qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant...

18

Transcript of qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant...

Page 1: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...
Page 2: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

7www.magnaflux.com • 847.657.5300

ZYGLO® is an extremely sensitive fluorescent penetrant inspectionmethod that reveals cracks andother surface discontinuities in virtually any non-porous material.

ZYGLO is available in aerosols and liquid form.

Five sensitivity levels to satisfy military, industry or company specifications.

Water Wash and Post Emulsifiable penetrants are available.

Full line of emulsifiers, removers and developers.

Preclean inspectionarea. Spray onCleaner/Remover.Wipe off with cloth.

Apply Penetrant.Allow short penetration period.

Spray Cleaner/Remover on wipingcloth and wipe surface clean.

Apply a thin film ofdeveloper. Allow shortdeveloping period. Forrough surfaces, daubon Dry Developer.

Inspect under black light.Cracks and lack of bondwill show as glowinglines, porosity will showas spots.

ApplicationsAerospace Industry(Aircraft Manufacturers, Aircraft ComponentManufacturers, Aircraft Overhaul Shops,Airlines) Engine components (blades, rotors & turbines)Landing gearWheelsWing sparsBrakesSprings

Military

Automotive Components ManufacturersBrakesSteering componentsConnecting rodsWheelsEngine mountsPistonsCylinder blocks

FoundriesRaw Castings

Test LabsNDT Inspections

BenefitsZYGLO fluorescent penetrants are formu-lated to offer improved sensitivity, bright-ness and resistance to over washing. Justlike our visible penetrants we use high quality raw materials to give superiorresults in finding defects. Our ZYGLO penetrant products are known in theindustry for their consistent performanceand reliability. They are preferred by manyof the largest aircraft manufacturers andoverhaul facilities.

MAGNAFLUX manufactures penetrantmaterials, accessories and equipment,making us a one-stop shop. We areinvolved in the total process from start to finish, and produce our products toperform to the utmost of effectivenesswhen used together.

How to use

Zyglo® PENETRANTS

Page 3: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

8 www.magnaflux.com • 847.657.5300

Liquid Penetrant Classification Per AMS 2644

Penetrant Types:

Type 1 – fluorescent dye

Type 2 – visible dye

Penetrant Sensitivity Levels:Sensitivity level (fluorescent only)

1⁄2 – ultra low

1 – low

2 – medium

3 – high

4 – ultra high

Penetrant Methods:

Method A – water washable

Method B – post emulsifiable, lipophilic

Method C – solvent removable

Method D – post emulsifiable, hydrophilic

Developer Forms:

Form a – dry powder

Form b – water soluble

Form c – water suspendible

Form d – nonaqueous Type 1fluorescent (solvent based)

Form e – nonaqueous Type 2visible dye (solvent based)

Penetrant Inspection Method

Types of FLAWS likely to be encountered and their causes

Most will be service-caused cracks

• Overstress – caused by stressing part beyond its elastic limit

• Fatigue cracks – caused by repeated stress and relaxation of part.

• Corrosion cracks – caused by exposure to corrosive media or atmosphere.

Repair operations can also cause cracks

• Welding • Grinding• Machining• Heat Shrinkage• Leaks

Penetrant Method is usable:

• Where cracks are open to the surface.• On any material which is NOT excessively porous.• On any material which will not be harmed by chemicals

or procedures.

Part preparation and Cleaning• For penetrant method to work, defect must be clean and

open to the surface.

Cracks must be empty and dry for penetrant to enter.

• Ultrasonic cleaning is usually best method. • Alkaline cleaning may be applicable.• Steam cleaning may or may not work, depending on soil.• Parts must be dry before penetrant processing

Choice of Penetrant Method Depends On:

• Sensitivity required• Number of parts to be tested• Surface condition of part being inspected• Configuration of test specimen• Availability of water, electricity, compressed air, suitable

testing area, etc.

Materials used in Penetrant Testing Systems

Water-Washable Penetrants contain emulsifiers, which makesthem easily removable by a water rinse or wash.

• The most economical removal method• Fewer processing steps• Highly procedure dependent since over-washing

can occur• Not good for wide or shallow flaws• Effluent disposal may be a problem

Post Emulsifiable Penetrants are highly penetrating, oily fluo-rescent penetrants that are not soluble in water. These penetrantsmust be treated with an emulsifier before they can be removed bya water rinse or wash.

• Two methods of PE removal, hydrophilic (the most commonly used) and lipophilic

• Highly sensitive to very fine cracks• The ability to show wide, shallow cracks• Better control of removal process

Developers:Dry developers

• Are fluffy dry powders, used as received• Are not usable with visible penetrants• Parts must be completely dried before application

of developer• May be applied by spray, manual duster, dipping• Will produce small indications with little or no background• Dust masks may be required

Aqueous developers

• Are supplied as dry powders to be mixed with specified amounts of water. These powders are either soluble or suspended.

