AMPLIFIERS A circuit containing only capacitors, amplifiers ...
Product · Web viewLoad power supply voltage: 30 VDC max., open-collector outputLoad current:...
-
Upload
truongxuyen -
Category
Documents
-
view
216 -
download
0
Transcript of Product · Web viewLoad power supply voltage: 30 VDC max., open-collector outputLoad current:...
PRODUCTNEWS Product Discontinuation
Notices Issue DateMarch 1, 2018
Digital Fiber Sensor No. OMSQ-C (03)178127-EU
Discontinuation Notice of Digital Fiber Amplifier Unit E3X-DA-N Series.
Product Discontinuation Recommended ReplacementDigital Fiber Amplifier Unit Smart Fiber Amplifier Unit
E3X-DAH□E3X-DA□1-N 2M
E3X-DAB□E3X-DAG□E3X-DA□VE3X-DAT6-2E3X-DA7/9
E3NX-FAH□ SeriesE3NX-FA□1-AN 2M
Color Mark Fiber AmplifierE3NX-CA□ SeriesE3NX-CA□ Series
No recommended replacement
No recommended replacement
No recommended replacement
Final order entry dateThe end of March 2019
Date of The Last ShippingThe end of June 2019
Caution on recommended replacementWhen going to use E3NX-FA Series. Please pay attention to the following.1) The dimensions of sensor are different. Please refer to the dimensions for details.2) The operation methods are different. Please refer to operation methods for details.3) The characteristics are different. Please refer to characteristics and operation ratings for details.4) Notice that the position of output indicator is different.5) Control-output are different. Please refer to characteristics and operation ratings for details.6) Optical communication to E3NX-FA/CA series is not available. Notice that channel recognition and Mutual interference prevention is not available at communication status.7) Mobile console E3X-MC11 is not available.8) The Communication Unit E3X-DRT21、E3X-SRT21 and E3X-CIF11 cannot be connected.9)When using Fiber head E32-D61/D73/D81R/T61/T81R(D81R/T61/T81R are discontinued)series,
notice that the pitch between deliver and receiver hole is different compared with E3X-HD series, and installation is unavailable. Please also change the Fiber head to the following types.
E32-D61-S/D73-S/D81R-S/T61-S/T81R-S series.
When going to use E3NX-CA Series. Please pay attention to the following。1)E3X-DAB(blue)、E3X-DAG(green) can distinguish power with contrast mode.2) When using to distinguish several objects. Please to check whether each object can be distinguished.*Because of the difference of RGB turning, when there are several kinds of color, maybe it will be unable to distinguish.
OMRON Corporation Industrial Automation Company No. OMSQ-C (03)178127-EU
Difference from discontinued productRecommended
replacement ModelBody Color
Dimen-sions
Wire connection
Mounting Dimensions
Charac-teristics
Operation ratings
Operation methods
E3NX-FA Series * * ** ** * * *E3NX-CA Series * * ** ** * * *
** : Compatible* : The change is a little/Almost compatible-- : Not compatible- : No corresponding specification
Product Discontinuation and recommended replacementProduct discontinuation Recommended replacement
E3X-DAB11-N 2M E3NX-CA11 2ME3X-DAB6 E3NX-CA6E3X-DAB41-N 2M E3NX-CA41 2ME3X-DAB8 E3NX-CA8E3X-DAG6 E3NX-CA6E3X-DAG11-N 2M E3NX-CA11 2ME3X-DAG41-N 2M E3NX-CA41 2ME3X-DAG8 E3NX-CA8E3X-DAH11-N 2M E3NX-FAH11 2ME3X-DAH6 E3NX-FAH6E3X-DAH41-N 2M E3NX-FAH41 2ME3X-DAH8 E3NX-FAH8E3X-DA21-N 2M E3NX-FA11-AN 2ME3X-DA51-N 2M E3NX-FA41-AN 2ME3X-DA41V 2M No recommended replacementE3X-DAT6-2 No recommended replacementE3X-DA14V No recommended replacementE3X-DA44V No recommended replacementE3X-DA11V 2M No recommended replacementE3X-DA7 No recommended replacementE3X-DA9 No recommended replacement
2
Body colorProduct discontinuationModel E3X-DA-N Series
Recommendable replacementModel E3NX-CA SeriesModel E3NX-FA Series
Body(code type)E3X-DA-N Series
body:blackCover printing :orangeCase side:No printing
E3NX-FA Series /E3NX-CA Series
body:blackCover printing:silverCase side:black name plate with white printing
Operation panel
7-seg display:redOperation button:orangeOperation panel printing:orange
7-seg display:green+whiteOperation button:blackOperation panel printing:white
Cable
Cable:dark grey Cable:black
Dimensions
3
Product discontinuationModel E3X-DA-N Series
Recommendable replacementModel E3NX-CA SeriesModel E3NX-FA Series
Pre-wired Amplifiers
Amplifiers with Standard ConnectorsTwin-output Models
CharacteristicsMark-detecting models E3X-DAB□-N/E3X-DAG□-N
4
Product discontinuationModel E3X-DAB□-NModel E3X-DAG□-N
Recommendable replacementModel E3NX-CA□Series
5
Light source(wavelength)E3X-DAB□-N :Blue Led(470nm)
E3X-DAG□-N :Green Led(525nm)White LED (420 to 700 nm)
Power supply voltage 12 to 24 VDC±10%, ripple (p-p) 10% max.
