PS Automation

2
Approx. weight: 7 kg without accessories Power Supply [V] Nominal Current [A] Maximum Current [A] Power Consumption )² [W] Power Supply [V] Nominal Current [A] max. Current [A] Power Consumption )² [W] Ambient Temperature [°C] Motor Protection Overvoltage category Break away force Duty Cycle IEC 600341,8 Set value and Feedback Binary control Valve Positioner Function Automatic Startup Internal Fault Monitoring Diagnostics Function Communication Interface Cable Glands ) 1 = Permissible average torque for a travel of 90° )² = at nominal force )³ = at 400 V 3 phases and 50 Hz ) 4 = Data can change depending on accessories ) 5= at switching torque, data can change depending on accessories Standard Equipment Standard S2 30 min S4 50% ED @ 25°C 2 threaded holes ISO M20 x 1,5 (cable glands are not included) deadband adjustable from 0.5 .. 5%, shutoff minimum at torque switching Recognizing the end position(s) and autoscaling set and feedback values current 0 (4)… 20 mA, voltage 0 (2)… 10 V adjustable, splitrange operation possible for parametrisation and diagnosis with USB data cable and software PSCS Torque, set value, temperature, power supply, deviation of end positions, adjustable actions and signalisation 24 V for ON/OFF control (min. duration of pulse 1s) adjustable up to + 30% nominal force Stores number of motor starts, motor and total running time. Rolling data storage of set value, feedback value, torque, temperature and status Description 320…575 VAC 3~ 3.0(AC) / 1.9(DC) 2.3(AC) / 1.4(DC) 1 0.5 0.5 )³ 1.3 230 VAC 1~ 115 VAC 1~ 24 VAC/DC 0.65 0.36 )³ II Intelligent QuarterTurn Actuator PSQ102 AMS1x Positioner integrated 65 130 Nm Switching torque Modulating torque max. 65 Nm ) 1 Operating Time/90° 36 72 s (adjustable) Enclosure IP67 acc. to EN 60529 PSQ102 AMS11 Operating Time/90° 9 18 s (adjustable) 0.31 9s 72 s Operating Time/90° Flange F05 + F07 Modulating Actuator Class C acc. EN 157142 PSQ102 AMS12 115 VAC 1~ 0.2 )³ 41 0.48 0.62 41 0.24 0.2 )³ 38(AC) / 34(DC) 50 )³ 230 VAC 1~ 24 VAC/DC 20 to +60 °C electronic motor current monitoring with safety cutoff 98 100 320…575 VAC 3~ 6.2(AC) / 3.9(DC) 95 )³ 95(AC) / 72(DC) 4.8(AC) /3.0(DC) 161 263 86 79 263 216 158 196 PS Automation GmbH TD_AMS1x_PSQ102_ENG_07.05.2015 _ Page 1 of 2__

description

Td Ams1x Psq102 Eng 0

Transcript of PS Automation

  • Approx.weight:7kgwithoutaccessories

    PowerSupply [V]NominalCurrent [A]MaximumCurrent [A]PowerConsumption) [W]

    PowerSupply [V]NominalCurrent [A]max.Current [A]PowerConsumption) [W]

    AmbientTemperature [C]MotorProtectionOvervoltagecategoryBreakawayforceDutyCycle IEC600341,8SetvalueandFeedbackBinarycontrolValvePositionerFunctionAutomaticStartupInternalFaultMonitoring

    DiagnosticsFunctionCommunicationInterfaceCableGlands)1=Permissibleaveragetorqueforatravelof90)=atnominalforce)=at400V3phasesand50Hz)4=Datacanchangedependingonaccessories)5=atswitchingtorque,datacanchangedependingonaccessories

    Stan

    dard

    Eq

    uipm

    ent

    Standard

    S230minS450%ED@25C

    2threadedholesISOM20x1,5(cableglandsarenotincluded)

    deadbandadjustablefrom0.5..5%,shutoffminimumattorqueswitchingRecognizingtheendposition(s)andautoscalingsetandfeedbackvalues

    current0(4)20mA,voltage0(2)10Vadjustable,splitrangeoperationpossible

    forparametrisationanddiagnosiswithUSBdatacableandsoftwarePSCS

    Torque,setvalue,temperature,powersupply,deviationofendpositions,adjustableactionsandsignalisation

    24VforON/OFFcontrol(min.durationofpulse1s)

    adjustableupto+30%nominalforce

    Storesnumberofmotorstarts,motorandtotalrunningtime.Rollingdatastorageofsetvalue,feedbackvalue,torque,temperatureandstatus

