Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation...

27
Products to X-ray People for Security Presented to the: Technical Electronic Product Radiation Safety Standards Committee May 22, 2002

Transcript of Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation...

Page 1: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Products to X-ray People for Security

Presented to the:

Technical Electronic Product Radiation Safety Standards

CommitteeMay 22, 2002

Page 2: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

ANSI N43.17 Radiation Safety for Personnel

Security Screening Systems Using X-rays

Page 3: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Secure 1000

Manufactured by Rapiscan Products Inc.

Page 4: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Bodysearch

Manufactured by American Science and Engineering, Inc.

Page 5: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

• Sep. 1998: TEPRSSC Recommends a Mandatory Standard

• Apr. 1999: FDA Proposes New Project toANSI/HPS N43

• Nov. 1999: N43.17 TG Convenes• June 2001: Draft Standard Submitted to

N43 Committee• Apr. 2002: Final ANSI Approval

Chronology

Page 6: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Summary of Main Requirements

• Subject dose limits: 0.1Sv (10 µrem) Effective Dose per Scan250 Sv (25 mrem) per Year

• Benefit vs. Risk & Negligible IndividualDose (< 10 µSv/y)

• Subject Informed of the X-Ray Exposureand Associated Risk

Page 7: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Summary of Main Requirements

• Radiation Leakage:2.5 Sv/h (0.25 mrem/h) @ 30 cm from Surface

• Bystander Protection:Inspection Zone — 20 Sv/h (2 mrem/h)

• Safety Interlocks• Labeling & Indicators

Page 8: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Summary of Main Requirements

• Operator Training• Manufacturer Records• User Facility Records

Page 9: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Informative Annexes

• Risks and Rationale• Measurement Protocol and Estimation

of Effective Dose

Page 10: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.
Page 11: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.
Page 12: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.
Page 13: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.
Page 14: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.
Page 15: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Transmission X-Ray Products

Page 16: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Transmission X-Ray(Conpass Body Scanner)

Manufactured by MMC International

Page 17: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Transmission X-Ray

Page 18: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Specifications(Conpass Body Scanner)

• Scanning Time: 10 Seconds• Anode Voltage: 70 - 200 KvP with 10 kV Step• Tube Current: 1- 3 mA with 0.5 mA Step• Dose to a Subject: 0.5 mrem per Inspection• Dose to Operator < 0.5 mrem per hour• Note: Other Systems Exist

Page 19: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Mfr’s Proposed Uses

• Passenger Control

• Diamond Mines

• Prisons

• Public Offices

• Banks

• Etc.

Page 20: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Issue

• Non-medical Exposure to Ionizing Radiation

Linear no threshold model

Societal benefit from increased security

Page 21: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Principles

• 1 mrem Negligible Individual Dose

• 100 mrem Annual Public Effective Dose Limit

• Individual or Society Receives a Clear and Compelling Benefit that Outweighs Risk

• Dose as Low as Reasonably Achievable

Page 22: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Negligible Individual Dose

• NCRP Recommends: An Annual Effective Dose Of 1000 µRem Be Considered A Negligible Individual Dose Per Source Or Practice

Magnitude of the dose

Difficulty in detection and measurement of dose and health effects

Estimated risk for the mean and variance of natural background radiation exposure levels

Page 23: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Transmission vs. Backscatter

• X-Ray Transmitted Through the Subject• Image Interpretation Significantly More Complex• Adjustable Technique Factors (More Complex)• 100x More Dose to Subject

Page 24: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Regulatory Status

• They are Not Medical Devices

• They are Electronic Products that Emit Radiation

• Currently No Federal Performance Standard Applies to these Products (21 CFR 1010 through 1050)

Page 25: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

FDA’s Proposed Response

• Guidance Document

• Radiation Safety Recommendation

• Mandatory Performance Standard

• New Instruments

• Suggested State Regulations

Page 26: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Proposed Mandatory Standard

• Based on ANSI N43.17• Dose Limit• Interlocks• Labeling & Indicators• Controls• Product Performance Only

Use Covered in a Radiation Safety Recommendation

Page 27: Products to X-ray People for Security Presented to the : Technical Electronic Product Radiation Safety Standards Committee May 22, 2002.

Discussion

• Societal Benefit vs. Risk

• Appropriate Use?

• Scope of StandardWhat Products?

Alternatives Based on Intended Use?

Controls – Fixed or Automatic?