PGc-1506SS_SoftView-SS 06/16 page 1 of 6 Philips Gardco SoftView LED parking garage luminaires feature edge lit technology, providing visual comfort with minimal glare to enhance the user experience. An added uplight feature reduces the cave effect for an increased sense of security. SoftView features two distribution options and four lumen packages, providing up to 8,614 lumens for an ideal garage lighting solution. Garage & Canopy SoftView SVPG Project: Location: Cat.No: Type: Qty: Notes: Accessories (ordered separately) FSIR-100 Handheld programmer (For use with 'IMRI' and'IMRIC' motion response when field programming is required). If desired, only one is needed per job. ES External House Side Shield (field installed) 347ST Step Down Transformer for 347V (field installed, consumes 2-3W) 480ST 3 Step Down Transformer for 480V (field installed, consumes 2-3W) Ordering guide Example: SVPG-168L-1200-NW-SM-5-UNV-WH Luminaire SVPG LED Count 168L System Drive Current Color Temperature Mounting Distribution Emergency Voltage Control Options Luminaire Options Finish SVPG SoftView Parking Garage 168L 168 LEDs 600 600mA 800 800mA 1200 1200mA 1800 1800mA WW Warm White 3000K (80 CRI) NW Neutral White 4000K (70 CRI) CW Cool White 5700K (70 CRI) SM Surface Mount PM Pendant Mount T Trunnion Mount 5 Type V CD Concentrated Downlight NONE Leave Blank EBP 1,2,3 Emergency Battery Pack 120 120V 208 208V 240 240V 277 277V UNV Universal 120-277V HVU 4,5 347- 480V NONE Leave Blank DD 9 0-10V Dimming LLC2 6,10 Wireless Controls IMRI 7, 10 Integral Motion Response IMRIC 7, 10 Integral Motion Response Factory Customizable F1 8 Single Fuse (120, 277V) 5,11 F2 8 Double Fuse (208, 240, 480V) 11 F3 8 Double Fuse Canadian double pull (208, 240, 480V) 11 WH White BZ Bronze MGY Medium Grey OC Optional Color Specify optional color or RAL ex: OC-LGP or OC-RAL7024. SC Special Color Must supply color chip. Requires factory quote. 1. Available with 120V-277V (UNV) input or 347V input when the 347VST is also used (steps 347V down to 240V). 2. Not available for use in Canada 3. Not available with 1800mA 4. HVU option requires use of step down transformer (347ST/480ST) ordered as an accessory. (Ships separately). 5. Single Fuse (F1) not available with step down transformer (347VST) accessory. 6. Not available with Emergency option (EBP). 7. Available with 120 OR 277V only. 8. Provide specific input voltage. 9. For dimming controls by others. 10. Includes 0-10V dimming driver (DD). 11. Must specify input voltage. 2016 Most Innovative Product of the Year Best in Category

Transcript of Project: Garage & Canopy - Villa Lighting Supply, Inc....Project: Location: Cat.No: Type: Qty:...

PGc-1506SS_SoftView-SS 06/16 page 1 of 6

Philips Gardco SoftView LED parking garage luminaires feature

edge lit technology, providing visual comfort with minimal glare

to enhance the user experience. An added uplight feature reduces

the cave effect for an increased sense of security. SoftView features

two distribution options and four lumen packages, providing up to

8,614 lumens for an ideal garage lighting solution.

Garage & Canopy

SoftView

SVPG

Project:

Location:

Cat.No:

Type:

Qty:

Notes:

Accessories (ordered separately)

FSIR-100 Handheld programmer (For use with 'IMRI' and'IMRIC' motion response when field programming is required). If desired, only one is needed per job.

ES External House Side Shield (field installed)

347ST Step Down Transformer for 347V (field installed, consumes 2-3W)

480ST3 Step Down Transformer for 480V (field installed, consumes 2-3W)

Ordering guide Example: SVPG-168L-1200-NW-SM-5-UNV-WH

Luminaire

SVPG

LED Count

168L

System Drive Current

Color Temperature

Mounting Distribution Emergency Voltage Control Options Luminaire Options Finish

SVPG SoftView Parking Garage

168L 168 LEDs

600 600mA

800 800mA

1200 1200mA

1800 1800mA

WW Warm White 3000K (80 CRI)

NW Neutral White 4000K (70 CRI)

CW Cool White 5700K (70 CRI)

