Products for Orthopaedics Manufacturing Surgery Quality ...

22
Made in India by: G. Surgiwear Limited Rasoolpur Jahanganj, Shahjahanpur-242001 Tel: +91 5842-223818 Fax: +91 5842-222190 e.mail: [email protected] Delhi: 011 - 65454565, Mumbai: 022 - 66994258, Ahmedabad: 079 - 27545218 Manufacturing Quality Products for Orthopedics Neurosurgery Ophthalmology Plastic Surgery Urosurgery Andrology Cardiothoracic Laparoscopic Obst. Gynae Burn Treatment Wound Dressing Emergency Pressure Dressing General Use Products for Orthopaedics Surgery

Transcript of Products for Orthopaedics Manufacturing Surgery Quality ...

Made in India by:

G. Surgiwear Limited

Rasoolpur Jahanganj, Shahjahanpur-242001

Tel: +91 5842-223818 Fax: +91 5842-222190

e.mail: [email protected]

Delhi: 011 - 65454565,

Mumbai: 022 - 66994258,

Ahmedabad: 079 - 27545218

Manufacturing Quality Products for

Orthopedics

Neurosurgery

Ophthalmology

Plastic Surgery

Urosurgery

Andrology

Cardiothoracic

Laparoscopic

Obst. Gynae

Burn Treatment

Wound Dressing

EmergencyPressure Dressing

General Use

Products for OrthopaedicsSurgery

Table of Content

1

G-Bone Synthe�c HA Powder SHAP 03

G-Gra� Natural hydroxyapa�te 05with natural collagen.

G-Bone Modified Hydroxyapa�te 07

G-Bone Synthe�c Hydroxyapa�te 09

G-Bone Cement 10Calcium Phosphate Cement

G-Bone for Dental Socket - SHAG31 11

G-PATCH/G-PATCH-2 Synthe�c Fabric Patch 14

Knee O Drape 15

Hip U Drape 16

Elbow O Drape 17

Shoulder Drape 18

Knee Arthroscopy Drape 19

Shoulder and Cling Drape 20

Disposable Drapes 21

Disposable Drapes 22Lamino-Spinal Drape

Disposable Drapes 21

Drape Kits for Orthopaedic Surgery 30

"Zero-F" Mop Zero Fiber Mop 33

White Mop 34

Wound Dressings 35

Miscellaneous products 38

UEM Splint Universal Emergency Splint 30

Miscellaneous Devices 41

Innova�ons for a healthier world.

In 15-20% cases the bone ends of fractured bone do not unite and non union/ delayed union occurs.

It is equally common in all types of cases. Whether it is closed reduc�on, open reduc�on with screw plates or nailing. There are variety of causes such as clot forma�on, interposi�on of so� �ssue between ends of bone.

SURGIWEAR brings you HA powder to be injected between and around ends of broken bones.

in all cases of open or closed reduc�on. This will improve the environment around the fracture and increase chances of healing by providing an environment of Calcium & Phosphate ions the building blocks of bone. It will increase ac�vity of Osteoclasts and osteoblasts in the vicinity of fractured bone ends.

Closed injec�on of HA powder can be repeated a�er 7-20 days depending upon X-ray visualisa�on of bone healing ac�vity / callus. If callus is not visible a�er three weeks. Repeat injec�on of HA Powder is recommended.

The quality of SURGIWEAR HA powder is that it will not diffuse around and will remain coalesced as injected for prolonged period.

You may expect a significant reduc�on in non union cases.

Put the powder on plas�c petri dish

add sterile dis�lled water & mix with spatula

Make paste to a flowable consistancy.

Prevent non union of fractured boneG-Bone Synthe�c HA Powder SHAP

Prevent non union of fractured boneG-Bone Synthe�c HA Powder SHAP

Inject under C-arm visualiza�on between and around ends of bone. Depending upon the fracture you may have to use 10-50 gms of powder.

Load the paste into the syring

from open wide end of barrel.

G-B

on

e S

ynth

e�c

HA

Po

wd

er

SH

AP

3 4

INTRODUCTIONConventional bone grafting is done with autologous bone graft from iliac crest, which is still the gold standard. However, it involves another operative procedure, longer operating time and more trauma to the patient. The donor site becomes painful after healing.

Surgiwear has developed xenograft in the name of G-Graft. It is natural Hydroxyapatite with natural collagen and with naturally occurring trabecular pattern. It is very useful for bone repair and replenishment. It can be used in weight bearing areas.

One should remember that results of use of G-Graft may be inferior to autologous bone.

DESCRIPTIONG-Graft is made of natural low crystalline Hydroxyapatite with collagen. It is available in form of granules, dowels and blocks. The shape can be changed by using Gigli saw and bone nibblers.

The information, given here, is not exhaustive and is for guidance only. The surgeon is best advised to use the method, which his own practice and discretion dictate to be best for the patient.

INDICATIONSG-Graft is indicated in almost all the places where a bone graft is required. Following are some of the indicative uses specialty wise.

Neurosurgery: Lumber & cervical fusion, vertebral reconstruction, cranial reconstruction and other types of reconstructions.

· Orthopedic Surgery: Lumber & cervical fusion, vertebral reconstruction, cranial reconstruction and other types of reconstructions, Cavity filling, osteotomy reconstructions, non union fracture and filling the gaps in cases of bone loss due to trauma.

· Plastic Surgery: Maxillofacial reconstructions, bony augmentation, hand surgery & cavity filling.

· Dental Surgery: Maxillofacial reconstruction surgery, periodontics, orthodontics and other areas requiring a bone graft.

· Other Specialties: Where a bone graft is required.

CONTRAINDICATIONSPresence of infection whether local or general, prohibits all kind of implantation procedures. Open wounds will not respond well with bone grafting surgeries.

Poor general health and metabolic deficiencies will not produce desired results.

Above mentioned contraindications are general. The surgeon must evaluate the individual patient for the risks involved.

WARNINGS Collapse of G-Graft is a possibility.Do not re sterilize G-Graft.Only blocks with weight bearing line should be used for weight bearing areas.The slot line on the block should be parallel with weight bearing axis of the body.