• Suspended developers need to be agitated • Parts do not need to be dried before application

Nonaqueous (solvent based) developers

• Are supplied premixed and ready to use• Applied only by spray• Are the most sensitive developers because solvent

redissolves and spreads penetrant• Are the most expensive developer type because of high

material cost and labor intensive application.

Which method and sensitivity is best for my application?

Since there are choices for developers, which one should I use?

Since each application is slightly different, we recommend you contactMagnaflux to help guide you through this selection process.

Page 4: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

9www.magnaflux.com • 847.657.5300

CLEAN AND DRY

APPLYPENETRANT

DWELL

WATER RINSE

AQUEOUS DEVELOPER

DRY

DWELL

INSPECTION

POST CLEAN

DRY

NONAQUEOUS DEVELOPER

DRY

DRYDEVELOPER

CLEAN AND DRY

APPLYPENETRANT

DWELL

WIPE

APPLY DEVELOPER

INSPECT

POST CLEAN

CLEAN AND DRY

APPLYPENETRANT

DWELL

APPLY REMOVER

AQUEOUS DEVELOPER

DRY

DWELL

INSPECTION

POST CLEAN

DRY

NONAQUEOUS DEVELOPER

DRY

DRYDEVELOPER

POST RINSE(CLEAN WATER)

PRE-RINSE

CLEAN AND DRY

APPLYPENETRANT

DWELL

WATER RINSE

AQUEOUS DEVELOPER

DRY

DWELL

INSPECTION

POST CLEAN

DRY

NONAQUEOUS DEVELOPER

DRY

DRYDEVELOPER

LIPOPHILICEMULSIFIER

DWELL

METHOD A WATER-WASHABLE

METHOD B LIPOPHILIC

METHOD DHYDROPHILIC

METHOD C SOLVENT REMOVABLE

Page 5: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

10 www.magnaflux.com • 847.657.5300

ZL-15B Water Washable Fluorescent Penetrant(Level 1⁄2 – Lowest sensitivity) Exhibits excellent washability for castings and rough surfaces.Approved Developers: ZP-4B, ZP-9F, ZP-5B & SKD-S2

ZYGLO (Method A) Water Washable Penetrants

Part #: Container Size:01-3159-40 5 Gallon Pail01-3159-30 20 Gallon Drum01-3159-45 55 Gallon Drum

ZL-19Water Washable Fluorescent Penetrant(Level 1 – Low sensitivity penetrant) Higher brightness and sensitivity than ZL-15BApproved Developers: ZP-4B, ZP-9F, ZP-5B & SKD-S2

Part #: Container Size:01-3263-40 5 Gallon Pail01-3263-30 20 Gallon Drum01-3263-45 55 Gallon Drum

ZL-60DWater Washable Fluorescent Penetrant(Level 2 – Medium Sensitivity)Exhibits excellent washability for castings and rough surfaces; and is typically used on castings, forgings, extrusions and roughmachined surfaces to find cracks, seams, laps, cold shuts, laminations and porosity.Approved Developers: ZP-4B, ZP-9F, ZP-5B & SKD-S2

ZYGLO Water Washable Penetrants are used to check for cracks in a wide range of sensitive applications. Our penetrants fluoresce a greenish-yel-low color under ultraviolet radiation. Use black light sources with peak wavelength of 365 nanometers such as MAGNAFLUX ZB-100F Fan-Cooled Black Light.

Part #: Container Size:01-3272-35 Case of 4 – 1 Gallon Containers01-3272-40 5 Gallon Pail01-3272-30 20 Gallon Drum01-3272-45 55 Gallon DrumAlso available in 16 oz. aerosol cans.

ZL-67Water Washable Fluorescent Penetrant(Level 3 – High Sensitivity)Provides an excellent combination of sensitivity/washability and is typically used on critical applications including investment castings, jet engine components, and highly machined surfaces to findcracks, seams and porosity.Approved Developers: ZP-4B, ZP-9F, ZP-5B & SKD-S2

Part #: Container Size:01-3274-35 Case of 4 - 1 Gallon Containers01-3274-40 5 Gallon Pail01-3274-30 20 Gallon Drum01-3274-45 55 Gallon Drum

ZL-56Water Washable Fluorescent Penetrant(Level 4 – Ultra High Sensitivity)Ultra-high sensitivity penetrant for critical applications. ZL-56 is a fluorescent, high sensitivity, water washable penetrant. ZL-56 is typically used on smooth, nonporous, highly machined surfaces to find cracks, seams, and scratches.Approved Developers: ZP-4B, ZP-9F, ZP-5B & SKD-S2

Part #: Container Size:01-3267-40 5 Gallon Pail01-3267-30 20 Gallon Drum01-3267-45 55 Gallon Drum

MAGNAG

LO

ZYGLO

SPOTCHECK

DARACLEAN

Page 6: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

11www.magnaflux.com • 847.657.5300

ZYGLO® (Method B, C, D) Post Emulsifiable Fluorescent Penetrants

The ZYGLO post emulsifiable fluorescent penetrants are used for a wide range of sensitive applications and are formulated to be impervious towater to assure against being over washed from defects. The MAGNAFLUX Post Emulsifiable Penetrants require the application of a lipophilicemulsifier or a hydrophilic emulsifier to render it washable with water. All of our penetrants are formulated for rapid separation from water for efficient clean up by coalescer, or charcoal filtration. Each penetrant fluoresces a bright greenish-yellow color under ultraviolet radiation. Use of ablack light source, with peak wavelength of 365 nanometers, such as the MAGNAFLUX® ZB-100F Fan-Cooled black light, is recommended.Each penetrant is formulated to produce heat stable fluorescent indications under normal drying conditions (140°F/60° C).

