QLogic FabricCache™ 10000 Séries Adapter
2-7-13v1
• Fibre Channel Adapters• Multiprotocol Storage Controllers• Enterprise Application Acceleration (Cache Optimized SAN)• 10/40/100Gb Ethernet and Converged Networking
QLogic Company Highlights
2
• ~1,100 employees worldwide• Development centers in U.S. and India• Manufacturing (CM) in China and Malaysia• Fulfillment centers in U.S., Asia, and Europe
Growing global presence
• Over 15 million FC Adapter Ports Shipped• Most Established, Proven, Pervasive Storage Stack in the Industry• Strong IP, Expertise in Storage Networking• Growing Market Opportunities in Enterprise Application Acceleration
Significant Competitive Advantages
Leader in Key Market Sectors
58%
22%
11% 9%
Engineers Sales G&A Operations
New Acquisitions
3
• Brocade Fibre Channel and Converged Network Adapters• 8Gb FC• 10GbE FCoE• 16Gb & 10GbE Fabric Adapter
• Broadcom NetXtreme II• 10GbE family• 40GbE currently under design reviews with all major server OEMs• 100GbE on roadmap
QLogic “New” BR Adapters Product Summary
4
QLogic815/825HBA
QLogic1020CNA
• 8/4/2 Gbps FC• Single and dual port• 1600 MB/s, 500K IOPS/port• 1st Generation ASIC (Crossbow)
• 10 Gbps CEE for IP and FCoE• Dual port• Copper (active twinax) and optical• 2nd Generation ASIC (Catapult-1 aka Cat-1)
QLogic OEMMezzanine
• Brocade 1007: IBM CNA• Brocade 1741M: Dell CNA• Brocade 1867: IBM 2-port Fabric Adapter• Brocade 1869: IBM 4-port Fabric Adapter
QLogic1860Fabric Adapter
• 16/8/4/2 Gbps FC, 10GbE & FCoE• AnyIO™ single and dual port• 3200 MB/s, 500K IOPS/port• 3rd Generation ASIC (Catapult-2 aka Cat-2)
Broadcom HP
5
Broadcom Dell
6
Broadcom IBM
7
For additional Information go to:http://go.broadcom.com/IBM
QLogic Across the Data Center
Fibre Channel Adapter
Ethernet & iSCSI Adapters
Converged Network Adapter
8
Targets
Stackable Switches
iSCSI Array Targets
Fibre Channel Array Targets
Fibre Channel & Converged Blade Switch Modules
Fibre ChannelEthernet & iSCSI
Converged
Adapters & ASICs
Blade Modules
Fibre Channel Switches
Converged Array Targets
Shared Cache
Caching Adapters
FabricCache Adapters
Fibre Channel SAN
Converged Switching Modules
ConvergedEthernet
Server Based Cache
Accelerates applications
The I/O Performance Gap
9
TIME
PERF
ORM
ANCE
GRO
WTH
AREAL DENSITY SPINDLE SPEED
MODERATE GROWTH
ENORMOUS GROWTH
MORE POWERFUL PROCESSORS
MECHANICAL DRIVES
PROCESSORS
• Performance hungry business critical applications
• Demanding more transactions and less waiting
Applications
• Mechanical HDDs and array controllers can’t keep up
Storage
FLASH MEMORYDEVICES
Solving the I/O Performance Gap
PROs
• Easy to manage; shared
• Simple to implement
• Improved I/O performance
Array Networks Servers
PROs
• Centralized cache
• Shared cache by all servers
• Can cache network storage
PROs
• Critical data close to applications
• Improved storage performance and utilization
• Offloads Storage Network
Storagecache / tier
Cachingappliance
Servercache
CONs
• Distance from server processor (latency)
• Limitations of storage array controllers
• Potential SAN bottleneck
CONs
• Single point of failure
• Appliances can be expensive
• Potential SAN bottleneck
CONs
• Complexity & dependencies
• Cached data is captive in server “DAS SSD”
• Clusters not supported
Server-based Caching 1.0
Enterprise Application Acceleration2.0 Unleashes Performance for More Applications & Vast SAN Installed Base
11
• Captive to single server
• Incremental drivers and management
• No cluster support
• Breaks shared data model
• Separate SAN adapter required
Cache as shared SAN resource
Clustered environments
Needed for 2.0
Utilize existing drivers and management framework
Simple/non-disruptive to deploy
Maintain existing SAN architectural rules
Support virtualization (multi-server)
Shared performance acceleration. Simple and seamless integration.
