PULEO PE725 Series Alarm Annunciator

4
PULEO PE 725 SERIES Programmable Alarm Annunciator For reliable annunciation using the “no master module” concept Complete Alarm System Everything is contained within the standard 725 Annunciator to provide a complete alarm monitoring system. This includes all pushbuttons and a local audible. Rack Mounting (OPTION) The Annunciators can be supplied pre-mounted in standard 19” aluminum mounting plates. A maximum of 7 cells will fit across a 19” front plate. Legends The legends can be supplied as requested or alternatively film legend generation software is available to allow customers the convenience of making their own film legends using a standard laser printer. Alarm Contacts All inputs are opto-coupled, (isolated from the supply on request). The standard unit is suitable for volt-free contacts or 24Vdc voltage inputs. Optional inputs voltages include 48V, 125V, 110V, 250 V, AC or DC. Power Supplies The supply required to power the annunciator in nominally 24 Vdc. Puleo can supply suitable power supplies or DC/DC converters if converting from other AC or DC voltages. All sizes from 1 to 252 points “No master module” ASIC technology so there is no single point of failure Only 145 mm (5.71”) installed depth Three different window sizes Ultra-bright LED illumination User programmable from the front for alarm sequences and function Five relay outputs as standard Individual repeat relays for all points Modbus Available as an option PULEO SL-2 1/17/12 Page 1

Transcript of PULEO PE725 Series Alarm Annunciator

  • 15 PULEO

    PE 725 SERIES

    Programmable Alarm AnnunciatorFor reliable annunciation using the no master module concept

    Complete Alarm SystemEverything is contained within the standard 725 Annunciator to provide a complete alarm monitoring system. This includes all pushbuttons and a local audible.

    Rack Mounting (OPTION)The Annunciators can be supplied pre-mounted in standard 19 aluminum mounting plates. A maximum of 7 cells will fit across a 19 front plate.

    LegendsThe legends can be supplied as requested or alternatively film legend generation software is available to allow customers the convenience of making their own film legends using a standard laser printer.

    Alarm ContactsAll inputs are opto-coupled, (isolated from the supply on request). The standard unit is suitable for volt-free contacts or 24Vdc voltage inputs. Optional inputs voltages include 48V, 125V, 110V, 250 V, AC or DC.

    Power SuppliesThe supply required to power the annunciator in nominally 24 Vdc. Puleo can supply suitable power supplies or DC/DC converters if converting from other AC or DC voltages.

    All sizes from 1 to 252 points

    NomastermoduleASICtechnologyso there is no single point of failure

    Only145mm(5.71)installeddepth

    Three different window sizes

    Ultra-bright LED illumination

    User programmable from the front for alarm sequences and function

    Five relay outputs as standard

    Individual repeat relays for all points

    Modbus Available as an option

    PULEO

    SL-2 1/17/12 Page 1

  • 16PULEO

    PE 725 SERIES

    System Configuration

    MODBUS Option

    For RS485 serial communications with remote equipment, the PE 725 can be supplied with the MODBUS protocol .

    This allows the unit to transmit / receive alarm information between PE 725s or from PLCs or SCADA systems .

    The Series 725 Annunciator is a modular design allowing a customer to quickly design an alarm system to suit their exactrequirements for both window size and number of windows. The system is built up of multiple cells, each cell has dimensionsof 60 x 60mm (2.36 x 2.36) and can be configured as a single large window (60 x 60mm) (2.36 x 2.36), two mediumwindows (60 x 30mm) (2.36 x 1.18) or four small windows (30 x 30mm) (1.18 x 1.18).

    The overall limits for the annunciator are as follows:Large window (60 x 60mm) (2.36 x 2.36) 99 windowsMedium window (60 x 30mm) (2.36 x 1.18) 198 windowsSmall window (30 x 30mm) (1.18 x 1.18) 256 windowsThese can be configured into almost any shape and size as long as the overall width or height is no greater than 30 cells.

    The numbering scheme adopted is shown below. To avoid any confusion when providing text or configuration detailsplease refer to these numbering schemes.

