PSR MSSR Antenna/Engine Generator/Citel · -SIU-DVG LAN Hub-RCPs Tower/TRACON-DVGs-SMC...
Transcript of PSR MSSR Antenna/Engine Generator/Citel · -SIU-DVG LAN Hub-RCPs Tower/TRACON-DVGs-SMC...
-Synchronizer U1/2A9A14-Local Oscillator U1/2A5-Up Converter U1/2A6-NTIA Filter U1/2A12-RF Driver Modules U3A5/10-RF Amplifier Modules U3A1/2/3/4/6/7/8/9
COVER PSR/MSSR/ANTENNA/EG/CITEL/FUSES
PSR TransmitterSheet 1
PSR Microwave AsssemblyAntennaSheet 2
PSR Receiver SDP
Sheet 3
SBCs/SCDIsFiber Option
Sheet 4A
Remote SiteSheet 5
PSR FMACSheet 6
PSR TCMMSheet 7
MSSR ReceiverSheet 9
MSSR TransmitterSheet 8
-Bi Directional Couplers U6DC1/2-Circulator U6HY3-RF Detectors U6A2/3/4- Waveguide Switch U6S1-Coaxial Switches U6S2/3-Waveguide TR Tube U6Z1/2-Coaxial Limitters U6Z3/4/5/6-Compressor Dehydrator U18-Rotary Joint U35A6-Wx Hi/Lo Switch-HB/LB Polarizer
PSR MSSR Antenna/Engine Generator/Citel
-RF Assembly U1/2A1-Stability Monitor U1/2A2-Downconverters U1/2A3/4-Beam Azimuth STC U1/2A9A13/21-Pulse Compressor U1/2A9A11/19-LOAPs U1/2A9A8/9/10/18
-SBCs 1, 2, and 3 U1/2A9A1/3/4-Ethernet Transceivers U1/2A14/15-Channel UPS U1/2A10-8 Port LAN Repeater U7A6/9A1-SCDIs U7A3/4-4 Port LAN Switch W/FO Transceiver U7A6/9A2-MPS 800 Server U7A7/10-Maintenance RCP
-24 Port Flex Switch-OMT U52-SDT-SIU-DVG LAN Hub-RCPs Tower/TRACON-DVGs-SMC (CENRAP)
-FMAC U7A1/2- Pedestal Junction Box-FMAC Junction Box U31A20-I/O Panel U7A14-FMAC Interface U7A15
-Transmitter Control U4A2A2/5-Transmitter Status U4A2A3/6-Transmitter RF Monitor U4A2A4/7
-Mode Generator-Site Services Interface-Control & BIT-Driver Module-Low Duty Cycle Power Amplifier-Fan And Power Supply Unit-Transmitter Interface-RF Changeover Switch (RFCO)-Plot Extractor Processor
-Receiver Interface Assembly-Sum Difference Control Receivers-Video and Timing-Reply Decoder-Site Services Interface-Plot Extractor Processor-Daughter Card-Monitor Panel
Sheet Link Indicator Sheet IndicatorTo/From Sheet Number
Find NumberUnique Number to assist in locating link
Same Sheet Jump
SBCs/SCDIsTelco Option
Sheet 4B
-SBCs 1, 2, and 3 U1/2A9A1/3/4-Ethernet Transceivers U1/2A14/15-Channel UPS U1/2A10-8 Port LAN Repeater U7A6/9A1-SCDIs U7A3/4-8/24 Port LAN Switch U7A6/9A2-MPS 800 Server U7A7/10-OMT Routers-Radar Lan A/B Routers-Maintenance RCP
Antenna Pedestal Status Sheet 10
-Pedestal Low Temp-Sump Oil Level-Clutch Status-Gearbox A/B Oil Level-Gearbox A/B Oil Over Temp-Drive Motor A/B Over Temp
Antenna HeatersSheet 11
-Sump Heater On/Off-Sump Heaters-Gearbox A/B Heaters
Antenna Drive Control
Sheet 12
-Motor Controller A/B-Pedestal Interface U16-Pedestal Local Control Panel
Antenna Interlock Chain
Sheet 13
-Hatch-Handcrank-Safety Switch-Stow Pin
Antenna Polarizer OB LightsSheet 14
-Linear Control-Linear status-Circular Control-Circular Status-Obstruction Lights
Antenna Az Enc & Wx Beam Sw
Sheet 15
-X Encoder Data Path-Y Encoder Data Path-Wx Beam Switch Control & Stat-Encoder & BEAM Sw PS
Engine GeneratorSheet 16
-Citel Base 1 EG Shelter-Citel Base 2 Radar Shelter-EG Status & Controls
Citel Base 3,4,5,6Sheet 17
-Citel Base 3 ECU (Air Conditioner)-Citel Base 4 Radar Shelter-Citel Base 5 Pedestal Room-Citel Base 6 Telco
Fuse DrawingSheet 18
-FMAC Fuse Panel
ASDP U1A19Status:REX PSSDP PSUPSOver TempCPI ActiveFrame CountCPI Fault
TestSignals to RIC
Front Panel
DWG
Local Oscillator U1A5
Freq Sel
MultDiv
COHO
124.2816
E C B A
3224.32 – 3424.32A
Hi Filt
2:1Comb
497.1331.07
5.182.59
F1
F2
F4
F3
J23.88Mhz
J327.19Mhz
J1 +5dBmRF Mon
Up Converter U1A6
524.32Mhz
15db 14db 37dbWaveformSelect
Frame In/O
ut, CP
I In/Out M
aintains Clutter M
ap in Standby C
hannel
1:2Div
F3/F4
F1/F2
Lo Filt
To Stability Monitor A2
RF DriverU3A5 Chan A
2.7 – 2.9 GHz2.8us SP
89us LP FM Chirp
J1
ASDP U2A19
Status:REX PSSDP PSUPSOver TempCPI ActiveFrame CountCPI Fault
TestSignals to RIC
Front Panel
DWG
Local Oscillator U2A5
Freq Sel Mult
Div
COHO
124.2816
E C B A
3224.32 – 3424.32A
Hi Filt
2:1Comb
497.1331.07
5.182.59
F1
F2
F4
F3
J23.88Mhz
J327.19Mhz
J1 +5dBmRF Mon
Up Converter U2A6
524.32Mhz
15db 14db 37dbWaveformSelect
1:2Div
F3/F4
F1/F2
Lo Filt
To Stability Monitor A2
RF DriverU3A10 Chan B
2.7 – 2.9 GHz2.8us SP
89us LP FM Chirp
NTIA Filter U1A12
NTIA Filter U2A12
BCDE
BCDE
J1
PS U4A6A3 42V
PS U4A7A3 42V
1:2Div
U3A2
1:4Div
U3A15
1:4Div
U3A13
U4DC1
U4DC2
RF Amplifier 1U3A6
J1
RF Amplifier 2U3A7
J1
RF Amplifier 3U3A8
J1
RF Amplifier 4U3A9
J1
RF Amplifier 5U3A1
J1
RF Amplifier 6U3A2
J1
RF Amplifier 8U3A4
J1
RF Amplifier 7U3A3
J1
87W
87W
87W
87W
87W
87W
87W
87W
U4SW1
PS U4A7A1 36V
PS U4A7A2 36V
PS U4A6A3 36V
PS U4A6A1 36V
PS U4A5A1 36V
PS U4A4A1 36V
PS U4A4A2 36V
PS U4A4A3 36V
2:1
2:1
2:1
2:1
2:1
2:1
2.45KW
2.45KW
2.45KW
2.45KW
2.45KW
2.45KW
2.45KW
2.45KW 4.9KW
2:1
4.9KW
4.9KW
4.9KW
9.8KW
9.8KW
U3A12 8:1 Combiner
U4AT2
1.1 – 2.5µs SP19.5KW Min
89µsLP18KW Min
TO U6DC1
Driver A Mon/DivU4A20A1
Detected Driver Sample to TCMM RF Mon Chan A U4A2A4
Driver RF for Testing toStability Mon U1A2
U4AT6
Driver B Mon/DivU4A20A2
Detected Driver Sample to TCMM RF Mon Chan A U4A2A4
Driver RF for Testing toStability Mon U1A2
Figure FO-3. PSR Transmitter Sheet 1 of 18
CHANNEL A
CHANNEL B
Test
SHORTN2
Test Sh 31
Sh 32
SHORTN
Sh 31
Sh 3
Sh 73
Sh 34
Sh 73
Sh 34
Sh 25
Sh 36
Sh 36
Switch
Switch
SWCONTR
Wavesel
Adjust for -17dBmAt Stab Mon
Adjust for -17dBmAt Stab Mon
+14dBm
+14dBm +14dBm
+14dBm
1:2 DivU6A4
Ant Rev
1:2 DivU6A2Fwd
U6AT4
From Sheet 1U3A12
8:1 Combiner
PSR Transmitter Sheet 2 of 18
U6DC1Bi Directional Coupler
U6DC2Bi Directional Coupler
3dBU6AT2
3dBU6AT1
1:4 DivU6A1
1:2 DivU6A3Rev
FWDREV FWDREV
3dBU6AT3
TermU6AT8
CIRCULATORU6HY3
U6AT5Waveguide
Dummy Load
Channel B Detected RF Power levels Forward and Reverse to TCMM RF Monitor Card in Unit 4
Channel A Detected RF Power levels Forward and Reverse to TCMM RF Monitor Card in Unit 4
U6Z2ReceiverProtector
TO RF AssemblyREX Channel B
Chan 3 Weather Hi/Lo to RF Assembly U1/2A1 (Coax)
Low BeamTransfer SwitchU6S1
Rotary JointU35A6
LB
HB
Polarizer
Polarizer
CompressorDehydrator
U18
WXHi/Lo Switch
Orthagonal Port
Orthagonal Port
Bull Gear
Pinion
ClutchGear Box
Drive Motor
A
Pinion
ClutchGear Box
Drive Motor
B
Wx Hi/LoCommand/
Status
WGTransition
Chan 2 Target Hi to RF Assembly U1/2A1 (Waveguide)
Chan 1 Target Lo to U6DC2 (Waveguide)
Chan 4 MSSR SUM Channel (Coax)
Chan 6 MSSR Difference Channel (Coax)
Chan 5 MSSR Control Channel (Coax)
CoaxialTransition
CoaxialTransitionCoaxial
Transition
Pre
ssur
ized
to
rado
me
Target HiTransfer SwitchU6S2
Weather Hi/LoTransfer SwitchU6S3
REX B U2
REX A U1
REX B U2
REX A U1
MS
SR
LV
A A
nten
na2.
