PRODUCT SPECIFICATION SHEET Monkeytoe Caged Ladder · 2019. 5. 24. · Caged Ladder SHEET 1 OF 1...
Transcript of PRODUCT SPECIFICATION SHEET Monkeytoe Caged Ladder · 2019. 5. 24. · Caged Ladder SHEET 1 OF 1...
Monkeytoe Caged LadderPermanent caged access ladder system that provides safe and easy accces to elevated areas
with or without ladder stiles to extend 1000mm or more above landing surface.
TYPICAL USES / APPLICATIONS • Access requirements with heights that don’t
exceed 6000mm
• Rooftop access
• Plant maintenance platforms
• Ceiling spaces
• Industrial tank access
• Hospitals, office blocks, sports centre
CHARACTERISTICS / ADVANTAGES • Unique rung profile design makes ladder comfortable and
easy to climb
• Low maintenance and neat appearance
• Modular design for fast and easy install
• Propietary product with engineering, and pre-configued to
code compliance dimensions
• High level of safety and confidence for maintenance personal
• Single person use, 150kg rated
• Stress load tested – 1.8kN applied at 75º
PRODUCTDESCRIPTION
TECHNICAL DATA / MATERIALS
• All componentry and accessories manufactured from high grade structural aluminium
• Product can be powder coated
• Fixing requirements:
• Steel purlin
- 2 x M1O S/S bolts OR
- 2 x M8 toggle bolts OR
- 3 x 14G tek screws (2mm min purlin thickness)
• Steel structure
- 2 x M1O S/S bolts
• Concrete (Min 25MPa)
- 2 x (12mm x 100) tru-bolt OR
- 2 x (10mm x 100) screw bolt
• Brick
- 2 x (10 x 100) screw bolt
• Composite panel
- 2 x 10mm through bolt with spreader plate on rear, OR
- 2 x M8 toggle bolts
Monkeytoe Caged Ladder | LD021/8
PRODUCT SPECIFICATION SHEET
CODE: LD02
Monkeytoe Caged Ladder | LD022/8
TESTS APPROVALS / STANDARDS• Structural design action B1
• AS/NZS 1170 Standards Australia / New Zealand (Relevant parts)
• Aluminium Structures, Part 1: Limit State Design AS/NZS 1664.1 Standards Australia / New
Zealand NZS/AS 1657
WARRANTY Lifetime Warranty (10 years)
MAINTENANCE • It is recommended that plant platforms are included in the standard ‘building warrant of
fitness’ inspections.
• All damage or loose fixings to be reported immediately to asset manager or building owner
for correction.
REFERENCE
Monkeytoe Caged Ladder | LD023/8
Monkeytoe Caged LadderLD02
A3
DWG No:
DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nz
Th
is dra
win
g a
nd a
ssocia
ted
desig
n is th
e co
pyrig
ht a
nd
pro
pe
rty of M
onke
ytoe L
td. It sh
all n
ot b
e u
sed
for a
ny p
urp
ose
or p
roje
ct, with
ou
t prio
r writte
n co
nse
nt o
the
r tha
t desig
na
ted
by M
on
keyto
e L
td.©
2004-LAD-CG-01
Caged Ladder
SHEET 1 OF 1
REV:01SCALE: 1:25
1/06/2018
MONKEYTOE
1DETAIL 1
1:2.5
2
DETAIL 21:2.5
600 O/S
90
0 m
in.
110
0 m
ax.
FIXINGS Metal - M8 Bolt Timber - M10 Coach Screw Concrete - M10 Concrete Screw Purlins - 75mm TEK Screw
PROFILEDALUMINIUM
RUNG
200 min.940. max
ALUMINIUM LADDER
ALUMINIUM FIXING BRACKET(REFER TO LADDER FIXING
BRACKET DRAWINGS)
ALUMINIUMSAFETY CAGE
20
00
min
. 22
00
max.
525 I/S
30
0845728
A A
SECTION A-A 1:25
R356
700 I/S
24
00
ma
x.
60
00
ma
x.
NOTES:
DESIGNED IN ACCORDANCE WITH- AS/NZS 1170- AS/NZS 1657:2018- AS/NZS 1892:1996- B! & B2 DURABILITY CODES- RELEVANT STATUTORY OHS CODES OF PRACTICE
WORKING LOAD LIMIT: 150kg
M10x100 S/STEELCONC. SCREW BOLT
ASSEMBLY CONFIGURATIONS
616
280-400
604
AA
75x6 FB5052 AL
50x6 FB5052 AL
30 37.
5
9 THRU
B
BSECTION A-A
37.
5
9 THRU
245 245
0
63
308
553
616
SECTION B-B
M8 X 60mm MUSHROOM HEAD S/STEEL COACH BOLT
M8 X 25mm S/STEEL BOLT
M10 X 60mm S/STEEL COACH SCREW
50x6 FB BRACINGNOT USED FORBASE MOUNT
14G x 75mm Galv.TEK SCREW
A3SCALE 1:5
DWG No:
DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nzREV:02
MONKEYTOE
This drawing and associated design is the copyright and property of M
onkeytoe Ltd. It shall not be used for any purpose or project, without prior w
ritten consent other that designated by Monkeytoe Ltd.©
01/05/2018LD421.280-400
SHEET 1 OF 1
LADDER BRACKET - 280-400mm
M10x100 S/STEELCONC. SCREW BOLT
ASSEMBLY CONFIGURATIONS
800
600 - 1000
604
AA
75x6 EA6261-T6 AL
50x6 FB5052 AL
9 THRU
30
35
B
B
SECTION A-A
800
3 x 9 THRU
245 245
0
57
302
547
604
SECTION B-B
M8 X 60mm MUSHROOM HEAD S/STEEL COACH BOLT
M8 X 25mm S/STEEL BOLT
M10 X 60mm S/STEEL COACH SCREW
14G x 75mm Galv.TEK SCREW
A3SCALE 1:7
DWG No:
DO NOT SCALE DIMENSIONS IN MILLIMETERS0800 658 637 - www.monkeytoe.co.nzREV:02
MONKEYTOE
This drawing and associated design is the copyright and property of M
onkeytoe Ltd. It shall not be used for any purpose or project, without prior w
ritten consent other that designated by Monkeytoe Ltd.©
01/05/2015LD421.600-1000
SHEET 1 OF 1
LADDER BRACKET - 600-1000mm