PRODUCT SPECIFICATION SHEET Monkeytoe Duct Support...• Lightweight, high strength T6 aluminum...

5
Monkeytoe Duct Support Adjustable roof-mounted duct support system ensuring the correct installation of condenser units, fans and other lightweight equipment on the roof. TYPICAL USES / APPLICATIONS Ideally suited as a support for a series of condenser units Supports for fans and flues and other lightweight equipment Supports for cable trays, pipes and other services Support for equipment up to 250kg CHARACTERISTICS / ADVANTAGES Kitset componentry ensures easy on site assembly Lightweight, high strength T6 aluminum components Increased safe working load of 250kg see Load Capacities below) Unique extrusion design accepts M10 Stainless Steel spring nuts for ease of install Low maintenance and neat appearance Suitable for all Steel and Membrane roof profile design Roof angle adjustment can be achieved from 4°- 45° (extra bracing may be required at higher angles). PRODUCT DESCRIPTION TECHNICAL DATA / MATERIALS All componentry manufactured from Marine grade high tensile aluminium with polyethylene clips and stainless steel fixings. Extrusion: High strength T6 Aluminium with options of powder coating. Fixings: Stainless Steel 304 Grade Roof Connections: • Roofing Clips High density Polyethylene - UV resistant • Galvanised Roofing Tek screws, • Neoprene Sealing Washers. Monkeytoe Duct Support 1/5 PRODUCT SPECIFICATION SHEET TESTS APPROVALS / STANDARDS Structural design action B1 AS/NZS 1170 Standards Australia / New Zealand Aluminium Structures, Part 1: Limit State Design AS/NZS 1664.1 Standards Australia / New Zealand NZS/AS 1657 WARRANTY Lifetime Warranty (25 years) MAINTENANCE • Visual inspection for any damage or loose fixings must be done periodically and prior to use. No certified maintenance is required. Basic wear and tear preventative maintenance is recommended.

Transcript of PRODUCT SPECIFICATION SHEET Monkeytoe Duct Support...• Lightweight, high strength T6 aluminum...

Page 1: PRODUCT SPECIFICATION SHEET Monkeytoe Duct Support...• Lightweight, high strength T6 aluminum components • Increased safe working load of 250kg oad Capacities below) see L •

Monkeytoe Duct SupportAdjustable roof-mounted duct support system ensuring the correct installation of condenser

units, fans and other lightweight equipment on the roof.

TYPICAL USES / APPLICATIONS • Ideally suited as a support for a series of condenser units

• Supports for fans and flues and other lightweight

equipment

• Supports for cable trays, pipes and other services

• Support for equipment up to 250kg

CHARACTERISTICS / ADVANTAGES • Kitset componentry ensures easy on site assembly

• Lightweight, high strength T6 aluminum components

• Increased safe working load of 250kg

see Load Capacities below)

• Unique extrusion design accepts M10 Stainless Steel

spring nuts for ease of install

• Low maintenance and neat appearance

• Suitable for all Steel and Membrane roof profile design

• Roof angle adjustment can be achieved from 4°- 45° (extra bracing may be required at higher

angles).

PRODUCTDESCRIPTION

TECHNICAL DATA / MATERIALS

All componentry manufactured from Marine grade high tensile aluminium with polyethylene

clips and stainless steel fixings.

Extrusion: High strength T6 Aluminium with options of powder coating.

Fixings: Stainless Steel 304 Grade

Roof Connections:

• Roofing Clips High density Polyethylene - UV resistant

• Galvanised Roofing Tek screws,

• Neoprene Sealing Washers.

Monkeytoe Duct Support1/5

PRODUCT SPECIFICATION SHEET

TESTS APPROVALS / STANDARDS• Structural design action B1

• AS/NZS 1170 Standards Australia / New Zealand

• Aluminium Structures, Part 1: Limit State Design AS/NZS 1664.1 Standards Australia / New

Zealand NZS/AS 1657

WARRANTY Lifetime Warranty (25 years)

MAINTENANCE • Visual inspection for any damage or loose fixings must be done periodically and prior to use.

• No certified maintenance is required.

• Basic wear and tear preventative maintenance is recommended.