SM Surface Mount

PM Pendant Mount

T Trunnion Mount

5 Type V

CD Concentrated Downlight

NONE Leave Blank

EBP1,2,3 Emergency Battery Pack

120 120V

208 208V

240 240V

277 277V

UNV Universal 120-277V

HVU4,5 347-480V

NONE Leave Blank

DD9 0-10V Dimming

LLC26,10 Wireless Controls

IMRI7, 10 Integral Motion Response

IMRIC7, 10 Integral Motion Response Factory Customizable

F18 Single Fuse (120, 277V)5,11

F28 Double Fuse (208, 240, 480V)11

F38 Double Fuse Canadian double pull (208, 240, 480V)11

WH White

BZ Bronze

MGY Medium Grey

OC Optional Color Specify optional color or RAL ex: OC-LGP or OC-RAL7024.

SC Special Color Must supply color chip. Requires factory quote.

1. Available with 120V-277V (UNV) input or 347V input when the 347VST is also used (steps 347V down to 240V). 2. Not available for use in Canada 3. Not available with 1800mA 4. HVU option requires use of step down transformer (347ST/480ST) ordered as an accessory. (Ships separately).

5. Single Fuse (F1) not available with step down transformer (347VST) accessory.6. Not available with Emergency option (EBP).7. Available with 120 OR 277V only.8. Provide specific input voltage.

9. For dimming controls by others.10. Includes 0-10V dimming driver (DD).11. Must specify input voltage.

2016Most Innovative

Product of the Year

Best in Category

PGc-1506SS_SoftView-SS 06/16 page 2 of 6

SVPG SoftView LEDParking garage luminaires

LED wattage and lumen values

Initial Lumen Output and Efficacy

Configuration # of LEDs

System

Drive Current Wattage

Color

Temperature 5 (Type 5) Efficacy

CD

(Concentrated

Downlight) Efficacy

SVPG-168L-600-NW 168 600 mA 27 4000K 3049 112 3320 122

SVPG-168L-800-NW 168 800 mA 35 4000K 3951 110 4302 120

SVPG-168L-1200-NW 168 1200 mA 55 4000K 5581 103 6077 112

SVPG-168L-1800-NW 168 1800 mA 85 4000K 7911 93 8614 102

Dimension drawings

System input wattage may vary based on input voltage, by up to +/- 10%, and based on manufacturer forward voltage, by up to +/- 8%.

Trunnion mount

4.0"(10.16cm)

0.41"(1.04cm)

0.53"(1.35cm)

3/4" (1.91cm)NPTFOR CONDUITPIPE

6.7"(17.02cm)

12.9 - 21"(32.7 - 53.34cm)

3.42"(8.69cm)

4.0"(10.16cm)

0.41"(1.04cm)

0.53"(1.35cm)

3/4" (1.91cm)NPTFOR CONDUITPIPE

6.7"(17.02cm)

12.9 - 21"(32.7 - 53.34cm)

3.42"(8.69cm)

Pendant mount

5.25"(12.6 cm)

18.5"(47.00cm)

12.9"

(32.7cm)

4.0"(10.16cm)

3.80"(9.65cm)

3/4" (1.91cm)NPTFOR CONDUITPIPE

Surface mount

5.25"(12.6 cm)

18.5"(47.00cm)

12.9"

(32.7cm)

4.0"(10.16cm)

3.80"(9.65cm)

3/4" (1.91cm)NPTFOR CONDUITPIPE

Side view Side view

Top view

Side view

Top view Top view

3.80"(9.65cm)

0.8"(2.03cm)

2.34"(47.00cm)

18.5"(47.00cm)

3.80"(9.65cm)

0.8"(2.03cm)

2.34"(47.00cm)

18.5"(47.00cm)

Motion response and wireless controls External house side shield

Side view Bottom view

4.0

Approximate Luminaire Weight:

10 lbs (4.5 Kg)

PGc-1506SS_SoftView-SS 06/16 page 3 of 6

SVPG SoftView LEDParking garage luminaires

Programmable motion response

2.33”59.2mm

0.78”19.7mm

FSP-L4: 360° CoverageThe FSP-L4 is designed for mounting at heights between 30’ to 40’ . Its coverage area can be up to 60’ in diameter when mounted at 40’ .

COVERAGE PATTERN

Density and range of the coverage pattern is determined by the type of lens and mounting height .