8 de
gree
s B
eam
wid
thP
SR
Ant
enna
1.4
D
egre
es B
eam
wid
th
TO RF AssemblyREX Channel A
To/FromSelected
Channels RF Assembly
U6AT6
U6AT7
CoaxialTransition
U6Z1 ReceiverProtector
LimiterZ3
LimiterZ6
LimiterZ5
LimiterZ4
To MSSR
SUM
Difference ∆
Control ΩTo Chan A Stab Mon
To Chan B Stab Mon
Tx Sample to U3 J1
1.1 – 2.5µs SP19.5KW Min
89µsLP18KW Min
Sh 812
Sh 15
Sh 37
Sh 37
Sh 38
Sh 38
Sh 39
Sh 39
Sh 310
Sh 311
Sh 311
Sh 713
Sh 713
PSR Receiver/ASDP Sheet 3 of 18
A3DC1
RF Assembly U1/2A1
Tgt Lo
Wx Hi/Lo
Tgt Hi
A1DC1
A2DC1
1:3
Divider
1:2
Divider
STC A3Z1
STC A1Z1
STC A2Z1
Isolator
A2HY1
5µs
Delay
20dB
A3AT1A2AR1
A3AR1
A1AR1
A2AR1
Interface
Regulator
CCA A4
30dB
LNAs
Stability Monitor U1/2A2
Driver Sample
Up Converter
Tx Sample
Test Path
Test Source
Wx Hi/Lo Ctrl & Status
Tgt Hi/Lo SelectTest
from Sync A B C
J2 J3 J1
14 Bit
A/D
I/Q
Proc
D
163.88
Target Down Converter U1/2A4
P/O Radar Data
Interface
Test
EPROM
I/Q from
Stby Chan
I/Q to
Stby Chan
(5) Doppler
Filters -54dB
(5) CFAR
Doppler
Merge
14 Bit
ACP
Counter
Test
from Sync
A B C
J2 J3 J1
14 Bit
A/D
I/Q
Proc
D
16
163.88
Weather Down Converter U1/2A3
P/O Radar Data
Interface
Test
EPROM
I/Q from
Stby Chan
I/Q to
Stby Chan
Frequencies in MHz:
A = 3224.32 – 3424.32
B = 497.13
C = 31.07
D = 5.18
Point Tgt
Censor
Clutter & AP
Reject Filter
P/O Radar Interface CCA U1/2A9A10
Range
Smoothing
Map
Generation
Map
ContouringWx Data
To SBC
Serial ACP/ARP
From FMACParallel ACP Count
To DSP
Frequencies in MHz:
A = 3224.32 – 3424.32
B = 497.13
C = 31.07
D = 5.18
WEATHER
TARGET
Tgt Data
To SBC
End to End
Test Results
End to End
Test Results
Coefficients
Tgt Hi/Lo RF
We
ath
er
Hi/L
o R
F
Sta
bili
ty M
on
Te
st R
F
Sta
bili
ty M
on
Te
st R
F
P/O
VM
E6
4x B
US
P/O VME64x BUS
P/O VME64x BUS
Sh 16
Sh 14
Sh 211
Sh 29
Sh 28
Sh 27
Sh 210
Sh 11
Sh 11
Sh 413
Sh 413
-17dBm Upconverter
-15dBm Driver
-13dBm Transmitter
-18 dBm
-28dBm
34dB Gain 69dB Gain
Approx
+14 dBm
Gain -30dB
0-72dB
-28dBm
-23dBm
P/O FDP Cable
Weather Alarms
Radar Timing
Synchronizer FPGA
Long Pulse
Compression
Long Pulse
Compression
Target Processing
Weather Processing
Beam and STC
Control & Status
Target and Weather Beam
and STC control to REX
Timing to other channel
Triggers to Front Panel
REX, UPS, Power Supply Status
RIS
Processing
16
P/O FDP Cable
Target Alarms
Sh 416
Control/Status and Maps to/from ASDP
P/O Radar Interface CCA U1/2A9A10
16
16
DSP CCA U1/2A9A8
Fixed STC
(Tgt & Wx)
Clutter
Maps (5)
Merged STC
(Target 0nly)
When 0 Clutter saturates
STC is added
STC/Clutter Map Processing
Adaptive STC
Short Pulse
Only
ASDP SBC/SCDIs Fiber Option Sheet 4A of 18
SBC U1/2A9A01
Tgt Plot
Processor
Wx Plot
Processor
Tracker
Binary
Integrator
VM
E B
US
Doppler
Adaptation
138.1.1.3
138.1.2.3
138.1.1.4
138.1.2.4
LAN A
LAN A
Gigabit Switch
U7A6A1
LAN B
LAN B
Gigabit switch
U7A9A1
5VPS
U7A26
5VPS
U7A27
SCDI AU7A3
4-Port Ethernet
1 2 3 4
U7A4
SCDI B
1 2 3 4
4-Port Ethernet
SCDI A 138 LAN A
138.1.1.1 138.1.2.1 10.1.1.10 10.1.2.10
138.1.1.2 138.1.2.2 10.1.1.11 10.1.2.11
Se
rial
Po
rt
FMAC Chan A
U7A1
See Detail Sheet 6
24VPS
U7A10
Se
rial
Po
rt
FMAC Chan B
U7A2
See Detail Sheet 6
24VPS
U7A11
SCDI A 10 LAN A
LAN A
4 Port Switch
U7A6A2
Channel UPS
220VAC
U2A10
Channel UPS
220VAC
U1A10
Reset
Relay
U7A16
Reset
Relay
U7A17
ASDP PS
U1A9A13
REX PS
U2A11A2
ASDP PS
U2A9A13
UPS 220VAC
A/B
Switch
MPS-800 Server
U7A7
MPS-800 Server
U7A10
LAN B
4 Port Switch
U7A9A2
UPS 220VAC
UPS Status
UPS Status
Reset Command
From SCDI B
Reset Command
From SCDI A
Chan A/B Asterix Data
Chan A/B Asterix Data
Chan A/B Control & Status
Chan A/B Control & Status
22
0V
AC
PS
22
0V
AC
PS
Se
rial
Po
rt
Se
rial
Po
rt
Pa
ralle
l
Po
rtM
on
ito
r
Po
rt
Pa
ralle
l
Po
rt
Mo
nito
r
Po
rt
Kb
d
Mo
use
Kb
d
Mo
use
FUNCTIONS:
1. Combiner
2. Formatter
3. Cont & Mon
FUNCTIONS:
1. Combiner
2. Formatter
3. Cont & Mon
10.1.2.21
10.1.1.20
TCMM Comms
Port J1
MS
SR
Coefficients
To Doppler
Filters
220VAC
REX PS
U1A11A2220VAC
Sh 921
Sh 920
ACP/ARP
Sh 316
ACP/ARP
SCDI B 138 LAN A
SCDI B 138 LAN B
SCDI A 138 LAN B
SCDI B 10 LAN A
Sh 518
Sh 519
SCDI A 10 LAN B
SCDI B 10 LAN B
FO
Tx/R
xF
O T
x/R
x
Single Mode Fiber to Remote Site
Single Mode Fiber to Remote Site
LAN A
LAN B
Tracks
Plots
Weather
+/- 18.5VDC
+/- 8.0 VDC
+/- 18.5VDC
+/- 8.0 VDC
Status
And
Control
Sh 313
Sh 313
TX/Rx data RS-232
To SBC 1 TCMM COMMS Port J1
TX/Rx data RS-422
TCMM Status & Control CCASh 514
Sh 316
422/232
Conv
U13
I/O Transition CCA
U1/2A9A23
J1
J13
Chan/Chan
Termination
ASDP SBC/SCDIs Telco Option Sheet 4B of 18
SCDI AU7A3
4-Port Ethernet
1 2 3 4
U7A4
SCDI B
1 2 3 4
4-Port Ethernet
138.1.1.1 138.1.2.1 10.1.1.10 10.1.2.10
138.1.1.2 138.1.2.2 10.1.1.11 10.1.2.11
Se
rial
Po
rt
Se
rial
Po
rt
SCDI A 10 LAN A
LAN A
8/24 Port Switch
U7A6A2
A/B
Switch
MPS-800 Server
U7A7
MPS-800 Server
U7A10
LAN B
8/24 Port Switch
U7A9A2
Chan A/B Asterix Data
Chan A/B Asterix Data
Chan A/B Control & Status
Chan A/B Control & Status
22
0V
AC
PS
22
0V
AC
PS
Se
rial
Po
rt
Se
rial
Po
rt
Pa
ralle
l
Po
rtM
on
ito
r
Po
rt
Pa
ralle
l
Po
rt
Mo
nito
r
Po
rt
Kb
d
Mo
use
Kb
d
Mo
use
FUNCTIONS:
1. Combiner
2. Formatter
3. Cont & Mon
FUNCTIONS:
1. Combiner
2. Formatter
3. Cont & Mon
10.1.2.21
10.1.1.20
MS
SR
Sh 921
Sh 920
SCDI B 10 LAN A
Radar LAN A Router
Sh 518
Sh 519
OMT Router
Radar LAN B Router
LA
N A
LA
N B
TELCO
Fractional
T1
TELCO
56kDDS
TELCO
Fractional
T1
SCDI A 10 LAN B
SCDI B 10 LAN B
OMT
Radar LAN A Router
OMT Router
Radar LAN B Router
A
B
B
A
138.1.1.3
138.1.2.3
138.1.1.4
138.1.2.4
LAN A
LAN A
Gigabit Switch
U7A6A1
LAN B
LAN B
Gigabit switch
U7A9A1
5VPS
U7A26
5VPS
U7A27
SCDI A 138 LAN A
FMAC Chan A
U7A1
See Detail Sheet 6
24VPS
U7A10
FMAC Chan B
U7A2
See Detail Sheet 6
24VPS
U7A11Channel UPS
220VAC
U2A10
Channel UPS
220VAC
U1A10
Reset
Relay
U7A16
Reset
Relay
U7A17
ASDP PS
U1A9A13
