FirstLine PL
Staco Energy Products Co.
10kVA / 9kW15kVA / 13.5kW20kVA / 18kW30kVA / 27kW40kVA / 36kw
Emergency Lighting SystemUL924
924
PL 924, 9kW Models
Part Number kW Input/Output
Description DimensionsH x W x D (inches)
Wt.(lbs.)
# of Cabs.
208 X 208 9 FLP-924-09
9
208Y/120208Y/120
10kVA/9kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet
Electronics: 47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 35.55
2,600
2
FLP-924-09M
9
208Y/120208Y/120
10kVA/9kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) Wall Mount Bypass
Electronics:47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 35.55Wall Mt. Bypass: 22.2 x 18.25 x 12.7
2,615
2
480 X 480 FLP-924-09-44
9
480Y/277480Y/277
10kVA/9kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) 4 x 4 Transformer Cabinet
Electronics: 47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 35.55Transformer: 43 x 27 x 34
2,900
3
FLP-924-09-44M
9
480Y/277480Y/277
10kVA/9kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) 4 x 4 Transformer Cabinet with Bypass
Electronics: 47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 35.55Transformer w/ Bypass: 43 x 27 x 34
2,915
3
480 X 208 FLP-924-09-42
9
480Y/277208Y/120
10kVA/9kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) 4 x 2 Transformer Cabinet
Electronics: 47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 35.55Transformer: 43 x 27 x 34
2,750
3
FLP-924-09-42M
9
480Y/277208Y/120
10kVA/9kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) 4 x 2 Transformer Cabinet with Bypass
Electronics: 47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 35.55Transformer w/ Bypass: 43 x 27 x 34
2,765
3
PL 924, 13kW Models
Part Number kW Input/Output
Description DimensionsH x W x D (inches)
Wt.(lbs.)
# of Cabs.
208 X 208 13.5 FLP-924-13
13.5
208Y/120208Y/120
15kVA/13.5kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet
Electronics: 47.07 x 20.29 x 32.95Battery: 60.16 x 26.3 x 35.58
2,850
2
FLP-924-13M
13.5
208Y/120208Y/120
15kVA/13.5kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) Wall Mount Bypass
Electronics: 47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 33.55Wall Mt. Bypass: 22.2 x 18.25 x 12.7
2,865
2
480 X 480 FLP-924-13-44
13.5
480Y/277480Y/277
15kVA/13.5kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) 4 x 4 Transformer Cabinet
Electronics: 47.07 x 20.29 x 32.95Battery: 60.16 x 26.3 x 35.58Transformer: 43 x 27 x 34
3,150
3
FLP-924-13-44M
13.5
480Y/277480Y/277
15kVA/13.5kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) 4 x 4 Transformer Cabinet with Bypass
Electronics: 47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 33.55Transformer w/ Bypass: 43 x 27 x 34
3,165
3
480 X 208 FLP-924-13-42
13.5
480Y/277208Y/120
15kVA/13.5kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) 4 x 2 Transformer Cabinet
Electronics: 47.07 x 20.29 x 32.95Battery: : 60.16 x 26.3 x 35.58Transformer: 43 x 27 x 34
3,300
3
FLP-924-13-42M
13.5
480Y/277208Y/120
15kVA/13.5kW Electronics Module with (1) String of batteries internal, (1) String in (1) External Cabinet and (1) 4 x 2 Transformer Cabinet with Bypass
Electronics: 47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 33.55Transformer w/ Bypass: 43 x 27 x 34
3,315
3
PL 924, 18kW Models
Part Number kW Input/Output
Description DimensionsH x W x D (inches)
Wt.(lbs.)
