Pulsar MX from 5kVA up to 20kVA
MX 16U Frame4 & 5 kVA
Pulsar MX RT2 Pulsar MX + ModularEasy
(European model)
8 & 10 kVA15 & 20 kVA
MX 10U FrameComing Oct 2007!
5 & 10 kVA
15/12/12
Pulsar MX at a glance New range : upgrade without upfront cost, 2 major products :
> Pulsar MX : Best-in-class On-Line UPS at 5 kVA
– Best-in-class features– 2 hot-swappable Power and Battery
sub-modules w/o load interruption– Flexible connectivity– Best supervision & management
> Pulsar MX 16U Frame : 15 & 20 kVA Modular Solution– Similar features– Based on 5kVA power & battery sub-modules
> Pulsar MX 10U Frame : 5 & 10 kVA Modular Solution – Coming 9/2007
– Similar features– Based on 5kVA power & battery sub-modules– Parallels up to 10kVA for capacity or redundancy
Designed to meet the requirements of key channels> Distribution> Jobs> OEM / Key Accounts
15/12/12
Pulsar MX RT, Pulsar MX Frame
Tower/Rack10 min
Rack mounting kit included
20 kVA / 18 kW MX Frame
15 kVA + 5 kVA redundant10 kVA + 2 x 5 kVA redundant
15 kVA / 13.5 kWMX Frame
10 kVA + 5 kVA redundant5 kVA + 2 x 5 kVA redundant
Empty MX Frame for P&B s-m hosting / upgrades from 5kVA standalone units
5 kva Power sub-module
Battery sub-module
MX Transformer5000
5 kVA / 4.5 kW
Rack kitMX EXB 1xEXB 45 min
2xEXB 80 min
3xEXB 120 min
Power sub-module
Battery sub-module
JUN
E 06
JULY
07
Rack mounting kit included
15/12/12
Availability : Online double conversion
Business continuity and high quality power :
> Input voltage range : 120 - 280 Volts (single phase input for MX & MX Frame) 250 - 465 Volts (three phase input for MX Frame) without batteries draining
> AC bypass /AC normal separate or common (MX Frame)
> PFC system: THDI < 7%> Input frequency range : 40-70Hz
> High quality output : THDU < 3%
Input
Frequency variation
Voltage fluctuation
Perfect waveform Output
On-line mode
Bypass-mode
Automatic bypass
Filter
Benefits : > 0ms transfer time> Compatible with poor quality grid and
genset> No battery draining
15/12/12
Availability : Pulsar MX
Hot-swappability for :
> Power sub-module (24 lbs)> Battery sub-module (64 lbs)
Seamless maintenance
> Front access for sub-modules hot-swappable maintenance
> Automatic bypass mode when power module is pulled out
� Bypass-mode
� Normal
Benefits : > Maintenance easiness> Without load interruption
15/12/12
Availability : Parallel operation with MX ModularEasy
Start from a single Pulsar MX + ModularEasy
Combine a second Pulsar MX
Achieve parallel operation w/o load interruption : 1UPS + 1 redundant UPS
Pulsar MXPulsar Mx price base
= 100
Pulsar MX
ModularEasy LoadModularEasy = 35
Pulsar Mx price base = 100
Benefits : > No oversized investment at first step> Parallel operation based on standard UPSs> Seamless operation for the secured device
15/12/12
Availability : Pulsar MX Frame 15000 & 20000
Pulsar MX Frame : modular system based on Pulsar MX 5000 Power and Battery sub-modules
> dynamic redundancy from N+1 to N+3:
– « Meta UPS » management– front access hot swappability (power or
battery sub-modules)
– automatic static switch bypass sized at 20kVA for increased availability