REX PS
U2A11A2
ASDP PS
U2A9A13
UPS 220VAC
UPS 220VAC
UPS Status
UPS Status
Reset Command
From SCDI B
Reset Command
From SCDI A
220VAC
REX PS
U1A11A2220VAC
Sh 316
ACP/ARP
Sh 316
ACP/ARP
SCDI B 138 LAN A
SCDI B 138 LAN B
SCDI A 138 LAN B
+/- 18.5VDC
+/- 8.0 VDC
+/- 18.5VDC
+/- 8.0 VDC
TX/Rx data RS-422
TCMM Status & Control CCASh 514
SBC U1/2A9A01
Tgt Plot
Processor
Wx Plot
Processor
Tracker
Binary
Integrator
VM
E B
US
Doppler
Adaptation
TCMM Comms
Port J1
Coefficients
To Doppler
Filters
Tracks
Plots
Weather
Status
And
Control
Sh 313
Sh 313
TX/Rx data RS-232
To SBC 1 TCMM COMMS Port J1
422/232
Conv
U13
I/O Transition CCA
U1/2A9A23
J1
J13
Chan/Chan
Termination
Remote Site Sheet 5 of 18
SDT-A
24 Port Flex SwitchLAN A**Single Mode Fiber
from Local Site
LAN B* 24 Port Flex Switch
Eth
erne
tTr
ansc
eive
r
SBC
NIC LAN A
NIC LAN B
UNIO ARTS A
UNIO ARTS B
DVG LAN A Hub
OFF
SIT
E L
AN
A
OFF
SIT
E L
AN
B
10.1.1.33
10.1.2.33
SDT-BE
ther
net
Tran
scei
ver
SBC
NIC LAN A
NIC LAN B
UNIO ARTS A
UNIO ARTS B
DVG LAN A Hub
10.1.1.49
10.1.2.49
10.1.1.14
10.1.2.14
*Single Mode Fiberfrom Local Site
OMT 1Short Haul
ModemShort Haul
Modem
TRACON RCP
TOWER RCP
Nunio Hub Nunio10.1.1.32
10.1.2.32
SIU-AModem
56k DDSModem
56k DDSModified
CD-2 FormatARTS IIIE
STARS
Nunio Hub Nunio
SIU-BModem
56k DDSModem
56k DDS
Maint Port96008 bit
NoneXon/Xoff
Maint Port
96008 bit
NoneXon/Xoff
DVG-1 DVG-2
DVG LAN A
DVG-5
DVG LAN B
DVG6-12
SMC
TELCO
TELCOModifiedCD-2 Format
Local Control
Unit LCU
Remote Control
Unit RCU
SWITCHPair 1
192.
9.20
0.1
192.
9.20
1.1
MAPPER
192.
9.20
0.2
192.
9.20
1.2
DVG-3 DVG-4
SWITCHPair 2
192.
9.20
0.3
192.
9.20
1.3
D-BRITE
192.
9.20
0.4
192.
9.20
1.4
ARTS IIE
J11J15J19
SDT Chassis
J09J13J17
J12J16J20J10J14J18
SDT-A B Output Modified CD-2 Data
DVG LAN A
DVG LAN B
CMC
SDT-A A Output Modified CD-2 Data
SDT-B B Output Modified CD-2 Data
SDT-B A Output Modified CD-2 Data
192.
9.20
0.20
119
2.9.
201.
201
Alpha Numerics
Reconstituted Raw Beacon
192.
9.20
0.50
192.
9.20
1.50
192.
9.20
0.5
192.
9.20
1.5
192.
9.20
1.6-
12
Control Unit
VDCU VDCU VDCU VDCU
Search PretriggerDaisy chained
SearchPretrigger
ACPsARPs
TriggerSearchBeaconWeatherACPs/ARPs
Search PretriggerSearch VideoBeacon VideoWeather Video
ACPs/ARPs
Alpha N
umerics
Alpha N
umerics
Sh 418
Sh 419
192.
9.20
0.6-
12
PSR FMAC Sheet 6 of 18
P/O PedJunction Box
U16
A5,6,7,8,9,10Input Modules
FMACJunction Box
U31A20
FMA
C In
terfa
ce U
7A15
Antenna Commands-Linear Polarization Select-Circular Polarization SelectAntenna Status-Beam Switch-Obstruction Light-LB Circular/Linear-HB Circular/Linear
Pedestal Control-Local Control EnablePedestal Lube Status-Pedestal Temp-Sump Oil Level-Gearbox A/B Overtemp-Gearbox A/B Oil Level-Encoder X/Y PS
E/G Control-Emergency Power Off-Run/StopE/G Status-System Ready-Running-Minor Trouble (Alarm)-Major Trouble (Shutdown)-Transfer Switch Status-Fuel Tank Level Not Low-Fuel Tank Not Leaking-Transfer Switch Om-Commercial Power
UPS Control-Emergency Power OffUPS Status-On Inverter-Load On-Battery Low-I/P Voltage Failure-On Battery-Summary Fault-MDP CB1 (UPS Rect,IP-Closed
Fire Alarm Controller-Radar Room Temp Normal-Radar Room No Smoke/No Fire-Pedestal Room No Smoke/No Fire-E/G Room Temp Normal-E/G Room No Smoke/No Fire-Pedestal Room Temp-Fire Alarm System Trouble-Overall Fire Alarm Status
Antenna 24 Volt Status-Stow Pin-Safety Switch-Hatch-Hand Crank-Interlock D Complete-24 Volt A/B PS
Motor A/B Control-Stop/Start Motor A Rotation-Stop/Start Motor B Rotation-Motor A/B ResetMotor A/B Status-Motor A/B Run-Motor A/B Speed-Motor A/B Overtemp-Motor A/B Current-VSD A/B Alarm
Site Status-AC 1-4 Not Failed-Main CB ClosedDoor Closed-Site Gate, Radar RoomPedestal Room, E/G RoomTemperature Status-Radar, Pedestal,E/G Room
Compressor Dehydrator Status-WG Pressure Status-Compressor Status-Dehydrator Status
Heat & Smoke Detectors
Transmitter Power MonitorTo A/D Converter A10-A Short Pulse-A Long Pulse-A Reverse-B Short Pulse-B Long Pulse-B Reverse
P/O I/O PanelU7A14
A11,12Output Modules
FMAC A U7A1
Azimuth Distribution
A15A17 A16
A14PS
Az Data fromEncoder X & Y
Relay Control to SCDI A Relay FMAC B U7A2
Azimuth Distribution
A15A17 A16A14
PS
Az Data To MSSRand PSR Chan B
A1Power Supply
A2CPU
A3RS-232 Comm
Module
To SCDI ASerial Port
A5,6,7,8,9,10Input Modules
A11,12Output Modules
A1Power Supply
A2CPU
A3RS-232 Comm
Module
To SCDI BSerial Port
P/O
I/O
Pan
elU
7A14
FMAC 24 V PS220VAC
FMAC 24 V PS220VAC
Relay Control to SCDI B Relay
Az Data To MSSRand PSR Chan A
Sh 4
Sh 4
Sh 4
Sh 4
Sh 4
Sh 4
FOR MORE DETAIL, REFERENCE:PSR Manual TI6310.57 Table 2-19
PSR TCMM Sheet 7 of 18
TransmitterControlChan AU4A2A2
TransmitterStatusChan AU4A2A3
TransmitterRF Monitor
Chan AU4A2A4
TransmitterControlChan BU4A2A5
TransmitterStatusChan BU4A2A6
TransmitterRF Monitor
Chan BU4A2A7
Low Beam SwitchU6S1
High Beam SwitchU6S2
Weather SwitchU6S3
Driver Select SwitchU4S1
Tx Amp Power Supplies (8)
Tx Driver APower Supply
Chan A I/O Transition
RS-422 – RS-232Link to ASDP
Ch ARF GATE
CH. SEL
S1 Ch AON
S2 Ch BON
Ch BRF GATE
A
B
TCMM Circuit Card Location
Pedestal SafetyInterlock
Input Disable N
ot
Dis
able
Out
Low Beam
High Beam
Weather
Driver
Cha
nnel
Cha
nge
Sw
itche
s
Switch Status
Interlock Chain
-Driver Select Indicator-High Beam Indicator-Low Beam Indicator-Weather Indicator
Tx Amp Modules (8)
Tx Driver BPower Supply
Alt
RF
Driv
er F
ail
RF DetectorsU6
-Antenna Reverse Power-Transmitter Reverse Power-Selected Driver Power-Transmitter Group Power
Driver LED
RF Gate Front Panel Not
RS-422 to FMAC A/D
-A/B Short Pulse-A/B Long Pulse-A/B Reverse
-Weather Position Fault-Low Beam Position Fault-High Beam Position Fault-Driver Position Fault-Antenna Reverse Power Fault-Trans Reverse Power Fault-Pulse Width Fault-Duty Cycle Fault-Interlock Fault-Driver RF Power Fail-LP Pulse Width Range MSB-LP Pulse Width Range LSB-SP Pulse Width Range MSB-SP Pulse Width Range LSB