# ofCabs.
208 X 208 18 FLP-924-18
18
208Y/120208Y/120
20kVA/18kW Electronics Module, no internal batteries, (2) Strings in (1) External Cabinet
Electronics: 47.07 x 20.29 x 32.95Battery: 71.58 x 37.75 x 37.86
4,050
2
FLP-924-18M
18
208Y/120208Y/120
20kVA/18kW Electronics Module, no internal batteries, (2) Strings in (1) External Cabinet and (1) Wall Mount Bypass
Electronics: 47.07 x 20.29 x 32.95Battery: 51.42 x 26.12 x 33.55Ext. Wall Mt. Bypass: 22.2 x 18.25 x 12.7
4,065
2
480 X 480 FLP-924-18-44
18
480Y/277480Y/277
20kVA/18kW Electronics Module, no internal batteries, (2) Strings in (1) External Cabinet and (1) 4 x 4 Transformer Cabinet
Electronics: 47.07 x 20.29 x 32.95Battery: 71.58 x 37.75 x 37.86Transformer: 43 x 27 x 34
4,400
3
FLP-924-18-44M
18
480Y/277480Y/277
20kVA/18kW Electronics Module, no internal batteries, (2) Strings in (1) External Cabinet and (1) 4 x 4 Transformer Cabinet with Bypass
Electronics: 47.07 x 20.29 x 32.95Battery: 71.58 x 37.75 x 37.86Transformer with Bypass: 43 x 27 x 34
4,400
3
480 X 208 FLP-924-18-42
18
480Y/277208Y/120
20kVA/18kW Electronics Module, no internal batteries, (2) Strings in (1) External Cabinet and (1) 4 x 2 Transformer Cabinet
Electronics: 47.07 x 20.29 x 32.95Battery: 71.58 x 37.75 x 37.86Transformer: 43 x 27 x 34
4,400
3
FLP-924-18-42M
18
480Y/277208Y/120
20kVA/18kW Electronics Module, no internal batteries, (2) Strings in (1) External Cabinet and (1) 4 x 2 Transformer Cabinet with Bypass
Electronics: 47.07 x 20.29 x 32.95Battery: 71.58 x 37.75 x 37.86Transformer with Bypass: 43 x 27 x 34
4,200
3
PL 924, 27kW Models
Part Number kW Input/Output
Description DimensionsH x W x D (inches)
Wt.(lbs.)
# ofCabs.
208 X 208 27
FLP-924-27
27
208Y/120208Y/120
30kVA/27kW Electronics Module, no internal batteries, (3) Strings in (2) External Cabinets
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86
6,120
3
FLP-924-27M
27
208Y/120208Y/120
30kVA/27kW Electronics Module, no internal batteries, (3) Strings in (2) External Cabinets and (1) Wall Mount Bypass
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Wall Mt. Bypass: 22.2 x 18.25 x 12.7
6,135
3
480 X 480
FLP-924-27-44
27
480Y/277480Y/277
30kVA/27kW Electronics Module, no internal batteries, (3) Strings in (2) External Cabinets and (1) 4 x 4 Transformer Cabinet
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Transformer: 51.4 x 27 x 34
6,520
4
FLP-924-27-44M
27
480Y/277480Y/277
30kVA/27kW Electronics Module, no internal batteries, (3) Strings in (2) External Cabinets and (1) 4 x 4 Transformer Cabinet with Bypass
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Transformer: 51.4 x 27 x 34
6,536
4
480 X 208
FLP-924-27-42
27
480Y/277208Y/120
30kVA/27kW Electronics Module, no internal batteries, (3) Strings in (2) External Cabinets and (1) 4 x 2 Transformer Cabinet
Electronics: 52 x 23.15 x 32.95 Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Transformer: 51.4 x 27 x 34
6,270
4
FLP-924-27-42M
27
480Y/277208Y/120
30kVA/27kW Electronics Module, no internal batteries, (3) Strings in (2) External Cabinets and (1) 4 x 2 Transformer Cabinet with Bypass
Electronics: 52 x 23.15 x 32.95 Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Transformer: 51.4 x 27 x 34
6,285
4
PL 924, 36kW Models Part Number kW Input/
OutputDescription Dimensions
H x W x D (inches)Wt.
