Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80...
Transcript of Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80...
![Page 1: Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80 160 Elevated Pedestrian Path Tangent Street Connection Penberthy Rd George Bush Dr](https://reader035.fdocuments.in/reader035/viewer/2022070807/5f05c0c67e708231d4148837/html5/thumbnails/1.jpg)
UP
UP
U
P
U
P
UP
UP
U
P
U
P
dn
dn
dn
dn
dn
dn
Master Plan Proposal . Arch 605 . Sandra M Hernandez .
0 5 10 40 80 160
Elevated Pedestrian Path
Tangent Street Connection
Penberthy Rd
George B
ush D
r W
Luther S
t W
George Bush
Memorial Bridge
Bus Stop
Square
Food Truck and
Delivery
Access Ramp to
Parking Garage
Access Ramp to
Parking Garage
RadialLiving
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
![Page 2: Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80 160 Elevated Pedestrian Path Tangent Street Connection Penberthy Rd George Bush Dr](https://reader035.fdocuments.in/reader035/viewer/2022070807/5f05c0c67e708231d4148837/html5/thumbnails/2.jpg)
up
dn
up
dn
up
dn
u
p
d
n
up
dn
Up
dn
dn
Tangent Street Connection
Up
+ 100'
00"
+ 90' 01"
+ 100' 00"
+ 104' 00"
+ 100' 00"
Pedestrian Access to
Parking Garage
Pedstrian Ramp to
Parking Garage
Multiple Use
Outdoor Space
Media Lab
Library
Retail and
Commercial
Testing
Outdoor Plaza
Three Bedroom
Units
Vehicular Access
Ramp to Underground
Parking Garage
Pedestrian Bridge
Pedestrial Trial
Pedestrian Path
Pedestrial Trial
Elevated Pedestrian Path,
Direct Access to George
Bush Memorial Bridge
Medical
Clinic
Students
Affair
Dental
Clinic
Medical
Clinic
Police
Station
Outdoor
Plaza
Shaded Pedestrian Path
Multiple Use
Outdoor Space
Ground Level + 100' 00" . Arch 605 . Sandra M Hernandez .
0 5 10 40 80 160
RadialLiving
Retail and
Commercial
Three
Bedroom
Units
Two Bedroom Units
Retail and
Commercial
+ 100' 7"
+ 100' 7"
+ 100' 7"
A
A'
North West
Elevation View
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
![Page 3: Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80 160 Elevated Pedestrian Path Tangent Street Connection Penberthy Rd George Bush Dr](https://reader035.fdocuments.in/reader035/viewer/2022070807/5f05c0c67e708231d4148837/html5/thumbnails/3.jpg)
Tangent Street Connection
+ 100' 00"
+ 100' 00"
+ 114' 00"
Peatonal Bridge
Elevated Pedestrian Path,
Direct Access to George
Bush Memorial Bridge
Outdoor Plaza
up
dn
up
dn
up
dn
u
p
d
n
up
dn
dn
dn
Three Bedroom Units
+ 119' 10"
+ 119' 10"
Connection Bridge
Public Sitting
Second Level (Typical Plan) + 119' 10" . Arch 605 . Sandra M Hernandez .
RadialLiving
Intrados Units
Two Bedroom
Apartment
Extrados Units
Three Bedroom Apartment
Three Bedroom Units
Two Bedroom Units
Three Bedroom Units
Public Sitting
Connection Bridge
Connection Bridge
U
P
U
P
0 5 10 40 80 160
A
A'
See Wall
Section Detail
+ 119' 10"
Public Sitting
Connection Bridge
See Enlarge
Apartment Detail
Intrados Units
Two Bedroom
Apartment
North West
Elevation View
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
![Page 4: Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80 160 Elevated Pedestrian Path Tangent Street Connection Penberthy Rd George Bush Dr](https://reader035.fdocuments.in/reader035/viewer/2022070807/5f05c0c67e708231d4148837/html5/thumbnails/4.jpg)
up
dn
up
dn
up
dn
up
dn
u
p
d
n
dn
dn
Section A- A' Parking Level + 90' 01" (Typical Plan) . Arch 605 .
0 5 10 40 80 160
Tangent Street Connection
Mecanical
Room
Access Ramp to
Parking Garage
Mecanical
Room
Mecanical
Room
Mecanical
Room
+ 90' 01"
Pedestrian Access to
Ground Level
Pedestrian
Ramp Access to
Ground Level
Ground slopes away 5%6" per 10 Ft.
NanaWall Befolding door
Concrete Foundation Wall
Below Frostline
Deep Fundation
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
![Page 5: Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80 160 Elevated Pedestrian Path Tangent Street Connection Penberthy Rd George Bush Dr](https://reader035.fdocuments.in/reader035/viewer/2022070807/5f05c0c67e708231d4148837/html5/thumbnails/5.jpg)
Bituthene
1/2" Hydro-drainage Board
Reinforce Concrete Structural Wall
1" styro-foam Protection
Water Proof
System
Detail 2
Detail 1SCI Thermal BreakThe schock Isokorb Type CM for Concrete Balcony are high performancethermal insulators used between horizontal and vertical connections ofinternal and external elements to prevent thermal / cold bridging. Theyprovide a simple, economical and extremely effective solution to meetingPart L of the Building Requirements by way of reducing heat loss and therisk of internal condensation.