METHOD OF USEG-Graft implantation is an implantation procedure. It carries a greater risk of infection because of large surface area. It is advisable to take all precautions necessary for an implantation procedure. Some of the points are given below:a. It should be first procedure in the morning.b. There should be minimum number of people inside thetheatre (4persons). No scrub nursec. There should be minimum movement inside OT.d. Procedure should be as fast as possible 20-50 minutes.e. Use disposable mops only ( it is a must)f. Use disposable drapes.g. Use incise drapes on incision sites.h. Only 2-4 procedures in a day.i. The grafting material should be opened only just before implantation. j. Minimum handling of graft material.k. Use skin staplers for skin closure.After opening the site of implantation, obtain good hemostasis of the area. Scrap the walls of the cavity/defect. Remove all soft tissue from the cavity or defect. Harvest some bone and bone marrow from the same site by scraping and shallow drilling in the cavity. Incorporation of patients own bone and bone marrow provides BMP's for bone healing and improves results. Larger cavity size needs larger percentage of patients own bone. Fill gap with G-graft blocks or granules.Cover the gap with soft tissue. Gelatine foam sponge may be used to cover the granules and to prevent spilling of granules. Calcium phosphate cement (G-Bone CP Cement) may also be used to secure the granules and top the cavity.

COMPLICATIONSComplications which may result from the use of this product include the risks associated with the medication and methods utilized in the surgical

G-Gra� Natural hydroxyapa�te with natural collagen.

G-Gra� Natural hydroxyapa�te with natural collagen.

procedure, as well as patients response, reaction or degree of intolerance to any foreign object implanted into the body.

Some complications specific to G-Graft are following

* Collapse of block: There must be secondry arrangements to prevent damage due to collapse of block

* Fracture of G-Graft

* Lack of integration

The medical literature is full of hazards and complications associated with use of Calcium Hydroxyapatite. Some of the major hazards are infection, extrusion of grafted material, serous discharge, serous collection, hemorrhage, skin erosion and migration.

Granules 10cc pack

0.5-0.9 mm average particle size GGG1

0.9-1.9 mm average particle size GGG2

1.8-5.0 mm average particle size GGG3

Granules 1cc pack

0.5-0.9 mm average particle size GGG11

0.9-1.9 mm average particle size GGG21

1.8-5.0 mm average particle size GGG31

Chips 10cc pack

5x 15 mm average chip size GGC1

Blocks Average Block size and qty

30 x 15 x 6 mm 1no. GGB6

30 x 15 x 7 mm 1no. GGB7

30 x 15 x 8 mm 1no. GGB8

30 x 15 x 9 mm 1no. GGB9

30 x 15 x 10 mm 1no. GGB10

30 x 15 x 12 mm 1no. GGB12

30 x 15 x 14 mm 1no. GGB14

30 x 15 x 16 mm 1no. GGB16

30 x 15 x 18 mm 1no. GGB18

30 x 15 x 20 mm 1no. GGB20

Dowel Average Dowel size and qty. One

Dia 8, length 10 mm GGD8

Dia 10, length 12 mm GGD10

Dia 12, length 19 mm GGD12

Dia 13, length 19 mm GGD13

Dia 14, length 19 mm GGD14

Dia 15, length 19 mm GGD15

Dia 12, length 5 mm GGBP1

G-G

ra�

G-B

on

e S

ynth

e�c

HA

Po

wd

er

SH

AP

6

G-Bone Modified Hydroxyapa�te

Modified Hydroxyapatite

Surgiwear's Hydroxyapatite products are world renowned and have successful user experience of more than 16 years.

Modified hydroxyapatite is a combination of HA 40% (hydroxyapatite) & ß-TCP (beta-tricalcium phosphate)is 60%. It consists of nano crystal agglomerates.

It has excellent osteo-conductive properties borderingto the level of osteo-inductive property. With this material bone healing is very fast.

Microstructure of as-synthesized Modified HA block

Supplied ready to use Gamma-ray sterilized in double peel open packaging.

Granules 10cc Pack

0.1-0.4 mm average Particle Size MHAG1

0.4-0.9 mm average Particle Size MHAG2

0.8-1.8 mm average Particle Size MHAG3

1.8-3 mm average Particle Size MHAG4

Granules 1cc Pack

0.1-0.4 mm average Particle Size MHAG11

0.4-0.9 mm average Particle Size MHAG21

0.8-1.8 mm average Particle Size MHAG31

Blocks Average Block size & quantity

1 x 0.5 x 0.5 cm 20 nos. MHAB1

1 x 1 x 2 cm 5 nos. MHAB2

1 x 1.5 x 2 cm 3 nos MHAB3

2 x 2.5 x 0.3 cm 1 no. MHAB4

2 x 2.5 x 0.5 cm 1 no. MHAB5

G-G

ra�

7 8

The non ceramic Hydroxyapatite bone material has two components . The powder is made of tri calcium phosphate and tetra calcium phosphate. The fluid has different sodium and calcium salts. The two parts are mixed and putty like material is obtained. It can be used to fill the defects

After mixing it is usable for 3-5 minutes. Adding some drops of water can prolong usability but it may disturb ultimate strength. The hardening process continue and ultimate hardening may take 12-24 hours.

It can also be mixed with antibiotics for slow release of antibiotic at the site.

Supplied sterile. The kit contains powder sachet, liquid ampule, spatula, syringe and mixing dish.

G-Bone CPC

2 gm packing GBCEM15 gm packing GBCEM2

Synthetic Hydroxyapatite

Surgiwear's Hydroxyapatite products are world renowned and have successful user experience of more than 16 years.

Synthetic Hydroxyapatite is a pure naocrystalline HA. Nano crystals mimic biological HA, present in our human body.

Here healing is faster than other macrocrystal HA available from other sources.. It consists of nano crystal agglomerates.

It has excellent osteo-conductive properties.

Granules 10cc Pack0.1-0.4 mm average particle size SHAG1 0.4-0.9 mm average particle size SHAG2

Granules 1cc Pack0.1-0.4 mm average particle size SHAG11 0.4-0.9 mm average particle size SHAG21

Blocks Average Block size and quantity1 x0.5 x 0.5 cm 20 nos SHAB1 1 x 1 x 2 cm 5 nos. SHAB2

Dowel These dowels are made of nano crystalline HA with absorbable fibers. These are very strong due to fibers.

