever Design

Guide Pin Design

Simplified Cable Management

Separated Expander & MB Design

29

QuantaPlex T21SR-2U Improved Design:

Quanta Confidential

Page 30: QuantaPlex T21SR-2U

www.QuantaQCT.com

Competitors Comparison

30

Model Quanta QuantaPlex T21SR-2U SuperMicro SuperStorage 2027B-DE2R24L

Form Factor 2U, 444mmx 87.5mmx 790mm 2U, 437mmx88mmx679mm

CPU (Per Node) (2) Intel® Xeon® processor E5-2600 V3 family per node, up to 135W (2) Intel® Xeon® processor E5-2400 v2, up to 95W

Chipset(Per Node) Intel® C610 Intel® C602J chipset

System Memory(Per Node) (16) DDR4 ECC UDIMM/RDIMM/LRDIMM slots per node (6) DDR3 ECC UDIMM/RDIMM slots per node

PCI-e Slot(Per Node)(3) PCIe x8 Gen3 riser slot for 3 low-profile card per node

(1) PCIe x8 Gen3 OCP Mezzanine slot for OCP card per node(3) PCI-E 3.0 x8 slots (on riser)

SAS (1) JBOD expansion port per node (1) JBOD expansion port per node

Integrated Graphics BMC(Per

Node)Aspeed AST2400 8MB DDR3 Video memory Nuvoton WPCM450 BMC

Network(Per Node)

(1) Quanta1GbE RJ45 dual ports OCP mezzanine card(optional)

(1) Quanta 10Gb SFP+ dual port OCP mezzanine card (optional)

(1) Quanta 10GBaseT dual port OCP mezzanine card (optional)

(2) RJ45 LAN ports on board

Management Port(Per Node) (1) Dedicated 10/100/1000 BASE-T RJ45 management port per node (1) Dedicated 10/100/1000 BASE-T RJ45 management port per node

Rear I/O(Per Node)(2) USB 2.0/3.0 ports per node, (1) VGA per node, (1) RS232 Serial port per node

, (1) 10/100/1000 BASE-T RJ45 management port per node

(1) VGA Port (via KVM cable), (1) console port, 2x USB rear ports (via KVM

cable)

HDD (12) 3.5" or (24) 2.5" hot-plug SAS HDD with 12Gb Expander (24) 2.5" hot-plug SAS HDD with 12Gb Expander

(2) 2.5” hot-plug SATA SSD with C610 AHCI port (per node) Internal 2x SAS/SATA ports for OS load on SLC SATA DOM

(1) UFM (optional)

PSU Two 1200W high efficiency Full redundant PSU , 100-240VAC 50/60Hz 920W high-efficiency Redundant power supplies, 100-240 V, 50-60 Hz

Data Vaulting (Per Node) Battery Backup support NA

Inter-connection Intel NTB and dual 10Gb KR PCI-E 3.0 x8 node to node/NTB connectivity by PLX Technology PEX8717

Node Awareness PEER_PRESENT, PEER_RESET, PEER_LOCATE NA

System Management IPMI v2.0 Compliant, on board "KVM over IP" support IPMI 2.0 with virtual media over LAN and KVM-over-LAN support

Quanta Confidential

Page 31: QuantaPlex T21SR-2U

www.QuantaQCT.com 31

2.5” System ID View

Service Tag

Handle Front Access USB

Power Button (w/ Power, Status LED)

ID Button (w/ ID LED)

Quanta Confidential

Page 32: QuantaPlex T21SR-2U

www.QuantaQCT.com 32

OCP Mezz

Sled rear I/O

Bottom PSU (1200W or 1600W)

Top PSU ( 1200W or 1600W)

2x USB 3.0

VGA port

COM port

Management port

12G SAS external Port x4

2x Hot swappable SATA SSD HDD

MB Sled 1 MB Sled 2

3x HHHL PCIe card Expander sled handle

Quanta Confidential

Riser 1

Riser 2

Riser 3

Page 33: QuantaPlex T21SR-2U

www.QuantaQCT.com

Sled Outlet

33

SAS Expender Sled

Computer Node Sled

Quanta Confidential

Expander Sled and Compute Sled can be serviced separately!