FSP-L2: 360° CoverageThe FSP-L2 lens provides a 44’ diameter coverage area when mounted at a height of 8’ .

FSP‑L3 High Densi ty/Reduced Range Lens

FSP‑L2 Low Densi ty/Wide Range Lens

03 9636912 12

10

20

0

15

5

151820 15 18 20

20 10 0 10 20

0

20

10

10

20

40 ft

2.33”59.2mm

0.78”19.7mm

30

30

20

10

10

20

0

8

0

10 0

0 33 77 1111 2222

10 2020

44 ft

FSP‑L4 40 Foot High Bay Lens

0 6 12 3061230 20 20

0

10

20

30

40

0 3 6 12 2730

36122730

20 20

036

36

12

27

30

12

27

20

20

60 ft

3.2”81.3mm

0.93”23.6mm

FSP-L3: 360° CoverageThe FSP-L3 has a high density lens that covers a 40’ diameter area at a height of 20’ .

WIRING A SINGLE SENSOR

Non-DimmingDriver

LIN

EN

EU

TRA

L

NEUTRAL

LOAD

* GROUND

Occupancy Sensor

5E4

800.879.8585www.wattstopper.com

1519

5r1

LOA

D

LIN

E

NEU

T(v

iole

t)

(gre

y)

18-20 AWG Solid CU Wire Only

230 VAC, 50 Hz1200W max ballast

FSP-211

GRN

D

DIM

-

DIM

+

14-18 AWG Solid CU Wire Only

High/Low PIR

Non-Dimming Driver

DimmingDriver

LIN

EN

EU

TRA

L

NEUTRAL

*GROUND

GRAY (-)

VIOLET (+)

LOAD

Occupancy Sensor

5E4

800.879.8585www.wattstopper.com

1519

5r1

LOA

D

LIN

E

NEU

T(v

iole

t)

(gre

y)

18-20 AWG Solid CU Wire Only

230 VAC, 50 Hz1200W max ballast

FSP-211

GRN

D

DIM

-

DIM

+

14-18 AWG Solid CU Wire Only

High/Low PIR

Dimming Driver

1 . Determine an appropriate mounting location inside the light fixture . Allow a minimum distance of 0 .2” (5 .1mm) from the wiring end of the sensor to the wall of the fixture .

2 . Drill a hole 1 .30” (33 .0mm) in diameter through the sheet metal in the bottom of the fixture .

3 . Add the rubber gasket to the threaded collar, and install the sensor face down, parallel to the mounting surface . Ensure the rubber gasket touches the inside surface of the fixture . Install the plastic nut securely against the fixture to a torque of 25-30 in-lbs to ensure IP rating is maintained .

4 . Align the locking features between the sensor and lens module and push the lens module forward until the o-ring seals firmly . Turn the lens module clockwise to ensure it locks in place .

5 . Connect load and supply wires as shown in wiring diagram .6 . Restore power from the circuit breaker .

CAUTION TURN THE POWER OFF AT THE CIRCUIT BREAKER

BEFORE INSTALLING THE SENSOR.

TighteningNut

TighteningNut Fixture

Wall

Lens Assembly

FSP-211

Outside Fixture Wall

Inside FixtureWall

RubberGasket

RubberGasket

Note: The Outside Fixture Wall thickness should be no greater than 0 .125” (3 .18mm) for optimal sensor mounting and security .

* Note: The FSP-211 must be grounded to ensure signal integrity, not for safety ground .

Outdoor Use at the exposed Sensor Collar part only when installed at the specific location per Installation

Instructions with a Listed Outdoor Enclosure.

INSTALLATION

30

30

20

10

10

20

0

8

0

10 0

0 33 77 1111 2222

10 2020

44 ft

Coverage Top View

Coverage Top View

Coverage Top View

Coverage Side View

Coverage Side View

Coverage Side View

2.33" / 5.92 cm

Coverage Side View

44'

.78" / 1.97 cm

FSP-211 COMMISIONING

The commissioning process establishes the appropriate param-eters for the FSP-211 operation . This is done through the use of the FSIR-100 commissioning tool . If no commissioning steps are taken, the sensor will use its default parameter values .

USING THE FSIR-100 PROGRAMMING TOOL

The FSIR-100 Wireless IR Programming Tool is a handheld tool for setup and testing of WattStopper FSP-211 .It provides wireless access to the FSP-211 sensors for setup and parameter changes .