10 to 30 VDC, including 10% ripple (p-p)
Power consumption(at power
supply voltage of 24VDC)
Normally mode 960mW max. 960mW max.Eco mode 720mW max 720mW max
Eco Lo mode - 800mW max.
Digital display not lit: 600mW max. -
Control output
Load current: 50 mA (residual voltage (NPN/PNP): 1 V max.,Open collector (NPN or PNP
output, depending on the model)Light ON/Dark ON selectable
Load power supply voltage: 30 VDC max., open-collector output
Load current: Groups of 1 to 3 Amplifiers: 100 mA max.,
Groups of 4 to 30 Amplifiers: 20 mA max.
Residual voltage: At load current of less than 10 mA: 1 V max.
At load current of 10 to 100 mA: 2 V max.
OFF current: 0.1 mA max.
Protection circuits
Power supply reverse polarity
protectionProvided Provided
Output short-circuit protection Provided Provided
Out reverse polarity protection Not provided Provided
Response time
Super-high-speed mode 0.25ms 50μs(Contrast Mode only)
High-speed Mode - 250μsStandard mode 1ms 1ms
Giga-power Mode - 16msSuper-long-distan
ce mode4ms -
Sensitivitysetting Teaching or manual method
Smart Tuning (2-point tuning,full auto tuning,
or 1-point tuning (1% to 99%)) or manual adjustment
Functions
Timer
OFF-delay timer: 0 to 200ms, 1 to 20ms (set in 1-ms units); 20 to
200ms (set in 5-ms units)Using Mobile Console: OFF delay, ON delay, or one shot (selectable)
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-delay +
OFF-delay timer (Countedby 0.1 s in a range of 0.1 to 0.5ms, by 0.5ms for 0.5 to 5ms, and by 1ms for 5
to 9999ms. Default: 10ms, Error: 0.1ms)
Zero-reset Negative values can be displayed.Contrast Mode only
Negative values can be displayed. (Threshold level is shifted.)
Initial-reset Settings can be returned to defaults as required. -
Operation mode -
Contrast Mode: NO (Light-ON) or NC (Dark-ON)
Color Mode: NO (ON for match: ON for same color as registered color) or
NC (ON for mismatch: ON fordifferent color from registered color)
Resetting settings -Select from initial reset (factory
defaults), user reset (saved settings), or bank reset.
eco mode - Select from OFF (digital display lit),
6
Eco ON (digital display not lit) Eco LO (digital display dimmed).
Bank switching - Select from banks 1 to 8.
power tuning level -
Set from 100 to 9,999. (The RGB maximum incident level at Smart
Tuning is adjusted to the power tuninglevel.)
