Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe...

29
Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008

description

High Rise Building: – 6 Floors or more Dedicated Underground Area: – Automatic Transfer – Pad mount equipment at grade – Two Service Voltages Overhead / Underground Area: – Pad mount equipment at grade – Two Service Voltages

Transcript of Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe...

Page 1: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.

Providing Service toHigh-rise Condominiums

PresenterCharles L. Kahanek

SWEDE ConferenceHorseshoe Bay, TexasMay 2008

Page 2: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.

Houston High-rise Condominiums

Page 3: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.

Standard Service

• High Rise Building:– 6 Floors or more

• Dedicated Underground Area:– Automatic Transfer– Pad mount equipment at grade– Two Service Voltages

• Overhead / Underground Area:– Pad mount equipment at grade– Two Service Voltages

Page 4: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 5: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 6: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 7: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 8: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 9: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 10: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 11: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 12: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 13: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 14: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 15: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 16: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 17: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.

Modular Metering

• General Requirements:– Single Phase Meters Only– 2, 3, 4 or 5 high meter centers, 6 high approval based on overall height– All openings must have meter installed – no blanks– 120/240 or 120/208– Ring Type Enclosures– No Bypass Switches– Must be UL Approved

Page 18: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 19: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 20: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 21: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 22: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 23: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 24: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 25: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 26: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.
Page 27: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.

Providing Service toHigh-rise Condominiums

Continues to Change

Page 28: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.

MULTI-USE FACILITIES

• CONDOMINIUMS– Penthouses– Spa/Gym– Pool

• HOTEL– Banquet/Meeting Rooms– Food Service

• RETAIL• PARKING GARAGE

Page 29: Providing Service to High-rise Condominiums Presenter Charles L. Kahanek SWEDE Conference Horseshoe Bay, Texas May 2008.

Questions