ZL-2CPE Fluorescent Penetrant(Level 2 – Medium Sensitivity) ZL-2C is typically used on castings, forgings, and extrusions, rough and machined surfaces to find cracks, seams, laps, laminations and porosity.Approved Developers: ZP-4B, ZP-9F, ZP-5B, ZP-14A & SKD-S2Approved Removers: ZR-10B, ZE-4B, SKC-S & SKC-HF

Part #: Container Size:01-3123-40 5 Gallon Pail01-3123-30 20 Gallon Drum01-3123-45 55 Gallon Drum

ZL-27APE Fluorescent Penetrant(Level 3 – High Sensitivity)ZL-27A is typically used on castings, forgings, and extrusions, rough and machined surfaces to find cracks, seams, laps, laminations and porosity.Approved Developers: ZP-4B, ZP-9F, ZP-5B, ZP-14A & SKD-S2Approved Removers: ZR-10B, ZE-4B, SKC-S & SKC-HF

Part #: Container Size:01-3187-35 Case of 4 –

1 Gallon Containers01-3187-40 5 Gallon Pail01-3187-30 20 Gallon Drum01-3187-45 55 Gallon DrumAlso available in 16 oz. aerosol cans.

ZL-37PE Fluorescent Penetrant(Level 4 – Ultra-High Sensitivity) ZL-37 is typically used on castings, forgings, and extrusions, rough and machined surfaces to find cracks, seams, laps, laminations and porosity.Approved Developers: ZP-4B, ZP-9F, ZP-5B, ZP-14A & SKD-S2Approved Removers: ZR-10B, ZE-4B, SKC-S & SKC-HF

Part #: Container Size:01-3188-35 Case of 4 – 1 Gallon Containers01-3188-40 5 Gallon Pail01-3188-30 20 Gallon Drum01-3188-45 55 Gallon Drum

Part #: Container Size:01-3137-40 5 Gallon Pail01-3137-45 55 Gallon Drum

ZL-4CWater Base Fluorescent PenetrantZL-4C is typically used on plastics and ceramics to find cracks. ZL-4Cis also used as a leaker penetrant to detect through leaks.

ZL-4C is a fluorescent, water base penetrant. ZL-4C is soluble in water and can be diluted, but is generally used as supplied or from 1:1 to 1:2 in water. ZL-4C contains no petroleum base solvents. ZL-4C fluoresces a greenish-yellow color under ultraviolet radiation of365 nm, such as supplied by the MAGNAFLUX® ZB-100F fan-cooledblack light.

ZYGLO® Water Base Fluorescent Penetrant

ZYGLO® PENETRANT PENFluorescent PenetrantFor small areas or parts and for reworked inspection without the overspray mess from aerosol cans containing penetrant. Contains ZygloZL-37 Fluorescent Penetrant (ultra high sensitivity).

Part #: Container Size:01-3188-75 12 Pens/Case

Page 7: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

12 www.magnaflux.com • 847.657.5300

ZYGLO® Additive

ZL-5Fluorescent Water Additive for Leak DetectionZL-5 is a dry powder fluorescent organic material used as an additive for the detection of leaks in pressure vessels, storage tanks,radiators and other liquid system containers. ZL-5 is water-soluble and produces fluorescence when using a black light, (such as the MAGNAFLUX® ZB-100F fan cooled black light) at 365 nanometers.

ZYGLO® Developers

ZP-4BDry PowderZP-4B is a free-flowing, white, fluffy powder used as a dry powderdeveloper for ZYGLO penetrants. ZP-4B is supplied ready to use. ZP-4B forms a thin film on parts which enables it to enhance indications of ultra fine discontinuities. ZP-4B’s high purity allows it to be used in applications demanding purity.

Part #: Container Size:01-3141-57 1 lb. Container01-3141-63 5 lb. Container

Part #: Container Size:01-3328-25 12 – 1 pt Cans01-3328-69 10 lb. Container01-3328-75 20 lb. Container

ZP-5BWater SuspendibleZP-5B is a white powder which is to be dispersed into water. ZP-5B disperses quickly to form an opaque white suspension. Must be continually agitated during use to ensure uniformity of mix as developer will settle out on standing. ZP-5B forms a uniform white coating which enhances fluorescent indications formed by ZYGLOpenetrants. At higher concentration, ZP-5B forms an opaque white coating which provides contrasting background for SPOTCHECKindications.

