Profile Cladding brochure - ESI · 2016. 6. 21. · Riblok150 Aluminium 0.7 0.56 150 1to15*...

12
Profiled Cladding ALUMINIUM AND STEEL PROFILED CLADDING SYSTEMS R I G I S S M E T S Y April 2010 (47) Nh CI/Sfb (47) Nh CI/Sfb

Transcript of Profile Cladding brochure - ESI · 2016. 6. 21. · Riblok150 Aluminium 0.7 0.56 150 1to15*...

  • Profiled CladdingA L U M I N I U M A N D S T E E L P R O F I L E D C L A D D I N G S Y S T E M S

    R IGI S SMETSYApril 2010

    (47) NhCI/Sfb

    (47) NhCI/Sfb

  • RigiSystems manufacture an extensive range of

    aluminium and steel profiled cladding systems

    for use in a variety of roof, wall and lining

    applications. The range of trapezoidal and

    sinusoidal profiles together with secret fix lining

    systems provide the specifier and contractor

    with an unbeatable choice of cost-effective

    cladding solutions to meet the most challenging

    of performance specifications.

    Creative building design often requires a

    softness of line and detail of feature that can't

    always be achieved with traditional profiled

    sheeting and flashing design. To meet this

    requirement RigiSystems are able to offer

    both smooth and crimp curved options together

    with profiled closure pieces, flashings and

    mitred units.

    Offering the ultimate in design flexibility,

    RigiSystems profiled cladding is available in a

    wide range of colours and finishes.

    Product SelectionPlease use the table below to select the cladding

    profile that best meets your requirements.

    Full details on each profile are given in the

    following pages.

    RIGISYSTEMS PROFILEDCLADDING - Aluminium & steel profiled cladding systems2

    **Can be smooth curved *Can be crimp curved

    Type C Type A Type B

    Product Reference Broad Rib Face Narrow Rib Face Narrow Rib FaceSupported Side Lap Supported Side Lap Unsupported Side Lap Page No.

    19/76/991 (‘S’ Type) � � �** 3

    20/100/1000 (MM10) � �** �** 4

    20/125/1000 �* �* �* 4

    20/200/1000 �* �* �* 5

    20/300/900 � � � 5

    32/167/1000 �* �* �* 6

    38/152/914 (R38/WA6) �* �* �* 7

    38/200/1000 � � �* 7

    40/143/1000 �* � � 8

    45/152/914 (WB6) � � �* 8

    50/167/1000 �* � �* 9

    65/152/762 � �* �* 9

    The RigiSystems Range of Profiled Cladding

  • *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Roof Cladding Liner Soffit

    A general purpose sinusoidal cladding sheet designed for use

    in a variety of applications. The symmetrical profile is ideal for

    forming into smooth curves. In exposed situations, it is

    recommended that two corrugation side laps be used, reducing

    the effective cover width to 914mm. Only available with an

    unsupported side lap.

    3

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    0.5 1.70 5-10° sealed and stitchedAluminium 0.7 2.36 @ 300 mm centres

    0.9 3.06 991 5° 1.5 to 15* 10-15° sealed and stitched0.5 4.89 @ 450 mm centres

    Steel0.7 6.86 >15° unsealed and stitched

    @ 450 mm centres

    991mm

    76.2mm

    19mm

    25mm 25mm914mm

    � � �

    Unsupported side lap

    RigiSystems 19/76/991 (‘S’Type)

  • 4

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    0.5 1.70 5-10° sealed and stitchedAluminium 0.7 2.38 @ 300 mm centres

    0.9 3.06 1000 5° 1 to 15* 10-15° sealed and stitched0.5 4.90 @ 450 mm centres

    Steel0.7 6.86 >15° unsealed and stitched

    @ 450 mm centres

    Roof Cladding Liner Soffit

    A lightly profiled sheet which is ideal for domestic roofing and cladding,

    canopy soffits, fascias, parapets and small span applications. It is

    particularly suited for use as a lining sheet with the RigiSystems Ziplok

    standing seam roofing system and can be supplied smooth curved.