– Make-before-break manual general bypass lockable
Benefits :
> Optimum availability
15/12/12
5 kVA Power s-m
Ex : Redundancy mode
Load: 12kVA
3 UPSs + 1 UPS redundant
5 kVA Power s-m
5 kVA Power s-m
5 kVA Power s-m
Pulsar MX Frame20000
Availability : Parallel operation with Pulsar MX Frame
Dynamic redundancy from N+1 to N+3
5 kVA Power s-m
Ex : Power extension mode
Load: 18kVA
4 UPS + 0 UPS redundant
Pulsar MX Frame20000
5 kVA Power s-m
5 kVA Power s-m
5 kVA Power s-m
60%60%60%60%
90% 90% 90% 90%
15/12/12
Availability : Pulsar MX 5000
10min standard at 70 % load = 3U
3U EXB battery module = 2 x Battery sub-modules inside
Automatic battery detection
Up to 2 hours with 3 EXB modules
5 KVA @ 70%/ 100 % 8 / 5 min 95 / 60 min 60 / 40 min 35 / 20 min
15/12/12
Pulsar MX FRAME Battery Extension
Example #1: 20kVA configuration
Pulsar MX Frame 20 kVA 8min
POWER
POWER
POWER
POWER
BATT
BATT
BATT
BATT
Backup time
20 KVA @
70%/ 100 % 8 / 5 mn 35 / 20 mn 60 / 40 mn 95 / 60 mn
DCbus
DCbus
DCbus
DCbus
15/12/12
Pulsar MX FRAME Battery Extension
Example #2: 15kVA configuration
Pulsar MX Frame 15 kVA 8min
POWER
POWER
POWER
BATT
BATT
BATT
DCbus
DCbus
DCbus
Backup time
15 KVA @
70%/ 100 % 8 / 5 mn 35 / 20 mn 60 / 40 mn 95 / 60 mn
15/12/12
Pulsar MX Frame: EXB integration recommendations
Rack
> Do not forget to order – 6 foot Battery extension cables (68528)
– 3 cables for any 15kVA installation– 4 cables for any 20kVA installation
– Rail kit already included
Tower
> For Pulsar MX 15kVA– Caster Kit (casters + floor mount stand + seismic bracket) (87410)– 1x MX / EX RT Battery integration System (86005)– 3x 6 foot battery.cable (68528)
> For Pulsar MX Frame 20 kVA + 12 EXB please order:– Caster Kit (casters + floor mount stand + seismic bracket) (87410)– 1x MX / EX RT Battery integration System (86005)– 1x additional MX / EX RT Battery Integration System (86005) for 12 EXBs– 4x 6 foot battery.cable (68528)
15/12/12
Pulsar MX Frame: EXB integration recommendations
Tower Configurations – 15kVA Installation
1 Extension3x EXBs
3x 6 foot cables1x Batt.Integ.Kit
2 Extension6x EXBs
3x 6 foot cables1x Batt.Integ.Kit
1x Caster Kit
3 Extensions9x EXBs
3x 6 foot cables2x Batt.Integ.Kit
15/12/12
Pulsar MX Frame: EXB integration recommendations
Tower Configurations – 20kVA Installation
1 Extension4x EXBs
4x 6 foot cables1x Batt.Integ.Kit
2 Extensions8x EXBs
4x 6 foot cables1x Batt.Integ.Kit
1x Caster Kit
3 Extensions12x EXBs
4x 6 foot cables2x Batt.Integ.Kit
1x Caster Kit
15/12/12
Flexibility: Pulsar MX Frame 2 models : 15 & 20 kVA
1 versatile model for stand-alone & rack enclosures (31.5”+ depth)
> Pulsar MX Frame 15 / 20000 = 16U for rack (D = 29.1”), 31.3” high for tower (with optional caster kit)
> Delivered with: 8 min runtime + rail kit> Optional Caster kit and Network Management CardMX Frame stand alone Pulsar MX Frame rack integration
Benefits :
> Integration in high density rack cabinets> Integration in technical rooms
15/12/12
Comprehensive and multi-protocol supervision
Local electrical supervision and shutdown
UPS control
DB9 5 voltage free output contacts
2 A 48 V DC
MC Contacts/serial card
