PROGRESS ON DEVELOPING ADAPTIVE OPTICS-OPTICAL
COHERENCE TOMOGRAPHY FOR IN VIVO RETINAL IMAGING:
MONITORING AND CORRECTION OF EYE MOTION ARTIFACTS
PRESENTED BY SWETHA.P
S7 EC1 ROLL NO.67
![Page 3: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/3.jpg)
Retinal Imaging Modalities
Fundus camera
Scanning Laser Ophthalmoscope (SLO)
Optical Coherence Tomography (OCT)
![Page 4: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/4.jpg)
FUNDUS CAMERA
Provide magnified view of fundus
Low power microscope with an attached camera
Reflected light pass through eyepiece
Button is pressed to take a picture
![Page 5: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/5.jpg)
Normal fundus photographs of left
eye (right image)
![Page 6: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/6.jpg)
SCANNING LASER OPTHALMOSCOPE (SLO)
Technique of confocal laser scanning microscopy for
diagnostic
Combined with adaptive optics technology to provide sharper
images
Uses horizontal and vertical scanning mirror
![Page 7: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/7.jpg)
SLO Retinal image of a left eye
![Page 8: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/8.jpg)
OPTICAL COHERENCE TOMOGRAPHY
Optical signal acquisition and processing method
Three-dimensional images from within optical scattering media (e.g., biological tissue)
The principle of OCT is white light or low coherence interferometry
Captures micrometer-resolution, three-dimensional images
Ultrashort pulsed lasers and supercontinum lasers are used
![Page 9: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/9.jpg)
![Page 10: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/10.jpg)
A- SCAN AND B-SCAN
A-SCAN
Determine eye length for calculation of intraocular lens
Performed using ultrasonic wave
It gives the information in the form of one dimensional
B SCAN
Brightness scan
Produce a two-dimensional, cross-sectional view of the eye
![Page 11: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/11.jpg)
Adaptive optics
Makes necessary optical correction
Permit faster modulation (higher frame rates)
FEATURES
Reduced speckle size
Increased lateral resolution
![Page 12: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/12.jpg)
Components of Adaptive optics
Wavefront sensor
Wavefront corrector
Control system
![Page 13: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/13.jpg)
The wavefront sensor and corrector measure and correct the
eye's wave aberrations
The AOcontroller controls the interaction between the
wavefront sensor and the corrector element
Interprets the wavefront sensor data and computes the
appropriate wavefront corrector drive signals.
AO systems operating in closed-loop
Measured wavefront is the error signal that gets fed back to the
controller
![Page 14: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/14.jpg)
![Page 15: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/15.jpg)
AO-OCT OCT design configurations have been combined with AO
Assessed using -standard AO and OCT metrics
More accurate and clear image
Point-spread functions achieved by
different retinal imaging systems
![Page 16: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/16.jpg)
Comparison in resolution •
OCT axial resolution Δz
depends only on the
coherence properties of the
light source
SLO system depends on the focusing
geometry of the beam used for
imaging
Transverse resolution (Δx) in OCT and SLO depends on the light source wavelength and
NA of the imaging optics.
![Page 17: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/17.jpg)
DRAWBACKS OF TRANSVERSE RESOLUTION
![Page 18: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/18.jpg)
Limited depth range over which the retinal structures remain in
focus
Structures in focus show high contrast
Out-of-focus areas appear similar to those in the low lateral
resolution OCT scan
![Page 19: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/19.jpg)
MOTION ARTIFACTS
Micro saccadic jerks - constant move of eye from one feature
to other
Slow drift of the eye
High frequency micro tremors - involuntary movement due
muscle contraction
![Page 20: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/20.jpg)
determination of motion artifacts
Co-register the b-scans
Co-register the b-scans to maximize the cross-correlation
between each adjacent pair
Real-time hardware-based correction
Additional light beam is used to determine distance to cornea
![Page 21: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/21.jpg)
advanced SYSTEM
![Page 22: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/22.jpg)
Yellow rays-AO-OCT path
Blue rays-AO-SLO path
Red rays-common path for both systems.