    60mm (2.36)

    60mm(2.36)

    60mm (2.36)

    30mm(1.18)

    30mm(1.18)

    Window Size & Layout

    Large Medium Small

    30mm(1.18)

    30mm(1.18)

    30mm(1.18)

    30mm(1.18)

    Plug-in terminals

    Rear View/ Removable Customer TerminalsLarge Medium Small

    1

    2

    3

    4

    5

    7

    8

    9

    10

    13

    14

    6

    11

    12

    15

    1

    3

    5

    7

    9

    11

    2

    4

    6

    8

    10

    12

    13

    15

    17

    19

    14

    16

    18

    20

    1 4

    52

    3

    The Series 725 Annunciator is a modular design allowing a customer to quickly design an alarm system to suit their exactrequirements for both window size and number of windows. The system is built up of multiple cells, each cell has dimensionsof 60 x 60mm (2.36 x 2.36) and can be configured as a single large window (60 x 60mm) (2.36 x 2.36), two mediumwindows (60 x 30mm) (2.36 x 1.18) or four small windows (30 x 30mm) (1.18 x 1.18).

    The overall limits for the annunciator are as follows:Large window (60 x 60mm) (2.36 x 2.36) 99 windowsMedium window (60 x 30mm) (2.36 x 1.18) 198 windowsSmall window (30 x 30mm) (1.18 x 1.18) 256 windowsThese can be configured into almost any shape and size as long as the overall width or height is no greater than 30 cells.

    The numbering scheme adopted is shown below. To avoid any confusion when providing text or configuration detailsplease refer to these numbering schemes.

    60mm (2.36)

    60mm(2.36)

    60mm (2.36)

    30mm(1.18)

    30mm(1.18)

    Window Size & Layout

    Large Medium Small

    30mm(1.18)

    30mm(1.18)

    30mm(1.18)

    30mm(1.18)

    Plug-in terminals

    Rear View/ Removable Customer TerminalsLarge Medium Small

    1

    2

    3

    4

    5

    7

    8

    9

    10

    13

    14

    6

    11

    12

    15

    1

    3

    5

    7

    9

    11

    2

    4

    6

    8

    10

    12

    13

    15

    17

    19

    14

    16

    18

    20

    1 4

    52

    3

    The Series 725 Annunciator is a modular design allowing a customer to quickly design an alarm system to suit their exactrequirements for both window size and number of windows. The system is built up of multiple cells, each cell has dimensionsof 60 x 60mm (2.36 x 2.36) and can be configured as a single large window (60 x 60mm) (2.36 x 2.36), two mediumwindows (60 x 30mm) (2.36 x 1.18) or four small windows (30 x 30mm) (1.18 x 1.18).

    The overall limits for the annunciator are as follows:Large window (60 x 60mm) (2.36 x 2.36) 99 windowsMedium window (60 x 30mm) (2.36 x 1.18) 198 windowsSmall window (30 x 30mm) (1.18 x 1.18) 256 windowsThese can be configured into almost any shape and size as long as the overall width or height is no greater than 30 cells.

    The numbering scheme adopted is shown below. To avoid any confusion when providing text or configuration detailsplease refer to these numbering schemes.

    60mm (2.36)

    60mm(2.36)

    60mm (2.36)

    30mm(1.18)

    30mm(1.18)

    Window Size & Layout

    Large Medium Small

    30mm(1.18)

    30mm(1.18)

    30mm(1.18)

    30mm(1.18)

    Plug-in terminals

    Rear View/ Removable Customer TerminalsLarge Medium Small

    1

    2

    3

    4

    5

    7

    8

    9

    10

    13

    14

    6

    11

    12

    15

    1

    3

    5

    7

    9

    11

    2

    4

    6

    8

    10

    12

    13

    15

    17

    19

    14

    16

    18

    20

    1 4

    52

    3

    252

    SL-2 1/17/12 Page 2

  • 17 PULEO

    PE 725 SELECTION GUIDE

    PE 725 SERIES - Numbering System:

    PE725 M - 5W - 5H - 6T - 48A SL R FC24 C

    ModelSeries

    Window SizeS = SmallM = MediumL = LargeI = Intermix

    # of CellsW = WideH = High

    PushButton *Module (TAR)6T = StandardNT = External

    # ofAlarmPoints

    LED Display Standard

    RepeatRelays

    Field ContactAC/DC Voltage24 = 9 to 33V 48 = 19 to 70V 125 = 72 to 135V 250 = 141 to 270V

    OptionBlank = NoneC = Modbus RS485

    LAR GE Wi ndows 2.36"W x 2.36" H (60 x 6 0mm ) 1 Window (8 LEDs) Per Cell

    Cells W ideHigh 1 2 3 4 5 6 7 8 9 10

    1 0 1 2 3 4 5 6 7 8 92 1 3 5 7 9 11 13 15 17 193 2 5 8 11 14 17 20 23 26 294 3 7 11 15 19 23 27 31 35 395 4 9 14 19 24 29 34 39 44 496 5 11 17 23 29 35 41 47 53 597 6 13 20 27 34 41 45 55 52 698 7 15 23 31 39 47 55 63 71 799 8 17 26 35 44 53 62 71 80 89