changing the display -
Threshold level and incident level,Channel number and incident level,
RGB display and incident level,Bank display and incident level
No.of Units for mutual
interference prevention
10 UnitsHigh-speed Mode (HS):10 UnitsStandard Mode (Stnd):10 Units
Giga-power Mode (GIGA):10 Units
Indicators
Operation indicator (orange), 7-segment digital incident level
display (red), 7-segment digital incident level percentage
display (red), threshold and excess gain 2-color double bar indicators (green and red), 7-segment digital
thresholddisplay (red)
7-segment displays (Sub digital display: green, Main digital display:
white)Display direction: Switchable between normal and reversed. OUT indicator (orange), NO/NC indicator (orange), Smart Tuning indicator (blue), and
OUT selection indicator (orange, only on models with 2 outputs)
Display timing Switching between normal/peak-hold/bottom-hold possible -
Display orientation Switching between normal/reverse possible -
Optical axis adjustment Optical axis adjustment possible (hyper-flashing function) -
Ambient Illumination
(receiver side)
Incandescent lamp 10,000 lx max. 20,000 lx max
Sunlight 20,000 lx max 30,000 lx max
Ambienttemperature
Operating
Groups of 1 to 3 Amplifiers: −25 to 55°C
Groups of 4 to 11 Amplifiers:−25 to 50°C
Groups of 12 to 16 Amplifiers: −25 to 45°C
Groups of 1 or 2 Amplifier Units:−25 to 55°C,
Groups of 3 to 10 Amplifier Units:−25 to 50°C,
Groups of 11 to 16 Amplifier Units:−25 to 45°C,
Groups of 17 to 30 Amplifier Units: −25 to 40°C
Storage −30 to 70°C (with no icing or condensation)
−30 to 70°C (with no icing or condensation)
Weight(Packed
state)
Pre-wired(standard
cable length:2 m)100 g E3NX-CA11/E3NX-CA41:115g
Standard connector
55 g E3NX-CA6/E3NX-CA8:60g
MaterialCase Polybutylene terephthalate (PBT) Polycarbonate (PC)Cover Polycarbonate Polycarbonate
Cable covering - Polyvinyl chloride (PVC)Accessories Instruction sheet Instruction sheet
Infrared models E3X-DAH□Product discontinuation
Model E3X-DAH□Recommendable replacement
Model E3NX-FAH□Series
Light source(wavelength) Infrared LED(870 nm) Infrared LED (870nm)
Power supply voltage 12 to 24 VDC±10%, ripple (p-p) 10% max.
10 to 30 VDC, including 10% ripple (p-p)
Power Normally mode 960mW max 1080mW max
7
consumption(at power
supply voltage of 24VDC)
Eco mode 720mW max. 920mW maxEco Lo mode - 1020mW max
Digital display not lit: 600mW max. -
Control output
Load current: 50 mA (residual voltage (NPN/PNP): 1 V max.,Open collector (NPN or PNP
output, depending on the model)Light ON/Dark ON selectable
Load power supply voltage: 30 VDC max., open-collector output (depends
on the NPN/PNP output format)Load current: Groups of 1 to 3
Amplifier Units: 100 mA max., Groups of 4 to 30 Amplifier Units: 20 mA max.
Protection
circuits
Power supply reverse polarity protection Provided Provided
Output short-circuit protection Provided Provided
Out reverse polarity protection Not provided Provided
Response time
Super-high-speed mode 0.25ms 30μsHigh-speed Mode - 250μsStandard mode 1ms 1ms
Giga-power Mode - 16msSuper-long-distance mo
de4ms -
Sensitivitysetting Teaching or manual method
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning, or
percentage tuning (-99% to 99%)) or manual adjustment
Functions
Timer
OFF-delay timer: 0 to 200ms, 1 to 20ms (set in 1-ms units); 20
to 200ms (set in 5-ms units)Using Mobile Console: OFF delay, ON delay, or one shot
(selectable)
Select from timer disabled OFF-delay, ON-delay, one-shot, ON-delay + OFF-delay timer: 1 to
9,999ms
Automatic power control(APC) - Always enabled.
Zero-reset Negative values can be displayed.
Negative values can be displayed. (Threshold value is shifted.)
Initial-reset Settings can be returned to defaults as required. -
Resetting settings -Select from initial reset (factory defaults) or user reset (saved
settings).
eco mode -Select from OFF (digital display lit)
Eco ON (digital display not lit)Eco LO (digital display dimmed).
Bank switching - Select from banks 1 to 4.power tuning level - Select from ON or OFF.
Output 1 -Select from normal
detection mode or areadetection mode.