Average Dowel sizeDia 12 length 14 mm SHAD1 Dia 14 length 16 mm SHAD2 Dia 16 length 18 mm SHAD3 Dia 18 length 20 mm SHAD4 Dia 20 length 22 mm SHAD5

Injectable HA nano crystalline powderThis powder is to be mixed with sterile distilled water to make an injectable paste. It can be injected through a thick needle (14 gauge) to the site. useful for non-union of bone.

Synthetic HA Powder SHAP

Soft Synthetic HAThis unique HA granule becomes soft like sponge on wetting with saline or water. It can be molded like putty. It can be easily used to fill cavities.

Soft Granules 10 cc pack0.8-1.8 mm average particle size SHAG3 1.8-3 mm average particle size SHAG4

Soft Granules 1cc pack1 cc packaging has 4 small packaging for dental use. One 1/4 packaging is more than sufficient for one dental socket filling after extraction. By virtue of being soft like sponge it will be held in place & will not wash out.

0.8-1.8 mm average particle size SHAG31

Soft Carve-able blocksThese blocks when wet with saline or water can be carved using sharp blade.1 x 1.5 x2 cm 3 nos SHAB3 2 x 3 x3 cm 1 no. SHAB6

G-Bone Synthe�c Hydroxyapa�teG-Bone Cement

Calcium Phosphate Cement

9 10

G-Bone for Dental Socket - SHAG31

After tooth extraction a bony socket or alveolus is left. This socket is filled with blood clot. The clot later gets converted into bone.

However during conversion into bone the shape of alveoulus is not retained. It collapses and resorbed. The cheek side gets absorbed more deshaping the ridge. This collapsed dental ridge is not very suitable for dental implants or denture.

To preserve shape of alveolus, after extraction it must be filled with G-Bone synthetic or other bone graftingproducts from SURGIWEAR. During regeneration process of alveolus it prevents collapse and facilitate fast bone healing.

SURGIWEAR's G-Bone Synthetic SHAG31 is soft like sponge, after wetting. It can be filled into alveoulus without fear of spilling. Being soft it takes the shape of alveoulus.

In below x-ray, one root was filled with SHAG31. After 3 months new bone has formed.

GIVE BACK SMILETO YOUR PATIENTS WITH

SURGIWEAR HA

Instruc�on for use for SHAG31

First of all cut the blocks to the shape & size of alveolus

Place the cut piece into the alveolus. A�er placement into the alveolus, it will absorb blood & will become so�. Pack it intothe cavity. Suture the mucosa.

G-Bone for Dental Socket - SHAG31

12

DESCRIPTION

The SURGIWEAR “SYNTHETIC FABRIC PATCH” is designed to repair defects in soft tissues & re-enforcement of soft tissues such as DURAMATER, Peritoneal pleura etc. The patch is made of Poly Propylene (same as PROLENE Mesh). G-Patch-2 is made of Bio absorbable polymer Each pack contains one patch.

G-Patch is available in three sizes and custom sizes as well.

INDICATIONS

G-Patch is indicated for repair of Duramater, repair of peritoneum or places, where ever soft tissue repair is required.

CONTRAINDICATIONS

Presence of all kinds of infection (meningitis, ventriculitis, skin infection, bacteremia, septicemia and peritonitis etc.) whether local or general, prohibits all kind of implantation procedures. It is advisable to avoid implantation in such cases.

G-Patch is not a strong fabric. It should not be used in places where large tensile forces are expected. In such places stitch may not hold and it may give way and torn.

METHOD OF USE

Surgical Procedure

The implantation of G-Patch is a simple procedure. The patch is shaped and cut as per requirement. It is stitched with the tissue around the defect. Special care is required to use it as dura substitute. Water tight stitching is required to avoid leakage of CSF.

It should not be used without reinforcement in repair of peritoneum. The choice of exact procedure depends upon the training of neurosurgeon, customs in that hospital, country. Therefore the surgeon is best advised to use method, which his/her own practice and training dictate to be best for the patient.

HOW SUPPLIED

G-Patch is supplied in three sizes. Custom sizes are also available. These are available sterile by EO gas in double peel open packing.

G-Patch

Small 8 x 10 cm GP01Medium 10 x 12 cm GP02Large 15 x 20 cm GP03

G-Patch-2

Small 8 x 10 cm GP01-2Medium 10 x 12 cm GP02-2Large 15 x 20 cm GP03-2

WARNINGS

This device has not been tested for compatibility with all drugs and therefore should be used with caution.

Occasionally, fibrous adhesions or fibrosis will bind the patch with the adjacent tissues. Tissues may adhere with it. This adhesion may cause harm. Inflammation and or foreign body reaction may occur in surrounding tissues and organs. Excessive tension may tear the patch.

PRECAUTIONS

Prior to surgery, prospective patients and or their representative should be informed of the possible complications associated with the use of this product.

The patch should be carefully secured to the surrounding tissue with ligatures in such a manner as to avoid cutting or tearing the patch.

G-PATCH/G-PATCH-2Synthetic Fabric Patch

G-P

atch

13 14

Knee O Drape

Uses: For all kind of surgery in Knee & Knee replacement

KNEE O DRAPE D505

Material : 65-77 gsm spun lace fabric water repellant

Over all Size 240 x 340 cmElastic Aperture 5 cm dia 2 pockets 10 x 35 cm2 Tube & Cable holders C Arm cover 70 x 85 cmAbsorbent work pads 50 x 10 cm (2 nos)Poly sheet lining 120 x 120 cm

KNEE O DRAPE E515

Material: 40-50 gsm SMS polypropylene water repellantOver all Size 240 x 340 cmElastic Aperture 5 cm diaPoly sheet lining 120 x 120 cm

KNEE O DRAPE INT I525

Material : 65-77 gsm spun lace fabric water repellantOver all Size 240 x 310 cmElastic Aperture 5 cm dia 2 pockets 10 x 35 cm 2 Tube & Cable holders C Arm cover 70 x 85 cmAbsorbent work pads 50 x 10 cm (2 nos) Poly sheet lining 120 x 120 cm

