Data Sheet PTC-6 ASME PTC-6 ASME Flow Nozzle Precision Flow Measurement for Steam Turbine Acceptance Tests PTC-6 ASME Flow Nozzle Features P rimary Flow Signal, Inc. is a leader in the design and manufacture of Venturi differential flow meters. Field-proven in hundreds of thousands of installations worldwide, differential metering ensures the most accurate and reliable metering available anywhere. Through innovation, coupled with peerless engineering and technical expertise, PFS delivers customers versatile, ultra-long lasting liquid and gas metering solutions for a variety of applications and industries. The PFS PTC-6 ASME flow nozzle provides the high precision needed for the testing of steam turbines under ASME PTC-6 2004 Performance Test Code. The PTC-6 ASME integrates flow conditioners for added accuracy, and diffuser cones to reduce downstream pressure loss, and also provides flanged-end PTC6- PTFFR and weld-in PTC6-PTWWR style nozzles. Line size: available from 4" to 24" Cones: available in PTC6-PTFFR (flanged-end) and PTC6-PTWWR (weld-in) Engineered to PTC-6 recommended standards: 35 hole perforated plate 19 (standard) to 61 tube bundle Diffuser Cone: mitigates any pressure loss by as much as 70% ASME design standards: ASME PTC-6 2004 ASME PTC 19.5 2004 ASME Research Committee Report on Fluid Meters - 6th. Edition ASME fabrication standards: ASME Section I ASME B31.I - Power piping ASME B31.3 - Process piping End connections: both the flanged- end PTC6-PTFFR and weld-in PTC-PTWWR are equipped with four (4) integrally machined throat pressure taps, and are precision- machined and polished for a cylindrical, hydraulically smooth surface.

description

asme code

Transcript of Ptc 6 Asme Flow Nozzle

  • Data Sheet

    PTC-6 ASME

    PTC-6 ASMEFlow NozzlePrecision Flow Measurement forSteam Turbine Acceptance Tests

    PTC-6 ASME Flow Nozzle Features

    Primary Flow Signal, Inc. is a leader inthe design and manufacture of Venturidifferential flow meters. Field-proven inhundreds of thousands of installations worldwide,differential metering ensures the most accurateand reliable metering available anywhere. Throughinnovation, coupled with peerless engineering andtechnical expertise, PFS delivers customers versatile,ultra-long lasting liquid and gas metering solutionsfor a variety of applications and industries.

    The PFS PTC-6 ASME flow nozzle provides the highprecision needed for the testing of steam turbinesunder ASME PTC-6 2004 Performance Test Code.The PTC-6 ASME integrates flow conditioners for addedaccuracy, and diffuser cones to reduce downstreampressure loss, and also provides flanged-end PTC6-PTFFR and weld-in PTC6-PTWWR style nozzles.

    LLiinnee ssiizzee: available from 4" to 24"

    CCoonneess: available in PTC6-PTFFR (flanged-end) and PTC6-PTWWR (weld-in)

    EEnnggiinneeeerreedd ttoo PPTTCC--66 rreeccoommmmeennddeedd ssttaannddaarrddss:35 hole perforated plate

    19 (standard) to 61 tube bundle

    DDiiffffuusseerr CCoonnee: mitigates any pressure loss by as much as 70%

    AASSMMEE ddeessiiggnn ssttaannddaarrddss:ASME PTC-6 2004

    ASME PTC 19.5 2004

    ASME Research Committee Report on Fluid Meters - 6th. Edition

    AASSMMEE ffaabbrriiccaattiioonn ssttaannddaarrddss:ASME Section I

    ASME B31.I - Power piping

    ASME B31.3 - Process piping

    EEnndd ccoonnnneeccttiioonnss: both the flanged-end PTC6-PTFFR and weld-in PTC-PTWWR are equipped with four (4) integrally machined throat pressure taps, and are precision-machined and polished for a cylindrical, hydraulically smoothsurface.

  • Primary Flow Signal, Inc. products and operations are certified to industry standards for safety and performance. Visit our web site for details.

    Copyright 2012-2016 Primary Flow Signal, Inc. - All rights reserved. Information contained herein is subject to change at any time without prior notice.

    PFS PTC-6 DS 2012 Rev 0

    All PFS products are proudly made in the U.S.A.

    PTC-6-PTFFR: Flanged-end StyleIdeal for condensate return flow where line pressures are low to moderate

    Data Sheet

    PTC-6 ASME

    DIFFUSER CONE

    NAMEPLATEBORE

    LOW PRESSURE TAPSD

    HIGH PRESSURE TAPS

    FLOW CONDITIONER

    FLOW FLOW

    10D20D

    4D HONED2D-4D

    Headquarters800 Wellington Avenue | Cranston, RI 02910 USATel: +1-401-461-6366 | Toll Free: +1-877-737-3569Fax: +1-401-461-4450

    www.primaryflowsignal.com

    Support Services

    In addition to a wide range of differential producing Venturi flow meters, orifice plates, WedgeType flow meters, and open channel flow elements, PFS providescomprehensive, specialized services for new and existingflow meters, including rehabilitation, hydraulic analysis,and full engineering support.

    Certifications

    ISO 9001, ASME S, U, R; European PED Module H; and other internationally recognized certifications, such as GOST, IBR, and CRN.

    Contact a Field Application Engineer for assistance.

    D

    DIFFUSER CONE

    NAMEPLATEBORE

    LOW PRESSURE TAPSHIGH PRESSURE TAPS

    FLOW CONDITIONER

    10D20D

    4D HONED2D-4D

    FLOW FLOW

    INSPECTION PORT

    AApppplliiccaattiioonn: clamped between two mating flanges

    CCoonnssttrruuccttiioonn: this assembly allows for easy removal and inspection of the nozzle, pressure taps, and piping during performance testing

    NNoozzzzllee: can be furnished with the diffuser cone integral to the flow nozzle or as an attachment

    EEnndd ccoonnnneeccttiioonnss: flanges may be flat faced, ring typejoint, large groove, or tongue-and-grooved

    MMaatteerriiaall: carbon steel process piping, 304 stainlesssteel flow nozzle/flow conditioner, other material combinations and grades available

    AApppplliiccaattiioonn: permanently welded in place between the upstream and downstream pipe sections

    IInnssppeeccttiioonn: standard ports to allow for code-recommended nozzle inspection

    PTC6-PTWWR: Weld-in StyleIdeal for the measurement of final feed water flow where line pressures are high