Page 2: PRODUCT SPECIFICATION SHEET Monkeytoe Duct Support...• Lightweight, high strength T6 aluminum components • Increased safe working load of 250kg oad Capacities below) see L •

Monkeytoe Duct Support2/5

Monkeytoe Duct Support

Page 3: PRODUCT SPECIFICATION SHEET Monkeytoe Duct Support...• Lightweight, high strength T6 aluminum components • Increased safe working load of 250kg oad Capacities below) see L •

A3

DWG No:

DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nz

Th

is dra

win

g a

nd

asso

ciate

d d

esig

n is th

e co

pyrig

ht a

nd

pro

pe

rty of M

on

keyto

e L

td. It sh

all n

ot b

e u

sed

for a

ny p

urp

ose

or p

roje

ct, with

ou

t prio

r writte

n co

nse

nt o

the

r tha

t de

sign

ate

d b

y Mo

nke

ytoe

Ltd

A

B

C

F

E

D

8764 51 2 3

18/06/2018

SHEET 1 OF 1

REV:01

MONKEYTOE

2004-DSA-1

TYPE A DUCT SUPPORT

SCALE: 1:40

Strap Duct or Bolt Flange to Support Rail (By Others)

DS001 Fully Adjustable Swivel Bracket With M10 s/s Bolts and Spring nuts

DS004 Vertical Support

DS003 Roof Rail

DS005 Support Rail Comes with 6 x 25 mm s/s Teks

Monkeytoe Roof Clip: Top Fix And Concealed Fix Roof Clip Availible See Clip Details

Marine Grade Aluminum

30

0-1

00

0 m

m

C

'P' Purlin SpacingMAX 2500 mm

'C' H

eig

ht

to D

uct

Cen

tre L

ine

MA

X 2

120

mm

'S' Support SpacingMax 2000mm

'H' D

uct H

eig

ht

MA

X 2

240

mm

'W' Duct WidthMAX 2240 mm

Braced Bay(Brace Part no. PA50.50.5) Specify Length For Order

STANDARD DUCT SUPPORT PARTS OTHER LENGTHS AVAILABLE ON REQUEST

Standard PartNo.

'R' DS003 RoofRail Length in

mm

'V' DS004 VerticalSupport length in mm

'L' DS005 SupportRail Length in mm

DS003.11 1100

DS003.13 1300

DS003.19 1900

DS004.11 1100

DS004.13 1300

DS004.16 1600

DS004.19 1900

DS005.10 1000

DS005.12 1200

DS005.15 1500

DS005.18 1800

Swivel Bracket Adjusts To Suit Roof Pitch And Duct Size

'L' Support RailLength

'V'

Vert

ical S

upp

ort

Len

gth

'R' Roof RailLength

* ()Denotes No. Of Bays Before Bracing Is Required Includes Braced BayDESIGN CONDITIONS:Building Importance Level - 2Seismic 'Z' Factor - 0.4Site Wind Speed - 37 m/s (Does Not Include Lee Zones or Offshore Locations About The North And South Islands)

TYPE A DUCT SUPPORT DESIGN GUIDEContact Product Support For Any Variations

'GL' ToDuctCentreLine

'P' Purlin Spacing 'W' Duct Width Max 'H'Duct Height Max 'S' Support SpacingInsulated DuctMass (Kg/M)

≤6000≤1000 ≤800 ≤800 ≤1000(7) ≤1250(5) ≤1500(3) ≤1750(2) ≤2000(2) 43.4

≤1500 ≤1250 ≤1250 ≤1000(4) ≤1250(3) ≤1500(2) ≤1750(1) 74.2

≤2000 ≤1800 ≤1800 ≤1000(3) ≤1250(2) 106.6

≤2500 ≤2240 ≤2240 ≤1000(2) 141.5

≤9000≤1000 ≤800 ≤800 ≤1000(7) ≤1250(5) ≤1500(3) ≤1750(2) ≤2000(2) 43.4

≤1500 ≤1250 ≤1250 ≤1000(4) ≤1250(3) ≤1500(2) 74.2

≤2000 ≤1800 ≤1800 ≤1000(3) 106.6

≤12000≤1000 ≤800 ≤800 ≤1000(7) ≤1250(5) ≤1500(3) ≤1750(2) ≤2000(2) 43.4

≤1500 ≤1250 ≤1250 ≤1000(4) ≤1250(3) 74.2

Ground Level

Page 4: PRODUCT SPECIFICATION SHEET Monkeytoe Duct Support...• Lightweight, high strength T6 aluminum components • Increased safe working load of 250kg oad Capacities below) see L •