KNEE O DRAPE POLY P5005

Material : Polymer sheet Over all Size 240 x 340 cmElastic Aperture 5 cm dia Absorbent work pads 70 x 125 cmTube & Cable holder

Hip U Drape

Uses: For all kind of surgery in hip area including Hip replacement

HIP U DRAPE D501

Material : 68-77 gsm spun lace fabric water repellant

Head Sheet Size 2.0 x 2.4 mAdhesive strip 4 cm x 1.5 m2 pockets 12 x 35 cm2 Tube & Cable holders work pad 30 x 50 cmU Sheet Size 1.75 x 2.40 mU cut 2 cm x 20 cm Straight 24 cm round Absorbent work pads 50 x 10 cm (2 nos) Poly sheet lining 1.20 x 1.25 m

HIP U DRAPE E511

Material: 40-50 gsm SMS polypropylene water repellant

Head Sheet Size 2.0 x 2.4 mAdhesive strip 4 cm x 1.5 mU Sheet Size 1.75 x 2.4 mU cut 2 cm x 20 cm Straight 24 cm round Poly sheet lining 1.20 x 1.25 m

HIP U DRAPE INT I521

Material : 68-77 gsm spun lace fabric water repellant

Head Sheet Size 2 x 2.4 mAdhesive strip 4 cm x 2.4 m2 pockets 12 x 35 cm2 Tube & Cable holders work pad 30 x 50 cmU Sheet Size 2.4 x 2.4 mU cut 2 cm x 30 cm Straight 24 cm round Absorbent work pads 50 x 10 cm (2 nos) Poly sheet lining 1.2 x 1.25 m

HIP U DRAPE Poly P5001

Material : Polymer sheet

Head Sheet - Size 2.2 x 2.2 mAdhesive strip - 4 cm x 2.2 mwork pad 30 x 50 cm 2 nos & 10 x 50 cmU Sheet- Size 2.2 x 2.2 mU cut - Straight 2 cm x 30 cm Round 24 cm

HIP O Drape Poly P5000

Material: Polymer sheet

Overall size: 240 x 340 cmWork pad 125 x 70 cmElastic hole 20 x 17 cmTube and cable holder

240 cm

340 cm

240 cm

320 c

m

Double Knee O drape D5025

Material: Polymer sheetOverall size 240 x 320 cmWork pad 120 x100 cmElastic holes 2 nos

Double Knee O drape Poly P5025

Material: Polymer sheetOverall size 240 x 320 cmWork pad 120 x120 cmElastic holes 2 nos

220 cm

22

0 c

m2

20

cm

240 cm

340 c

m

240 cm

340 c

m

Isolation Drape Poly P1001

Material: Polymer sheet

Overall size: 220 x 320 cmIncise area 15 x 35 cmWork pad 15cm wide all around 35 x 55 cmTube and cable holder

Dra

pe

s

G-P

atch

16

Elbow O Drape Shoulder Drape

Uses: For all kind of surgery on Elbow and forearm

ELBOW O DRAPE D506

Material : 65-77 gsm spun lace fabric water repellant

Over all Size 150 x 120 cmElastic Aperture 5 cm dia

2 pockets 10 x 35 cm2 Tube & Cable holders

C Arm cover 70x85 cm

Absorbent work pads 50 x 10 cm (2 nos)

Poly sheet lining 120 x 120 cm

ELBOW O DRAPE E516

Material : 40-50 gsm SMS polypropylene water repellant

Over all Size 150 x120 cmElastic Aperture 5 cm dia

Poly sheet lining 120 x 120 cm

ELBOW O DRAPE I526

Material : 65-77 gsm spun lace fabric water repellant

Over all Size 240 x 220 cmElastic Aperture 5 cm dia2 pockets 10 x 35 cm

2 Tube & Cable holders

C Arm cover 70x85 cm

Absorbent work pads 50 x 10 cm (2 nos)

Poly sheet lining 120 x 120 cm

Uses: For all kind of surgery in Shoulder area including Shoulder replacement

SHOULDER U DRAPE D502

Material : 68-77 gsm spun lace fabric water repellant

Head Sheet Size 1.25 x 1.6 m

Adhesive strip 4 cm x 1.5 m

U Sheet Size 2 x 1.5 mU cut 2 cm x 15 cm Straight 16 cm round 2 Tube & Cable holdersAbsorbent work pads 50 x 10 cm (2 nos) Poly sheet lining 1.2 x 1.2 m

SHOULDER U DRAPE ECO E512

Material : 40-50 gsm SMS polypropylene water repellant

Head Sheet Size 1.25 x 1.6 m

Adhesive strip 4 cm x 1.5 mU Sheet Size 2 x 1.5 mU cut 2 cm x 15 cm Straight & 16 cm round

Poly sheet lining 1.2 x 1.2 mt

SHOULDER U DRAPE INT I522

Material : 68-77 gsm spun lace fabric water repellant

Head Sheet Size 0.1.50 x 2.40 m

Adhesive strip 4 cm x 2.40 m

U Sheet Size 2.50 x 2.40 mU cut 2 cm x 25 cm Straight & 16 cm round 2 Tube & Cable holders

Absorbent work pads 50 x 10 cm (2 nos)

Poly sheet lining 1.2 x 1.2 mt

Dra

pe

s

17 18

Knee Arthroscopy Drape Shoulder and Cling Drape

Uses: For endoscopic surgery in Knee joint

ARTHROSCOPY DRAPE D508

Material : 65-77 gsm spun lace fabric water repellant

Over all Size 150 x 280 cmElastic Aperture 5 cm dia

Plastic film Funnel 80 cm perimeter 60 cm depth

ARTHROSCOPY DRAPE E518

Material : 40-50 gsm SMS polypropylene water repellant

Over all Size 150 x 280 cmElastic Aperture 5 cm dia

Plastic film Funnel 80 cm perimeter 60 cm depth

ARTHROSCOPY DRAPE !528

Material : 65-77 gsm spun lace fabric water repellant

Over all Size 200 x 340 cmElastic Aperture 5 cm dia

Plastic film Funnel 80 cm perimeter 60 cm depth

Hold drape as per direction shown

Place it on patient’s body

Unfold drape on patient Keep on unfolding till the funnel is visible

Take out leg through elastic aperture

Cling Drape

Uses: For use to cover end of extremities during operation the skin and landmarks are visible.

