Quality Control Area

4
Quality Control Area 1. Chemical Testing Room : 20 Square Meter 2. Instrument Room : 25 Square Meter 3. Microbiology Room : 25 Square Meter Total Area : 70 Square Meter Chemical Testing Room Provision : Laboratories designed , constructed and maintained prevent Entry of insects and rodents besides cross contamination Interior surface (walls, floor, and ceilings) smooth free from cracks, Easy cleaning and disinfection Joints Coved wall to wall ceiling to wall floor to wall utilities like Regular supply DM water for Washing Laboratory Accessories Glassware Etc…………. Sampling Area of water Testing Purpose Hand washing area with drier ROOM AIR with AIR CONDITION

description

qc

Transcript of Quality Control Area

Page 1: Quality Control Area

Quality Control Area

1. Chemical Testing Room : 20 Square Meter

2. Instrument Room : 25 Square Meter

3. Microbiology Room : 25 Square Meter

Total Area : 70 Square Meter

Chemical Testing Room Provision :

Laboratories designed , constructed and maintained prevent Entry of insects and rodents besides cross contamination

Interior surface (walls, floor, and ceilings) smooth free from cracks, Easy cleaning and disinfection Joints Coved wall to wall ceiling to wall floor to wall

utilities like Regular supply DM water for Washing Laboratory Accessories Glassware Etc………….

Sampling Area of water Testing Purpose

Hand washing area with drier

ROOM AIR with AIR CONDITION

Temperature 20- 22 CRH 45-60 Lighting & ventilation

Drainage System Back flow

Construction Materials resistant from acid, alkali, solvent

Separate storage facilities Test samples, retained samples ,reagents and laboratory accessories , reference substances and reference materials, Records ,Etc…………..securely locked.

Page 2: Quality Control Area

Secure Waste Disposal Area

First aid kit and Fire fighting equipments located at the right places Fire fighting equipment fire extinguishers, fire blankets and gas masks,

Instrument Room Provision :

Laboratories designed , constructed and maintained prevent Entry of insects and rodents besides cross contamination

Interior surface (walls, floor, and ceilings) smooth free from cracks, Easy cleaning and disinfection Joints Coved wall to wall ceiling to wall floor to wall

Lighting & ventilation

Construction Materials resistant from acid, alkali, solvent

Separate storage facilities samples, retained samples ,reagents and laboratory accessories , reference substances and reference materials Records ,Etc…………..securely locked.

Hand washing area with drier

AIR CONDITION PROVIDEDTemperature 20- 22 CRH 45-60

First aid kit and Fire fighting equipments located at the right places

Fire fighting equipment fire extinguishers, fire blankets and gas masks,

Microbiology ROOM Provision :

Laboratories designed , constructed and maintained prevent Entry of insects and rodents besides cross contamination

Page 3: Quality Control Area

Interior surface (walls, floor, and ceilings) smooth free from cracks, Easy cleaning and disinfection Joints Coved all to wall ceiling to wall floor to wall

to avoid mix ups, contamination and cross-contamination. samples, reference organisms, media testing and records. separate storage locations

AIR LOCK Separate AHU,LAMINAR AIR FLOW WORK STATION

Temperature 20- 22 CRH 45-60 Air pressure 15 paSecure Waste Disposal Area

Hand washing area with drier

General Condition : 5 People Working area Electrical Points provided for EquipmentsEsd chair or SS Stool Computer Printers Each room log book providing facility