Part #: Container Size:01-3341-81 25 lb. Container

ZP-9FNon-AqueousZP-9F is a ready-to-use suspension of white developing particles in a fast drying solvent. ZP-9F produces an opaque white coating,which provides an excellent contrasting background for SPOTCHECK or ZYGLO penetrant indications. ZP-9F is specially formulated to be low in sulfur and halogens and contains no chlorinated hydrocarbons.

Part #: Container Size:01-3354-40 5 Gallon PailAlso available in 16 oz. aerosol cans.

ZP-14AWater SolubleZP-14A is a white free-flowing powder, which dissolves in water toform a clear, colorless biodegradable developer solution. ZP-14A isused as a general purpose water-soluble developer for the enhance-ment of indications formed by ZYGLO penetrants. ZP-14A produces a uniform white porous coating when it dries. The developer film is easily removed in post inspection cleaning by a water spray. Once the developer bath has been made up, no in-use agitation is required to maintain developer uniformity.

Part #: Container Size:01-3381-75 20 lb. Container01-3381-89 50 lb. Container

ZYGLO® Lipophilic Emulsifier (Method B)

ZE-4BEmulsifierZE-4B is a reddish, slightly viscous liquid used for the emulsification of ZYGLO PE penetrants. ZE-4B is a general purpose emulsifier with a moderate rate of action. ZE-4B can be used in open tanks due to its low volatility and high flash point.

Part #: Container Size:01-3546-40 5 Gallon Pail01-3546-30 20 Gallon Drum01-3546-45 55 Gallon Drum

ZYGLO® Hydrophilic Emulsifier (Method D)

ZR-10BRemoverZR-10B is a pinkish, slightly viscous liquid. ZR-10B is a 100% activeconcentrate, which is diluted in water when used as an emulsifier for ZYGLO PE penetrants. ZR-10B is very low in sulfur, chlorine, and sodium content.

Part #: Container Size:01-3620-40 5 Gallon Pail01-3620-30 20 Gallon Drum01-3620-45 55 Gallon Drum

Page 8: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

13www.magnaflux.com • 847.657.5300

Part # Includes600047 ZB-100F Black Light 115v

1 can of ZL-27A PE Fluorescent Penetrant, 1 can of ZP-9F Developer, 2 cans of SKC-S Cleaner, heavy duty wiping cloth, paint marker, Scrubs™ hand towels, portable plastic case and instructions

600045 ZB-100F (230v–60 hz)

621304 ZB-100F (220v–50 hz)

ZA-70 Kit (16 oz.)115v ZB-100F Black Light

Part # Includes01-3930-48 2 cans of ZL-27A PE Fluorescent Penetrant,

2 cans ZP-9F Developer, 4 cans of SKC-SCleaner, Heavy Duty Wiping Cloth, Paint Marker, Scrubs™ Hand Towels, Portable Plastic Case and Instructions.

ZA-70R (16 oz.)Refill Kit

MAGNAFLUX® PeneCert™ ProgramRequired Tests and Frequency (From E 1417–05E1)Tests Frequency ParagraphPenetrant ContaminationA Daily 7.8.2.1Penetrant Brightness Quarterly 7.8.2.2Water Content: Water Based Penetrant (Method A) Weekly 7.8.2.3Water Content: Non-Water-Based Penetrant (Method A) Monthly 7.8.2.4Lipophillic Emulsifier Water ContentB Monthly 7.8.2.5Hydrophillic Emulsifer ConcentrationB Weekly 7.8.2.6Dry Developer ConditionB Daily 7.8.2.7Aqueous Developer Contamination: Soluble and Suspendable Daily 7.8.2.8Aqueous Developer Concentration: Soluble and Suspendable Weekly 7.8.2.9Penetrant System PerformanceC Daily 7.8.3Water Washable Penetrant Removability As required per 7.8.3 7.8.3.2Emulsifier Removability As required per 7.8.3 7.8.3.3Comparative Penetrant Sensitivity As required per 7.8.3 7.8.3.4Black Light IntensityB Daily 7.8.4.1Black Light Integrity Weekly 7.8.4.1Special UV Lighting Daily 7.8.4.2Visible Light Intensity Weekly 7.8.4.3Light Meter Calibration Semi-Annually 7.8.4.4Inspection Area CleanlinessA Daily 7.8.4.5Inspection Light Ambient Light Intensity Quarterly 7.8.4.5Water Wash Pressure CheckA Start of each working shift 7.8.4.6Water Wash Gage Calibration Semi-Annually 7.8.4.6Water Wash Temperature CheckA Start of each shift 7.8.4.6Water Pressure Gage Calibration Semi-Annually 7.8.4.6Drying Oven Calibration Quarterly 7.8.4.7

A Need not be recorded.B The maximum time between verifications or checks may be extended when its substantiated by technical

data and approved by the Cognizant Engineering Organization.C Not required for Method C examinations.