CLING DRAPE CD01

Material: Transparent Natural color cling film

Size: 15 x 500 cm

Shoulder Arthroscopy Drape D509

Adhesive

Material : 65-77 gsm spun lace fabric water repellantOver all Size 160 x 190 cm 1 sheets 160 x 210 cm 1 sheetsPlastic film Funnel 1 Perimeter 90 cm 70 cm height with adhesive nozzle and bendable wires qty 2 funnels

19 20

Disposable DrapesDisposable Drapes

Lamino-Spinal Drape

Dis

po

sab

le D

rap

es

Unique features of disposable drapes from SURGIWEAR

1. Almost all special drapes are made of 2 layers. Top layer is of non woven fabric and bottom layer is of plastic sheet. Top layer gives surgeon a comfortable feel and soft draping whereas the bottom layer gives complet protection from fluid penetration. Most of special drapes giveyou level 4 protection as per ANSI/AAMI standards and High performance critical area protectionas per Europen Union standards.

2. The thread used to sew the drapes is coated with water repellant coating. It resists passage of fluid from patient to surgeon's side & vice versa.

Normal absorbent thread absorbing ink and passing to other side.

3. Holes in drapes are cut using laser. Laser makes very clean cut holes without fraying of edges.

5. Drapes are made in controlled environment. Lesser chances of foreign body contamination.

4. Drapes are made on automatic machines.

This drape is used for all kind of Spinal surgeries & Laminectomies etc.

Level 4 protection as per ANSI/AAMI Standards. High performance critical area protection as per European Union standards.

Lamino Spinal Drape D106

Material : 68-77 gsm spun lace fabric water repellant

Sheet Size 1.5 x 3 mIncise Sheet 15 x 35 cm 2 pockets 12 x 35 cm1 Tube & Cable holderswork pad 2no. 10x50 cm Poly sheet lining 1.20 x 1.20 m

Lamino Spinal Drape ECO E116

Material : 50 gsm SMS polypropylene water repellant Sheet Size 1.5 x 3 mIncise Sheet 15 x 35 cm Poly sheet lining 1.20 x 1.20 m

Lamino Spinal Drape INT I126

Material : 68-77 gsm spun lace fabric water repellant

Sheet Size 3.1 x 2.4 mIncise Sheet 15 x 35 cm Poly Sheet Lining 1.20 x 1.20 mt 2 pockets 12 x 35 cm1 Tube & Cable holderswork pad 2 no. 10x50 cm

240 cm

340 c

m

Lamino Spinal Drape Poly P1006

Material: Polymer sheet

Size 220 x 320 cmIncise area 15 x 35 cm

Work pad 35 x 55 cm, tube & cable holder

21 22

Disposable DrapesDisposable Drapes

www.surgiwear.co.in

Video Camera / cable Drape

T

Patent in India PendingTrade mark registration in India pending

S MPSERTSimpsertvideo camera cable coverUltrasound cover

Length 2.5 m width 15 cmVideo camera cable cover D904

Per-operative ultrasound cover D905

Head & Eye ShieldTo protect operating team from infections of patient

Head & Eye Shield D804

E214L 125 x 200cm with three pair eye lens cover

E214M 100 x 160 cmwith two pair eye lens cover

E214S 90 x 120 cmwith one pair eye lens coversupplied sterile ready to use.

O-Scope DrapeOpera�ng Microscope drape

C-Arm Covertwo part D306-2three part D306-3

Full C-Arm coverD307

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

SURGIW

EAR

Dis

po

sab

leD

rap

es

23 24

Disposable DrapesPlain Drape

Disposable DrapesPortable CT Drape

Portable CT Drape

For covering Portable CT machine for per-operative CTScan

PCT Drape D205

For covering incision area in all kind of surgeries Iodine adhesive coated (45 GSM approx) PU film

Code Size AdhesiveNumber Area

Id1010 15 X 10 CM 10 X 10 CM

ID1020 15 X 20 CM 10 X 20 CM

ID6025 90 X 25 CM 60 X 25 CM

ID3025-2 50 X 25 CM 30 X 25 CM

ID3535-2 50 X 35 CM 35 X 35 CM

ID6045-2 90 X 45 CM 60 X 45 CM

ID6060-2 90 X 60 CM 60 X 60 CM

ID6090-2 120 X 60 CM 90 X 60 CM

Iodrape-2Adhesive with Povidone Iodine

Baby Drape

For all kind of surgeries on babyalso used as low cost drape

Translucent soft polyfilm Size 1.2 x 1.2 m incise area 25 x 20 cmBaby Drape D201

For Covering patient body & instrument trolleys during surgery

Plain drapes

Gowns

Product Product Size Name Code

Material: 25 micron thick PE hygiene film

Plain Sheet Small D300 150X120 cm Plain Sheet D301 210X120 cm Plain Towel D303 66X120 cm Mayo's Trolly Cover S D304 120X66 cmMayo's Trolly Cover L D305 110X125 cm

Material: Spun bond NW 40gsm laminated with PE 20gsm

Plain Sheet small NW E310 150X120 cmPlain Sheet NW E311 120X150 cm Plain Towel NW E313 120X75 cm

Material: SMS Polypropylene Water repellant 50 gsm

Mayo's Trolly Cover Small NW E314 130X75 cm

Mayo's Trolly Cover Large NW E315 150X123 cm

Material: Spun lace Non woven Neo natal sheet D504 75 X 80 cm

Material: Spun lace Non woven laminated with PE 60 gsm

Plain Sheet Int I321 210X120 cm Plain Sheet Small Int I323 120X75 cm Plain Towel Int I327 60X75 cm

Product Code Material Protection level

Half gown D800 Polyethylene 25micron ---- Half gown D810 White non Woven 25 gsm ----

Full gown D802S Spun lace NW Level 2 D802M 65-77 gsm D802L

Full gown E812S NW SMS Level 1

Eco E812M 50gsm E812L

Full gown D806S Ahlstorm's Level 4

Viral barrier D806M BVB fabric D806L

Ÿ BVB means “Breathable Viral Barrier”

Ÿ All non woven fabrics are water repellent

Ÿ All full gowns are wrap around gowns and come with 2 nos hand towels

Ÿ Spun lace NW and BVB non woven gowns have bonded sleeves for extra protection, First time in the world.

