pvc roofing panels - Tectubo · Brazilian fire safety code NBR 15575 - Edifícios Habitacionais -...

4
Distrito Industrial Governador Luiz Cavalcante, rua João José Pereira Filho, s/n, Qd. 05, Mód. 11 e 12 s/n, Tabuleiro do Martins | Maceió | Alagoas +55 82 2122.8600 Soluções em PVC @tectubo @tectubo @tectubo FACTORY ADDRESS deserves this protection. Installation guide Your family deserves this protection. pvc roofing panels pvc roofing panels ® Your family A member of

Transcript of pvc roofing panels - Tectubo · Brazilian fire safety code NBR 15575 - Edifícios Habitacionais -...

Distrito Industrial Governador Luiz Cavalcante,rua João José Pereira Filho, s/n, Qd. 05, Mód. 11 e 12 s/n, Tabuleiro do Martins | Maceió | Alagoas

+55 82 2122.8600

Soluções em PVC

@tectubo @tectubo @tectubo

FACTORY ADDRESS

deserves this protection.

Installationguide

Your family deserves this protection.

pvc roofing panels

pvc roofing panels®

Your family

A member of

2.30m 2.63m 3.28m 3.94m 4.59m 5.25m

7 8 10 12 14 16

0.84m 0.84m 0.84m 0.84m 0.84m 0.84m

0.90m 0.90m 0.90m 0.90m 0.90m 0.90m

1.93m2 2.21m2 2.76m2 3.31m2 3.86m2 4.41m2

2.30mm 2.30mm 2.30mm 2.30mm 2.30mm 2.30mm

4 4 5 6 7 8

9 9 12 15 18 21

9.2kg 10.5kg 13.1kg 15.8kg 18.4kg 21kg

2.44m 3m 6m

1.30mm 1.30mm 1.30mm

1.20m 1.20m 1.20m

6 7 14

2.85m2 3.51m2 7.02m2

7.6kg 9.4kg 18.7kg

1.17m 1.17m 1.17m

18 18 36

For Tectubo’s full line of products, visit our website:

The Neotelha Fastening Kit includes rubber rings, waterproof caps andself drilling screws. The screws are optimized for metallic surfaces or woodbeams.

PVC ridge cap

Accessories

Fastening kit

Line of products Tectubo

Colonial roofing sheets are manufactured with high-qualityPVC resin. They're lightweight,easy to use, efficient, andwith excellent finish.

Clay

Ivory

Length

Screws (per sheet)

Weight (per sheet)

Thickness

Support (qty. per sheet)

Assembled Width

Width

Coverage Area

Technical Specifications:

Color: White

Corrugated roofing sheets aremanufactured with high-qualityPVC resin. They're lightweight,easy to use, efficient, andwith excellent finish.

Corrugated Panel

PVC roofing panels

By using Neotelha, your overall construction costs will besignificantly reduced in comparison with other roofing materials.You will also benefit from easier installation, reduced waste,reduced roof structure, among other benefits.

Neotelha is eco-friendly and 100% recyclable. Its manufacturingprocess allows for recycling and reuse of industrial waste.

Neotelha prevents the spread of fire and is compliant with theBrazilian fire safety code NBR 15575 - Edifícios Habitacionais- Desempenho.

Neotelha is resistant to extreme weather changes and remainsstable. Its exceptional structural resistance and load bearingcapacity withstand hail, wind gusts and even small animals.

Neotelha embellishes any building and inhibits the growthof fungus, preventing premature ageing and darkening of theroof.

Economy, Convenience, Beauty and Durability are some of theadvantages of using Neotelha.Additional benefits are highlighted below:

Advantages of the NeotelhaPVC roofing panels:

Neotelha PVC sheets are light and reduce installationtime in comparison with other roofing materials.

Neotelha is resistant to chemical and atmospheric agents suchas industrial emissions, sea sprays, acids, and other corrosivesubstances.

Length

Screws (per sheet)

Weight (per sheet)

Thickness

Support (qty. per sheet)

Assembled Width

Width

Modules

Coverage Area

Technical Specifications:

Colors:

Colonial Panel

Assembled length 800mm

PVC ridge end capAssembled length 800mm

PVC verge capAssembled length 1.20m

660 - 710mm

500 - 600mm

The maximum distance between supporting beams must be:Corrugated: 600mm / Colonial: 710mm

COVERAGE

LINE

Outline of the truss and supporting structurefor Neotelha Corrugated PVC roofing sheets.

Outline of the truss and supporting structurefor Neotelha Colonial PVC roofing sheets.

For better fastening, a joist should be used at the ridge.