Paragraph numbers refer to “PeneCert Procedures” document.

Paragraph Part No. Description Number

751401 Water Wash Penetrant System All

751402 PE/PR Penetrant System All

751403 Water Wash Penetrant Only Tests 5.1-5.7

751404 PE/PR Penetrant Only Tests 5.1-5.4

751413 Viscosity 5.3

751409 Fluorescent Brightness Test 5.4

751411 Water Wash Penetrant Water Content Only 5.5

751410 Water Wash Penetrant—Removability & Sensitivity Tests 5.6-5.7

751405 Emulsifier (Remover) Test Only 6.1-6.3

751412 Emulsifier (Remover) Water Content Only 6.3

751406 Dry Developer Test Only 7.1 - 7.3

751407 Aqueous Developer Test Only 7.1, 7.2, 7.4, 7.5–7.7

751408 PE/PR System—Removability & Sensitivity Test 8.1-8.2

751415 Water Wash or PE/PR—Penetrant Removability Test Only 5.6 or 8.1

751416 Water Wash or PE/PR Penetrant—Sensitivity Test 5.7 or 8.2

751414 TAM Panel Recertification 9.1

The MAGNAFLUX PeneCert™ testing service providescustomers the certification of compliance of certainused materials (ZYGLO Penetrants, Removers,Emulsifiers, Developers, etc.) to various standards, in one sample per test.

Page 9: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

14 www.magnaflux.com • 847.657.5300

ZYGLO® Specification Conformance Chart

Specification ZL-15B ZL-19 ZL-60D ZL-67 ZL-56 ZL-2C ZL-27A ZL-37

Water Washable Penetrants Post Emulsifiable Penetrants

NAVSEA T9074-AS-GIB-010/271 x x x x x x x x

MIL-STD-2132 x x x x x x x x

AECL x x x x x x x x

AMS-2644 x x x x x x x x

AMS-2647 x x x x x x

ASME B & PV Code, Sec. V x x x x x x x x

ASTM E 165 x x x x x x x x

ASTM E-1417 x x x x x x x x

Boeing BAC 5423 PSD 6-46 or 8-4 x x x x x x x x

Honeywell EMS 52309 x x x x x x x x

General Electric P3TF2 x x x x x x

General Electric P50YP107 x x x x x x x x

Boeing PS-21202 x x x x x x x x

Pratt & Whitney FPM x x x x x x

Emulsifiers & Removers Developers

NAVSEA T9074-AS-GIB-010/271 x x x x x x x x

MIL-STD-2132 x x x x x x x x

AECL x x x x x x x x

AMS-2644 x x x x x x x x

AMS-2647 x x x x x x x x

ASME B & PV Code, Sec. V x x x x x x x x

ASTM E 165 x x x x x x x x

ASTM E-1417 x x x x x x x x

Boeing BAC 5423 PSD 6-46 or 8-4 x x x x x x x x

Honeywell EMS 52309 x x x x x x x x

General Electric P3TF2 x x x x x x x x

General Electric P50YP107 x x x x x

Boeing PS-21202 x x x x x x x x

Pratt & Whitney FPM x x x

Specification ZE-4B ZR-10B SKC-S SKC-HF ZP-4B ZP-14A ZP-5B ZP-9F

Page 10: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

15www.magnaflux.com • 847.657.5300

Hand Sprayers

Water Spray GunFor rinsing either water-washor post-emulsifiable penetrants

Coarse spray

Part #: 520090

Dry DeveloperSpray Gun

Provides light, even developer coating

Uses shop compressed air(dry)

Features mix, jet and spreadcontrols

Two quart capacity

Part #: 521339

Hydro-Wash SprayGun

For water rinsing of parts

Air injection boosts velocity,permits faster rinsing withless water usage

Useful with low or fluctuating water pressure

For spray distances overthree feet or when rinsinghollow or rough surface parts

Part #: 518992

NOTE: Ensure compatibility with governing specification thatinspection work must meetbefore using this technique.

Portable PressureSprayer

Lightweight pressure sprayer for spot application of penetrants, developersand cleaners

Includes interchangeable nozzles for mist or pin spray

Chrome-plated solid brassconstruction, one-quartcapacity

Pressurize with compressedair to a maximum of 200 psi

Part #: 195260

Water Pressure Gauge and Regulator

Water PressureGauge

For use with water regulators

Part #: 513759

1⁄2 I.P.S. Water PressureRegulator

3⁄4" I.P.S. (#513757) and 1" I.P.S. (#513758) also available outlet ports

Adjustable from 2 psig to125 psig

Part #: 513756Regulators and gauges for applications requiring strict water pressure control.

zyglo® accessories

Page 11: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

16 www.magnaflux.com • 847.657.5300

Automatically mix ZR-10Bhydrophilic emulsifier (remover)with spray rinse water to combineemulsification and rinsing, leavingonly a brief final wash. Three-wayvalve permits selection of wateronly or water plus remover spray.