    10 9 19 29 39 49 59 69 79 89 99

    ME DIU M Wi ndows 2.36"W x 1.18" H (60 x 3 0mm ) 2 Windows (4 LEDs) Per Cell

    Cells W ideHigh 1 2 3 4 5 6 7 8 9 10

    1 0 2 4 6 8 10 12 14 16 182 2 6 10 14 18 22 26 30 34 383 4 10 16 22 28 34 40 46 52 584 6 14 22 30 38 46 54 62 70 785 8 18 28 38 48 58 68 78 88 986 10 22 34 46 58 70 82 94 106 1187 12 26 40 54 68 82 96 110 124 1388 14 30 46 62 78 94 110 126 142 1589 16 34 52 70 88 106 124 142 160 178

    10 18 38 58 78 98 118 138 158 178 198

    SM ALL Wi ndows 1.18"W x 1.18" H (30 x 3 0mm ) 4 Windows (2 LEDs) Per Cell

    Cells W ideHigh 1 2 3 4 5 6 7 8 9 10

    1 0 4 8 12 16 20 24 28 32 362 4 12 20 28 36 44 52 60 68 763 8 20 32 44 56 68 80 92 104 1164 12 28 44 60 76 92 108 124 140 1565 16 36 56 76 96 116 136 156 176 1966 20 44 68 92 116 140 164 188 212 2367 24 52 80 108 136 164 192 220 248 8 28 60 92 124 156 188 220 252 9 32 68 104 140 176 212 248

    10 36 76 116 156 196 236

    Dimensions - Overall / CutoutAll units ar e 5.71" D eep

    (1m m = .0394 Inches)No.of

    CellsOverall

    Inches ( mm)Cutout

    Inches ( mm)

    1 3.31 (84) 2.92 (74)2 5.67 (144) 5.28 (134)3 8.04 (204) 7.64 (194)4 10.40 (264) 10.01 (254)5 12.77 (324) 12.37 (314)6 15.13 (384) 14.74 (374)7 17.49 (444) 17.10 (434)8 19.86 (504) 19.46 (494)9 22.22 (564) 21.83 (554)

    10 24.59 (624) 24.19 (614)11 26.95 (684) 26.56 (674)12 29.31 (744) 28.92 (734)

    Window Calculator (Yellow Shading 19 Rack Mountable)

    Colored Lenses Available - Red, Green, Yellow, BlueSpecify Color & Window # when ordering.

    Dimensions - Overall / Cutout

    *If NT TAR,add 1 Alarm Point.

    *If NT TAR,add 2 Alarm Point.

    *If NT TAR,add 4 Alarm Point.

    If Modbus, delete2 Alarm Points

    SL-2 1/17/12 Page 3

  • 18PULEO

    PE 725 SELECTION GUIDE

    PE725-PLATE-19-5W-5H48 Points, Medium Windows shown

    PE 725 Power Supplies 24Vdc OutputSelect PS Model based on Input Voltage and Annunciators Total Current requirements as follows;

    Model No. Input Amps48 Vdc Power InputPE 014-074 36 72Vdc 4.2APE 014-077 36 72Vdc 6.3A

    125 Vdc Power InputPE 014-075 72 144Vdc 4.2 APE 014-076 72 144Vdc 6.3 APE 014-081 72 144Vdc 8.4 A

    110/220 Vac Power InputPE 014-078 100 264 Vac 3.2 APE 014-089 100 264 Vac 5 A

    Total Current = TAR Current + Alarm Point Current x Number of Alarms

    Where TAR Current = 100 ma and Alarm Point Current = 55 ma

    Example: 48 Point Annunciator, 125 Vdc

    TC = .100 + (.055) x 48 TC = 2.74 Amps

    Choose PE 014-075 Power Supply

    Pe 725 19 Rack Mount Plates(Power Supply mounts on Din Rail under Annunciator on Plate)

    Numbering System:

    PE725 - PLATE - 19 - 5W - 5H

    # of CellsW = WideH = High

    CellHeight

    HRU #

    HeightInches

    (1RU = 1.75)1 6 10 .502 8 14 .003 9 15 .754 10 17 .505 12 21 .006 14 24 .507 15 26 .258 17 29 .759 18 31 .5010 20 35 .00

    Note: To fit 19 Rack, Annunciator cannot be more than 7W

    SL-2 1/17/12 Page 4