(lbs.)# of
Cabs.208 X 208 36 FLP-924-36
36
208Y/120208Y/120
40kVA/36kW Electronics Module FLP-040-0, no internal batteries, (4) Strings HR12200 in (2) External CabinetFLP-BAT-100-200-2-B & FLP-BAT-100-200-2-N
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86
7,850
3
FLP-924-36M
36
208Y/120208Y/120
40kVA/36kW Electronics Module FLP-040-0, no internal batteries, (4) Strings HR12200 in (2) External CabinetFLP-BAT-100-200-2-B & FLP-BAT-100-200-2-Nand (1) Floor Mount BypassFLP-040-MBPS
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Floor Mt. Bypass: 61.6 x 16 x 33.6
7,865
4
480 X 480 FLP-924-36-44
36
480Y/277480Y/277
40kVA/36kW Electronics Module FLP-040-0 , no internal batteries, (4) Strings HR12200 in (2) External CabinetFLP-BAT-100-200-2-B & FLP-BAT-100-200-2-Nand (1) 4 x 4 Transformer Cabinet FLP-040-TC-4Y-4Y
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Transformer: 51.4 x 27 x 34
8,250
4
FLP-924-36-44M
36
480Y/277480Y/277
40kVA/36kW Electronics Module FLP-040-0 , no internal batteries, (4) Strings HR12200 in (2) External CabinetFLP-BAT-100-200-2-B & FLP-BAT-100-200-2-Nand (1) 4 x 4 Transformer Cabinet with Bypass FLP-040-TC-4Y-4Y-MBPS
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Transformer with Bypass: 51.4 x 27 x 34
8,400
4
480 X 208 FLP-924-36-42
36
480Y/277208Y/120
40kVA/36kW Electronics Module FLP-040-0 , no internal batteries, (4) Strings HR12200 in (2) External CabinetFLP-BAT-100-200-2-B & FLP-BAT-100-200-2-Nand (1) 4 x 2 Transformer Cabinet FLP-040-TC-4Y-2Y
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Transformer: 51.4 x 27 x 34
8,050
4
FLP-924-36-42M
36
480Y/277208Y/120
40kVA/36kW Electronics Module FLP-040-0 , no internal batteries, (4) Strings HR12200 in (2) External CabinetFLP-BAT-100-200-2-B & FLP-BAT-100-200-2-Nand (1) 4 x 2 Transformer Cabinet with BypassFLP-040-TC-4Y-2Y-MBPS
Electronics: 52 x 23.15 x 32.95Battery #1:71.58 x 37.75 x 37.86Battery #2:71.58 x 37.75 x 37.86Transformer with Bypass: 51.4 x 27 x 34
8,065
4
PL Multi-Functional ELS
220/127VAC ApplicationThe UPS shall be configured for 220/127VAC Input & Output from the Front Panel or Factory set.Part Number EXAMPLE: FLP-XXX (kVA)-X (Model)-220
Factory set for PARALLEL OperationThe UPS shall be factory set for paralleling up to 4 UPS Modules.Part Number EXAMPLE: FLP-XXX (kVA)-X (Model)-PAR
PL Unique Features
Automatic RestartUpon restoration of utility AC power after a power outage, the rectifier shall automatically restart and resume the inverter and battery recharge loads. Functional only on units with batteries.
220/127VAC ApplicationCan be configured for 220/127VAC Input & Output from the Front Panel
Adaptive Feed CancellationUses AFC Technology that provides advanced control with AFC forward cancellation circuit for low harmonic distortion.
