PROSTHETIC PROCEDURE MANUAL AR SYSTEM
description
Transcript of PROSTHETIC PROCEDURE MANUAL AR SYSTEM
PROSTHETIC PROCEDURE MANUALAR SYSTEM
CEMENTED RESTORATION
Impression Copings
Set Screw
Pick-up
Transfer
Implant Analog
CementedAbutment
AngledAbutment
IMPRESSION COPINGSImplant Level – Pick-up
• Implant level impression, pick-up impression coping (open tray technique)• Impression coping is packaged with corresponding guide pin• Use 1.2mm Hex driver to assemble/ disassemble
Engaging
Guide Pin
1.2mm Hex Driver
IMPRESSION COPINGSImplant Level – Transfer
• Implant level impression, transfer impression coping (closed tray technique)• Impression coping is packaged with corresponding guide pin• Use 1.2mm Hex driver to assemble/ disassemble
Engaging
Guide Pin
1.2mm Hex Driver
IMPLANT ANALOG
CEMENTED ABUTMENT
Fastening torque 30 Ncm
HEIGHT
CUFF
DIAMETER
Engaging
1.2mm Hex Driver
ANGLED ABUTMENT
• Options of 15 degrees and 25 degrees• Angled Abutments are packaged alongside corresponding set screw• Fastening torque 30 Ncm
HEIGHT
CUFF
DIAMETER
Engaging
1.2mm Hex Driver
SET SCREW
• Cemented Abutment screw is 10mm long• Angled Abutments screw is 8mm long• Set screws are packaged along with corresponding abutment
LENGTH
DIAMETER
CLINICAL PROCESSFixing Impression Copings (1/3)
• View of patient’s mouth
CLINICAL PROCESSFixing Impression Copings (2/3)
• Remove healing abutment / cover screw with 1.2mm Hex Driver
• Insert impression coping inside corresponding implant connection
CLINICAL PROCESSFixing Impression Copings (3/3)
• Fasten impression coping with corresponding guide pin• Tighten guide pin with 1.2mm hex driver
CLINICAL PROCESSTaking The Impression (1/6)
• Apply the light impression material on corresponding site of oral cavity
CLINICAL PROCESSTaking The Impression (2/6)
• Pour the heavy impression material inside the impression tray
CLINICAL PROCESSTaking The Impression (3/6)
• Position tray for impression taking• Apply pressure until top part of guide pin appears• wait for impression material to set• Transfer impression copings will require prefabricated tray• Pick-up impression copings will require previously customized tray
CLINICAL PROCESSTaking The Impression (4/6)
• Remove guide pin
CLINICAL PROCESSTaking The Impression (5/6)
• Check tray for impression errors / success
CLINICAL PROCESSTaking The Impression (6/6)
• Replace healing abutment / cover screw in corresponding site
LABORATORY PROCESS1. Fixing Analogs & Making Artificial Gum (1/4)
• Fix analogs on corresponding impression coping
LABORATORY PROCESS1 - Fixing Analogs & Making Artificial Gum (2/4)
• Apply (Spray) separating product on impression areas
LABORATORY PROCESS1. Fixing Analogs & Making Artificial Gum (3/4)
• Apply artificial gum product on intervention area• Wait for product to dry
LABORATORY PROCESS1. Fixing Analogs & Making Artificial Gum (4/4)
• Trim gum
LABORATORY PROCESS2. Master Modeling (1/3)
• Prepare (mix) the stone
LABORATORY PROCESS2. Master Modeling (2/3)
• Pour the mixed stone inside the impression
LABORATORY PROCESS2. Master Modeling (3/3)
• Master model finishing work
LABORATORY PROCESS3. Abutment Milling (1/5)
• Fix the abutment to the analog
LABORATORY PROCESS3. Abutment Milling (2/5)
• Abutment Milling (Step 1)
LABORATORY PROCESS3. Abutment Milling (3/5)
• Abutment Milling (Step 2)
LABORATORY PROCESS3. Abutment Milling (4/5)
• Abutment Milling (Step 3)
LABORATORY PROCESS3. Abutment Milling (5/5)
• Post Milling
LABORATORY PROCESS4. Pattern Resin & Wax-Up (1/3)
LABORATORY PROCESS4. Pattern Resin & Wax-Up (2/3)
• Wax-up process (Steps 1 & 2)
LABORATORY PROCESS4. Pattern Resin & Wax-Up (3/3)
• Wax-up process (Steps 3 & 4)
LABORATORY PROCESS5. Sprewing (1/2)
• Sprewing (Step 1)
LABORATORY PROCESS5. Sprewing (2/2)
• Sprewing (Step 2)
LABORATORY PROCESS6. Investment (1/2)
• Investment (Step 1)
LABORATORY PROCESS6. Investment (2/2)
• Investment (Step 2)
• Burn out (Step 3)
LABORATORY PROCESS7. Casting
• Cast and extract cast structure
LABORATORY PROCESS8. Adaptation & Metal Trimming
• Check cast structure for adaptation on master model
LABORATORY PROCESS9. Finishing
LABORATORY PROCESS10. Transfer Jig (1/2)
• Make the transfer Jig
LABORATORY PROCESS10. Transfer Jig (2/2)
• Place the abutment(s) inside the oral cavity by using the transfer jig