Local soft supervision and point to point shutdown
Personal Solution-Pac
DB9 Serial port/USB
Remote supervision via NMS or EPM, MGE superviser
Web supervision
HP OpenViewIBM NetviewCA UnicenterHP Insight Manager
NMC Card
Building Management System
NMC modBus/ jbus (12/06)
15/12/12
TCO : Power extension without upfront cost
Seamless migration from 5 up to 20 kVA at optimized cost
Pulsar MX 5 kVA 4.5 kW
100
MX Frame 15 kVA 13.5 kW
MX Frame 20 kVA 18 kW
315 370
MX 10U Frame 10kVA9 kW
235
15/12/12
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
Pulsar MX Migration5kVA Standalone to 20kVA Frame
15/12/12
Pulsar MX 5000 Transformer
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
Pulsar MX SystemsComplete Systems/Kits Available
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
BATTERYSub-module
POWERSub-module
Pulsar MX RT 5kVA HV
Part# 87050
Includes: (1) Pulsar MX RT (3U) Chassis with Rail Kit (1) Power Sub-module (1) Battery Sub-module Fully assembled in one box
Pulsar MX RT 5kVA LV
Part# 87150
Includes: (1) Pulsar MX RT (3U) Chassis with Rail Kit (1) Power Sub-module (1) Battery Sub-module Fully assembled in one box
(1) MX 5000 Transformer (2U)
Pulsar MX 15kVA HV
Part# 87415
Includes: (1) Pulsar MX (16U) Chassis with Rail Kit
(3) Power Sub-modules
(3) Battery Sub-modules
Each component in a separate box
Pulsar MX 20kVA HV
Part# 87420
Includes: (1) Pulsar MX (16U) Chassis with Rail Kit
(4) Power Sub-modules
(4) Battery Sub-modules
Each component in a separate box
Pulsar MX RT Pulsar MX 16U Frame
5kVA HV (3U) 5kVA LV (5U) 15kVA HV 20kVA HV
Pulsar MX Frame vs competition
15/12/12
Pulsar MX Frame vs APC
CommentsPulsar MX Frame Symmetra LX MX Frame vs LX
Tower / Rack 16U 19U Both models 800 mmHxWxD 653x444.5x735 mm 838x472x688 mm depth compatible
Interface LCD + LEDs + Mimic LCD + LEDs Multilingual LCD for both
I/O connection 8 IEC10A+4 IEC16A+in/output HW 8 IEC10A+10 IEC16A+in/ouput HW 8 IEC cords supplied + IEC lock system No
Runtime 8 min → 90 min 7.5 min → 4 h 35
Loadshedding No
Options UPS control MBP, Transfo, PDU
Maintenance Front battery & power sub-modules Front battery & power sub-modules Battery test Monthly by default, daily, weekly Weekly by default, 14 days
U input range at 70% load 115-275 V 155-276 V
F input range 40-70 Hz 45-65 Hz
Redundancy 15 kVA or 10+5 KVA redundant 12 kVA or 8+4 kVA redundant20 kVA or 15+5kVA redundant 16 kVA or 12+4 kVA redundant
VA / Watt ratio 0.9 0.7 More Watt for MGE
Efficiency (normal / ECO mode) 92% / 97% 90% / No ECO mode
15-20 kVA 12-16 kVA (4 kVA //)
Automatic recognition
Combo 1/1 & 3/1
1 UPS redundant 1 battery & 1 power module 1 battery & 1 power module
15/12/12
Pulsar MX Frame vs Chloride
CommentsPulsar MX Frame Linear Plus MX Frame vs Linear Plus
Format Tower / Rack 16U TowerHxWxD 653x444.5x735 mm 800x(3x300)x675 mmInterface LCD + LEDs + Mimic LCD + LEDs LCD only in English for
Chloride I/O connection 8 IEC10A+4 IEC16A+in/output HW in/output HW
8 IEC cords supplied + IEC lock system No
Runtime 8 min → 90 min 10 min → 1 h 00
Loadshedding No Options UPS control No
Maintenance Front battery & power sub-modules No Chloride: MBP in standard