No.of Units for mutual interference prevention 10 Units
Super-high-speed mode(SHS):0 UnitsHigh-speed Mode (HS):10 UnitsStandard Mode (Stnd):10 UnitsGiga-power Mode (GIGA):10 Units
Indicators Operation indicator (orange), 7-segment digital incident level
display (red), 7-segment digital incident level percentage
display (red), threshold and excess gain 2-color double bar indicators (green and red), 7-
7-segment displays (Sub digital display: green, Main digital display:
white)Display direction: Switchable between
normal and reversed.OUT indicator (orange), L/D indicator
(orange), ST indicator (blue), DPC
8
segment digital thresholddisplay (red)
indicator (green),and OUT selection indicator (orange,
only on models with 2 outputs)
Display timing Switching between normal/peak-hold/bottom-hold possible -
Display orientation Switching between normal/reverse possible -
Optical axis adjustment Optical axis adjustment possible (hyper-flashing function) -
Ambient Illuminatio
n(receiver
side)
Incandescent lamp 10,000 lx max. 20,000 lx max
Sunlight 20,000 lx max. 30,000 lx max
Ambienttemperatu
re
Operating
Groups of 1 to 3 Amplifiers: −25 to 55°C
Groups of 4 to 11 Amplifiers:−25 to 50°C
Groups of 12 to 16 Amplifiers: −25 to 45°C
Groups of 1 or 2 Amplifier Units:−25 to 55°C,
Groups of 3 to 10 Amplifier Units: −25 to 50°C,
Groups of 11 to 16 Amplifier Units: −25 to 45°C,
Groups of 17 to 30 Amplifier Units: −25 to 40°C
Storage −30 to 70°C(with no icing or condensation)
−30 to 70°C(with no icing or condensation)
Weight(Packed
state)
Pre-wired(standard cable length:2 m) 100 g E3NX-FAH11/E3NX-FAH41:115g
Standard connector 55 g E3NX-FAH6/E3NX-FAH8:60g
MaterialCase Polybutylene terephthalate
(PBT) Polycarbonate (PC)
Cover Polycarbonate Polycarbonate (PC)Cable covering - PVC
Accessories Instruction sheet Instruction Manual
Standard models\ Monitor-output models E3X-DA□1-NProduct discontinuation
Model E3X-DA□1-NRecommendable replacement
Model E3NX-FA□1ANLight source(wavelength) Red LED (660 nm) Red, 4-element LED (625 nm)
Power supply voltage 12 to 24 VDC±10%, ripple (p-p) 10% max.
10 to 30 VDC, including 10% ripple (p-p)
Power consumptio
n(at power
supply voltage of
Normally mode 960mW max 960mW max.Eco mode 720mW max. 770mW max
Eco Lo mode - 870mW max.Digital display not lit: 600mW max. -
9
24VDC)
Control output
ON/OFFoutput
Load current: 50 mA (residual voltage (NPN/PNP): 1 V max.,Open collector (NPN or PNP
output, depending on the model)Light ON/Dark ON selectable
Load power supply voltage:30 VDC max., open-collector output(depends on the NPN/PNP output
format)Load current: Groups of 1 to 3
AmplifierUnits: 100 mA max., Groups of 4 to
30Amplifier Units:
20 mA max.Residual voltage:
At load current of less than 10 mA: 1 V max.
At load current of 10 to 100 mA: 2 V max.
OFF current: 0.1 mA max.
Monitoroutput
Standard models:Not providedMonitor output models:
Load 1 to5 VDC,10 kΩ min.
-
Protection circuits
Power supply reverse polarity
protectionProvided Provided
Output short-circuit protection Provided Provided
Out reverse polarity protection Not provided Provided
Response time
Super-high-speed mode 0.25ms 80 μs
High-speed Mode - 250μsStandard mode 1ms 1ms
Giga-power Mode - 16msSuper-long-distance
mode4ms -
Sensitivitysetting Teaching or manual method
Smart Tuning (2-point tuning, full auto tuning, position tuning, maximum sensitivity tuning, power tuning,
percentage tuning (−99% to 99%)) or manual adjustment
Functions
Timer
OFF-delay timer: 0 to 200ms, 1 to 20ms (set in 1-ms units); 20 to
200ms (set in 5-ms units)Using Mobile Console: OFF delay, ON delay, or one shot (selectable)
Select from timer disabled, OFF-delay, ON-delay, one-shot, or ON-
delay + OFF-delay timer: 1 to 9,999ms
Automatic power control(APC)
Fiber-optic current digitalcontrol Always enabled.