Page 34: QuantaPlex T21SR-2U

www.QuantaQCT.com 34

MB Node with Battery

Battery (*)

Memory SATA SSD

UFM

Quanta Confidential

(*) Battery need to be serviced with MB node together

Page 35: QuantaPlex T21SR-2U

www.QuantaQCT.com 35

T21SR-2U MB Block Diagram

Riser 1 & Riser 2

10Gb Interconnection Riser 3

Quanta Confidential

Page 36: QuantaPlex T21SR-2U

www.QuantaQCT.com 36

System Specifications Feature Specification

CPU (Per Node) (2) Intel® Xeon® processor E5-2600 V3 family per node, up to 135W

Chipset(Per Node) Intel® C610

Motherboard 6.5" x 19.38" (half-width), two clustered MBs in a 2U chassis

System Memory(Per Node) (16) DDR4 1333/1600/1866/2133 MHz ECC UDIMM/RDIMM slots per node, up to 512 GB (16) DDR4 1333/1600/1866/2133 MHz ECC LRDIMM slots per node, up to 2048 GB

PCI-e Slot(Per Node) (3) PCIe x8 Gen3 riser slot for 3 low-profile card per node (1) PCIe x8 Gen3 OCP Mezzanine slot for OCP card per node

Integrated Graphics BMC(Per Node) Aspeed AST2400 8MB DDR3 Video memory

Network(Per Node) (1) Intel® Twinville I350 1GbE RJ45 dual ports OCP mezzanine card(optional) (1) Quanta 10Gb SFP+ dual port OCP mezzanine card (optional) (1) Quanta 10GBaseT dual port OCP mezzanine card (optional)

Management Port(Per Node) (1) Dedicated 10/100 BASE-T RJ45 management port per node

Rear I/O(Per Node) (2) USB 2.0/3.0 ports per node, (1) VGA per node, (1) RS232 Serial port per node , (1) 10/100 BASE-T RJ45 management port per node

HDD (12) 3.5" or (24)2.5" hot-plug SAS HDD with 12Gb Expander ( 2 )2.5” of 9mm height HDD with C610 AHCI port (per node) ( 1 ) UFM (optional)

PSU Two 1200W high efficiency Full redundant PSU , 100-240VAC 50/60Hz (1600W 200-240VAC, optional)

Battery (Per Node) Battery Backup support

Inter-connection Intel NTB and dual 10Gb KR

System Management IPMI v2.0 Compliant, on board "KVM over IP" support

Dimension 444mm x 87.5mm x 790mm (17.5” x 3.4” x 31.1”)

L6 Weight 28.81Kg (w/battery) ; 34.8Kg(w/battery and packing) ;

Quanta Confidential

Page 37: QuantaPlex T21SR-2U

www.QuantaQCT.com 37

Sensor name Events Battery_State 0: Charge Inhibit

1: Charging 2: Discharging 3: Fully Charged 4: Battery low 6: Shutdown

Battery_PSU_STA

0:Presence detected 1:Power Supply Failure detected 3:Power Supply input lost

Battery_Temp Temperature reading Battery_Input Battery Input power consumption Battery_Output Battery Output power consumption Battery_Capacity Battery Capacity reading Battery_Status 0: Battery Bad

1: Battery PF 2: Communication Loss 3: Battery Low Fault 4: Battery Low Warning 5: EEPROM Failure 6: Hardware Failure 7: Other Internal Failure

Battery Status & Information in BMC

Quanta Confidential

Page 38: QuantaPlex T21SR-2U

www.QuantaQCT.com 38

get Peer Present.

ipmitool –H <BMC_IP> -U admin –P admin raw 0x30 0x7B

Response:

Byte 1 – completion code

Byte 2 –Present Bit

Byte 2 bit 0 denote MB0

Byte 2 bit 1 denote MB1…

set Peer Reset

ipmitool –H <BMC_IP> -U admin –P admin raw 0x30 0x7C 0x00

Request:

Byte 1:- reset code

Byte 2 – MB No(0 base)

00h: MB0, 01h: MB1, 02h: MB2, 03h: MB3

get Node location

ipmitool –H <BMC_IP> -U admin –P admin raw 0x30 0x7d

Response:

Byte 1 – completion code

Byte 2 – MB position ID

FFh : unspecified

Get Peer Information & Peer Reset

Page 39: QuantaPlex T21SR-2U

www.QuantaQCT.com

Thank You!

39