    Available fully perforated, with a supported or unsupported side lap.

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    RigiSystems 20/125/1000

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    5-10° sealed and stitched

    Aluminium0.7 2.38 @ 300 mm centres0.9 3.06 1000 5° 1 to 15* 10-15° sealed and stitched0.5 4.90 @ 450 mm centres

    Steel0.7 6.86 >15° unsealed and stitched

    @ 450 mm centres

    Roof Cladding Liner Soffit

    A discretely profiled sheet that is ideal for domestic roofing andcladding, canopy soffits, fascias, parapets and small span applications.It is compatible with three other metric profiles in the profiled claddingrange making it a perfect lining sheet for cost-effective twin skinapplications. Available webb or fully perforated with a supported orunsupported side lap.

    1000mm

    100mm

    19.1mm

    25mm 25mm43mm

    1000mm

    125mm

    20mm

    25mm 25mm73.8mm

    � � � �

    � � � �

    Supported side lap

    Supported side lap

    RigiSystems 20/100/1000 (MM10)

    RIGISYSTEMS PROFILEDCLADDING - Aluminium & steel profiled cladding systems

  • 5

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Roof Cladding Liner Soffit

    Designed for use as a soffit lining sheet for forecourt canopies

    RigiSystems 20/300/900 has the aesthetics of a secret fix system at

    the cost of a profiled sheet. The 900mm cover width is available fully

    perforated with an unsupported side lap.

    See also Riblok on page 10 for soffit lining.

    RigiSystems 20/300/900

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    Aluminium 0.7 1.910.9 2.46 900 5° 1 to 15*

    Please contact our

    0.5 3.93 Technical Department

    Steel 0.7 5.50 for guidance

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Roof Cladding Liner Soffit

    A general purpose roof cladding sheet for applications where the

    loading/span requirements are kept to a minimum. The 1000mm

    cover width provides an extremely cost-effective solution.

    Available with a supported or unsupported side lap, also with flat

    pan if required.

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    5-10° sealed and stitched

    Aluminium0.5 1.57 @ 300 mm centres0.7 2.20 1000 5° 1 to 15* 10-15° sealed and stitched0.5 4.50 @ 450 mm centres

    Steel0.7 6.29 >15° unsealed and stitched

    @ 450 mm centres

    1000mm

    200mm

    20mm

    30mm 30mm30mm 20mm 142mm

    900mm

    20mm

    300mm 30mm

    � � �

    � � �

    Supported side lap

    Unsupported side lap

    RigiSystems 20/200/1000

  • 6

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    0.5 1.70 5-10° sealed and stitchedAluminium 0.7 2.38 @ 300 mm centres

    0.9 3.06 1000 5° 1 to 15* 10-15° sealed and stitched0.5 4.90 @ 450 mm centres

    Steel0.7 6.86 >15° unsealed and stitched

    @ 450 mm centres

    Roof Cladding Liner Soffit

    A cost-effective roof sheet for small spans and light loadings that canbe supplied with or without a supported side lap. RigiSystems32/167/1000 can also be used for vertical cladding where the outwardfacing broad ribs give a striking visual effect. For this application theside lap is reduced to make it a more economic option.

    1000mm

    167mm

    32mm

    25mm 25mm101mm

    � � � �

    Supported side lap

    RigiSystems 32/167/1000

    RIGISYSTEMS PROFILEDCLADDING - Aluminium & steel profiled cladding systems

  • 7

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Roof Cladding Liner Soffit

    Recognising the requirement for a 1000mm wide profiled sheet,RigiSystems 38/200/1000 uses the trapezoidal design of RigiSystems38/152/914 in this wider format. Whilst the loading characteristics areslightly lower than the RigiSystems 38/152/914, the 1000mm coverwidth provides an extremely cost-effective solution. Available webb orfully perforated, with a supported or unsupported side lap, also withflat pan if required.