Slab Hidden Beam
Nana Wall BifoldingDoors
Ground slopes away 5%per 10 ft.
Concrete FundationWall
Below Frost Line
Deep Foundation
Ground Level + 100' 00"
Ground Level + 90' 01"
Ground Level + 80' 02"
Second Level + 119' 10"
Typical Level (139' 8")
Green Accessible Roof Level+ 159'6"
Double HeightCommercial/Retail
NanaWall
Coarse Gravel
Filter Fabric above andbelow drain pipe
Free drain backfill
Detail 2
Detail 1Top View
Front View
Low Profile Saddle Sill
Top Hung Head Jamb
Wall Section Detail
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
![Page 6: Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80 160 Elevated Pedestrian Path Tangent Street Connection Penberthy Rd George Bush Dr](https://reader035.fdocuments.in/reader035/viewer/2022070807/5f05c0c67e708231d4148837/html5/thumbnails/6.jpg)
A
C
B
D
E
F
G
I
H
2
3
4
1
A1
A2
A3
B1
B2
B3
C1
C2
C3
D1
E1
F1
D2
D3
E2
E3
F2
F3
H1
H2
H3
Symbology
Typical Structure Diagram(Typical Plan) . Arch 605 . Sandra M Hernandez .
0 5 10 40 80 160
RadialLiving
10" X 72" Slab Hidden Beam 47' Span
10" X 56" Slab Hidden Beam 41' Span
10" X 40" Slab Hidden Beam 28' Span
10" X 40" Slab Hidden Beam 29' Span
One way Slab 30' Span
One Way Beam and Slab
System
Description:
The post-tensioned structural system was selected afterconsider different pros and contras. One of the mostimportant factor to adopt this system is it versatility, itprovides the necessary flexibility to achieve thearchitectural curvilinear shape and form. It allow todesign highly precise, customizable forms. This versatilitymakes cast-in-place concrete appropriate for this large,architectural project.The thickness of the concrete slab is10". The one way slabs have spans of 30 ft. while thetypical beams range between of 20 to 47 ft. spans. Theirregular shape of the bays increase as they go farther ofthe centrifugal point.
Other Considerations:
• Strong and solid construction that providescomfortable shelter from typical weather, andminimizes property damage while protectingoccupants from extreme weather, like naturaldisasters.A major advantage of concreteconstruction for high-rise buildings is the material'sinherent properties of heaviness and mass, whichcreate lateral stiffness, or resistance to horizontalmovement.
• Low maintenance cost and low energy bills.Thetight-form building envelope minimize airinfiltration, simplify the addition of insulation, andprovide thermal mass for more consistenttemperatures and decreased energy usage. This isbeneficial from an environmental and cancontribute toward a building's greenness in manyrating systems and some codes.
• Smooth riding surface, by minimize joins.• Fire resistance ratings to meet code requirements.• Provides long, column-free spans easy to adapt to
the building's framing form and parkingrequirements.
Disadvantage:
• Initial cost• Labor requirements to cast-in-place concrete is
high. Builders must first construct forms for thewalls and then install the forms and mix theconcrete. Pouring the concrete and waiting toremove the forms all take time that extends thelength of a construction and results in more hourlypay for work crews.
Braced Frame Wall / Shear wall
Reinforced Concrete Hidden Beam Cross SectionDetail (flat slab beams)
Placed within the 10" slab thickness, to create acontinue smooth ceiling surface and increaseheight clearance. To maintain the beam's strength,the height size of the original beam was increasedtwice to the horizontal axial for example:Original beam height 36" now it is 10" X 72"
72"
10"
36"36"
O3
O2
O1
G3
G1
G2
10" PT One Way
10" PT One Way
10" PT One Way
10" PT One Way
2 Hr Fire UL V 465
System DescriptionSteel Stud
- 3 4" STRUCTO-CRETE® Base Layer- 3-1/2" Min. Steel Stud- 3-1/2" Glass Fiber Insulation- 58" SHEETROCK® FIRECODE® Core Type X Face Layer- 3 4" STRUCTO-CRETE® Face Layer at Top of Wall
Top View
Vertical section
Fire RatedInteriorWall System
STEEL STUD
FORMING MATERIAL
GYPSUM PANEL
TOP SET WOOD
STEEL STUD
RESILIENT CHANNEL (MAY BE
INVERTED TO EASE
ATTACHMENT TO BASE)
ACOUSTICAL SEALANT
GYPSUM PANEL
INSULATION
STEEL TRACK
SEALANT
CEILING ATTACHMENT
FLOOR ATTACHMENT
Acoustical Wall SystemBetween Apartment Units
17"
ConcreteColumn
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
![Page 7: Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80 160 Elevated Pedestrian Path Tangent Street Connection Penberthy Rd George Bush Dr](https://reader035.fdocuments.in/reader035/viewer/2022070807/5f05c0c67e708231d4148837/html5/thumbnails/7.jpg)
Interior Apartment . Arch 605 . Sandra M Hernandez .