TransmitterCabinet U3
Cabinet UndertempCabinet UndertempWarning 1
5/30 V Power Supplies
Power SupplyDC 1/2 Fault
Power SupplyDriver 2 Fault
Tx Driver AModule
Power SupplyDriver 1 Fault
Amp RF OutSum Fault (8)
Power SupplyFault
Driver RF OutSum Fault
Power SupplyDriver Blank
-RF Gate (8)-RF On (8)
-RF Gate-RF On
Power SupplyBlank
RXD
TXD
RS
-422
RS
-422
Alternat DriverRF Power Fail
Emergency Inhibit Not
-Emergency Inhibit Reset Not-RF Gate Out-Enable Out Not-Blank
NOTE:This drawing is showing Channel A connections and not channel BThe Chan B TCMM cards are shown only as a reference to Chan A
Sh 6
Sh 2
Sh 4
CO
NTR
OL
STA
TUS
RF
MO
N
CO
NTR
OL
STA
TUS
RF
MO
N
CHAN A CHAN B
From CHAN B RF Mon
Driver LED
+5V+30V-15V
+5V+30V-15V
+5V,+30V,-15VPower Supply
4A3A1
+5V,+30V,-15VPower Supply
4A3A2
+30VCB32
+30VCB35
S1C S2C
+5VCB31
+5VCB34
S1B S2B
4A2A
8-E
5V1
4A2A
8-E
6V2
-15VCB33
-15VCB36
S1A S2A
4A2A
8-E
7V1
4A2A
8-E
8V2
4A2A
8-J6
5-1
4A2A
8-J6
5-2
BA
CP
LAN
EB
ehin
dC
B P
anel
LOOPDATARS-232
P1 C23 P1 C11
Driver Module 807888/005
Transmitter Interface 807890/010
PE and Receiver Frame Assembly 808282/058
Control and BIT 807893/002
Fan and Power Supply Unit808363/000
RFCO 808499/054
Mode Generator 808163/003
VCO/ Modulator
Low Duty Cycle Power Amplifier 808125/003
D26
D23
D20
D21
D19
D16
D17
D18
TX Power Supply808316/001
+52V
Multi Output Power Supply808315/001
+5V+28V+/-15V-5.2V
Fan Fail 808364/002
Transmitter BIT: Driver Phase/AmplRF Pulse AmplitudeRF Pulse WidthOvermodulation
Power Supply BIT:Power Supply FaultsFan FailPSU Overtemp
Receiver BIT: Gain 3 dB High or LowNoise MonitorLocal Oscillator
Coupler
Coupler
Σ Fwd
Ω Fwd
Σ R
ev
RF Detector
Temperature Sensor Assy
Monitor/ Regulator
1.25 kW 3.8 kW80 W
System Trigger
14 Bit AzimuthFrom VT
ModulationPulses
RFCO Select/Fault
LRU Fault IndicationSee TI 6310.53
Section 2.8 Table 4
+15
-12
+12
-15PSU Shutdown
Status/Mode In
Status/Mode Out
J27
J28
J29
Coupler
Mode Idents/ Mode Bits
J32
J47
1030 MHz CW Signal used for SSR Transmissions and Receiver LO
1. Produces all Interrogation Pulses
2. Disables Transmitter Output during Sector Inhibit and RF OFF.
3. Generates Mode B with receipt of APM Trigger
4. Generates Triggers:
Internal 50 – 500 HzSelf Test @ P3-32μsSystem @ P3-143μsDisplay @ P3+4μsSTC and RG @ P3+3μsVT/PE @ P3-30μsSLS @ 0-1.5µs before P2
1. Monitors Fan Current:FAN FAIL 1 and FAN FAIL 2 Signals2. Monitors +5V Current from MVPS3. Provides +65V Reference for LDPA Regulator4. Provides -70 for PIN Diode Switch in TX Interface
APM Trigger16MHz Clk
Synth Tgt Modfrom VT
1. Responds to Control Information from asynchronous RS232 Serial Data Link
2. Transfers Control Information to appropriate LRU
3. Loads Site Parameters across Serial Data Link and Stores in EEPROM. Programs Mode Gen with PRF and MIP.
4. Monitors System Parameters and Sends Fault Message to PE.
5. Reports Opposite Channel Status to PE. Performs Channel Change when instructed by PE.
6. Provides Local Interface for FIT Results
10W
10W
10W
1030
MH
z LO
1030 MHz
SK31030 MHz
PRF/Mode Interlace Pattern
Site Services Interface 808366/000
Sel’d Mode
This Chan Status/ Opp TX Disable
This TX Disable/Opp Chan Status
To VT
Plot Extractor ProcessorSBC 808365/0011. Status Monitoring2. FIT3. Instigates Channel Change4. Flash EPROM stores Commissioned Set
8
RS
232
Condor MSSR Interrogator 808136/005
+28
Band Pass Filter
Self Test Oscillator
Self Test Coupler
Fwd Pwr Coupler
1:3 Divider
SLS PIN Diode Switch
0-15 dB
Log Amp 1 of 4 Select
STO Modulation/ 30 dB In/Out
from Mode Gen
Front Panel Sensitivity Adjust
Front Panel Power Adjust
TX Samples to Control & BIT
DetectedTX Samples
90° Phase Shift
SLS Switch Gatefrom Mode Gen
1. 4μs Pulse at -53dBm during RX Self Test(P3 - 32μs)2. SIF and M-4 Reply Pulses at -83dBm on Standby Channel
1090 MHz
Fwd/Rev Sel/SLS Trig from Mode Gen
Self Test Coupler
Self Test Coupler
Fwd Pwr Coupler
To Receiver Modules
To/From Channel B
ToAntenna
Σ
Ω
Δ
Σ
Ω
Δ
Ω R
ev
4 Cooling FansTo TX
Interface
12dB 5dB
+52V
BIT
BIT
BIT
BIT
BIT
J5PL1
PL2
Σ Ω Δ
RFCO Select
Σ Ω Δ
Display Trigger
Mode Idents
J15 J14 J12
TP1 TP5
Mod TTL
SLS Gate
J32
J47To
Control & BIT via Site
Services Interface
BITDetected RF SamplesTemperature Faults
Regulator OvercurrentTo Control & BIT
MSSR Transmitter Sheet 8 of 18
To RX Interface
A
A
A
A
From Receiver Modules
TX Samples from TX Interface
B
B
C
C
C
C
J10
TX Enable from Pedestal I/F Panel
Mode
+52V Inhibit Sh 412
Sh 412
Sh 412
Sh 10
Sh 923
Sh 924
Sh 925
Sh 926
Sh 927
PE and Receiver Frame Assembly 808282/058
Control RX 807891/001
Difference RX 807891/001
Sum RX 807891/001
32
Site Services Interface 808366/000
Receiver Interface Assembly 807899/002
Video and Timing807894/006
Reply Decoder 807896/000
Plot Extractor Processor Single Board Computer 808365/051
Daughter Card 808365/052
1:3Divider
A/D A/D A/D
Control & Monitor System (CMS)
J48
J38
J49
J44
J39
J43
J33
Ch 0 – Cross-Channel Comm (Data/Control)
Ch 2 – Target Reports to SCDI-B
Ch 5 – Control/Status to SCDI-A
Ch 6 – Target Reports to SCDI-A
Ch 7 – Data (Not Used)
Ch 3 – Data (Not Used)
Ch 1 – Control/Status to SCDI-B/CMS
Mul
tibus
II
PCI Bus
Clock Fail
PRF Fail
Self Test Fail
Azimuth FailSynthetic Data
Video Self Test
Synthetic Target
North Ref
Invalid Mode
ACP Warning
System Test
SIF Bracket Detect
M4 Triplet Detect
Σ 8-Bit Video
Δ 8-Bit Video
Ω 8-Bit Video
PCB OK
BIST RUN Error
Video Mon
Σ 60 MHz IF Δ 60 MHz IF
Monopulse Sign Bit
Confidence Bit
1. Video Processing
2. Thresholding
3. Bracket Detection
4. Reply Decoding
5. SVA/SDR Generator
6. Azimuth Counter
7. STC Application
8. RSLS
9. Defruiter/Degarbler
10. Range Zero Determination
14-Bit Azimuth