Ÿ All full gown have patented “FLUBA” fluid barrier cuffs for extra protection

Dis

po

sab

leD

rap

es

25 26

Disposable DrapesPlain Drape

Disposable DrapesSpecial features of gowns

Chipko Gown

SURGIWEAR brings to you a new concept in Surgical Gowns "Chipko Gown". This is tie free gown. You don't have to tie the gown. In place of it just press the tie ends to gown. Your gown is secured. For removing the gown, you don't have to untie the gown. In place of it just pull the tie and will be unlocked from the gown.

Collar strap closure

Back strap applica�on

Front strap applica�on

By using Chipko gown, you will be saving at least 2 minutes of your time in OT.

Fluba cuff

Kni�ed cuff allows passageof fluid to other side of cuff

FLUBA cuff FLUBA cuff does not allow passage of fluid to other side of cuff

It saves you from deadly diseases such HIV and hepatitis C by preventing passage of patients fluid to other side of cuff.

Water repellant thread

SURGIWEAR uses water repellant thread. It resists passage of fluid from patient to surgeons side vice versa.

Normal absorbent thread absorbing ink and passing to other side.

Bonded sleeves

Sleeves of our D range and VB gowns are not stitched but bonded with adhesive. So the sleeve will not have needle holes providing you protection with higher rating.

* This Mask allows “Free passive ventilation”* The transparent part remains away from face to avoid fogging of vision* No direct ingress of contamination

Head & eye Shield

Design Registration and patent in India pending

1. First of button together twoflaps to make it a band

2. Hold the strings of face mask wear it.

3. Wear face mask properly. One string above ears second below jaw

4. Pinch the nose clip with force to make it fit face contour

5. Now you can wear your specs. 6. Hold the cloth cover andapply on head

7. Straighten side wire ribs.

27 28

Drape Kits for Orthopaedic Surgery

Bilateral Knee O Drape Kit DK5052

240cm

34

0cm

OT Table Sheet160 x 210cm 1 No.

Patient Chest Sheet160 x 75cm 1No.

Feet Holder2 No.

2 No. WaterproofLeggingLWP01

Cling Drape 2 nos.

Under Leg Drape160 x 160cm 1 No.

Sponge Stick2 No.

Bilateral Knee O Drape1 No

Non Stick Mesh30 x 40cm

2 No

Zf0122 x 22 cm

2 No.

Saddle Bag30 x 150cm

01 No.

Disposel Bag80 x 100cm

01 No.

E812M2 No

Unilateral Knee O Drape Kit DK5050

240cm

34

0cm

OT Table Sheet160 x 210cm 1 No.

Patient Chest Sheet160 x 75cm 1No.

Feet Holder1 No.

1 No. WaterproofLeggingLWP01

Cling Drape 1nos.

Under Leg Drape160 x 160cm 1 No.

Sponge Stick1 No.

Unilateral Knee O Drape1 No

Non Stick Mesh30 x 40cm

1 No

Zf0122 x 22 cm

1 No.

Saddle Bag30 x 150cm

01 No.

Disposel Bag80 x 100cm

01 No.

E812M2 No

Dra

pe

Kit

s

29 30

THR Drape Kit DK5011240cm

34

0cm

OT Table Sheet160 x 210cm 1 No.

Patient Chest Sheet160 x 75cm 1No.

Feet Holder1 No.

1 No. WaterproofLeggingLWP01

Cling Drape 1nos.

Under Leg Drape160 x 160cm 1 No.

Sponge Stick1 No.

Non Stick Mesh30 x 40cm

1 No

Zf0122 x 22 cm

1 No.

Saddle Bag30 x 150cm

01 No.

Disposel Bag80 x 100cm

01 No.

E812M2 No

Hip O Drape Poly P50001 No.

G-Kit Premium K004P

Goggle 01 No.Nitrile Gloves 01 Pair

Mask 01 No.Cap 01 No.1 Pair. WaterproofLegging

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEAR

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEAR

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEAR

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEAR

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSU

RGIW

EAR

SURG

IWEAR

SURG

IWEAR

SURG

IWEAR

SURG

IWEAR

SURG

IWEAR

Plain Sheet Large2 No.

Disposable Bag 1 No.

Medium Size gown1No

Viral Barrier Kit K007

1 Pair. WaterproofLegging

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEAR

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEAR

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEAR

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEAR

SURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSURGIWEARSU

RGIW

EAR

SURG

IWEAR

SURG

IWEAR

SURG

IWEAR

SURG

IWEAR

SURG

IWEAR

Plain Sheet LargeD300 1 No & D301No.

Disposable Bag 1 No.

Viral BarrierMedium Size gown

1No

1 PairLegging NW

Head & eye shield1No

4x2 Drape Sheet set 35 gsm fabric 35EK01850 gsm fabric 50EK018Non woven fabric drape sheets70 x 75 cm with adhesive strip on one side qty 4 No160 x160 cm plain 2 No

Gown Set Eco 02Medium size gowns 2 NoDK-GE02

Gown set Eco 03Medium size gown 3 NoDK-GE03

Gown set Eco 04Medium size gown 4 NoDK-GE04

Gown Set Eco 06 Medium Size gown 6 NoDK-GE06

Gown Set 02Medium size gowns 2 NoDK-G02

Gown set 03Medium size gown 3 NoDK-G03

Gown set 04Medium size gown 4 NoDK-G04

Gown Set 06 Medium Size gown 6 NoDK-G06

Drape SetsPE Gloves 01 Pair Mask 01 No.Cap 01 No.1 Pair. Waterproof

Legging

G-Kit K004

Medium Size gown1No

Paper Hand Towel

Paper Hand Towel

Paper Hand Towel

Drape Kits for Orthopaedic SurgeryDrape Kits for Orthopaedic Surgery

Dra

pe

Kit

s

31 32

"Zero-F" MopZero Fiber Mop

Zero Fibre Mop

SURGIWEAR has brought an ultra new concept for surgeons “Zero-F Mop” for surgeries. Conventional surgical mops are made of multi layers of gauze stitched on sides or similar material. These mops are made of cotton fibre threads. During use cotton fibres (lint) are shed on the wound surface and on the organs touched by the mops. These fibres can lead to multiple types of problems such as nidus for infection, fibre granuloma, foreign body reactions, fever & other related problems. In “Implant surgery” these fibres can increase risk & complications associated with the implant. In Neurosurgery these fibres may cause epilepsy & other problems.