Hslo-slo horizontal scanner
HOCT-OCT horizontal scanner
V-vertical scanner
D-dichroic mirror
Dm-deformable mirror for adaptive optics
Pbs-pellicle beam splitter
Lf-low-pass optical filter,
SHWFS-shack-Hartman wavefront sensor.
![Page 23: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/23.jpg)
AO-OCT Data Acquisition
OCT use 836 nm light with a bandwidth of 112 nm
For SLO use 683.4 nm light with a bandwidth of 8.2 nm
SLO and OCT beams share the same path
Hslo,Hoct-separate SLO light from OCT light for the
horizontal scanning mirrors
![Page 24: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/24.jpg)
Both AO-OCT volume and AO-SLO image cover the same
lateral area of the retina
B-scan acquisition is repeated for different positions of the
OCT horizontal scanner
AO-SLO image cover the same lateral area of the retina
![Page 25: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/25.jpg)
Timing diagrams of vertical scanner (VS) and
horizontal OCT/SLO scanners HSOCT, HSSLO for
volumetric data acquisition.
![Page 26: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/26.jpg)
Schematic of main acquisition planes of AO-OCT
(B-scan) and AO-SLO (C-scan) in our instrument
![Page 27: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/27.jpg)
Experimental setup
![Page 28: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/28.jpg)
Detection of Eye Motion
Artifacts Uses AO-SLO image series to track eye movement
Construct a reference image
Several frames distributed throughout the AO-SLO image
Avoid frames that have significantly lower overall brightness
![Page 29: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/29.jpg)
Register the reference frames to maximize the cross
correlation between each selected frame
Average the registered frames
Divide the AO-SLO images into equally sized strips
Displacement of a strip from its expected location on the
reference image is the average displacement of the target
![Page 30: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/30.jpg)
Correction of eye motion
artifacts
![Page 31: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/31.jpg)
Advantages OCT can build up clear 3D images of thick samples by
rejecting background signal
Images can be obtained by ‘non-contact’
OCT as an echo technique is similar to ultrasound imaging
The motion corrected AO-OCT volumes reveal the actual
sampling pattern that are affected by motion artifacts
![Page 32: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/32.jpg)
Disadvantages
If the AO-SLO images do not exhibit a distinct texture, the
algorithm will not be able to construct a good composite
reference image
The conversion factors to change eye motion detected in
AO-OCT pixels must be accurate to ensure the correct
replacement of A-scans to their actual sampling locations
![Page 33: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/33.jpg)
Future scope
Improved diagnostic and monitoring of many eye diseases
(eg. Glaucoma)
Averaging of multiple volumes might allow visualization of
cellular structures that are not visible on a single volume due
to insufficient signal intensity or presence of coherence noise
Successful visualization of retinal ganglion cells(the cells that
send the signals from the retina to other parts of the brain)
![Page 34: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/34.jpg)
CONCLUSION AO-OCT is a relatively novel retinal imaging technology that
still continues to develop
Transverse chromatic aberrations shift the relative lateral position of OCT and SLO beams on the retina
Motion correction of in vivo AO-OCT volumes of the human retina has potentially significant benefits for vision and physiology
Reduce the number of scans need to be captured, ultimately reducing imaging time and increasing patient comfort
![Page 35: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/35.jpg)
REFERENCE Optical coherence tomography
Source: http://en.wikipedia.org/w/index.php
Adaptive Optics in Retinal Imaging
Source: http:/ / www.adaptiveoptics. org/ News_1006_3. html
Guyton AC, Hall JE. Human physiology and mechanisms of
disease. 6th ed. Philadelphia (PA): W.B. Saunders
Company;1997. p. 400–15
![Page 36: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/36.jpg)
![Page 37: Progress on DevelJBB,B,Noping Adaptive Optics-optical](https://reader033.fdocuments.in/reader033/viewer/2022051619/55cf9429550346f57ba00d13/html5/thumbnails/37.jpg)