1030 MHz LO from Driver Module
14-Bit Azimuth to Control &
BIT
16 MHz Clock
1090 MHz Rx Signal from Transmitter Interface
Replies and Status Data BlocksMode, Code, AZ, Range
1. Reply-to-Reply Correlation
2. Scan-to-Scan Tracking
3. False Target Elimination
4. Target Formatting
5. Status Monitoring
6. Interfaces w/ Opp. Channel Plot Extractor
7. Flash EPROM stores Commissioned Set
Comms Links:
1. ASTERIX Formatted Target Reports
2. Cross-Channel Communications
3. Status and Control to CMS/SCDI
Phase Monitor4μs Zero Beat Signal
at P3-32μs
J7
14-B
it A
zim
uth
Azimuth Data In from FMAC A
Cont/Status
Phase Detect
RL180° 0°
1. 16 MHz Clock
2. Interfaces signals from RXs and Mode Gen to Reply Decoder
3. Self Test and Synthetic Target Data Generator
4. Initiates APM
5. Azimuth Data Distribution
6. Monitors AZ Data, Triggers, and Clocks
7. Distributes System Reset with S/W Reset
8. Invalid Mode Interrupt
Σ/Δ Phase Relationship
BS
C:\CMS
\TMC \TML \CHL \SET \APM
CHAN_A.TMCCHAN_B.TMC
SITE.TMC
A*.SET
B*.SET
1. Divides 1030 MHz LO
2. Provides Monopulse Sign Bit (Right =1, Left = 0)
3. Provides Confidence Bit (BS +/- .22° = 0)
RF Amp 14 dB
IF Amp 18 dB
Log Amp80 dB
MAKES A TARGET REPLY FOR EACH AIRCRAFT DETECTED
8-Bit Video
J34
Ch 4 – Cross-Channel Comm (Data/Control)
To/From Channel B
A/B
Video Mon
Video Mon
Condor MSSR Interrogator 808136/005
BIT
To Control & BIT
Target Message Format:TI 6310.56, Section 4, Annex A Tables 6 and 7
CORRELATES ALL REPLIES WITHIN A GROUP Raw and
Polished Target
Messages
16
Mode Bits
16 MHz Clock
Range Zero Pretrigger
Monopulse Sign
To Mode Generator:APM Trigger16MHz Clk
Synth Tgt Mod
Mode Idents/Bits from Mode Generator
From Mode Generator:
VT Trigger @ P3 - 32μs
From Site Services Interface:
Selected Mode BitsS/W Reset
Multibus II Reset
Internal Reset
Mode Bitsto VT
Sel’d Mode
S/W Reset
/CRST to PE
From Site Services Interface:
/CRST Reset
To PE
J33
J34
`
MPS800B
MPS800A
B
B
MSSR Receiver Sheet 9 of 18
A
RX BIT: RX Gain +/- 3 dBNoise MonitorAnalog to Digital FaultLO Monitor
Monitor Panel
BP
Mode Idents
Bracket Detect
SIF PSV
Triplet Detect
Bracket Detect Selected Mode Idents
CH 0 Debug Port
J2
Azimuth Out
32
To VT
A
SW1
Modeto/from
Opp Ch
Mode Selection from Multibus
J10
Rad
ar B
lank
ing
Mul
tibus
II In
terfa
ce
PCB OK
TX Enable from Pedestal I/F Panel
ADG/NMK Faults
J7
Range Listening Interval
BIST RUN
PL62 to PE SBCPL663 ½” Disk Drive
J38
A/B
01
00
Sh 827
Sh 826
Sh 825
Sh 824
Sh 823
Sh 10 Sh 6
Sh 420
Sh 421
ANTENNA PEDESTAL STATUS Sheet 10 of 18
A
S3Status
S2GB OL
GB OT
Pinion
MotorOT
Clu
tch
Gea
r Box
Driv
e M
otor
AU
35B
1U
35A
1
3 Ret4 Sig1 +24
S3Status
S2GB OL
GB OT
Pinion
MotorOT
Clutch
Gear B
oxD
rive Motor B
U35B
2U
35A2 Ret 3
Sig 4+24 1
S2J2 S2J2
B
Junc BoxU35A4
1
3
A
B
A
B
A B
4
1
3
Motor A Overtemp - A
Motor A Overtemp - B
Gearbox A Overtemp - A
Clutch A Engaged - 3
Gearbox A Overtemp - B
Clutch A Engaged - 1
Gearbox A Oil Level
24v
24V Return
A
TB2
1
2
3
4
5
6
7
8
9
10
4700
Junc BoxU35A5
4
1
3
Motor B Overtemp - A
Motor B Overtemp - B
Gearbox B Overtemp - A
Clutch B Engaged - 3
Gearbox B Overtemp - B
Clutch B Engaged - 1
Gearbox B Oil Level
24V
24V Return
B
TB2
1
2
3
4
5
6
7
8
9
10
4700
Pedestal U35
24V Return
24V
Sump Oil LevelC
3
1
4
35A6S6 -10CPed Low Temp
SUMP/BULLGEAR
DPed Lo Temp
Ped Lo Temp Ret
Pedestal JB
U35A3TB2
TB3
J1
1
2
3
4
5
6
7
8
9
10
1
2
3
4
5
6
7
24V R
et
G
K
N
L
P
H
F
J
U
S
Q
10
9
8
TB4
4700
Pedestal Local Control Panel
U34
A1 Oil Level Transition Module
GB AOil
Level
24V
GB BOil
Level
0V
0V TB3-23
24V
G
K
N
L
P
H
F
J5
J
U
S
Q
J17
J18
Motor A Overtemp
0V 7A15 FIP
Motor B Overtemp
24V 7A15F2
0V 7A15Status Ret
J16Clutch A
Clutch B
GB A OT
GB B OT
J
H
B
A
D
SumpOil
Level
0V
G
C
1
3
A
B
A
B
CRet 3Sig 4+24 1
35S2Sump Oil Lvl
Ped Lo Temp
Ped Lo Temp RetD 10
4K5
TB3-9 0V(7A15)
TB3-13 24V(7A15F2)
Pedestal Temp LoM M
TB3-13 24V(7A15F2)
W1701C
T
K
S
f
N
S
H
F
G
A
B
D
C
A3A5-E2/L2
A3A11-N
A3A4-E1/L1
A3A11-L
A2A6-E2/L2
A2A7-E1/L1
A1A11-N
A1A8-E1/L1
A1A7-E1/L1
A1A10-E2/L2
A1A10-E1/L1
A1A9/E1/L1
A1A9-E2/L2
T
K
S
f
27
17
26
1
N
S
H
F
G
A
B
D
C
5
3
11
4
12
2
1
TransientProtection
U31A12
16
19
TransientProtection
U34A1
A2A9-E1/L1
A2A11-N
A2A9-E2/L2
A2A11-L
A2A1-E2/L2
A2A2-E1/L1
A1A5-N
A1A3-E2/L2
A1A3-E1/L1
A1A4-E2/L2
A1A4-E1/L1
A1A2-E2/L2
A1A1-E2/L2
T
K
S
f
T
K
S
f
N
S
N
S
H
F
G
A
B
D
C
H
F
G
A
B
D
C
W1701B W1701A
W1601C W1601B W1601A
W1802C W1802B W1802A
Motor O
T Ret
PedestalInterface
U16
27
17
26
1
J6 J3 J6 J12 J8
J5 J2 J5 J11 J5116
19
J4 J1 J2 J85
3
16
4
17
2
1
J10
Clutch A
Clutch B
Motor A Overtemp J1-27
0V 7A15 FIP J9-28
Motor B Overtemp J1-8
24V 7A15F2 J9-29
0V 7A15Status Ret
GB A OT
GB B OT
GB A OL
GB B OL
Sump OL
Ped Low Temp
CEC Unit 7A15FMAC Interface
W2001
28
29
J5
0V FIP
24V F2
Motor A OT
Motor B OT
5
18
J52
W2002
ANTENNA HEATERS Sheet 11 of 18
Pinion
Clu
tch
Gea
r Box
Driv
e M
otor
AU
35B
1U
35A
1
S2GB OL
Pinion
Clutch
Gear B
oxD
rive Motor B
U35B
2U
35A2
Junc BoxU35A4
A B
Junc BoxU35A5
Pedestal U35SUMP/BULLGEAR
Pedestal JBU35A3
Pedestal Local Control PanelU34
1
2
3
4
5
6
9
10
TB1Htr 5,6,7 Phase 1
Htr 1 & 2 Phase 2
Htr 5& 6 Neutral
Htr 7& 1 Neutral
Htr 2 Neutral
GB A Htr Neutral
GB A Htr Phase 1
B
35HTR3
35HTR4
35HTR8
35HTR9
C
HTR1
B
35HTR1
35HTR7
35HTR6
35HTR5
35HTR2
HTR1
TB11
2
3
4
5
6
9
10
J3
A
B
C
D
E
C
B
A
J2
To D
P3
CB
4
TB1Htr 4 Phase 2
Htr 8,9,3 Phase 3
Htr 4&8 Neutral
Htr 9 Neutral
Htr 3 Neutral
GB B Htr Neutral
GB B Htr Phase 1
C
2
3
4
5
6
9
10
Htr Off +15C
Htr On +5C
Htr Com1
2
3
P/O TB4X
T
Y
P/O J1
K4
To D
P3
CB
1/2
/3Phase 1Phase 2
Phase 3
TB1-31TB1-32 Neutral
Ground
To D
P3
P/O J5
0V (7A15)
m
n
24V (7A15F4)
TB3-8 0V(7A15)
TB3-12 24V(7A15F2)
Off/Latch +15C
On +5C
Com
X
T
Y
35A6S6 +15CSump Htr Off
35A6S5 +5CSump Htr On
Htr Off
Htr On
Htr Com
CB
Heaters On
J17
NOTE: Wires appear to be crossed.