Hydrophilic Emulsifier Injector Kit

Dosatron Model MeteringInjector

For close range rinsing atspray distance up to 4'

Externally adjusted

Extremely accurate injectionrates of 1–5%

Flow rates up to 11 GPM

Part #: 609032

Test Blocks

Aluminum TestBlock (for sensitivity)

Cracked aluminum blockcompares sensitivity of different penetrants or sensitivity of new and oldpenetrants

Complies with ASTM E165;ASME Boiler and PressureVessel code

Part #: 14755

Stainless Steel TestBlock (for washability)

Monitors washability of water-wash or post-emulsified penetrants

Grit-blasted rough surfaceretains “background” whenwashability is impaired

May be used repeatedly if thoroughly cleaned after each use

Complies with ASTM E165

Part #: 154400

Comparators

Crack ComparatorGeneral purpose crack comparator, 0.005" to0.125" increments

Part #: 514048

TAM CrackComparator

0.010" to 0.180" increments

Meets Pratt & Whitneyrequirements (P&W reference: TAM 135273)

Part #: 514050

Metric CrackComparator

General purpose crack comparator, 0.2mm to3.0mm increments

Part #: 514049

Hydrophilic Emulsifier Injector Kit

Test Panels

NiCr PanelsThe NiCr penetrant test panels are ideal pene-trant sensitivity comparators. The panels areavailable with crack depth of 10, 20, 30, and 50microns and come in matched pairs. Individualcrack sizes or a complete kit of all four sizes areavailable.

Having matched pairs enables studies of theeffects of process changes as compared to astandard process, or used material changes vsfresh material. The panels are ideal for monitoringfluorescent penetrant (ZYGLO) lines.

Part #: Description:506251 One Pair of NiCr

10 micron panels506252 One Pair of NiCr

20 micron panels506253 One Pair of NiCr

30 micron panels506254 One Pair of NiCr

50 micron panels184400 NiCr Panel Set contains one

pair of 10, 20, 30, and 50micron crack size

Page 12: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

17www.magnaflux.com • 847.657.5300

Test Panels

TAM Panel4" x 6" stainless steel panelmonitors both sensitivity andwashability of penetrantprocess

Includes a rough surface for washability testing, plus a polished chrome sectionwith 5 “star” shaped defectsranging in size from coarse to extremely fine

Pratt and Whitney TAM#146040

Part #: 198055

Process Control Accessories

HydrometerUses specific gravity read-ings to monitor water based developer concentration andmaintain optimum developerperformance

Part #: 5857

Refractometer Optical device used for measuring concentration of hydrophilic removers in water

Includes chart to convert to percent concentration for ZR-10B ZYGLOhydrophilic removers

Part #: 513829

Purified PenetrantWiping Cloths

For use when specificationsrequire certified pure wipingcloths

Includes dispensing rack andmanufacturer’s certification

Case of 12 rolls

Part #: 512302

Round Wire Basket Enables processing ofnumerous small parts at one time

12" diameter 3⁄4" mesh

Sturdy construction withnylon-coating to protect parts

Part #: 1962

TAM Panel Cleaning KitA table-top (the size of atoaster) Ultrasonic cleaningunit with heater and timer

One gallon of MagnaVualkaline cleaner concentrate

Complete instructions.

Part #: 01-7500-00

Page 13: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

18 www.magnaflux.com • 847.657.5300

ZA-1633PenetrantProcessingInspectionEquipmentEach of the three models aredesigned for a specific testingmethod. Because the order of usevaries with different penetrant materi-als, the units must be carefullyordered to fit the specific application.

Configured for

Water Washable Penetrant System (Method A)

Number of Stations: Six (Penetrant Station, Drain Station, Wash Station, Dryer Station, Developer Station, Inspection Station)

Configured for

Post Emulsified Lipophilic Penetrant System(Method B)

Number of Stations: Eight (Penetrant Station, Drain Station,Emulsifier Station, Rinse Station, Drain Station, Dryer Station,Developer Station, Inspection Station) For any other voltage, please call MAGNAFLUX.

Configured for

Post Emulsified Hydrophilic Penetrant System(Method D)

Number of Stations: Nine (Penetrant Station, Drain Station, Pre-Rinse Station, Drain Station, Remover Station, Rinse Station, Dryer Station, Developer Station, Inspection Station)For any other voltage, please call MAGNAFLUX.

Optional FeaturePart #: Description:609178-P Lid, Tank

NOTE: Dynamic Cloud (Dry Developer) design with dust collection anda 2.5 gallon pressure pot is now available.

Model shown is configuredfor Water Washable.

Available Voltage

220V/440V-50 hz230V/460V-60 hz

zyglo® equipment(formerly ZA-28)

Page 14: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

19www.magnaflux.com • 847.657.5300

ZA-1227 Compact PenetrantProcessing InspectionEquipmentEach of the models are designed for a specific testing method. The order of usevaries with different penetrant materials, so the units must be carefully ordered to fit the specific application.