Battery test Monthly by default, daily, weekly From 7 to 180 days Accurate adjustment butnot daily
U input range at 70% load 115-275 V 176-276 VF input range 40-70 Hz 47.5-52.5 Hz
Redundancy 15 kVA or 10+5 KVA redundant 18 kVA or 12+6 kVA redundant20 kVA or 15+5kVA redundant -
VA / Watt ratio 0.9 0.7 More Watt for MGEOperation & installation cost THDI<7% THDI<5%(1/1) ; THDI<25% (3/1)Efficiency (normal / ECO mode) 92% / 97% 91% / No ECO modeCommunication 2 slots + free contacts 1 slot + free contacts
USB & RS232 compatible RS232 compatible
15-20 kVA 12-18 kVA (6 kVA //)
Automatic recognition No Optimal use of EXBcabinets in any situation
Combo 1/1 & 3/1 No Combo for Linear+ 10 kVA
1 UPS redundant 1 battery & 1 power module 1 battery & 1 power module
15/12/12
Pulsar MX Frame vs Socomec
CommentsPulsar MX Frame Modulys MX Frame vs Modulys
15-20 kVA 18-24 kVA (6 kVA //)HxWxD 653 (16U) x444.5x735 mm 1824 (41U) x550x625 mm
Interface LCD + LEDs + Mimic LCD + LEDs Multilingual LCD for both
I/O connection 8 IEC10A + 4 IEC16A + in/output HW 1 IEC10A + in/output HW 8 IEC cords supplied + IEC lock system No
Runtime 8 min → 90 min 8 min → 35 minLoadsheddingOptions UPS control Transfo, UPS control
Maintenance Front battery & power sub-modules Front battery & power modules
Battery test Monthly by default, daily, weekly ?U input range at 70% load 115-275 V 161-276 VF input range 40-70 Hz 45-55 Hz
Redundancy 15 kVA or 10+5 KVA redundant 18 kVA or 12+6 kVA redundant Socomec keeps the same20 kVA or 15+5 kVA redundant 24 kVA or 18+6 kVA redundant UPS in a dedicated frame
VA / Watt ratio 0.9 0.7
Operation & installation cost THDI<7% THDI<6%(1/1)
Efficiency (normal / ECO mode) 92% / 97% 89% / 97%Communication 2 slots + free contacts 2 slots, free contacts
USB & RS232 compatible RS232 compatible
Automatic recognition ? Optimal use of EXBcabinets in any situation
Tower / Rack
Combo 1/1 & 3/1
15/12/12
Pulsar MX Frame vs Liebert
CommentsPulsar MX Frame Nfinity MX Frame vs Nfinity
15-20 kVA 12-16-20 kVA (4 kVA //)
Interface LCD + LEDs + Mimic LCD + LEDs + Mimic Multilingual for both
I/O connection 8 IEC10A + 4 IEC16A + in/output HW in/output HW 8 IEC cords supplied + IEC lock system No
Runtime 8 min → 90 min 7 min → 1 h 45 min
Loadshedding No
Options UPS control Transfo
Maintenance Front battery & power sub-modules Front battery & power sub-modules
Battery test Monthly by default, daily, weekly 1, 2, 3, 4, 5 or 6 weeks
U input range at 70% load 115-275 V 147-273 V
F input range 40-70 Hz 40-70 Hz
Redundancy 15 kVA or 10+5 KVA redundant 16 kVA or 12+4 kVA redundant20 kVA or 15+5 kVA redundant 20 kVA or 16+4 kVA redundant
VA / Watt ratio 0.9 0.7Operation & installation cost THDI<7% THDI<4% (1/1), THDI<26% (3/1) PFC system for MGEEfficiency (normal / ECO mode) 92% / 97% 91% / No ECO mode
Communication 2 slots + free contacts 4 slots, free contactsUSB & RS232 compatible RS232 compatible
Automatic recognition No Optimal use of EXBcabinets in any situation
Combo 1/1 & 3/1 No16 kVA 1/1 or 3/1 ; 20 kVA only in 3/1
Format Tower / Rack 16U TowerHxWxD 653x444.5x735 mm 1372x508x711 mm