    RigiSystems 38/200/1000

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    0.5 1.70 5-10° sealed and stitched

    Aluminium0.7 2.38 @ 300 mm centres0.9 3.06 1000 5° 1 to 15* 10-15° sealed and stitched1.2 4.08 @ 450 mm centres

    Steel0.5 4.90 >15° unsealed and stitched0.7 6.86 @ 450 mm centres

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Roof Cladding Liner Soffit

    A versatile cladding sheet that can be used for both roofingand vertical applications. For roofing applications it provides acost-effective and structurally sound solution that is easy tofix. For vertical applications the side lap detail is modified andthe profile is used with the reverse side outward to give abold visual effect. Available with a supported or unsupportedside lap.

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    0.5 1.70 5-10° sealed and stitched

    Aluminium0.7 2.38 @ 300 mm centres0.9 3.06 914 5° 1 to 15* 10-15° sealed and stitched1.2 4.08 @ 450 mm centres

    Steel0.5 4.90 >15° unsealed and stitched0.7 6.86 @ 450 mm centres

    914mm

    152.4mm

    38.1mm

    19mm 19mm82mm

    1000mm

    200mm

    38mm

    19mm 19mm

    � � � �

    � � �

    Supported side lap

    Unsupported side lap

    For a supported side lap detail please contact our Technical Department

    RigiSystems 38/152/914 (R38/WA6)

  • 8

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    5-10° sealed and stitched

    Aluminium0.7 2.61 @ 300 mm centres0.9 3.35

    10005° 1 to 15* 10-15° sealed and stitched

    0.5 4.91867

    @ 450 mm centresSteel

    0.7 6.87 >15° unsealed and stitched@ 450 mm centres

    Roof Cladding Liner Soffit

    A general purpose roof and cladding sheet suitable for most span andloading requirements. A special side lap detail with integral drainagechannel provides extra protection against roof leaks. Laps should stillbe sealed and the special eaves to ridge fixing sequence strictlyfollowed. Available with a supported or unsupported side lap.

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    RigiSystems 45/152/914 (WB6)

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    5-10° sealed and stitchedAluminium 0.7 2.27 5° @ 300 mm centres

    0.9 2.92 914 (4° in 1 sheet 1 to 15* 10-15° sealed and stitched0.5 4.87 ridge to eaves) @ 450 mm centres

    Steel 0.7 6.82 >15° unsealed and stitched@ 450 mm centres

    Roof Cladding Liner Soffit

    Similar in profile to RigiSystems 38/152/914, but with a profile depth of44.5mm, RigiSystems 45/152/914 has a far superior spanning capacityand is ideal where greater loadings are required. RigiSystems 45/152/914is available webb or fully perforated, with a supported or unsupportedside lap.

    914mm

    152.4mm

    44.5mm

    21mm 21mm41mm

    1000mm

    142.9mm

    40mm

    25mm 25mm64.9mm

    � � � �

    � � �

    Supported side lap

    Unsupported side lap

    RigiSystems 40/143/1000

    RIGISYSTEMS PROFILEDCLADDING - Aluminium & steel profiled cladding systems

  • 9

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Roof Cladding Liner Soffit

    A deep profile intended for roofing applications where strength, rigidityand depth of drainage channel are the main criteria. The deep profileof RigiSystems 65/152/762 gives a bold appearance and anaesthetically pleasing shadow line. Available with a supported orunsupported side lap.

    RigiSystems 65/152/762

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    5-10° sealed and stitchedAluminium 0.9 2.96 5° @ 300 mm centres

    1.2 3.94 762 (4° in 1 sheet 1 to 15* 10-15° sealed and stitched0.5 4.77 ridge to eaves) @ 450 mm centres

    Steel 0.7 6.68 >15° unsealed and stitched@ 450 mm centres

    762mm

    152.4mm

    63.5mm

    29mm 29mm29mm

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    Roof Cladding Liner Soffit

    A robust heavy-duty roofing and wall sheet which is particularlysuitable for large spans or heavy load applications. The designincorporates an integral drainage channel to provide extra protectionagainst roof leaks. Laps should still be sealed and the special eavesto ridge fixing sequence strictly followed. Available with a supportedor unsupported side lap.