The FSIR-100 display shows menus and prompts to lead you through each process . The navigation pad provides a familiar way to navigate through the customization fields .

Within a certain mounting height of the sensor, the FSIR-100 allows modification of the system without requiring ladders or tools; simply with a touch of a few buttons .

OPERATION

The FSIR-100 IR transceiver allows bi-directional communication between the FSP-211 and the FSIR-100 programming tool . Simple menu screens let you see the current status of the system and make changes . It can change FSP-211 sensor parameters such as high/low mode, sensitivity, time delay, cut off and more . With the FSIR-100 you can also establish and store FSP-211 parameter profiles .

BATTERIES

The FSIR-100 operates on three standard 1 .5V AAA Alkaline batteries or three rechargeable AAA NiMH batteries . The battery status displays in the upper right corner of the display . Three bars next to BAT= indicates a full battery charge . A warning appears on the display when the battery level falls below a minimum acceptable level . To conserve battery power, the FSIR-100 automatically shuts off 10 minutes after the last key press .

NAVIGATION

You navigate from one field to another using (up) or (down) arrow keys . The active field is indicated by flashing (alternates between yellow text on black background and black text on yellow background .

Once active, use the Select button to move to a menu or function within the active field . Value fields are used to adjust parameter settings . They are shown in “less-than/greater-than” symbols: <value> . Once active, change them using(left) and(right) arrow keys . In general the up key increments and the down key decrements a value . Selections wrap-around if you continue to press the key beyond maximum or minimum values . Moving away from the value field overwrites the original value . The Home button takes you to the main menu . The Back button can be thought of as an undo function . It takes you back one screen . Changes that were in process prior to pressing the key are lost .

FSP-201FSP-211FD-101FD-301

Home/MainMenu

Up

Select

DownRight/NextLeft

Back

PowerOn/Off

BAT=

IR COMMUNICATION

IR communication can be affected by the mounting height of the sensor and high ambient lighting such as direct daylight of electric light such as floodlights, and some halogen, fluorescent lamps, LED’s .

When trying to communicate with the FSP-211, be sure to be positioned under the sensor without any obstructions . Every time the programming tool establishes communication with the FSP-211, the controlled load will cycle .

• If communication is not successful, (if possible) move closer to the sensor .

• If still not successful, there may be too much IR interference from other sources . Programing the unit at night when there is no daylight available may be the only way to communicate with the sensor .

15'-30'

* Distance may vary depending on the lighting environment

FSP-211 COMMISIONING

The commissioning process establishes the appropriate param-eters for the FSP-211 operation . This is done through the use of the FSIR-100 commissioning tool . If no commissioning steps are taken, the sensor will use its default parameter values .

USING THE FSIR-100 PROGRAMMING TOOL

The FSIR-100 Wireless IR Programming Tool is a handheld tool for setup and testing of WattStopper FSP-211 .It provides wireless access to the FSP-211 sensors for setup and parameter changes .

The FSIR-100 display shows menus and prompts to lead you through each process . The navigation pad provides a familiar way to navigate through the customization fields .

Within a certain mounting height of the sensor, the FSIR-100 allows modification of the system without requiring ladders or tools; simply with a touch of a few buttons .

OPERATION

The FSIR-100 IR transceiver allows bi-directional communication between the FSP-211 and the FSIR-100 programming tool . Simple menu screens let you see the current status of the system and make changes . It can change FSP-211 sensor parameters such as high/low mode, sensitivity, time delay, cut off and more . With the FSIR-100 you can also establish and store FSP-211 parameter profiles .

BATTERIES

The FSIR-100 operates on three standard 1 .5V AAA Alkaline batteries or three rechargeable AAA NiMH batteries . The battery status displays in the upper right corner of the display . Three bars next to BAT= indicates a full battery charge . A warning appears on the display when the battery level falls below a minimum acceptable level . To conserve battery power, the FSIR-100 automatically shuts off 10 minutes after the last key press .

NAVIGATION

You navigate from one field to another using (up) or (down) arrow keys . The active field is indicated by flashing (alternates between yellow text on black background and black text on yellow background .

Once active, use the Select button to move to a menu or function within the active field . Value fields are used to adjust parameter settings . They are shown in “less-than/greater-than” symbols: <value> . Once active, change them using(left) and(right) arrow keys . In general the up key increments and the down key decrements a value . Selections wrap-around if you continue to press the key beyond maximum or minimum values . Moving away from the value field overwrites the original value . The Home button takes you to the main menu . The Back button can be thought of as an undo function . It takes you back one screen . Changes that were in process prior to pressing the key are lost .