Zero-reset Negative values can be displayed. Negative values can be displayed. (Threshold value is shifted.)
Initial-reset Settings can be returned to defaults as required. -
Monitor focus
Standard models:Not providedMonitor output models:
Upper and lower limits can be set as required for every 100 digital
values
-
Resetting settings - Select from initial reset (factory defaults) or user reset (saved
10
settings).
eco mode -Select from OFF (digital display lit), Eco ON (digital display not lit), and Eco LO (digital display dimmed).
Bank switching - Select from banks 1 to 4.power tuning level - Select from ON or OFF.
No. of Units for mutual interference
prevention10 Units
Super-high-speed mode(SHS):0 UnitsHigh-speed Mode (HS):10 UnitsStandard Mode (Stnd):10 Units
Giga-power Mode (GIGA):10 Units
Output 1 - Select from normal detection mode or area detection mode.
Output 2 - Select from Analog scalingor Analog offset.
Hysteresis width- Select from standard setting or user
setting. For a user setting, the hysteresis width can be set from 0 to
9,999.
Indicators
Operation indicator (orange), 7-segment digital incident level
display (red), 7-segment digital incident level percentage
display (red), threshold and excess gain 2-color double bar indicators (green and red), 7-
segment digital thresholddisplay (red)
7-segment displays (Sub digital display: green, Main digital display:
white)Display direction: Switchable between
normal and reversed.OUT indicator (orange), L/D indicator
(orange), ST indicator (blue), DPC indicator (green),
and OUT selection indicator (orange, only on models with 2 outputs)
Ambient Illumination
(receiver side)
Incandescent lamp 10,000 lx max. 20,000 lx max.,
Sunlight 20,000 lx max. 30,000 lx max.
Ambienttemperature
Operating
Groups of 1 to 3 Amplifiers: −25 to 55°C
Groups of 4 to 11 Amplifiers:−25 to 50°C
Groups of 12 to 16 Amplifiers:−25 to 45°C
Groups of 1 or 2 Amplifier Units:−25 to 55°C,
Groups of 3 to 10 Amplifier Units: −25 to 50°C,
Groups of 11 to 16 Amplifier Units: −25 to 45°C,
Groups of 17 to 30 Amplifier Units: −25 to 40°C
Storage .−30 to 70°C (with no icing or condensation)
.−30 to 70°C (with no icing or condensation)
Ambient humidityOperating and storage: 35% to
85% (with no condensation)
Operating and storage: 35 to 85% (with no condensation) within the
surrounding air temperature range shown above
Insulation resistance 20 MΩ min. (at 500 VDC) 20 MΩ min. (at 500 VDC)Dielectric strength 1,000 VAC at 50/60 Hz for 1 min 1,000 VAC at 50/60 Hz for 1 min
Vibration resistance(destruction)
10 to 55 Hz with a 1.5-mm double amplitude for 2 h each in X, Y and
Z directions
10 to 55 Hz with a 1.5-mm double amplitude for 2 hours each in X, Y,
and Z directions
Shock resistance(destruction)
500m/s2, for 3 times each in X, Y and Z directions
500 m/s2 for 3 times each in X, Y, and Z
directions
degree of protection IEC IP50 (with Protective Cover attached)
-
Weight(Packed
state)
Pre-wired(standard cable length:2 m) Approx. 100 g Approx. 115 g
MaterialCase Polybutylene terephthalate (PBT) Polycarbonate (PC)Cover Polycarbonate Polycarbonate (PC)
11
Cable covering - PVCAccessories Instruction sheet Instruction Manual
Operation ratingsProduct discontinuationModel E3X-DA-N Series
Recommendable replacementModel E3NX-FA SeriesModel E3NX-CA Series
Sensing distance Sensing distance
Operation methods
12
Product discontinuationModel E3X-DA-N Series
Recommendable replacementModel E3NX-CA SeriesModel E3NX-FA Series
E3NX-CA Series
E3NX-FA Series
Specifications and prices in this product news are as of the issue date and are subject to change without notice.Only main changes in specifications are described in this document. Please be sure to read the relevant catalogs, datasheets, product specifications, instructions, and manuals for precautions and necessary information when using products.
13