    Nominal Typical Effective Minimum Sheet RecommendedMaterial Gauge Weight Cover Roof Length Side Lap

    (mm) (kg/lm) Width (mm) Pitch (m) Stitching Centres

    0.7 2.68 5-10° sealed and stitchedAluminium 0.9 3.45 1000 5° @ 300 mm centres

    1.2 4.59 (4° in 1 sheet 1 to 15* 10-15° sealed and stitched0.5 4.91

    833 ridge to eaves)@ 450 mm centres

    Steel 0.7 6.87 >15° unsealed and stitched@ 450 mm centres

    1000mm

    166.7mm

    50mm

    25mm 25mm75.2mm

    � � �

    � � �

    Supported side lap

    Supported side lap

    RigiSystems 50/167/1000

  • 10

    149.6mm13.1mm

    15.3mm

    18.2mm

    17.8mm6mm

    8.5mm7mm6.2mm

    18mm

    2.4mm 3.6mm

    Riblok 150R

    *Shorter/longer lengths available but may be subject to additional cost. Please contact RigiSystems for further details.

    RigiSystems Riblok

    Nominal Typical Effective Cover SheetMaterial Gauge (mm) Weight (kg/lm) Width (mm) Length (m)

    Riblok 150 Aluminium 0.7 0.56 150 1 to 15*

    Riblok 200 Aluminium 0.9 0.72 200 1 to 15*

    Riblok 300 Aluminium 0.9 0.97 300 1 to 15*

    Roof Cladding Liner Soffit

    The RigiSystemsRiblok range of

    secret fix cladding wasinitially developed for the

    petroleum industry to provide adurable and low maintenance soffit

    lining for forecourt canopies. Theaesthetically pleasing and clean lines proved

    so successful that the product application hasbeen extended to cover internal soffit applications,fascias and external wall design.

    Available in widths of 150, 200 and 300mm Riblokprovides a cost-effective solution for bothnewbuild and refurbishment projects. Riblok 150,

    200 and 300 are available with two facade profiles(R&F) and can be interchanged to create a numberof aesthetically pleasing designs.

    The Riblok panels are fixed in place by using aconcealed carrier system that is fixed to thesubstrate. The Riblok panels are simply snappedinto place together with mineral fibre insulation inthe void behind the exterior façade depending onthermal requirements. Work can commence fromeither edge of the cladding area, working across inthe same direction until complete.

    See also RigiSystems 20/300/900 on page 5 forsoffit lining.

    299.4mm13.1mm

    15.3mm

    18.2mm

    17.8mm6mm

    8.5mm7mm6.2mm

    18mm

    300mm

    Aluminium orgalvanised steel

    carrier

    2.4mm 3.6mm

    200mm13.1mm

    15.3mm

    18.2mm

    17.8mm6mm

    8.5mm7mm6.2mm

    18mm

    2.4mm 3.6mm

    299.4mm13.1mm

    15.3mm

    18.2mm

    17.8mm6mm

    8.5mm7mm6.2mm

    18mm

    2.4mm 3.6mm

    149.6mm13.1mm

    15.3mm

    18.2mm

    17.8mm6mm

    8.5mm7mm6.2mm

    18mm

    2.4mm 3.6mm

    � �

    Riblok 150F

    Riblok 300F

    Riblok 200F

    Riblok 300R

    RIGISYSTEMS PROFILEDCLADDING - Aluminium & steel profiled cladding systems

  • 11

    Fire PerformanceThe RigiSystems range of profiled claddingachieves the following results that enable them toachieve a Class O rating as classified by BuildingRegulations.

