PTTEP1

1
Flash No. : 001/12 Location : UT1-7/D7 Well (PTTEP1) PTTEP1 Decrease Production Cost by Adjusting Counter Balance Weight Date : January 30, 2012 Introduction/ Opportunity : PTTEP1 team has found the Sucker Rod Load at Share By : Ubol J., Wattana Re., Sanya M., Anucha Ja. and Arnon K. UT1-7/D7 well was too high with a strange noise at Gear Reducer. Why improving “Reliability or Efficiency”? : By reducing the Sucker Rod Load, we can mitigate production cost as we could reduce the load of electrical motor Also the strange noise at Gear Reducer could motor. Also, the strange noise at Gear Reducer could cause major damage to equipment. SOLUTION with COST/ BENEFIT : Adjust Counter Balance Weight by 40 centimeters to reduce load in Up Stroke cycle. Benefit: Picture Benefit: • Reduce load of motor causes reducing electrical power consumption. • Eliminate strange noise in Gear Reducer causes prolong life time of Gear Reducer. • Eliminate noisy environment around community and increase trust from villager. Picture RESULTS AND VALUE : The electrical consumption is reduced as follow; Before: Up Stroke cycle consume electrical current of 40 A and Down Stroke cycle consume 35 A. After: Up Stroke cycle consume electrical current of 25 A and Down Stroke cycle consume 25 A. Picture

description

PTTEP1

Transcript of PTTEP1

Page 1: PTTEP1

Flash No. : 001/12 Location : UT1-7/D7 Well (PTTEP1)PTTEP1

Decrease Production Cost by Adjusting Counter Balance Weight

Date : January 30, 2012

Introduction/ Opportunity :

PTTEP1 team has found the Sucker Rod Load at

( )Share By : Ubol J., Wattana Re., Sanya M., Anucha Ja. and Arnon K.

UT1-7/D7 well was too high with a strange noise at Gear Reducer.

Why improving “Reliability or Efficiency”? :By reducing the Sucker Rod Load, we can mitigate production cost as we could reduce the load of electrical motor Also the strange noise at Gear Reducer couldmotor. Also, the strange noise at Gear Reducer could cause major damage to equipment.

SOLUTION with COST/ BENEFIT :

Adjust Counter Balance Weight by 40 centimeters to reduce load in Up Stroke cycle.

Benefit:

Picture

Benefit:• Reduce load of motor causes reducing electrical power consumption.

• Eliminate strange noise in Gear Reducer causes prolong life time of Gear Reducer.

• Eliminate noisy environment around community and increase trust from villager. Picture

RESULTS AND VALUE :

The electrical consumption is reduced as follow;

Before: Up Stroke cycle consume electrical current of 40 A and Down Stroke cycle consume 35 A.

After:Up Stroke cycle consume electrical current of 25 A and Down Stroke cycle consume 25 A.

Picture