A3

DWG No:

DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nz

Th

is dra

win

g a

nd

asso

ciate

d d

esig

n is th

e co

pyrig

ht a

nd

pro

pe

rty of M

on

keyto

e L

td. It sh

all n

ot b

e u

sed

for a

ny p

urp

ose

or p

roje

ct, with

ou

t prio

r writte

n co

nse

nt o

the

r tha

t de

sign

ate

d b

y Mo

nke

ytoe

Ltd

A

B

C

F

E

D

8764 51 2 3

19/06/2018

SHEET 1 OF 1

REV:01

MONKEYTOE

2004-DSB-1

TYPE B DUCT SUPPORT

SCALE: 1:40

Strap Duct or Bolt Flange to Support Rail (By Others)

DS001 Fully Adjustable Swivel Bracket With M10 s/s Bolts and Spring nuts

DS004 Vertical Support

DS003 Roof Rail

DS005 Support Rail Comes with 6 x 25 mm s/s Teks

Monkeytoe Roof Clip: Top Fix And Concealed Fix Roof Clip Availible See Clip Details

Marine Grade Aluminum

10

00

-15

00 m

m

C

'P' Purlin SpacingMAX 2500 mm

'GL

' Heig

ht to

Du

ct C

entr

e L

ine

MA

X 2

120

mm

'S' Support SpacingMax 2000mm

'H' D

uct H

eig

ht

MA

X 2

240

mm

'W' Duct WidthMAX 2240 mm

Braced Bay(Brace Part no. PA50.50.5) Specify Length For Order

TYPE B DUCT SUPPORT DESIGN GUIDEContact Product Support For Any Variations

'GL'Height ToDuctCentreLine

'P' Purlin Spacing 'W' Duct Width Max 'H'Duct Height Max 'S' Support SpacingInsulated DuctMass (Kg/M)

≤6000≤1000 ≤800 ≤800 ≤1000(7) ≤1250(5) ≤1500(3) ≤1750(2) ≤2000(2) 43.4

≤1500 ≤1250 ≤1250 ≤1000(4) ≤1250(3) ≤1500(2) ≤1750(1) 74.2

≤2000 ≤1800 ≤1800 ≤1000(3) ≤1250(2) 106.6

≤2500 ≤2240 ≤2240 ≤1000(2) 141.5

≤9000≤1000 ≤800 ≤800 ≤1000(7) ≤1250(5) ≤1500(3) ≤1750(2) ≤2000(2) 43.4

≤1500 ≤1250 ≤1250 ≤1000(4) ≤1250(3) ≤1500(2) 74.2

≤2000 ≤1800 ≤1800 ≤1000(3) 106.6

≤12000≤1000 ≤800 ≤800 ≤1000(7) ≤1250(5) ≤1500(3) ≤1750(2) ≤2000(2) 43.4

≤1500 ≤1250 ≤1250 ≤1000(4) ≤1250(3) 74.2

STANDARD DUCT SUPPORT PARTS OTHER LENGTHS AVAILABLE ON REQUEST

Standard PartNo.

'R' DS003 RoofRail Length in

mm

'V' DS004 VerticalSupport length in mm

'L' DS005 SupportRail Length in mm

DS003.11 1100

DS003.13 1300

DS003.19 1900

DS004.11 1100

DS004.13 1300

DS004.16 1600

DS004.19 1900

DS005.10 1000

DS005.12 1200

DS005.15 1500

DS005.18 1800

Swivel Bracket Adjusts To Suit Roof Pitch And Duct Size

'L' Support RailLength

'V'

Vert

ical S

upp

ort

Len

gth

'R' Roof RailLength

* ()Denotes No. Of Bays Before Bracing Is Required Includes Braced BayDESIGN CONDITIONS:Building Importance Level - 2Seismic 'Z' Factor - 0.4Site Wind Speed - 37 m/s (Does Not Include Lee Zones or Offshore Locations About The North And South Islands)