FSP-201FSP-211FD-101FD-301

Home/MainMenu

Up

Select

DownRight/NextLeft

Back

PowerOn/Off

BAT=

IR COMMUNICATION

IR communication can be affected by the mounting height of the sensor and high ambient lighting such as direct daylight of electric light such as floodlights, and some halogen, fluorescent lamps, LED’s .

When trying to communicate with the FSP-211, be sure to be positioned under the sensor without any obstructions . Every time the programming tool establishes communication with the FSP-211, the controlled load will cycle .

• If communication is not successful, (if possible) move closer to the sensor .

• If still not successful, there may be too much IR interference from other sources . Programing the unit at night when there is no daylight available may be the only way to communicate with the sensor .

15'-30'

* Distance may vary depending on the lighting environment

SoftView luminaires with Programmable Motion Response (IMRI or IMRIC) include a passive infrared (PIR) motion sensor (WattStopper FS-211 equipped with an FS-L2W lens) capable of detecting motion within 22 feet of the sensor, 360° around the luminaire, when placed at an 8 foot mounting height. The PIR sensor is factory installed and integral to the luminaire as indicated in drawings on page 2. Available in 120V or 277V input only. Motion sensor off state power is 0.0 watts.

Programmable Motion Response (IMRI) luminaires are programmed at the factory as follows: when no motion is detected for 10 minutes, the Motion Response system reduces the wattage by 80%, to 20% (per RP-20) of the normal constant wattage, reducing the light level accordingly. When motion is detected by the PIR, the luminaire returns to full wattage and full light output. Dimming on low is factory set to 80% with duration set at 10 minutes. IMRIC luminaires are programmed at the factory per your custom requirements. Both IMRI and IMRIC include a daylight sensor which enables daylight harvesting.

The approximate motion sensor coverage pattern is as shown below.

FSIR-100 Wireless Remote Programming Tool

If you want to change the factory programming, the FSIR-100 Wireless Remote Programming Tool accessory enables on-site field adjustment of sensor settings, including duration and dimming level on low, without the need to connect any wires to the luminaire.

The FSIR-100 is a handheld tool that provides wireless access to the FSP-211 sensors for setup, testing and parameter changes.

The FSIR-100 display shows menus and prompts to lead you through each process. The navigation pad provides a familiar way to navigate through the customization fields.

Within 8-12' mounting height of the sensor, the FSIR-100 allows modification of the system without requiring ladders or tools simply with a touch of a few buttons.

The FSIR-100 IR transceiver allows bi-directional communication between the FSP-211 and the FSIR-100 programming tool. Simple menu screens let you see the current status of the system and make changes. It can change FSP-211 sensor parameters such as high/low mode, sensitivity, time delay, cut off and more. With the FSIR-100 you can also establish and store FSP-211 parameter profiles.

The FSIR-100 operates on three standard 1.5V AAA Alkaline batteries or three rechargeable AAA NiMH batteries. The battery status displays in the upper right corner of the display. Three bars next to BAT= indicates a full battery charge. A warning appears on the display when the battery level falls below a minimum acceptable level. To conserve battery power, the FSIR-100 automatically shuts off 10 minutes after the last key press.

You navigate from one field to another using (up) or (down) arrow keys. The active field is indicated by flashing (alternates between yellow text on black background and black text on yellow background.)

Once active, use the Select button to move to a menu or function within the active field. Value fields are used to adjust parameter settings. They are shown in “less-than/greater-than” symbols: <value>. Once active, change them using (left) and (right) arrow keys. In general the up key increments and the down key decrements a value. Selections wrap-around if you continue to press the key beyond maximum or minimum values. Moving away from the value field overwrites the original value. The Home button takes you to the main menu. The Back button can be thought of as an undo function. It takes you back one screen. Changes that were in process prior to pressing the key are lost.

More information on the FSIR-100 Remote Programming Tool is available at wattstopper.com.

PGc-1506SS_SoftView-SS 06/16 page 4 of 6

SVPG SoftView LEDParking garage luminaires

Wireless control system overview

Overview:One gateway is included with the wireless controls system. The gateway is the High Density RF Mesh ZigBee coordinator, allowing for real-time, two way communication between the graphical user interface and the SoftView luminaires in the parking garage. One Gateway can communicate with up to 800 fixtures. The gateway sends out an RF safety tone every 5 minutes. If a fixture does not receive the safety tone within 30 minutes, that fixture will be powered to high until connection is restored.