Standard Major Components
Rectifier complete with power factor correctionHeavy Duty Battery ChargerPWM Inverter utilizing IGBT’s (Insulated Gate Bipolar Transistor) Continuous duty rated Static SwitchInput Isolation Switch Output Isolation Switch Maintenance Isolation Switch Bypass Isolation Switch DSP Control and Monitoring Panel with Graphic displayParallel Circuit SNMP Communication Card with Shutdown/Monitoring Software, Remote monitoring with RS 232 Serial Port and Type A
Contacts and MODBUS standard.Internal Maintenance Bypass
AC Input Characteristics
Nominal Voltage: 208Y/120 VAC, 3 Phase, 4-wire + ground (Standard Voltage) or
220/127VAC configurable from the Front Panel or
480Y/277 VAC, 3 Phase, 3 or 4-wire + ground - with external line upand match K20 – Shielded transformer cabinet (Optional).
Nominal Voltage Range: +15/-20% Frequency: 50/60Hz, +/- 5.0HzPower Factor: > 0.99 at full load, 0.98 minimum at 50% load.Current Harmonic Distortion (THDi): < 1% at full load, <2% at 50% load and <5% at 10% load.Inrush current: Less than nominal input current for less than one cycle.Input Surge Protection: UPS shall be equipped to withstand surges per ANSI/IEEE C62.41.Rectifier Walk-in: Input current shall ramp up from 25% to 100% over 5 seconds.
AC Output Characteristics
Voltage: 208Y/120 VAC, ± 2% steady state variation phase-to-phase voltage volts AC, three-phase, 4-wire plus ground (Standard Voltage). or 220/127VAC configurable from the Front Panel
or 480Y/277 VAC, 3 Phase, 3-wire + ground - with external line upand match K20 – Shielded transformer cabinet (Optional)
Frequency: 60/50Hz, ±0.5%, 1.0%, 2.0%, 5.0% User settable, 60Hz, ± 0.01Hz when free running. Voltage regulation: ±2% for balanced load.Voltage Distortion: <1% with balanced loads, 2% with unbalanced loads (THD).
AC Output Characteristics
Voltage Transient (Step Load) Response: ±5% for 100% step load change.Voltage Recovery Time: Return to within 1% of nominal value within 20 milliseconds.Phase Angle Displacement: 120 degrees + 1º for balanced load; 120º, + 1º for 100% unbalanced load.Non-Linear Load Capability: Output voltage total harmonic distortion shall be less than 1% when connected to a 100% non-linear load with a crest factor not to exceed 3%.Slew Rate: ±10 hertz per second.Power Factor: 0.9 at the rated volt amperes (VA).Inverter Overload Capability: 125% of rated load for 10 minutes, 150% of rated load for 60 seconds.Bypass Overload Capability: 400% for 10 seconds, 1000% for ½ cycle.Output Waveform: Sinusoidal.Efficiency: Up to 90% at Full Load.
Connections
Air Flow
The heat dissipation needed for the correct operation of the UPS is brought about by the air current made by the fans located inside the UPS.
Clearance: FRONT and at least 3” rear clearance and one side for units with internal batteries..
Control Panel Display
Panel Controls
The UPS unit incorporates the necessary controls, instruments and indicators to allow the operator to monitor the system status and performance, as well as take any appropriate action. The UPS Control and Display has (3) sections.
LED IndicatorsGraphic DisplayKeyboard/Navigation
LED Indicators for: Rectifier Input Voltage OK – Green Unit on Bypass – Orange Inverter working – Green Unit on Battery/Main Failure – Red Alarm Activated – Red
Graphic DisplayA main display 3.5” H x 4.58” W screen will be provided to display the UPS measurements and for consulting the various menus which the user shall select using the designated function keys.
Keyboard/Navigation Area with (6) function keys to navigate through menu screens which is active. The display will indicate the function belonging to the corresponding key in the appropriate box, access main menu, go back to previous menu or display, scroll, confirm selection and silence function keys.
Keyboard Control
Control FunctionsNavigation Buttons
The UPS shall have buttons allowing the user to scroll through the display menus provided by the graphic display.