RadialLiving
u
p
d
n
D3 E
48'
44'
48'
44'
10'
LivingRoom
DiningRoom Kitchen
MBath
MasterBedroom
Bedroom3
Laundry
Bedroom2
Laundry
Balcony
Balcony
FireStaircase
scenicTractionElevator
3Bedroom
Apartment
2Bedroom
Apartment
28'
BTR#2
Balcony
West Elevation
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
![Page 8: Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80 160 Elevated Pedestrian Path Tangent Street Connection Penberthy Rd George Bush Dr](https://reader035.fdocuments.in/reader035/viewer/2022070807/5f05c0c67e708231d4148837/html5/thumbnails/8.jpg)
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
d
n
d
n
u
p
d
n
u
p
d
n
d
n
d
n
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
u
p
d
n
Typical Roof LevelStarting at level +159' 06"
Horizontal Fire Evacuation Route
Vertical ADA Circulation
Horizontal Fire Evacuation Route, Alternative
Horizontal ADA Evacuation RouteHorizontal ADA Evacuation Route, Alternative
Vertical ADA Circulation
Point of Discharge of the BuildingPoint of Dischargeof the Building
Ground Level + 100' 00"
Typical Parking Level + 90' 01"
Typical Level + 109' 11"
Typical Roof LevelStarting at level +159' 06"
Point of Dischargeof the Building
Ground Level + 100' 00"
Typical Parking Level + 90' 01"
Typical Level + 109' 11"
Egress Direction
Accessible Restroom
ADA Egress FloorPlan/ Accesibility
Egress Floor Plans
36"
60" X 56"
5' 30" X 48"
0 5 10 40 80 160
0 5 10 30
Continuous handrail
Recessed fire resisting door-set with glazedvision panels and high and lower levels
Continuous handrail
Area of rescue and assistance
Fire extinguisher, handle800mm above floor,600mm from corner
5'
10'
C:\Users\Sandra.hernandez\AppData\Local\Microsoft\Windows\INetCache\Low\IE\W85MU5BO\20008706_woman_1[1].gif
Fire Protectedconnector bridge
Distance FP 180'
Distance FP 220'
Distance FP 138'
Distance FP 225'
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
![Page 9: Proposal Master Plan - mjobrienMaster Plan Proposal. Arch 605 . Sandra M Hernandez . 0 5 10 40 80 160 Elevated Pedestrian Path Tangent Street Connection Penberthy Rd George Bush Dr](https://reader035.fdocuments.in/reader035/viewer/2022070807/5f05c0c67e708231d4148837/html5/thumbnails/9.jpg)
2 Hr Fire UL V 465
System DescriptionSteel Stud
- 3 4" STRUCTO-CRETE® Base Layer- 3-1/2" Min. Steel Stud- 3-1/2" Glass Fiber Insulation- 58" SHEETROCK® FIRECODE® Core Type X Face Layer- 3 4" STRUCTO-CRETE® Face Layer at Top of Wall
6 1/2"
6 1/2"
Max 24" O.C.
Top View
Vertical section
Fire Rated InteriorWall System
STEEL STUD
FORMING MATERIAL
SEALANT
GYPSUM PANEL
GENERAL NOTES:
.Install with slotted holes over the framing members.
TOP SET
Gypsum panels type and thickness as required by required performance.
WOOD
STEEL STUD
RESILIENT CHANNEL (MAY BEINVERTED TO EASE ATTACHMENT TO BASE)
ACOUSTICAL SEALANT
GYPSUM PANEL
INSULATION
STEEL TRACKSEALANT
CEILING ATTACHMENT
FLOOR ATTACHMENT
Acoustical Wall SystemBetween Apartment Units
17"
ConcreteColumn
up dn
D3 E
48'
44'
48'
44'
10'
LivingRoom
DiningRoom
Kitchen
MBath
MasterBedroom
Bedroom 3
LaundryBedroom 2
Balcony
Balcony
FireStaircase
scenicTractionElevator
3 Bedroom Apartment
2 Bedroom Apartment
28'
BTR#2
Balcony
Fire resistant Walls
AcousticalWalls
Returning air air Supply air
Custodial Closet
Kitchen DiningRoom
Bathroom
Bedroom 1
Bedroom 2
Decentralized HVAC systems
Provide separate heating and cooling equipment for each unit, areless expensive to install initially, and to prevent stack effect. Alsodecentralized systems can be individually metered at the unit,whether gas-fired or run by electricity.
Elevator Machine Room:Located at the bottom level.
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT
PR
OD
UC
ED
B
Y A
N A
UT
OD
ES
K E
DU
CA
TIO
NA
L P
RO
DU
CT
PRODUCED BY AN AUTODESK EDUCATIONAL PRODUCT