ZA-1227 CW Cleaning Station IncludedStandard Features Include:

Cleaning Station with pump agitation and heater.

Dynamic Cloud Developer Chamber with a two gallon pres-sure pot and foot switch for the dispensing of our ZP-4B DryPowder Developer, 5" diameter viewing window in cover. Built in dust collector with air filter.

Inspection Booth with ZB-100F portable black light mountedon top center of booth for fixed inspection or hand held inspection.

The CW is our cost effective, integrated manual system forprocessing small to medium parts and has:

Welded Steel Frame,

304 Stainless Steel Tanks,

120 Volts/60 hz/1 Phase,

Overall Length 97"

ZA-37 CW has Seven Stations:Cleaning Station with pump agitation and heater, Pre-Rinse Tank withDwell Tray, Penetrant Dip Tank, Final Rinse Station with Dwell Tray,Dryer with 1500 watt heater — thermostat control, Dynamic CloudChamber, Inspection Booth (with portable ZB-100F)

Model shown is CW Configuration.

Dryer Station, Dynamic Cloud Developer Station, Inspection Station,shown above.

Configured for

Water Washable Penetrant System (Method A)

Number of Stations: Five (Penetrant Station, Rinse Station,Developer Station, Dryer Station, Inspection Station)

Configured for

Post Emulsified Lipophilic Penetrant System(Method B)

Number of Stations: Six (Penetrant Station, Emulsifier Station, Rinse Station, Developer Station, Dryer Station, Inspection Station)

Configured for

Post Emulsified Hydrophilic Penetrant System(Method D)

Number of Stations: Seven (Penetrant Station, Pre-Rinse Station,Remover Station, Final Rinse Station, Developer Station, Dryer Station,Inspection Station) For any other voltage - please call MAGNAFLUX

Optional Features for Penetrant System

Part #: Description:609178RE-P Tank Lid608363 Inspection Station (Stand Alone)

Dimensions of first six stations:121⁄2" Wide x 27" Long x 17" Deep

Dimensions of Inspection Booth: 163⁄4" Wide x 27" Long x 14" High Viewing Area

Available Voltage

115V-50/60 hz230V-50/60 hz460V-50/60 hz

(formerly ZA-37)

Page 15: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

MAGNAG

LO

ZYGLO

SPOTCHECK

DARACLEAN

ZB-100F Portable Black Light System produceslongwave ultraviolet light at 365nanometers, providing optimum fluorescence in MAGNAGLO® andZYGLO® testing materials.

100 watt black light with transformer, cords, GFCI and plug.

Built-in fan keeps light cool-to-the-touch.

Running temperature <85˚F.

Typical output 5,000 µW/cm2.

#600004 portable unit includes carrying base and stand for storageof cord.

#600005 Hand-held unit similar to #600004, except no carrying base provided.

BenefitsOne significant feature that separates the ZB-100F from otherblack lights – it has a built-in, quiet-operating fan located at therear of the lamp housing.

The advantage of this design feature is obvious – dramaticallyreduced running temperature. In practical terms, the fan-cooled ZB-100F means more comfort and safety for operators pluslonger bulb life.

Because black lights are often hand-held during fluorescentinspections, the heat they create is an important consideration.The typical running temperature of the ZB-100F is less than 85degrees Fahrenheit, so it does not significantly raise the ambienttemperature around the operator, nor is it a safety concern.

The ZB-100F also shares all of the features of the ZB-100, ourmost popular NDT black light.

Polycarbonite bezel helps keep operators’ hands away fromlens glass during use

Cord-through-handle design reduces operator fatigue,improves balance and provides greater safety

Fiberglass-reinforced handle always stays cool

Tough aluminum housing withstands rugged use

Recessed lens design protects lens and bulb from damage

45www.magnaflux.com • 847.657.5300

Technical Specifications for ZB-100FPower Supply: 115V/50 or 60 hz/1ph

(P/N600004)

115V/60 hz/1ph(P/N600005)

Current Draw: 1.9 amps

Typical Visible Light: 10 Lux or 1 foot candle @15" (38 cm)

Bulb: 100 watts

Running Temperature: 85 °F (30 °C) @ 70 °F 13 amps @230 VAC

Weight—Hand Lamp: 3 lbs. (1.4 kg)

Weight—Hand Lamp with Transformer: 12.5 lbs. (5.7 kg) Control Unit

Lamp to Transformer: 10 ft. (3.1 m) Cable Unit

Main Cable Supply: 12 ft. (3.7 m) with GroundFault Protection

UV Intensity meets industry and military standards @ 15" (38 cm)

part # 600004

black lights

Page 16: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

Part #: Voltage:600004 115v/60 hz/1ph with carrier/stand600005 115v/60 hz/1ph 600068 Carrier/stand for ZB-100F621312 230/60/1 with carrier/stand 621311 220v/50/1 with carrier/stand621109 Carrying case for ZB-100F

ZB-100F MB – MAG Shot Black LightWe have taken our ZB-100F Fan-Cooled black light and added the convenience of energizing your Power Packs or Wet BenchesREMOTELY, when checking for cracks in extra long parts.