Will work the way it is shown
m
n
TransientProtection
U31A12
TransientProtection
U34A1
A3A12-L
A3A12-Nm
n
m
nW1701B W1701AW1701C
PedestalInterface
U16
A3A1-N
A3A1-L
J6 J3 J6 J12 J8 J921
22
21
22
31
32
7 8Test
Points
W2001To FMACJ5-31/32
ANTENNA Drive Control Sheet 12 of 18
Motor A Start
InterlockComplete
ControlRemoted
PanelControl
HeatersOn
Motor BStart
Stop Stop
Encoder X Encoder Y
Wx BiasPS Polarizer
ReleaseControl
Pedestal Local Control PanelU34
ReleaseControl S7
Pinion
ClutchGear BoxDrive Motor AU35B1 U35A1
Pinion
ClutchGear BoxDrive Motor BU35B2 U35A2
A
B
Pedestal U35
SU
MP
/BU
LLGE
AR
DP4 CB 2/4/6
DP5 CB 2/4/6
Motor Controller A
U14
Motor Controller B
U15
W00543 Phase 380VAC
W00553 Phase 380VAC
Transient ProtectionPanel U31A12A1
(Outside)
4
5
6
Mezzanine Room
1
2
3
TB4
W041B
W042B
W041A3 Phase 380VAC
W042A3 Phase 380VAC
W041C3 Phase 380VAC
Variable Frequency for Antenna Speed
Pedestal InterfaceU16
Antenna Safety SwitchU35S1
TB14
5
6
1
2
3
TB1
4
5
6
1
2
3
TB2TB2
R
S
K7
K5
K1
Stop
Start
A R
un Status
10J6 J7
K3
DriveEnable
Reset A
Interlock Com
plete
64 824 8 10
K6
B R
un Status
24
Transient ProtectionU34A1
Transient ProtectionU31A12
W042C3 Phase 380VAC
Variable Frequency for Antenna Speed
Radar Shelter
Motor A StartMotor A StopMotor B StartMotor B Stop
SCDI Control Enable
Interlock Complete
R
S
K2Stop
Start
6
K4Reset B
4
J9
12
13
47856
CR
14C
R2
CR4
CR7
CR
3
CR
13C
R1A
Interlock Complete
14+13-
12+9-
K2Shown in Local
Control
24V TB3-117A15F2
0V 7A15
24V TB3-107A15F2
11
10
Local Control EnableLocal (PLCP) Control Enable
24V TB3-137A15F2
8
45
1
S5
S6
Motor A StartMotor A Stop
Motor B StopMotor B Start
Local Control StatusDS3 DS2
ControlRemoted
DS1Local (PLCP) Control Status
Interlock Complete
A2A8-E1/L1
A2A11-E2/L2A3A8-E2/L2
A2A12-E1/L1A2A13-E2/L2A2A11-E1/L1A2A12-E2/L2A3A9-E2/L2
A2A8-E1/L1
A2A5-E2/L2A3A5-E2/L2
A2A6-E1/L1A2A7-E2/L2A2A5-E1/L1A2A6-E2/L2A2A4-E2/L2
J12 J6 J3 J6
820
J11 J5 J2 J521 U U U
J5U
J17
11129
106
Ee
HJFGC
Ee
HJFGC
Ee
HJFGC
Ee
HJFGC
W1601 B
J8
820
11129
106
W1601AJ5121
CEC Unit 77A15
24
J5
244
7856
12
24V 7A15F330
13
30
CR6
MSSR A TX Enable
MSSR B TX Enable
PSR TX Enable
J3
J5
J4
CR5
For More Details, See Pedestal Interface
U16 schematic Located in TI 6310.57
Sec 7R
A
A
28 B0V 7A1528
B
B
B
B
B
Modules may be located outside
U31A12A1
W1601 C
Sh 1328
W1701 CW1701 BW1701 A
ANTENNA Interlock Chain 13 of 18
Pedestal Local Control PanelU34
Mezzanine
Transient ProtectionU34A1
Radar Shelter
DS1InterlockComplete
Safety Switch
U35S1
Pedestal Room
Antenna
Deck H
atchU
35S3H
and Crank
U35S
4S
tow P
inU
35S2
U35A3
TB26
5
7
U35A4
10
TB4
6
5
7
10
6
5
7
TB2
J1
R
C
F
E
A
C
D
A
B
J13
J5
J15A
C
B
F
E
C
F
R
A
J16
C
TB3-23
L
J18
J1724V 7A15F1A
E
J16B
0V 7A15
Interlock Chain
Interlock Chain
Interlock Chain
Interlock Chain
Status
Status
Status
Status
H
J
K
0V 7A15
J17
C
B
B
0V 7A15
A
C
B
E
H
J4
J6
C
L
J
K
BJ5
A
C
B
E
H
J1
J3
C
L
J
K
BJ2
Stow Pin Status
Safety Sw Status
0V for Safety Sw
0V for Hatch
Hatch Status
Hand Crank Status
0V for Hand Crank
Interlock 24V
Interlock 0V
Interlock Status
A1A7-E1/L1
A1A8-E2/L2
A1A6 N
A1A6-L
A1A11-E2/L2
A1A2-E1/L1
A1A5-N
A2A10-L
A2A10-N
A2A4-E2/L2
Transient ProtectionU31A12
A
C
B
E
H
J2
J6
C
L
J
K
BJ5
A2A1-E1/L1
A2A2-E2/L2
A2A9-N
A2A9-L
A2A5-E2/L2
A1A8-E2/L2
A1A11-N
A2A10-L
A2A10-N
A3A9-E2/L2
3
14
22
9
J112
13J8
5
4
6
5
J12
W1601B
W1802B
W1701B
W1601C
W1802C
W1701C
W1601A
W1802A
W1701A
Pedestal InterfaceU16
4
6
5
J827
28
28
J9
J2
To K7 Drive Enable
10
TP1 TP2W2001
W2003
FMAC InterfaceU7A15
13J10
5
27
28
28
J5
J7
3
14
22
9
J512 Stow Pin Status
Safety Sw Status
0V for Safety Sw
0V for Hatch
Hatch Status
Hand Crank Status
0V for Hand Crank
Interlock 24V
Interlock 0V
Interlock Status
Sh 1328
ANTENNA Polarizer/OB Lights Sheet 14 of 18
Pedestal Local Control PanelU34
AntennaRadar Shelter
FMAC InterfaceU7A15
AC PowerJunction Box
Linear Polarization
Circular Polarization
Polarizer HTR Line
Polarizer HTR Return
Polarization Command Return
AC Ground
Lights 120VAC
Lights 220/240VAC RTN
Spare
1
2
3
4
5
6
7
8
9
Rotary JointConnector C3
A
B
C
D
E
F
G
H
I
C
CR3
L
CR4
Line Voltage
Linear Command
Circular Command
K
J17L
24V 7A15F2
24V 7A15F2
S4
W0049A
B
E
F
G
H
Not Used
SEEDETAIL
Line
0V 7A15
StatusJ16
AC-Surge Prot240VAC
LNE
LNE
AC-Surge Prot240VAC
LNE
LNE
ObstructionLights
Motor
K1
NOTES:Drawing shown in CircularK1 energized in Circular
S3 S2S4
LB Linear Status
LB Circular Status
S1
220V Motor Drive
Return
Motor
High B
eamS3 S2S4
HB Linear Status
HB Circular Status
S1
220V Motor Drive
Return
Power/Control Box
Low Beam Polarizer
High Beam Polarizer
LB Circular Status
LB Linear Status
HB Circular Status
HB Linear Status
Polarizer Status ReturnN
K
L
H
J
CA5
6
8
9
10
7
TB1
A
B
E
D
CA3
Rotary JointConnector C2
N
K
L
H
J
TB17
J17f
f
TB116
TB14
TB311
TB311
N
K
L
H
J
J3TB321
E
J
K
T
R
P
M
0V 7A15
W0043 AC PowerLine
NeutralGround
Ground TB11
TB11/2/BB
TB2C
Transient Protection Panel
U31A12A1
Neutral
DP-4
CB-8X-Encoder
J6W1701B W1701CW1701A
Pedestal InterfaceU16
W2001K
L
f
From U
34
Linear Command
Circular Command
24V 7A15F2
J3K
L
f
A2A7-E1/L1
A2A8-E2/L2
A2A11-LF2
A2A13-E1/L1
A3A1-E2/L2
A3A11-L
J6K
L
f
J1213
14
1
J813
14
1
J915
23
29
J515
23
29
Transient ProtectionU34A1
J4
A1A9-E2/L2
Transient ProtectionU31A12
W1601BW1601C
W1601A J5
E
J
K
T
R
P
M LB Circular Status
LB Linear Status
HB Circular Status
HB Linear Status
Pol Status Return
0V 7A15
OB Light StatusFrom
U34
J2
E
J
K
T
R
P
M
A1A6-N
A1A6-L
A2A3-E2/L2