Installation:The back of the Gateway is equipped with (4) blind threaded holes that accept 10-32 screws. Mount spacing is 10.41” across and 14.19” vertical.

Specifications:- High density RF Mesh coordinator- Ethernet or cellular connection to LimeLight server- Proprietor of software “rules of operation”- Constructed to IP65 when used with waterproof connectors by others- Highly protected, long life ac/dc power supply- Single board, ARM compliant 520Mhz Intel computer.- Tamper proof housing

Requirements:Installed within the garage facility, the Gateway is powered by a 120V source and connected to the internet via an Ethernet cable or an integrated cellular modem. A 20 foot distance between the gateway and the first fixture is optimal.

Dimensions

12”(30.48 cm)

6”(15.24 cm)

15.63”(38.8 cm)

10.4”(26.4 cm)

14.2”(36 cm)

PWR LED

ETH0

ETH1

12”(30.48 cm)

6”(15.24 cm)

15.63”(38.8 cm)

10.4”(26.4 cm)

14.2”(36 cm)

PWR LED

ETH0

ETH1

12”(30.48 cm)

6”(15.24 cm)

15.63”(38.8 cm)

10.4”(26.4 cm)

14.2”(36 cm)

PWR LED

ETH0

ETH1

Front View

Back View

Side View

Gateway details

Wireless controls operate through high density mesh (HDM) wireless technology. When the mesh network is established, a path of communication will always find a way to each and every luminaire. It is this wireless mesh network that allows us to eliminate the need for running control wiring to each fixture and gives us the infinite flexibility to control luminaires, create and update fixture groupings, and update and check fixture status instantly via the web based GUI tool.

Radio modules, with motion and photocell sensors, are integrated into each luminaire (factory installed) and allow the LED luminaires to talk to one another via the ZigBee protocol. All radios can communicate with up to 16 neighboring fixtures to create the reliable mesh network.

PGc-1506SS_SoftView-SS 06/16 page 5 of 6

SVPG SoftView LEDParking garage luminaires

Radio and motion sensor details

0’

0’

8’

9’

10’5’ 20’ 25’15’10’ 5’20’25’ 15’

12.5’

0’

25’

12.5’

25’0’

0’

8’

9’

10’5’ 20’ 25’15’10’ 5’20’25’ 15’

12.5’

0’

25’

12.5’

25’

Typical Sensor Coverage

- Motion sensor coverage can be adjusted from a narrow to a wide (25' radius) detection range, which helps reduce false triggers to further increase energy savings.- 1.8 Watts max (no load draw)- Operating voltage 120-277 VAC RMS- Communicates using the ZigBee protocol- Carries out dimming commands from Gateway- Reports ambient light readings to 1500 Ft-Cd- Transmission Systems Operating within the band 2400-2483.5Mhz- ROHS Compliant- Sensing profiles can be updated to adapt to activity levels in the environment, such as occupancy level, wind, and mounting height.

3.80"(9.65cm)

0.8"(2.03cm)

2.34"(47.00cm)

18.5"(47.00cm)

PGc-1506SS_SoftView-SS 06/16 page 6 of 6

© 2016 Philips Lighting Holding B.V. All rights reserved. Philips reserves the right to make changes in specifications and/or to discontinue any product at any time without notice or obligation and will not be liable for any consequences resulting from the use of this publication.philips.com/luminaires

Philips Lighting North America Corporation200 Franklin Square Drive, Somerset, NJ 08873Tel. 855-486-2216

Philips Lighting Canada Ltd.281 Hillmount Rd, Markham, ON, Canada L6C 2S3Tel. 800-668-9008

SVPG SoftView LEDParking garage luminaires

Specifications

ConstructionDie-cast aluminum lower housing and upper heatsink. Upper polycarbonate lens provides uplight, tapered shape of upper housing deters dirt accumulation, eases cleaning frequency, and deters birds from sitting or nesting. UV- resistant acrylic lower lens.

IP RatingLuminaire optic and electrical housing constructed to IP66.

LED Thermal ManagementThe housing design provides thermal radiation fins in the upper housing to provide excel-lent thermal management critical to long LED system life.