QLogic FabricCache QLE10000 Adapter
12
Easy, Intuitive Interface Plug-ins for Hypervisor and Management Frameworks
Same Standard HBA Driver
Open API
Powerful Expert
Interface
QLE10522-CQLE10542-C
200GB PCIe400GB PCIePCIe slot for power
8Gb Dual-port FCCaching Engine• DDR memory• 4 Core SOC
Shareable Enterprise SLC flash
SSD HBA Operating System Driver
Plug-Ins
1st in a new generation of
GUI CLI
C:/flush_cache
API
Logically appears as a single standard adapter
SANCore
SANLUNs
SANCache
QLogic FabricCache QLE10000 Adapter Differentiated Functionality
13
1. Consolidate with a combined Fibre Channel adapter & cache solution
2. Simplify with transparent cache
3. Share cache among clustered servers and applications
Application
HBA Driver
Shared application performance acceleration for the SAN
Consolidate w/ a Combined Fibre Channel Adapter & Cache SolutionUnique to FabricCache
14
Caching & I/Omanagement Flash & SSDsSAN Adapter
FabricCacheSolution
Unequaled Storage Networking Heritage:
• Field proven protocol stacks
• Over 14 million ports in use
• Trusted tier-1 OEM supplier
Ground Breaking Innovation:
• HBA with cache integration
• Patent-pending SAN-based cache sharing
• Combined with COTS Flash Technology
Anatomy of the FabricCache 10000 Series Adapter
Simplify with Transparent CacheUnique to FabricCache
15
Application
Filter Driver / Agent
HBA Driver SSD Driver
Application
HBA Driver
1.0 Captive Server-Based SSD - Drivers and management for caching adapter must be installed and managed
2.0 QLE10000 adapter solution - Transparent cache with single, standard driver
Same standard HBA driver. No changes needed. Seamless integration.
2.0 QLE10000 Adapter Solution
Transparent cache is shared by all servers. All SAN LUNs are available to all servers.
1.0 Captive Server-Based Cache
Cache is DAS captive to one server. Each SAN LUN is captive to one server.
Share Cache Among Clustered Servers and ApplicationsUnique to FabricCache
16
SANCore
SANCore
SANLUNs
SANLUNs
SANCache
DASSSD
Performance Benefits for more applications
User requirements
• Cluster support is needed
• Node failover with warm cache
• Latency is critical (<1ms)
• Storage management
• Exponential growth in database sizes and active data sets
User requirements
• Support for vMotion maintaining warm cache
• Faster time-to-data means more VMs per server
• Virtualize business-critical applications & workloads
• Weather VDI boot storms
User requirements
• Support for clustering
• Faster response times
• Small block transactions
• Mailbox sizes are growing
• Mobile users drive 4x the requirements
Enterprise Application Requirements: Optimize Time to Data
17
Hypervisor & VDI Database Collaboration
Oracle RAC Cluster 82% Faster Response Time
18
87% reduction in demand of array (disk IOPs)
57% reduction in average transaction response
82% cut in peak transaction response
2-Node RAC 11gR2 (11.2.0.3)Intel Xeon E7 servers
Dual 6-core processors, 198GB RAMQLE10000 SSD HBA
146GB Pillar Axiom SAN Storage with 15K RPM HDDs1000 Concurrent Users
Frequently accessed Tempdb, Index and Log files cached on
the SAN cache
Less frequently accessed data stored on high-availability SAN LUN
OS
RAC Instance 1
OS
RAC Instance 2
SANCore
SANLUNs
SANCache
Server Virtualization Cache Stays Warm, Performance Stays High
19
Frequently accessed files cached on a high- performance, SAN cache
Live VM migration without refilling cacheSupports automation such as DRS
OSApp 2
Hypervisor
OS OSApp 1 App 2
Hypervisor
OS OSApp 3 App 4
Less frequently accessed data stored on high-availability SAN LUN
Demo
Titusville Area School District
• Security patches and application updates were difficult to install in every individual device, which put the district at risk from malware.
• The district turned to Cross IT Services & Solutions, LLC, a QLogic Advanced Solutions Partner specializing in virtualization technology and the education market, to help develop and implement a plan.
The Challenge
• The Titusville IT team launched a virtual desktop initiative and realized that architecting a district-wide deployment took more resources than they had in-house.
The Solution
• Five rack mounted Dell R815 rack servers
• Five QLogic QLE10522 FabricCache adapters – one in each
server
• Two QLogic SB5802 8Gb Fibre Channel stackable switches
• Two JetStor SAS 724iFD 24-bay RAID Arrays, each with four
200GB solid-state drives & twenty 600 GB hard drives, for
25.6TB of storage capacity
• VMware® View 5.2
The Solution
8Gb Fibre Channel
AC&NC JetStor® SAS 724iFD RAID Arrays - 25.6 TB
QLE10522
QLE10522
QLE10522
QLE10522
QLE10522SB5802v Switches
SANCore
SANLUNs
SANCache
FabricCache QLE10000 Summary
27
Consolidate with a combined Fibre Channel adapter & cache solution
Simplify with transparent cache
Share cache among clustered servers and applications
No Changes to existing SAN infrastructure, SW drivers or management framework
Enterprise Application Acceleration for single and clustered multi-server virtualized environments
Application
HBA Driver
Survey
VMUG 201428