A2A2-E2/L2
A2A1-E1/L1
A1A11-E1/L1
J5
E
J
K
T
R
P
M
J11
5
22
9
20
18
17
15
A2A3-E2/L2
A2A9-N
A2A9-L
A2A8-E2/L2
A2A7-E2/L2
A2A6-E1/L1
A2A5-E1/L1
J51
5
22
9
20
18
17
15
Low B
eam
120VAC
Detail of LED OB Light Circuitry
AC CurrentMonitor
Obstruction LightFMAC Alarm
120 VAC
+
-
ControlTransformer
2:1+
-
40 watt
240VAC 120VAC3A
J1
A
B
E
F
G
H
W1701C
Go To
U34A
1
W1701C
W1601C
Go To U
34A1
Mezzanine Room
Go To
U34A
1
Circ PowerLin Power
Circ PowerLin Power
FAN OUTRELAY
+24V0V
Polarizer Command
K3
PLCP CB12 Amp
-
K1 Relay LocatedIn PLCP
Obstruction Light Out Alarm to FMAC
C NO
G
H
E
J
CB2
Added Circuit BreakerCB2
A BK17
TB121
Detail of INCANDESCENTOB Light Circuitry
ORDETAIL
E
J
G
HTO OB LightsC
B1
CB
2
ANTENNA Az Enc & Wx Beam Sw Sheet 15 of 18
Radar Shelter
CommonEquipment
CabinetU7
Beam Sw Control
Beam Sw Control
Beam Sw Status
Beam Sw Satus
Weather Hi/LO
Rotary JointConnector C2
W0043 AC PowerLine
NeutralGround
TB1 1/2/BBTB2C
Transient Protection Panel
U31A12A1DP-4
CB-8X-Encoder
W1701BW1701A
Pedestal InterfaceU16
W2003
J12
J8J2
Transient ProtectionU34A1
A1A7-E2/L2
Transient ProtectionU31A12
W1601BJ5A
D
G
H
J2
A1A8-E1/L1
A1A10-E2/L2
J5
A3A3-E2/L2
A3A3-E1/L1
DP-5
CB-8Y-Encoder
W0044 AC PowerLine
NeutralGround
TB1 3/4/BBTB2C
Power/Control Box
J150Ω
J2
J4
J3
TVS
SCA
X3
3,6,9
2
1
4
5
CA5
DC-Surge Prot13.8VDC
+-E
+-E
DC-Surge Prot110VDC
+-E
+-E
-70V
+5V
+5/-70V Return
A
B
C
D
E
CA4
Data Prot+/-20VDC
+-
+-
IS-SPDDL
RS-422
A
B
C
Rotary JointConnector C1
-70VDC
+5VDC
+5/-70V Return
Rotary JointChannel 3
X Y
PS Status
PS Status
X Encoder Data5VDC
J3
A
B
CS3
PS3+5VDC
Wx Bm Sw
PS4-70VDC
Wx Bm Sw
292622
282523
GNL
LNG
J7
A
B
J6
A
B
PS1+5VDC
Encoder X
PS2+5VDC
Encoder Y
S1
S2282522
LNG
741
LNG
+5VDC PS Status
-70VDC PS Status
Enc X PS Status
Enc Y PS Status
TB1
TVS
S CA
X1
TVS
S CA
X2
Pin D
iodeW
x Beam
Sw
itch
U39A1Wind Monitor
J8C
D
J4C
D
J8C
D
P/O TransientProtection
U35A7
A11E2
A11E1
Coax toW/G
Transition
W/G to Coax
Transition
J17V
W
W0044 A
C P
ower
W0043
W0044
J16H
J16G
J16A
J16D
J6V
W
J3A3A10-E2/L2
A3A10-E1/L1
V
W
A
D
G
H A1A10-E1/L1
P/O U35A7
A1-E2
J5A
B
C
D
J1
A1-E1
A2-E2
A2-E1
A
B
C
D
A3-J6J2
A3+
A4-
A4+
A
B
C
L
J
I
G
D
A
B
C
L
J
I
G
DJ7J3
A
B
C
L
J
I
G
D
X Encoder A Count -
X Encoder A Count +
X Encoder ARP -
X Encoder ARP +
X Ender B Count -
X Encoder B Count +
+5VDC
5VDC Return
Y Encoder A Count -
Y Encoder A Count +
Y Encoder ARP -
Y Encoder ARP +
Y Ender B Count -
Y Encoder B Count +
+5VDC
5VDC Return
A5-
A5+
A7-
A7+
A8-
A8+
A9-
A9+
A
D
G
H
J6V
W
J1A
B
C
D
J3A
B
C
L
J
I
J4A
B
C
L
J
I
J73
2
1
4
J99
1
3
11
10
2
J1012
4
6
14
13
5
W0701B
W9601B
W9602B W9602C
W9601C
W0701C
J1229
30
29
30
7
26
7
26
J7
J73
2
1
4
J239
1
3
11
10
2
J2412
4
6
14
13
5
W0701A
W9611
W9612
J111
4
7
8
J511
4
7
8
W1601BA2A1-E2/L2
A2A2-E1/L1
A2A4-E2/L2
A2A4-E1/L1
A1A13-E2/L2
A1A12+
A1A12-
A1A13-E1/L1
A1A6-E2/L2
A1A4-E1/L1
A1A4-E2/L2
A1A5-E1/L1
A1A5-E2/L2
A1A6-E1/L1
A1A3-E2/L2
A1A1-E1/L1
A1A1-E2/L2
A1A2-E1/L1
A1A2-E2/L2
A1A3-E1/L1
Low Beam
High Beam
To ADU A/B
A14
A15
X Encoder A Count -
X Encoder A Count +
X Encoder ARP -
X Encoder ARP +
X Ender B Count -
X Encoder B Count +
Y Encoder A Count -
Y Encoder A Count +
Y Encoder ARP -
Y Encoder ARP +
Y Ender B Count -
Y Encoder B Count +
Beam Sw Control +
Beam Sw Control -
Beam Sw Status +
Beam Sw Satus -
Beam Sw Control +
Beam Sw Control -
Beam Sw Status +
Beam Sw Satus -
W00
43W
0044
Wx H
i/LoTo R
EX
W1701C
W1601C
Pedestal Local Control Panel U34
Encoders
TB1-3 +
TB1-4 -
Mezzanine Room/Antenna
To U35A7 W9601/2BPins G & D
A
B
C
L
J
I
G
D
+5VDC
+5VDC
5V Return
5V Return
A6+
A6-
A10+
A10-
Y Encoder Data5VDC
Kohl
er E
/G C
ontro
l Pan
el
Cite
l Bas
e 1
Loca
ted
in E
ngin
e G
ener
ator
She
lter
10 Relay Kit
K1
K9
K8
K7
K6
K5
K4
K3
K2
K10
Overspeed
Overcrank
High EngTemp
Low OilPres
Low WaterTemp
AuxFault
E/G 1 SysReady
Pre-AlmHigh Temp
Pre-almLow Oil Pres
EmergStop
39 Major Alarm
Sys Ready
Minor Alarm&
BatteryCharger
Telephone
FireAlarmFire
AlarmPull
SmokeDetector
HeatDetector
EG DoorClosed
EG Running
EG Remote Start and Normal Stop
43
41
40
30
28
35
38
36
12
56
34
12
EG Start
Transfer Switch on EG
Transfer Switch on Commercial
TB-2 3&4
CR-8Comm
CR-6NC
CR6Comm
CR-8NC
Day Tank Level Not Low
Day Tank Not Leaking
LV
CM
HV
CM = Charger MalfunctionLV = Low VoltageHV = High Voltage
To MinorTrouble Alarm
47
1A1
Emergency Stop
Cite
l Bas
e 2
Loca
ted
in R
adar
She
lter
NOTE:Common Connections between CB1 and CB2 are shared for some connections.AT CB1: Pins C R11,9,8,7,5,4,1 are tied together.AT CB1: Pins C R3,2 are tied together
14
12
13
30
29
3839
27
58
2331
25
26
5756
24
1115
Site
Gat
e C
onta
cts
Site Gate
4047W7201
ShelterDoors
21
1
20
FMA
C In
terf
ace
Pane
l P/O
U7A
15 J
54 In
put M
odul
es
8
7
20
5
1
3
4
2
18
W7205
J36 FMAC AJ46 FMAC B
P1
E/G #1 CMD COMMON
SHIELD
E/G #1 EMERGENCY STOP
13
6
7
2013
W41
BLACK
BROWN
ORANGE
A12TB1
COM
B-1
B-2
11
13
14E/G #1 RUN/STOP
6
11
7
6
20
7
FMA
C A
/B In
terf
ace
Pane
l P/O
U7A
15 J
94/P
18 In
put M
odul
es
8
7
20
5
1
3
4
2EG Running
Major Trouble
Minor Trouble
System Ready
Transfer Switch on EG
Transfer Switch on Commercial
Fuel Tank Not Low
Fuel Tank Not Leaking
9 Status Common24V FIPF11
B8
A1
B7
FMA
C A
/B In
put M
odul
es F
MA
C A
P4,
FM
AC
B P
12
A8
A7
B7
A5
A1
A3
A4
A2
B5
A9
W6401 Radar Shelter Doors
W6401 EG No Fire
W6401 EG No Smoke
W6401 EG Door Closed
Status CommonTo Pin 15
FMAC JBOX
21
1
20
18
22 22Common B9
To A
7CN
1To
A6C
N2
W7206
Engine Generator Shelter
Day
Ta
nk