One may ask why these problems were not observed or noticed. There are always some post –operative problems. Some of these problems can be traced to these fibres inside the body. You will find the difference in results after use.

ADVANTAGES

* No loose fibres to shed. Therefore zero linting.

* Zero-F mop is smooth it will not damage surface of organs and tissue.

* Zero-F MOP is radio opaque. During the manufacturing process, a radio opaque thread containing Barium sulphate is added to make it radio-opaque. This quality will help surgeon to identify any lost sponges.

DESCRIPTION

Zero-F mop is the answer to the problems due to fibres. It is made of filament yarn and sides are bonded by a special process. Even the handle is made of filament yarn only. Stitching is also done with filament yarn thread. During use hardly any fibre will be shed, because there is no loose fibre to shed. The mop carries a radio-opaque marker too. So, the mops can be detected on x-ray. Zero-F mop has a very good water absorbency.

PRECAUTION

* Zero-F Mop is meant for single use only.

PRESENTATION

Supplied in peel open pouches, ready to use & sterilized by EO

Product Name Code Size

Zero-F Mop Extra Large ZF00 30 x 30 cm

Zero-F Mop Large ZF01 22 x 22 cm

Zero-F Mop Medium ZF02 22 x 11 cm

Zero-F Mop Small ZF03 11 x 11 cm

Non woven mops / spongesto mop the blood

White Mop

Cotton Mops are used in all kind of surgical operations. Conventionally mops are made of surgical cotton gauge. The biggest disadvantages with these mops, is that these carry chemicals used during manufacturing process. Moreover recycled mops carry protein debris of last operation and all the chemicals used by washer man during washing.

SURGIWEAR has developed WHITE MOP surgical sponges. Specially designed for surgeons, for almost every kind of surgery. It will keep your patient's wound free from chemicals.

ADVANTAGES

Ÿ WHITE MOP is chemical free. No unwanted chemicals will go into the wound.

Ÿ WHITE MOP is less linting during surgery. Their use will minimize fiber granulomas, post operative infections due to foreign body reaction to shredded fibers.

Ÿ WHITE MOP is radio opaque. During the manufacturing process, a radio opaque thread containing Barium sulphate is added to make it radio-opaque. This quality will help surgeon to identify any lost sponges.

Ÿ WHITE MOP is super absorbent. The rate of absorption is very fast.

Ÿ WHITE MOP is meant for single use only.

PRECAUTIONS DURING USE

WHITE MOP should be moistened before use. Avoid rubbing it on rough surface.

Presentation:Supplied in peel open pouches, ready to use & sterilized by EO

Material : Non woven spun lace perforated 100 %, cotton of approx 40 gsm

Product Name Code Size

White Mop WM101 45 x 30 cm Extra Large

White Mop Large WM102 30 x 20 cm

White Mop Medium WM103 25 x 17 cm

White Mop Small WM104 20 x 15 cm

White Mop WM105 15 x 12 cmExtra Small

White Mop Patch WM106 12 x 10 cm

White Mop Stripe WM107 4 x 15 cm

General Surgery Set Large WM001

General Surgery Set Medium WM002

General Surgery Set Small WM003

Neuro Surgery Set Large WM011

Neuro Surgery Set Small WM012

Surg

ical

Mo

ps

33 34

Wound Dressings Wound Dressings

G-Dress comfy

G-Dress comfy is made of wide apertured non woven. It is lightly stretchable in both directions. The feel is soft & comfortable due to light stretch-ability. It is water repellent. Everyday spills will not spoil the dressing.

The wound pad is covered with non stick lining. It will prevent sticking of pad with wound.

Coated with skin friendly acrylic adhesive.

Size Pad size code Pack

6x5 cm 2x3 cm GD5 25 nos8.5x6.5 cm 3x5 cm GD10 10 nos14x7 cm 3x10 cm GD15 10 nos20x10.5 cm 4x16 cm GD20 10 nos25x10.5 cm 4x21 cm GD25 10 nos30x10.5 cm 4x26 cm GD30 10 nos

G-Dress Swimproof

G-Dress swimproof is made of SMS nonwoven. Middle layer of this non woven fabric resists passage of fluid. It makes the dressing water resistant. Everyday bathing will not spoil the dressing.

Regular breathing of skin & passage of water vapour is not prevented.This dressing is non stretchable.

The wound pad is covered with non stick lining. It will prevent Sticking of pad with wound.

Coated with skin friendly adhesive.

Size Pad size code Pack

6x5 cm 2x3 cm GDSP5 25 nos8.5x6.5 cm 3x5 cm GDSP10 10 nos14x7 cm 3x10 cm GDSP15 10 nos20x10.5 cm 4x16 cm GDSP20 10 nos25x10.5 cm 4x21 cm GDSP25 10 nos30x10.5 cm 4x26 cm GDSP30 10 nos

G-Dress flexi

G-Dress flexi is made of elastic non woven. It makes dressing stretchable along the length.On many parts of body it makes the dressing more comfortable and adoptable. Resists passage of fluid. Coated with skin friendly acrylic adhesive.

