Pressure Vessel Engineering Ltd.120 Randall Drive, Suite B
Waterloo, Ontario, Canada
N2V 1C6
Tel. 519-880-9808
Fax 519-880-9810
www.pveng.com
PVEng
Page 1 of 2
This document and any information contained herein are considered confidential and may not be used or disclosed except in accordance with any agreements made with or by PVEng.
Introduction Identify company and full address; identify product and part number; list date completed and location of test.
This report summarizes the results of the proof test completed for: Company: XXX
Product: XXX Location: XXX Date: XXX Setup Identify set-up, indicate how system was displaced of air, identify how pressure was introduced, reference applicable photos / drawings / documents.
The “Cooler Discharge Tube” was assembled with mating ISO 6162-1 caps on each end
¼” NPT ports were provided on each cap to allow for pressure line and air escape
A calibrated gauge was plumbed in the pressure line to monitor pressure throughout the test.
Water was introduced to the system to displace all air
The end opposite the pressure connection was plugged to seal the system
Pressure was incrementally raised until failure (see results below) Please refer to attached photos.
Gauge (ASME VIII-1 UG-102) Identify gauge used including size, pressure range, calibration date and expiry. Provide gauge calibration report.
Test Gauge # XXX 0 – XXX psi Calibrated on XXX Calibration due XXX Please refer to attached gauge calibration document.
![Page 2: PVEng Vessel Engineering Ltd. 120 Randall Drive, Suite B Waterloo, FOntario, Canada N2V 1C6 Tel. 51 9- 80 ax 5 19- 8 0 i nf o@pve g.c m](https://reader037.fdocuments.in/reader037/viewer/2022092619/5aef750d7f8b9ac2468cce57/html5/thumbnails/2.jpg)
Pressure Vessel Engineering Ltd.120 Randall Drive, Suite B
Waterloo, Ontario, Canada
N2V 1C6
Tel. 519-880-9808
Fax 519-880-9810
www.pveng.com
PVEng
Page 2 of 2
This document and any information contained herein are considered confidential and may not be used or disclosed except in accordance with any agreements made with or by PVEng.
Results (ASME VIII-1 UG-101) Indicate hold time, results, add comments if any.
Pressure (psi)
Duration (min)
Comments Result
50 0.5 Initial pressure No leak found
75 0.5 No leak found
100 0.5 No leak found
125 0.5 No leak found
150 0.5 No leak found
175 0.5 No leak found
200 0.5 No leak found
225 10 No leak found
270 10 No leak found
300 7 Leak witnessed after 7 min Leak found
*Test was completed at ambient temperature. Summarize results
A leak was witnessed at 300 psi after 7 minutes holding time.
Local failure was witnessed at the head opposite the spigot side.
Last pressure with no leak witnessed was 260 psi Witnesses Have all parties involved sign and date the report.
This test was conducted in the presence of an authorized inspector on XXX. Completed by ___________________________ XXX XXX (Customers Company) Witnessed by ___________________________ ______________________________ XXX Authorized Inspector National Board Number