Light EngineEdge-lit, light guide technology provides low-glare, uniform illumination. Composed of 168 mid power LEDs. Color temp: 3000K, 4000K, 5700K +/- 250K. Minimum CRI of 70.

Optical SystemType 5 symmetrical and concentrated downlight (CD). Light guide plate composed of high performance optical grade PMMA (polymethyl methacrylate) acrylic. Light guide technology allows for optimal light distribution without direct view of the LEDs, providing low-glare, uniform illumination. Up to 4% uplight eliminates cave effect.

ElectricalUL Class 2 constant current driver. High power factor (0.9 minimum). 120-277V. 50/60 Hz Ambient temperature range: -40°C (-40°F) to 40°C (104°F). Open/short circuit protection and voltage mode protection. Optional 0-10V dimming to minimum 10% power. RoHS compliant. Surge protector standard and is in

accordance with IEEE / ANSI C62.41.2 guidelines, with a surge current rating of 10KA.

For 347ST and 480ST options, an external IP66-rated step-down transformer is provided for direct mounting to a surface mounted junction box. Junction box supplied by others. Reference installation instructions for additional information.

MountingDie formed 16 ga. galvanized steel plate is supplied for mounting to a recessed or surface-mounted 4” (10.16 cm) junction box (by others) – flush ceiling mount to a recessed junction box, or direct mount to a surface-mounted junction box. Integral hanger tabs on the plate support the luminaire during wiring. Single screw secures luminaire for quick and easy installation. For pendant mounting options, casting has direct 3/4" NPT tapped hole for direct mounting onto rigid 3/4" pendant (by others). Trunnion mounting option is designed to mount to a concrete ceiling with an anodized aluminum trunnion bracket assembly (included and painted to match luminaire finish). The assembly permits (8) one inch incremental mounting height adjustments, ranging from 13 to 21 inches. A 3/4” NPT tapped hole is provided on upper casting for mounting directly to rigid or flexible conduit (by others).

ControlsMotion Response luminaires (IMRI and IMRIC) include a passive infrared (PIR) motion sensor (WattStopper FSP-211 equipped with an FS-L2W lens) capable of detecting motion within 22 feet of the sensor, 360° around the luminaire, when placed at an 8-12 foot mounting height. Available in 120V OR 277V input only. Motion sensor off state power is 1 watt. In Motion Response luminaires, when no motion is detected for 10 minutes, the Motion Response system reduces the wattage by 80%, to 20% of the normal constant wattage per RP-20, reducing the light level accordingly. When motion is detected by the PIR, the

luminaire returns to full wattage and full light output. Includes a daylight sensor which enables daylight harvesting. Wireless Remote Programming tool available (FSIR-100) for field programming (ordered separately).

Wireless controls also available, which combine the intelligence of motion and daylight sensing with wireless technology, allowing you to connect with your lighting system via the web.

Vibration ResistanceSoftView carries a 3G vibration rating that conforms to the standards set forth by ANSI C136.31. Testing includes vibration to 3G acceleration in three axes, all performed on the same luminaire.

EmergencyOptional internal emergency battery pack provides emergency light output for a minimum of 90 minutes when power is lost. Suitable for use in ambient temperatureconditions from 0°C (-32°F) to 35°C (95°F). EBP configuration is not available for use in Canada. Available with 120-277V, or 'UNV' only.

FinishStandard textured finishes include: BZ – Bronze Textured, WH – White Textured, MGY – Medium Grey Textured.

ListingsAll luminaires bear UL or cUL (where applicable) Wet Location labels. Suitable for use in ambients from -40° (-40°F) to 40°C (104°F). SoftView luminaires are DesignLights Consor-tium qualified.

Limited Warranty5-year limited warranty. See philips.com/luminaires for complete details and exclusions.

LED Performance:

PREDICTED LUMEN DEPRECIATION DATA8

Ambient Temperature °C

System CurrentCalculated L70

Hours8,9 L70 Per TM-219,10 Lumen Maintenance % @ 60,000 hours

25°C 1800 >100,000 >60,000 84%

8. Predicted performance derived from LED manufacturer’s data and engineering design estimates, based on IESNA LM-80 methodology. Actual experience may vary due to field application conditions.

9. L70 is the predicted time when LED performance

depreciates to 70% of initial lumen output.

10. Calculated per IESNA TM21-11. Published L70

hours

limited to 6 times actual LED test hours.