ENT «Enter» key. Confirmation of orders, program values. á «Left» key for submenu navigation, or cursor displacement. â «Right» key for submenu navigation, or cursor displacement. æ «Up» key for menu navigation, or digit modification. ç «Down» key menu navigation, or digit modification.
ESC «Escape» key. Return to main screen, cancel/finish programming.ENT, áWhen pressed simultaneously at least during 3 seconds,
equivalent to an Emergency Power Off (EPO), turn-off any voltage at the output.
Front Control Panel
Main Screen
Screen Information
Input voltages phase to phaseInput voltages phases to neutral Input current per each phase Output voltages phase to phaseOutput voltages phases to neutralOutput current per each phase DC bus voltages positive and negativeBattery voltages positive and negative
Input apparent power of L1Input apparent power of L2 Input apparent power of L3 Input active power of L1 Input active power of L2Input active power of L3 Total input apparent power and active power Input power factor per each phase Input, bypass and output frequencies Rectifier, inverter and battery temperatures (units 1ºC).
Screen Information
Inverter output voltages phases to neutral Inverter output current per each phase Bypass voltages phases to neutral Bypass current per each phase Charge battery currents positive and negativeDischarge battery currents positive and negative
Apparent output power L1 Apparent output power L2 Apparent output power L3Active output power L1 Active output power L2 Active output power L3 Total apparent and active powers Output power factor of each phase Output load of three phases Total input load and total output load Estimated backup time
Screen Information
Standard Communications
SNMP: Internal SNMP Card is standard on all UPS’s to allow UPS management across a LAN using any of the main network communication protocols - TCP/IP, HTTP and network interface (SNMP). ViewPower Pro shutdown/monitoring software shall enable the UPS to integrate easily into medium and large sized networks and provide reliable communications between the UPS and management systems employed.
Modbus: Internal MODBUS/JBUS Card, Protocol converter also standard and used to monitor the UPS using the MODBUS/JBUS protocol on RS232 or RS485 serial lines. It shall also manage a second independent RS232 serial line that can be used to connect to other devices such as the SNMP.
Relay Interface: Four voltage free relays with no common point is standard, provided through a sub-D9 connector. Consisting of 4 output signaling relays
a. Battery Discharge (NO or NC)b. Unit on Bypassc. Low Batteryd. General alarm
Com Ports Standard
Com Port RS-232 & RS-485In the same connector DB9 there are both ports of communication of the equipment, the RS-232
and the RS-485, they cannot be simultaneously used. ˙ Both channels are in use for connecting the UPS with any machine or
devices that has this standard bus. The RS-232 consists of the transmission of serial data, so it is possible to send a large amount of information through a communication cable of just 3 wires.
Communication protocol of the RS-232
The communication protocol used is of MASTER/SLAVE type. The computer or computer system (MASTER) asks about certain data, and the UPS (SLAVE) answers immediately with the required data.
Firstly it will be programmed the communication channel of the computer with the same parameters as the communication channel of the UPS. Then it will be prepared to start the communication and therefore send the UPS the first question.
Physical structure of the RS-485.
Unlike other serial communication links, this uses only 2 wires (pins 4 and 9 of the female DB9 connector) to perform the dialogue between the systems connected to the network. The communication is established by sending and receiving signals in differential mode, which gives the system great immunity to noise and a long reach (approx. 2,635 ft. (800 m).
Communications
Part Number Description
FLPL-SNMPSNMP/WEB Card and UPS Shutdown and Monitoring Software for Windows/Novell(Standard on ALL Models)
FLPL TH-EMD
The Environmental Monitoring Device (EMD) is a connectivity device to remote monitor temperature, humidity, and smoke via SNMP manager. It also allows to receive contact closure signals, enabling to communicate with up 4 compatible devices such as security system and alarm system. (Requires standard FLPL-SNMP)
FLPL-MODBUS-TCP
TCP Converter w/ Power Supply - Is a converter for the Modbus where the user has programmable applications. TCP is for customers that only use Modbus through TCP. The BASIC programming language enables creation of custom application solutions for the implementation of a serial RS-232/422/485 interface in Ethernet. Includes CD-ROM with examples, additional software and user documentation (PDF).