    Acoustic PropertiesA variety of systems to enhance the acousticproperties of the RigiSystems profiled claddingrange in terms of sound deadening andreverberation are available. For further information,please contact our Technical Department.

    Standards & ApprovalsRigiSystems profiled cladding is produced to thehighest quality standards including BS EN ISO9001: 1994. Products have been designed tofulfil a specific application and have beenmanufactured to precise standards and tolerances.

    Certificate No: 910442/A

    Guarantees &WarrantiesRigiSystems Industries will provide a productwarranty and guarantee on the internal and externalcoatings on a project by project basis. For furtherinformation, please contact our TechnicalDepartment.

    PackagingRigiSystems profiled cladding in steel is bundledand strapped with protective timbers top andbottom. aluminium profiled cladding is packed inthe same way but with the addition of polythenewrapping.

    DeliveryUnless otherwise indicated all deliveries are byroad transport, direct to the project site. Shippingby sea freight is subject to an additional cost.

    Test ResultBS476 : Part 3 : 1975External fire exposure FAA/SAAroof testBS476 : Part 7 : 1997 Class 1 Rating forTo determine the aluminium/steelclassification of the surface metal facingsspread of flame of products

    001

    •LL

    OY

    D’S

    REG

    I STE R

    Q UA LITYA

    SSU

    RA

    NC

    E

    I S O 9 0 0 1

    Product Properties

    Storagestorage on site prior to installation must be in acompletely dry environment to avoid corrosionoccurring between the sheets.

    Site InstallationFor instructions on site installation pleasecontact our Technical Department.

    Metal FacingsRigiSystems profiled cladding is available ineither 300 series aluminium or pre-painted Z275galvanised steel with the following finishes.Most products are also available in othersubstrates such as copper and stainless steel.Please contact RigiSystems for furtherinformation.

    Stucco embossed plain mill finish aluminium– ‘Plain mill finish aluminium is normallyexpected to last the life of the building withoutmaintenance’- BS 5427: 1976

    ARS – Abrasion resistant coating for aluminiumwith good handling characteristics providing along-term aesthetic life of approximately 15years.

    PVF2 – provides a long-term aesthetic life ofapproximately 20 years on aluminium, offeringexcellent durability and colour stability. Alsoavailable as a steel finish with a minimum life tomaintenance of 15 years due to the steelsubstrate.

    Plastisol – high performance coating for steelsubstrates.

    Polyester – a cost effective colour coating witha medium term life for both aluminium and steel.

    Durability of CoatingsThe durability of a metal coating is determinedby geographical location, local environment andthe colour selected. The information given aboveis intended as a general guide for locations in theUK. For further information please contact ourTechnical Department or the relevant coatingsmanufacturer.

    RigiSystems Industries reserve the right to amend product specificationswithout prior notice. The information and technical details included in thisbrochure are included as a guide only. For further information, pleasecontact our Technical Department.

  • R IGI S SMETSY

    Head OfficeRigiSystems Limited,

    Unit 62, Blackpole Trading Estate West,

    Worcester WR3 8ZJ

    RigiSystems FranceUne division de RigiSystems Ltd,

    25 rue Alfred Nobel

    77420 Champs sur Marne

    Local Operation ChinaRigidal Construction Systems (Xiamen) Co Ltd,

    Suite 316, Xiamen Bingo Business Centre,

    Zhongxin Huiyang Building,

    57 Hubin Bei Road,

    Xiamen, P.R. China 361012

    Tel: +44 (0)1905 750500

    Fax: +44 (0)1905 750555

    Email: rigisystems.org

    Website: www.rigisystems.org

    Tel: 01 60 06 00 15

    Email: [email protected]

    Website: www.rigidalfrance.com

    Tel: +86-592-5376000-93161

    Fax: +86-592-5376000-93160

    Email: [email protected]

    Website: www.rigidalchina.com

    RigiSystems reserve the rightto amend product specificationswithout prior notice.

    The information and technicaldetails included in this brochureare included as a guide only.

    For further information,please contact our TechnicalDepartment.