PA25.25.3 BraceAnd 25 mm s/s Tek Screws Specify Length For Order

Ground Level

Page 5: PRODUCT SPECIFICATION SHEET Monkeytoe Duct Support...• Lightweight, high strength T6 aluminum components • Increased safe working load of 250kg oad Capacities below) see L •

A3

DWG No:

DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nz

Th

is dra

win

g a

nd

asso

ciate

d d

esig

n is th

e co

pyrig

ht a

nd

pro

pe

rty of M

on

keyto

e L

td. It sh

all n

ot b

e u

sed

for a

ny p

urp

ose

or p

roje

ct, with

ou

t prio

r writte

n co

nse

nt o

the

r tha

t de

sign

ate

d b

y Mo

nke

ytoe

Ltd

A

B

C

F

E

D

8764 51 2 3

19/06/2018

SHEET 1 OF 1

REV:01

MONKEYTOE

2004-DSC-1

TYPE C DUCT SUPPORT

SCALE: 1:40

Strap Duct or Bolt Flange to Support Rail (By Others)

DS001 Fully Adjustable Swivel Bracket With M10 s/s Bolts and Spring nuts

DS004 Vertical Support

DS003 Roof Rail

DS005 Support Rail Comes with 6 x 25 mm s/s Teks

Monkeytoe Roof Clip: Top Fix And Concealed Fix Roof Clip Availible See Clip Details

Marine Grade Aluminum

15

00

-20

00 m

m

C

'P' Purlin SpacingMAX 2500 mm

'GL

' Heig

ht to

Du

ct C

entr

e L

ine

MA

X 2

120

mm

'S' Support SpacingMax 2000mm

'H' D

uct H

eig

ht

MA

X 2

240

mm

'W' Duct WidthMAX 2240 mmTYPE B DUCT SUPPORT DESIGN GUIDE

Contact Product Support For Any Variations

'GL'Height ToDuctCentreLine

'P' Purlin Spacing 'W' Duct Width Max 'H'Duct Height Max 'S' Support SpacingInsulated DuctMass (Kg/M)

≤6000≤1000 ≤800 ≤800 ≤1000(7) ≤1250(5) ≤1500(3) ≤1750(2) ≤2000(2) 43.4

≤1500 ≤1250 ≤1250 ≤1000(4) ≤1250(3) ≤1500(2) ≤1750(1) 74.2

≤2000 ≤1800 ≤1800 ≤1000(3) ≤1250(2) 106.6

≤2500 ≤2240 ≤2240 ≤1000(2) 141.5

≤9000≤1000 ≤800 ≤800 ≤1000(7) ≤1250(5) ≤1500(3) ≤1750(2) ≤2000(2) 43.4

≤1500 ≤1250 ≤1250 ≤1000(4) ≤1250(3) ≤1500(2) 74.2

≤2000 ≤1800 ≤1800 ≤1000(3) 106.6

≤12000≤1000 ≤800 ≤800 ≤1000(7) ≤1250(5) ≤1500(3) ≤1750(2) ≤2000(2) 43.4

≤1500 ≤1250 ≤1250 ≤1000(4) ≤1250(3) 74.2

STANDARD DUCT SUPPORT PARTS OTHER LENGTHS AVAILABLE ON REQUEST

Standard PartNo.

'R' DS003 RoofRail Length in

mm

'V' DS004 VerticalSupport length in mm

'L' DS005 SupportRail Length in mm

DS003.11 1100

DS003.13 1300

DS003.19 1900

DS004.11 1100

DS004.13 1300

DS004.16 1600

DS004.19 1900

DS005.10 1000

DS005.12 1200

DS005.15 1500

DS005.18 1800

Swivel Bracket Adjusts To Suit Roof Pitch And Duct Size

'L' Support RailLength

'V'

Vert

ical S

upp

ort

Len

gth

'R' Roof RailLength

* ()Denotes No. Of Bays Before Bracing Is Required Includes Braced BayDESIGN CONDITIONS:Building Importance Level - 2Seismic 'Z' Factor - 0.4Site Wind Speed - 37 m/s (Does Not Include Lee Zones or Offshore Locations About The North And South Islands)

Ground Level

Braced Bay(Brace Part no. PA50.50.5) Specify Length For Order

PA50.50.5 BraceAnd 25 mm s/s Tek Screws Specify Length For Order