    Description

    320575VAC3~

    3.0(AC)/1.9(DC)2.3(AC)/1.4(DC)

    10.5

    0.5)1.3

    230VAC1~ 115VAC1~ 24VAC/DC

    0.65

    0.36)

    II

    IntelligentQuarterTurnActuator PSQ102AMS1xPositionerintegrated65130Nm

    SwitchingtorqueModulatingtorquemax.65Nm)1

    OperatingTime/90 3672s(adjustable)

    EnclosureIP67acc.toEN60529

    PSQ102

    AMS11

    OperatingTime/90 918s(adjustable)

    0.31

    9s72sOperatingTime/90

    FlangeF05+F07

    ModulatingActuatorClassC

    acc.EN157142

    PSQ102

    AMS12

    115VAC1~0.2)

    41

    0.48

    0.62

    41

    0.24

    0.2)38(AC)/34(DC) 50)

    230VAC1~ 24VAC/DC

    20to+60Celectronicmotorcurrentmonitoringwithsafetycutoff

    98100

    320575VAC3~

    6.2(AC)/3.9(DC)95)95(AC)/72(DC)

    4.8(AC)/3.0(DC)

    161

    263

    86

    79

    263

    216

    158

    196

    PSAutomationGmbH TD_AMS1x_PSQ102_ENG_07.05.2015_

    Page1of2__

    export14Highlight

    export14Highlight

    export14Highlight

    export14Highlight

    export14Highlight

    export14Highlight

    export14Highlight

  • ElectricalWiringDiagram

    AvailableDriveBushes

    F05 F07 D2 38 38 H 44 44 H1 35 35

    Pleasecheckthedrivebushesdatasheetfortheavailablesizes! M M6 M8Othercustomizeddrivebushesonrequest! B 12 16

    2WE

    Add'lPositionSwitches 2WEGold

    PSCP

    LocalControl* PSC.2

    RemoteLocalControlDataCable PSCSUSB

    FaultIndicationRelay* FIR

    FSP

    CorrosionProtection K2IP68

    HR

    TerminalBox**notretrofittableFormoreinformationandaccessories,pleasevisitourwebsitewww.psautomation.com!Subjecttochanges!

    HeatingResistor Heatingresistortopreventcondensation

    MountingPosition

    SquareXorY(45turned) DoubleD Keyway

    Accessories/

    Optio

    ns

    TechnicalData

    PlugandsocketinanIP68box

    potentialfreeopeningcontactprovidesafreelydefinablecollectivefaultsignal

    USBdatacableenablesthecommunicationbetweentheactuatorandaPCbyusingthesoftwarePSCS

    mountingseparatelyfromtheactuator(incl.10mconnectioncable)

    Illuminateddisplaytoshowtheactuatorstatusandlockableselectortoswitchbetweenmodes:automatic,manualprocessON/OFF,STOPandparametermenu.Controlbuttonsformanualmovement,menuoperationandadjustmentofparameters,displayofdiagnosticinformation

    Potentialfreeadditionalpositionswitcheswithgoldcontacts(0.1mA100mAswitchingcurrent)

    PSQ102AMS1x

    IncreasedenclosureIP68

    Signalporttodrivetoa"safetyposition",selectablefailsafeposition,standard24VIncreasedcorrosionprotectionincl.heatingresistor

    FailSafePort*

    Add'lPositionSwitches

    FailSafe* Emergencypowersupplybasedonsupercapacitors,safetypositionOPEN,CLOSEDorfreedefinedposition

    FieldbusInterface*Digitaltransmissionofnominalandactualvaluepermillorpercent,reportofmonitoringanddiagnosticdatausingProfibusDP(PSPDP)orCANOpen(PSCA)interfaces,additionalinterfacesavailableonrequest

    BinaryInputs115230VAC* Binaryinputvoltageof115230VACforON/OFFcontrol

    Potentialfreeadditionalpositionswitcheswithsilvercontacts(0.1A5Aswitchingcurrent)

    X Y

    45

    SW+0,1

    E-0,5

    Z SW+0,1 E

    +0,5

    90

    A

    B

    C

    D

    A

    bJ9

    T+0

    , 1

    dH8

    HB

    MD2

    H1

    PSAutomationGmbH TD_AMS1x_PSQ102_ENG_07.05.2015_____

    Page2of2__

    export14Highlight

    export14Highlight

    export14Highlight

    export14Highlight

    export14Highlight