Koh
ler
Batte
ryC
harg
er
Koh
ler
Tran
sfer
S
witc
h
TelephoneService
B T1B R1
B T9B R9
B T10B R10
B T3B R3
B T7B R7
D T3D R3
D T1D R1
B T12B R12
D T8D R8
D T6D R6
D T7D R7
D T2D R2
D T11D R11
D T4D R4
D T5D R5
D T9D R9
D T4D R4
A T1A R1
A T3A R3
A T7A R7
A T9A R9
A T10A R10
A T12A R12
C T1
C T5
C T4
C T11C R11
C T2
D T9
C T6C R6
C T8
C T9
C T3C R3
A T1A R1
A T3A R3
A T7A R7
A T9A R9
A T10A R10
A T12A R12
C T1
C T3C R3
C T5
C T4
C T11C R11
C T2
C T7
C T6C R6
C T8
C T9
C T12C R12
B T1B R1
B T3B R3
B T7B R7
B T9B R9
B T10B R10
B T12B R12
D T1
D T3D R3
D T5
D T4
D T11D R11
D T2
D T7
D T6D R6
D T8
C T9
D T12D R12
B T2B R2
A T2A R2
A T2A R2
B T2B R2
TelephoneService
SparePhone
WIR
ES IN
CO
ND
UIT
Fire
Ala
rmC
ontr
ol P
anel
K3-NC
K2-NC
W7206
W7206
K1Located in CB1
Engine Generator Sheet 16 of 18
CMU Radar Shelter
FMAC Interface Panel P/O U7A15 J19
Output Modules
W7201
W7205
FMAC JBU31A20
FMAC Int PanelU7A15 J55
FMAC A/B Int Panel P/O U7A15 J95/P17
FMAC A/B IP ModulesA P5/B P13
T1 T1R1 R1T2 T2R2 R2
T15 T15R15 R15T16 T16R16 R16
T13 T13R13 R13T14 T14R14 R14
T11 T11R11 R11T12 T12R12 R12
T9 T9R1 R9T10 T10R10 R10
T7 T7R7 R7T8 T8R8 R8
T5 T5R5 R5T6 T6R6 R6
T3 T3R3 R3T4 T4R4 R4
A B
T1 T1R1 R1T2 T2R2 R2
T11 T11R11 R11T12 T12R12 R12
T9 T9R9 R9T10 T10R10 R10
T7 T7R7 R7T8 T8R8 R8
T5 T5R5 R5T6 T6R6 R6
T3 T3R3 R3T4 T4R4 R4
C D
Citel Base 1 – EG ShelterCitel Base 2 – Radar Shelter
W6401
E280T
E280-24V
E280-24V
E280-24VNot in DoD
E280-24VNot in DoD
E280-24V
E280-24V
E280-24V
E280-24V
E280-24V
E280-24V
E280-24V
E280-24V
E280-24V
Telephone
Spare Telephone
Fire Strobe From
Fire Strobe To
Fire Horn From
Fire Horn To
Fire Pull From
Fire Pull To
Smoke Detector
Heat Detector
Door Closed
EG Running
EG Start/Stop
Emergency Stop
EG Alarm (Minor)
EG Alarm (Major)
On Commercial
On EG
Tank Level Low
Tank Leaking
System Ready
FireHorn
B T8B R8
A T8A R8
A T8A R8
B T8B R8
See Sheet 17 for loop
X
X
Removed withSSM 078
Pedestal RoomDoor Closed
Smoke AlarmZone 3
Fire Alarm PullStation Zone 7
Heat DetectorZone 4
Pedestal Room
B T1B R1
B T5B R5
B T3B R3
B T8B R8
A T1A R1
A T3A R3
A T8A R8
A T5A R5
A T1A R1
A T3A R3
A T8A R8
A T5A R5
B T1B R1
B T3B R3
B T8B R8
B T5B R5
Fire
Ala
rmC
ontr
ol P
anel
Citel Base 3,4,5,6 Sheet 17 of 18
CMU Radar Shelter
FMAC JBU31A20
FMAC Int PanelU7A15 J95/P17
Door
Fire Horn B T6B T6
A T6A R6
A T6A R6
B T6B R6
Fire Strobe B T4B R4
A T4A R4
A T4A R4
B T4B R4
T1 T1R1 R1T2 T2R2 R2
T15 T15R15 R15T16 T16R16 R16
T13 T13R13 R13T14 T14R14 R14
T11 T11R11 R11T12 T12R12 R12
T9 T9R1 R9T10 T10R10 R10
T7 T7R7 R7T8 T8R8 R8
T5 T5R5 R5T6 T6R6 R6
T3 T3R3 R3T4 T4R4 R4
A B
Citel Base 6 – Radar ShelterTelco Connections
T23 T23R23 R23T24 T24R24 R24
T21 T21R21 R21T22 T22R22 R22
T19 T19R19 R19T20 T20R20 R20
T17 T17R17 R17T18 T18R18 R18
T25 T25R25 R25
E280T
E280T
E280T
E280T
E280T
E280T
E280T
E280T
E280T
E280T
E280T
E280T
E280T
EG Shelter
6.8k .5W
10k .5W
10k .5W
6.8k .5W
6.8k .5W
SmokeDetector
Heat Detector
Pull
Horn
Pull
Horn
Pull Pull
Horn
Cite
l Bas
e 5
Cite
l Bas
e 4
Cite
l Bas
e 2
Cite
l Bas
e 1
B T8B R8
A T8A R8
B T4B R4
A T4A R4
B T6B R6
A T6A R6
A T8A R8
B T8B R8
A T4A R4
B T4B R4
A T6A R6
B T6B R6
B T7B R7
A T7A R7
B T3B R3
A T3A R3
B T5B R5
A T5A R5
A T7A R7
B T7B R7
A T3A R3
B T3B R3
A T5A R5
B T5B R5
Telephone B T9B R9
A T9A R9
A T9A R9
B T9B R9
To CB6
Ped
esta
l Roo
m-N
o Fi
re K
1 N
/C
Ped
esta
l Roo
m-N
o S
mok
e K
2 N
/C
7108
9T1 T1R1 R1T2 T2R2 R2
T11 T11R11 R11T12 T12R12 R12
T9 T9R9 R9T10 T10R10 R10
T7 T7R7 R7T8 T8R8 R8
T5 T5R5 R5T6 T6R6 R6
T3 T3R3 R3T4 T4R4 R4
A B
Citel Base 4 – Radar ShelterCitel Base 5 – Pedestal Room
Door Closed
Fire Strobe
Smoke Alarm
Heat Sensor
Fire Horn
Fire Pull Station
Telephone
Spare
Spare
E280-24V
E280-24V
E280-24V
E280-24V
E280T
E280-24VNot in DoD
T1 T1R1 R1T2 T2R2 R2
T9 T9R1 R9T10 T10R10 R10
T7 T7R7 R7T8 T8R8 R8
T5 T5R5 R5T6 T6R6 R6
T3 T3R3 R3T4 T4R4 R4
A B
Citel Base 3 – Radar ShelterEnvironmental Control Unit (ECU)
E280-24V
E280-24V
E280-24V
E280-24V
E280AV-110 (120V)
ECU TB1-11ECU TB1-12ECU TB1-13ECU TB1-14
ECU TB1-16
ECU TB1-18
ECU TB1-19ECU TB1-20ECU TB1-21
ECU TB1-23
ECU TB3-1ECU TB3-2ECU TB3-3ECU TB3-4
5
7
8
FMAC A/BA7CN1 P5
Input Module
A5
A7
A8
Not In DoD
24V PS A7PS1
24V PS B7PS2
24VD
C
F2 1A
F3 1A
F4 1A
F5 1A
F6 1A
F7 1A
F8 1A
F9 1A
F10 1A
F11 3A
F12 3A
F1 1AU16 K7
Motor A/B Run
Hatch Safety Switch Hand Crank Stow Pin
*U16 K5Motor A
Tx Enable *U16 K6Motor B
Tx Enable
A Run Status
B Run Status
U34 K4Sump Heater
RelaySump Thermostat
From Motor Controllers
* Contacts on K5&6 enable MSSR and PSR TransmitterContacts are in parallel so either relay can keep Tx operating
0V RTN
* Contacts on K4 supply 3 phase power to sump & GB heaters
0V RTN
Compressor/Dehydrator Status & WG Pressure
Spare
To FMAC A Modules A9 & A10 for A/D conversion of Wind Speed, Motor Amps, and LP/SP forward and reverse power from TCMM A RF Monitor
To FMAC B Modules A9 & A10 for A/D conversion of Wind Speed, Motor Amps, and LP/SP forward and reverse power from TCMM B RF Monitor
To Fire Alarm System
F13 1AGoes to U16 J2 Pin 8, Not Used
FMAC A&B Modules A5, A7, and A8
7A15J10 Pin 18 on W1802, to U31A12 J8 Not Used
220VACJunction Box AUnit 7
Interlock Complete
DP4 CB715A
220VACJunction Box BUnit 7
DP5 CB715A
FMAC A&B Modules A6, A7 and A8
7A15 Fuse Panel 24V distribution Sheet 18 of 18
GB A Oil Level
GB B Oil Level
Sump Oil Level
Ped Low Temp
PLCP U34
0V RTN
0V RTN
0V RTN
0V RTNA Contact
B Contact
D Contact
K5
Oil Level Transition
Module