FLP-ViewPower Pro Shutdown and Monitoring Software (Standard on ALL Models)
FLP-REMOTE- PANELRemote Alarm/Annunciation Panel – System Normal, UPS Alarm, Shutdown Imminent, Mains Failure, Load on Service and Inverter Faults indication and 50 ft. cable
ELS Cabinet 9, 13 & 18kW
ELS Battery Cabinet 9, 13 & 18kW
ELS Battery Cabinet 9, 13 & 18kW
ELS Cabinet 27 & 36kW
ELS Battery Cabinet 27 & 36kW
ELS Battery Cabinet 27 & 36kW
FirstLine PL Battery
The UPS uses a valve-regulated sealed lead acid (VRLA) heavy duty industrial battery, designed for auxiliary power service in a UPS application. The primary battery is furnished with impact-resistant plastic cases and housed in a matching cabinet(s) next to the UPS. The UPS is capable of utilizing Wet Cell & NiCad batteries.
Protection Against Deep Discharge and Self-Discharge: The UPS is equipped with a device designed to protect the battery against deep discharge, depending on discharge conditions, with isolation of the battery by a circuit breaker. From the monitoring panel you can adjust the battery shutdown voltage as a function of a discharge coefficient to avoid excessive discharge at less than the rated output. A second device helps avoid self-discharge of the battery into the UPS control circuits during an extended shutdown of the UPS (over two hours).Battery Self-Tests: 1. The battery monitoring system performs the following automatic functions:
• Battery circuit check, programmable 9-99 days. • Partial discharge test every three months.
Standard Battery Characteristics
Standard BatteryValve Regulated Lead Acid (VRLA), Sealed Maintenance Free, specifically designed for high efficient discharge applications. Its characteristics are high energy density, small footprint and high discharge efficiency. Rated for more than 260 cycles at 100% discharge, in cycle service, up to 10 years in standby service. .
6 Cells per unit12 volts per unit
Battery Voltage: 432 volts DC nominal, 486VDC float. .
Battery Cabinet Connection
9 & 13.5kW 4 x 2, 4 x 4 Transformer Cabinet
18 & 27kW 4 x 2, 4 x 4 Transformer Cabinet
36kW 4 x 2, 4 x 4 Transformer Cabinet
9 &13.5kW Wall Mount Bypass
18 & 27kW Wall Mount Bypass
36kW Line Up Floor Mount Bypass
PDU Cabinet
Standard Single Input
Standard Dual Input
2 X 2 with External Bypass
4 X 2 with Input Transformer without Bypass
4 X 2 with Input Transformer & Bypass
4 X 4 with Input/Output Transformer without Bypass
4 X 4 with Input/Output Transformer & Bypass
Paralleling
The UPS has expansion capabilities for up to 4 modules paralleled for capacity or redundancy as required to support future growth. The UPS units can be connected in parallel and shall share the current and load between them.In a system with several UPS units connected in parallel, there is a single MASTER unit and the remaining units are SLAVE units. The UPS units must be the same rating and the MASTER is chosen on start-up. The MASTER and SLAVE units can exchange roles. If a unit is being serviced, e.g. due to an inverter fault, it will automatically be excluded. The load at this point will be shared between the units that are still active; if the power in output is excessive for the remaining UPSs, the system logic will switch all the units, including the UPS that was excluded, onto the by-pass line.
Communication Connections
Standard Monitoring & Shutdown Software
ViewPower Pro:Is an advanced UPS management software which is perfect for home users and enterprises. It can monitor and manage from one to multiple UPSs in a networked environment including LAN, INTERNET and RS485-based networks. Integrated with Shutdown Wizard, it can not only prevent data loss from power outage and safely shutdown systems, but also store programming data and scheduled shut down UPSs. All UPS working data and event records can be kept in local database system.
