Product Test for FLEXIMOUNTS Overhead Garage Rack
-
Upload
mandy-chow -
Category
Sales
-
view
93 -
download
2
Transcript of Product Test for FLEXIMOUNTS Overhead Garage Rack
Test for FLEXIMOUNTS Ceiling Garage Rack
Static load test :Steadily place the rack on the standard test bench or flat ground and measure the distance from the downside of object to the ground. (Figure 1)
Then keep loading for at least 24 hours and measure the distance from the same point of the downside of the object to the ground. (Figure 2)
Thus, we got: Loading distance – None-loading distance = Max. deflection value.
Then unload for 2 hours and measure the distance from the same point of the downside of the object to the ground. (Figure 3)
Thus, we got: Unload distance – None-loading distance = Residual deformations value.
Figure1: Test for FLEXIMOUNTS Garage Rack
Figure 2 : Test for FLEXIMOUNTS Garage Rack
Standard weight loading test.
Test for FLEXIMOUNTS Garage Rack
Destructive test with 440 lbs loading.
Figure 3: Test for FLEXIMOUNTS Garage Rack
Destructive test with 660 lbs loading.
Test for ceiling brackets and vertical supports