Our ZB-100F MB has a remote button integrated into the handle of the black light to eliminate the need to continuously return to the MPI Unit to initiate a mag shot.

Uses Medium Base Bulb (Part #: 507320)

Part #: 600086

ZB-100F and ZB-100 Hand-Held Black Lights 100 watt, hand-held model includes transformer, cords, GFCI and plug.

115v or 230v

Typical intensity @15" (38 cm): 4300 Microwatts/cm2

Polycarbonite bezel protects operators from burns

Fan-cooled model reduces running temperature <85˚FKeeps light cool to the touch

Uses Medium Base Bulb (Part #: 507320)

Part #: Voltage:600000 115v/60 hz/1ph 600001 230v/60 hz/1ph 600002 230v/50 hz/1ph 600003 115v/50 hz/1ph047685 Carrying Case for ZB-100

ZB-150 FSB Self-Ballasted Black LightFor Portable Inspections!

No Transformer

Fan-Cooled

Ergonomic Grip

Uses 150W Self-Ballasted Replacement Bulb (Part #: 519296)

ZB-240 Cool Max Fluorescent Overhead UV Light Fixture

Y bracket mounting makes it easy to install

Protective lens is impact-resistant and hinged for easy cleaning

Cool fluorescent operation, energy-efficient design, and easy bulb replacement

Bulb life estimated at 8,000 to 10,000 hours

Could replace large “flood style” units which generate excessive heat

Uniform light intensity allows for a larger inspection area

Much less expensive than the typical “flood style” lamp

Uses 4 ft. (1.2 m) Tubular Black Light Bulb (40 w) (Part #: 622048)

Part #: 621135 115v/60 hz

ZB-100 Black Light

46 www.magnaflux.com • 847.657.5300

ZB-100F Hand-Held, Fan-Cooled Black Light

Part #: 621509 115v621563 230v

40W Tubular Black Light Bulb

4 foot (1.2 m), 40 watt, replacement for theZB-240 Cool Max Light Fixture.

Part #: Description:622048 Package of 3 bulbs

Page 17: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

Black Light Bulbs

100W Medium Base Bulb

100 watt spotlight bulb,replacement for ZB-100 and ZB-100F models and all other MAGNAFLUX 100watt lamps made after May 1982.

Note: The socket base of the507320 is similar in size to that of a table lamp socket.

Part #: 507320

Filters

Smooth Filter Glass For use with ZB-100 and ZB-100F models

Part #: 519227

Fluted Filter GlassSimilar to # 519227, but fluted for a more diffused output pattern

Part #: 3901

U-V Absorbing Spectacles

UV-AbsorbingSpectacles

Reduces eye fatigue from exposure to UV light emission

Part #: 506249

100W Ad Medium Base

100 watt spotlight bulb, replacement for MAGNAFLUX 100W lampsmade BEFORE May 1982.Replacement of currentSpectronics Lamps.

Note: The socket size of the Ad Medium Base Bulb is largerthan that of the Medium basebulb (507320).

Part #: 1914

47www.magnaflux.com • 847.657.5300

black light accessories

150W Self-Ballasted Bulb

Built in ballast, 150 watt(Used in our ZB-100FSBBlack Light System)

Note: The socket base of the519269 is similar in size to that of a table lamp socket.

Part #: 519296

Page 18: qnde magnaflux liquide penetrant zyglo catalogue · Test Labs NDT Inspections ... Liquid Penetrant Classification Per AMS 2644 ... Water Washable Fluorescent Penetrant (Level 1 ...

Black Light Mounting Hardware

ZB-100/100F Side-Mount Assembly

Bracket mounts on side ofhorizontal units

Movable pivot arms foradjustment of black light

Light assembly lifts from fixture for portable use

Part #: 600029

Modular BlackLight MountingSystem

May be configured forwet bench mounting,tabletop, and overheadlighting

Infinite positioning capabilities

Easy lock and holdhardware

Call Magnaflux for configuration andpart numbers to fit your need.

Side mounts, tabletop assemblies and wall brackets facilitate the use of black lights in a variety of applications.

ZB-100/100FTabletop MountAssembly

Tabletop mount assembly

Movable pivot arms foradjustment of black light

Light assembly lifts from fixture for portable use

Part #: 600026

Light Meters

Digital White Light MeterAccurately measures visible light by footcandles and lux

Includes meter and white light meter sensor (permanentlyaffixed to meter by coiled cord)

Calibrated/Certified for NDT use

Meter comes with battery and carrying case

Part #: 622338

Digital Black LIght MeterAccurate digital readout of black light intensity, tuned at 365nanometers (microwatts/cm3)

Includes meter and permanently affixed black light sensor

Calibrated/Certified for NDT use

Meter comes with battery and carrying case

Part #: 622339