Size Pad size code Pack

6x5 cm 2x3 cm GDF5 25 nos8.5x6.5 cm 3x5 cm GDF10 10 nos14x7 cm 3x10 cm GDF15 10 nos20x10.5 cm 4x16 cm GDF20 10 nos25x10.5 cm 4x21 cm GDF25 10 nos30x10.5 cm 4x26 cm GDF30 10 nos

G-Dress silver is made of wound pad coated with nano silver layer. Silver is known bacteriostatic agent. It does not permit growth bacteria in its vicinity. Made with wide apertured non woven. Comfortable &soft. Coated with skin friendly acrylic adhesive.

Size Pad size code Pack

14x7 cm 3x10 cm GDS15 10 nos20x10.5 cm 4x16 cm GDS20 10 nos25x10.5 cm 4x21 cm GDS25 10 nos

G-Dress Silver

G-Dress Super absorbent

G-Dress Super absorbent has wound pad made of superabsorbent fibres. It can absorb water 20-30 times of its weight. It is very good for oozing wound or wounds with prolonged bleeding. The backing fabric is partially stretchable. Coated with skin friendly acrylic adhesive.

Size Pad size code Pack

8.5x6.5 cm 3x5 cm GDSA10 10 nos14x7 cm 3x10 cm GDSA15 10 nos20x10.5 cm 4x16 cm GDSA20 10 nos25x10.5 cm 4x21 cm GDSA25 10 nos C

lingb

and

Surg

ical

Mo

ps

36

Wound Dressings Miscellaneous products

IV Dressing swimproof IV Dressing Transparent

Non Stick Mesh

For covering large wound area in place of gauze.it will prevent sticking of dressing on wound surface

10x15 cm NM101515x25 cm NM152525x30 cm NM253025x50 cm NM2550

IV Dressing

IV Dressing swimproof

Made of non woven

Size Pad size code Pack

7x7 cm 1x1 cm IVDSP 10 nos

IV Dressing transparent

Made of polymer film

Size Pad size code Pack

7x7 cm 1x1 cm IVDT 10 nos

CLINGBAND

G-plast

To be used with drapes, it is non woven cloth band with adhesive. Being non woven it is highly conformable. It will take shape of area where applied. It also posses some stretchability in both directions.

It is highly comfortable and coated with skin friendly, moisture vapour permeable, hypo allergenic acrylic adhesive.

Available in 4 sizes with finger shaped release liner for easy removal of release liner.

G-Plast NT 225 2.5 cmG-Plast NT 525 5cmG-Plast NT 725 7.5 cmG-Plast NT 1025 10 cm

To be used with drapesAn ultrasoft and ultra comfortable non woven cloth band. It is elastic and self clinging. One layer clings on other layer. It will give user a feeling of high level of comfort & nice support. It is world's most comfortable cloth band.

CLINGBAND is very much suitable for joints and areas with movements. It will not come outor loosen from these areas due to its self clinging & elastic nature.

Available in two sizes 10 cm & 15 cm

CLINGBAND-10 10 x 250 cmCLINGBAND-15 15 X 250 CM

Clin

gban

d

37 38

UEM SplintUniversal Emergency Splint

Universal Emergency Splint

Surgiwear has developed an Universal Emergency Splint “UEM Splint”.In emergency situations it is to be used to support almost any part of limbs in straight or bent position. It provides enough rigidity for easy transportation with minimum movement of injured limb. It is easy to carry in small pouch of 28 cm length and weighs around 200 gm.

UEM Splint has two main parts A & B. Part A is 28 cm long with three strips and three hook & loop fastener straps. Part B is 18 cm long with three strips and two hook & loop fastener straps. Part A & B are joined with a bendable strip & a gap of 5 cm. Two movable side arms 21 cm long are attached with part B. Straps are made of hook & loop fastener.

To apply in angular position (Bent position / flexed position) first of all bend the splint at the bendable portion. Then move the side arms to attach with other part of the splint. Then apply hook & loop fastener flaps around the limb.

To apply the splint in straight position, make the splint straight. Move the side arm to straight position & attach with the second part of splint. Then apply the straps.

To apply UEM Splint on elbow, first bend the splint at the bendable part. Place the splint behind elbow. Keep small part against arm & large part against forearm. First tighten straps1 & 5. Now attache side arms to back of strap 4 on both sides of elbow as shown in picture. Now apply straps 2 3 & 4.

To apply UEM Splint on knee joint, first bend the splint at the bendable part. Place the splint behind the legkeep small part against thigh and large part against leg. First tighten straps 1 & 5. Now attach side arms to back of strap no. 3 on both sides of knee as shown in picture. Now apply straps 2, 3 & 4.

UEM Splint unfolded

position of UEM Splint for angular application

position of UEM Splint for straight application

Use of UEM splint for elbow application

Side strips

1

2

3 4

5

Part A

Part B

UEM Splint for stabilizing of knee joint

1 2

3

4

5

To apply UEM Splint on ankle joint, first bend the splintat the bendable part. Place the splint behind the leg keep small part against foot and large part against leg. First tighten straps 1 & 5. Now attach side arms to back of strap no. 3 on both sides of knee as shown in picture. Now apply straps 2, 3 & 4.

To apply the splint in straight position on leg, make the splint straight. Move the side arms to straight position & attach with the second part of splint. Then apply the straps.

If required more than one UEM splints can be used incircumferential position. It will strengthen the splintingand will provide greater support.

If required more than one UEM splints can be used to increase the length. The design of splints is such that these will stick together to make it one long splint and will provide longer support.

UEM Splint for support of ankle and foot

Patent in India pending

UEM SplintUniversal Emergency Splint

UEM

Sp

lint

39 40

Miscellaneous Devices

Sponge stick

With the help of sponge stick antiseptics and other part preparation agents can be applied easily and faster. The sponge has wide area for faster application. It can hold larger amount of antiseptic for wider application. The “Sponge Stick” is available in one size.

SPONGE STICK Code No. SS01

Stick 17 cm longSponge 5 x 5 x 2.5 cm.Each sponge stick is packed in peel open pouches individually sterilized by ETO.

During any surgery skin & parts are required to be marked. Surgiwear presents a very convenient solution DERMIMARKER. It is a skin marking pen.

Dermimarker is supplied sterile packed in peel open pouches with a flexible scale.

Dermimarker-1 (thin marking) INS071Dermimarker-2 (thick marking) INS072

Dermimarker

UEM

Sp

lint

41