Platforms supported by software are listed below: Windows 2000 Windows XP/2003/Vista/2008 (32-bit & 64-bit) Windows 7/8 (32-bit & 64-bit) Windows SBS 2011 Linux RedHat 8, 9 Linux RedHat Enterprise AS3, AS5, AS6 (32-bit) Linux RedHat Enterprise AS6 (64-bit) Linux RedHat Enterprise 5.2 (32-bit & 64-bit) Linux SUSE 10 (32-bit & 64-bit) Linux Cent OS 5.4 (32-bit) Linux Ubuntu 8.X, 9.X, 10.X (32-bit) Linux Ubuntu 10.X (64-bit) Linux Ubuntu 12.04 (32-bit & 64-bit) Linux Fedora 5 Linux OpenSUSE 11.2 (32-bit & 64-bit) Linux Debian 5.x, 6.x (32-bit) Linux Debian 6.x (64-bit) Mac OS 10.6 (64-bit) Mac OS 10.7 (64-bit) Solaris 10 for x86 (32-bit)
ViewPower Pro Features
ViewPower Pro includes monitor service, WEB service and tray service. Monitor service: It is the core of ViewPower Pro software. Monitor service automatically find UPSs in the networks, store UPS working data and event information. It will communicate with UPS, record events, notify users with events, and execute command according to the users’ request.
WEB service: It offers Http or Https service for local or remote users. Users can manage and monitor UPSs for real-time status, information and modify UPS setting parameters via browser such as IE and Firefox.
Tray service: It is management tool for ViewPower Pro software. It includes start monitor, stop monitor, SNMP manager and so on.
Centralized control and monitor up to 1000 UPSs via SNMP or Modbus networks. Offers WEB service to allow remote monitoring service via Intranet or Internet. Offers quick overview for UPS monitoring in Text and Graphic view. Offers user-customized background picture for graphic view with simple drag and drop. Scheduled UPS on/off, battery test, and scheduled wake on LAN programs.
ViewPower Pro Structure
TCP Converter Option
TCP Converter w/ Power Supply - Is a converter for the Modbus where the user has programmable applications. TCP is for customers that only use Modbus through TCP. The BASIC programming language enables creation of custom application solutions for the implementation of a serial RS-232/422/485 interface in Ethernet. Includes CD-ROM with examples, additional software and user documentation (PDF).
Environmental Monitoring Device (EMD) Option
The Environmental Monitoring Device (EMD) is a connectivity device to remote monitor temperature, humidity, and smoke via SNMP manager. It also allows to receive contact closure signals, enabling to communicate with up (4) compatible devices such as security system and alarm system. Plug & use for simple installation with SNMP manager Monitor temperature and humidity to protect your precious equipment Allow 4 contact closure signals for user-defined usage Management software to remote monitor temperature and humidity status via web browser Measure temperatures between 0 to 100°C with an accuracy of ±1.5°C Measure relative humidity between 10 to 90% RH with an accuracy of ±3%
Environmental Monitoring Device (EMD)
Function Diagram
Remote Monitor Panel Option
Remote Monitoring Panel:
Provides basic UPS status with LED Indicators, Audible Alarm and Silence Button:
1. Unit on Battery2. Low Battery3. Unit on Bypass4. User Specified Alarm
Silence/Reset Button.
Other Options
Seismic Bracing & Withstand CertificationSite specific Seismic Bracing for Zone A-F with certification and drawings available.
Top or Side Cable EntryStandard cable entry is from the bottom with availability for top or side incoming entry.
Harsh Environment EnclosureThe UPS and any accessory cabinet(s) are capability of being mounted and completely wired internal to, include AC cooling, inside any NEMA type enclosure (NEMA 12, 3R, 4X) by the manufacturer.
Spare PartsAvailable in three levels - Minor, Moderate and
Major
Service Agreements Multi level service and maintenance agreements available.