Corrugated schematic

Colonial schematic

After securing the metal structure with cement, it is important toensure that the surface is flat and with proper spacing;

The solder must conform to each project and material's specificationsand regulations;

The pieces must be level, without visible damage, and their thicknessmust be greater than 25mm (the thickness of rafters/purlins willdepend on the type of truss design selected);

The wood structure must be the correct dimensions, flat, with novisible damage (such as surface cheeks or splits), and treated withprotective finish;

The supporting beams should be 25x60mm (purlins), 40x60mm(rafters) or 60x120mm (depending on clearance). If metal, useU-shape 30x50mm or 40x75mm;

Metal studs must be treated against rust, corrosion, and with a layerof epoxy enamel. Wood beams can be painted, treated with linseed oil,or other waterproofing products;

The first piece must be 70mm away from the edge. The last piece mustbe 100mm away from the ridge.

The wood structure can be fastened with wood screws or nails.

Any metallic structure must be treated against rust;

The truss (metal or wood) must be treated against corrosion and/orwith preservatives. Metal pieces can be soldered and wood can befastened directly;

The minimum pitch for Neotelha PVC gabled roofs is 20 degrees. The productcan be installed vertically as long as the assembly instructions provided arefollowed. For mono-pitched roofs, the minimum pitch shall be 5 degrees.

Pitch

Metal, concrete and wood structures

T

Support

PPE (Personal protective equipment) including: hard hats, goggles,safety belts, gloves and boots.

Do not climb on the roof if it is wet or humid, as it will be too slippery.

Be aware of the power lines.

Keep the area around the roof clear and free of debris.

Always wear a safety belt and line.

Ensure that equipment and tools are properly secured.

Do not step directly on the PVC sheets.

Be careful not to hurt or squeeze your hands and fingers.

The following equipment is required to install Neotelha: plumb line, powerdrill, drill bits, power saw, ruler, square, wrench and sandpaper, as well asall required work safety gear and procedures.

Tools and protective equipment

Installation & safety

FIRSTSUPPORT

20 DEGREE MINIMUM FOR GABLED ROOFS 5 DEGREE MINIMUM FOR MONO-PITCHED ROOFS

Pitch between 20 and 80 degrees.

20 DEGREE MINIMUM FOR GABLED ROOFS 5 DEGREE MINIMUM FOR MONO-PITCHED ROOFS

Pitch between 20 and 80 degrees.

SECONDSUPPORT RIDGE

SECONDTO LASTSUPPORT LAST

SUPPORT

COVERAGE

LINE

FIRSTSUPPORT

SECONDSUPPORT RIDGE

SECONDTO LASTSUPPORT LAST

SUPPORT

660-710mm

500-600mm

Support

Support

Support

Support

Neotelha/TectuboFastening Kit

Neotelha/TectuboFastening Kit

Distance (mm

)

Distance (mm)

Neotelha/Tectubo Fastening Kit

Support

Neotelha/Tectubo Fastening Kit

Panels should always be fastenedat their highest points. Each panelmust be fastened to at least threeplaces as per the models below.

The minimum overlap betweensheets must be:

Corrugated sheets: 150mmColonial sheets: 100mm

For Corrugated sheets, the maximum distance between supporting pointsshould not exceed 500mm.

For Colonial sheets, the maximum distance between supporting pointsshould not exceed 660mm.

Place sheets from the bottom up. Ensure that the bottom sheets are aligned withthe edge of the roof. Start by fastening the bottom part of the sheet and move upaccording to the numeric pattern in the image that follows:

Corrugated panel

Colonial panel

PVC or galvanized steel rain gutters can be used. Steel rain guttersmust have a minimum thickness of 0.6mm and PVC 1.5mm.The width should be 270mm.

Please check to ensure that the bottom and side edges of the roof arestill aligned after installing three or four new sheets, until completion;

When overlapping sheets, a minimum clearance of at least 100mmmust be kept from the edges. The same distance should be kept whenoverlapping the first and second sheets;

The distance between the sheets and the axis of the ridge must notexceed 100mm. If required, sheets can be cut with a power saw;

Sheets must always overlap at their sides and edges. Excess must be cutaway. Before cutting, ensure the edges and sheets are aligned correctly.

An eave overhang of 58cm is recommended for best finishing.Rafters should be spaced 3m apart.

Ridge caps follow the same patterns and designs of the two sheets.They can be installed with the fastening kit;

During installation, the ridge cap must be aligned to the existingsheets. It is usually fastened in three places.

Ridge end caps must be placed at the ends of the ridge. They shouldoverlap the ridge cap by between 100 and 200mm.

Tectubo provides you with this exclusive finishing cap. It must befastened in at least two places.

Ensure that the side sheets are properly positioned and fastened;

Before installing, ensure that the model and size selected willfit your project.

The first step is to pull string lines to define the position and edges of the roof,ridge, rain gutters and required cuts.

Truss Pull string lines Support beams Rain gutters

Installcentral sheets

Installridge cap

Installridge end caps

Adjust surfaces,connections

and joints

Installvalleys and hips

Installside sheets

Installation workflow

String lines Corrugated Profile

Colonial Profile

Eaves

20° ridge cap

Ridge end cap

Rain gutter installation

Placement of the Neotelha PVC sheets

Placement details

Important: Please follow the installation instructions exactly.

Installation